06-1154-001S GENERAL NOTES: 1. THE CONTRACTOR SMALL VISIT THE PREMISES AND THOROUGHLY FAMILIARIZE HIMSELF WITH ALL DETAILS OF THE WORK AND WORKING CONDITIONS. VERIFY ALL DIMENSIONS IN THE FIELD, AND ADVISE THE ARCHITECT / ENGINEER OF ANY D15CREPANCY BEFORE PERFORMING THE WORK 2. THE CONTRACTOR SHALL PERFORM ALL WORK REQUIRED UNDER THIS CONTRACT FOR A COMPLETE INSTALLATION AND IN SUCH MANNER THAT SURFACES NOT AFFECTED BY REMOVAL OF EXISTING OR FROM NEW WORK SHALL REMAIN UNDISTURBED AND NORMAL ACTIVITIES AT THE INSTALLATION MAY CONTINUE WITH THE LEAST POSSIBLE INTERFERENCE. ALL DEBRIS SHALL BE REMOVED FROM THE SITE OF THE WORK AT THE END OF EACH WORKING DAY. MATERIALS AND EQUIPMENT SHALL BE STORED ONLY AT LOCATIONS APPROVED BY THE ARCHITECT / ENGINEER AND OWNER'S REPRESENTATIVE. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY OF THE STRUCTURES AND PERSONNEL DURING THE WORK UNDER TH16 CONTRACT. ALL ALTERING, CUTTING, DRILLING OF PAVEMENT, FLOOR AND OTHER MODIFICATIONS SHALL BE NEATLY AND CAREFULLY DONE' BY SKILLED MECHANICS. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DAMAGE TO EXISTING WORK, MATERIALS, AND EQUIPMENT AS A RESULT OF HIS OPERATIONS. ALL DAMAGED WORK SHALL BE REPAIRED OR REPLACED WITH MATERIALS OF LIKE TYPE, QUALITY AND FINISH BY SKILLED MECI-4ANI05 OF THE TRADES INVOLVED AT NO ADDITIONAL COST TO THE OWNER AND TO THE FULL SATISFACTION OF THE ARCHITECT / tNGINEER 5. D15PO5AL OF ALL MATERIAL NOT SPECIFIED OR SHOWN TO BE SALVAGED AND / OR REUSED RESULTING FROM REMOVAL OPERATIONS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. ALL COSTS IN CONNECTION WITH D159051NG OF THE MATERIALS WILL 6E AT THE CONTRACTOR'S EXPENSE. ALL LIABILITY OF ANY NATURE RESULTING FROM THE DISPOSAL OF THE MATERIALS WILL BE THE RESPONSIBILITY OF THE CONTRACTOR 6. CONTRACTOR SHALL PROVIDE AND MAINTAIN ACCESS TO ALL EXISTING FACILITIES AND THOSE UNDER CONSTRUCTION IN THE IMMEDIATE VICINITY, AT ALL TIMES DURING CONSTRUCTION OF PROPOSED PROJECT. 7. CONTRACTOR SHALL INSTALL SECURITY FENCING AND BARRICADES AS REQUIRED BY THE LOCAL AUTHORITIES, AND/OR DIRECTED BY ARCHITECT / ENGINEER 0. VERIFICATION OF EXISTING CONDITIONS: EACH CONTRACTOR SHALL DETERMINE AND VERIFY ALL DIMENSIONS AND CONDITIONS AT THE BUILDING 51TE AND SHALL BE RESPONSIBLE FOR SAME BEFORE COMMENCING THE WORK DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT AND/OR ENGINEER AND SHALL BE RESOLVED BEFORE RESUMING THE WORK DIMENSIONS SHALL BE READ AND NEVER SCALED OR ESTIMATED FROM THE ARCHITECTURAL DRAWINGS. 9. CODE COMPLIANCE: EACH CONTRACTOR SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE 2001, AND WITH ALL OTHER CODES AND GOVERNMENTAL AGENCIES HAVING JURISDICTION OVER HIS PORTION OF THE WORK EACH CONTRACTOR SHALL BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES AND FOR SAFETY PRECAUTION AND PROGRAMS IN CONNECTION WITH H15 PORTION OF THE WORK 10. EXAMINATION OF THE CONTRACT DOCUMENTS AND SITE: EACH CONTRACTOR FOR TH15 PROJECT SHALL STUDY AND FAMILIARIZE HIMSELF WITH THE 51TE AND WITH ALL THE DRAWINGS FOR ALL TRADES AND PARTS OF THE WORK SHOULD ANY CONTRACTOR HAVE THE OPINION THAT THERE EXISTS IN THE ARCHITECTURAL DRAWINGS ANY ERRORS OR DISCREPANCIES, OR THAT CONDITIONS OF THE WORK OF ANY OTHER CONTRACTOR 15 SUCH THAT IT WILL PREVENT HIM FROM COMPLETING H15 WORK IN A COMPETENT MANNER HE SHALL NOTIFY THE ARCHITECT OF SUCH BEFORE PROCEEDING WITH H15 WORK THE CONTRACTOR SMALL HAVE AT THE BUILDING SITE, FROM START TO FIN19H OF CONSTRUCTION, A RESPONSIBLE FOREMAN. IN ADDITION, THE CONTRACTOR SHALL GIVE H15 PER50NAL SUPERVISION TO THE WORK THE FOREMAN SHALL BE ON DUTY DURING ALL WORKING HOURS. ANY INSTRUCTIONS OR NOTICES GIVEN TO HIM SHALL HAVE THE SAME IMPORTANCE AS IF GIVEN TO THE CONTRACTOR IN PERSON. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND MAINTAINING TEMPORARY PROVISIONS SUCH AS TOILETS, WATER SUPPLY, LIGHT AND POWER AS WELL AS ANY OTHER DEEMED NECESSARY FOR THE COMPLETION OF THE BUILDING. ANY ITEM OF WORK NECE65ARY TO THE PROPER COMPLETION OF CONSTRUCTION WHICH IS NOT SPECIFICALLY COVERED IN THESE DOCUMENTS SHALL BE PERFORMED IN A MANNER DEEMED GOOD PRACTICE OF THE TRADE INVOLVED. 11. PERMITS, FEES AND TAXES: THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS, FEES LICENSES AND DEPOSITS AND BE LIABLE FOR ALL STATE AND FEDERAL SALES TAXES, AND ALL OBLIGATION UNDER THE FEDERAL SECURITY ACT. UPON COMPLETION OF THE PROJECT, THE CONTRACTOR SHALL OBTAIN CERTIFICATES OF COMPLIANCE, APPROVAL OR ACCEPTANCE FROM ALL AUTHORITIES HAVING JURISDICTION OVER THE WORK AND DELIVER THESE CERTIFICATES TO THE OWNER ALONG WITH OFFICIAL RECEIPTS FOR SAME. 12. PERFORMANCE OF WORK: NO SUBCONTRACTOR SHALL BEGIN HIS WORK UNLESS THE PREvIOUS TRADES, UPON WHOM HE IS DEPENDENT, HAS PERFORMED THEIR WORK SATISFACTORILY ACCORDING TO THE PLANS AND SPECIFICATIONS. ONCE THE CONTRACTOR HAS STARTED PIS Lxl; iK, HE ASSUMES FULL RESPONSIBILITY FOR THAT WORK, 50TH FOR MATERIALS AND LABOR PERFORMED. ALL SUBCONTRACTORS ARE RESPONSIBLE FOR REMOVING DEBRIS RESULTING FROM THEIR WORK FROM THE PREMISES. 13. CLEANUP: IN ADDITION TO THE REMOVAL OF ALL CONSTRUCTION DEBRIS FROM THE PREMISES, IT 15 THE FINAL RESPONSIBILITY OF THE CONTRACTOR TO REMOVE ALL SMUDGES, SPOTS OF PLASTER PUTTY, CAULKING COMPOUND, ADHESIVE, PAINT AND PENCIL MARKINGS, TAGS AND DESTINATION LABELS NOT CALLED FOR AS BEING PERMANENT, THE CONTRACTOR SHALL ALSO GLEAN EACH AREA SEPARATELY, INCLUDING THE WASHING OF ALL WINDOWS AND VACUUMING OR WAXING OF ALL FLOORS, PRIOR TO HANDING THE COMPLETED PROJECT OVER TO THE OWNER 14. MATERIALS: ALL MATERIALS SHALL BE NEW, AS CALLED FOR IN THE DRAWINGS, AND THE BEST OF THEIR RESPECTIVE KINDS. NO SUBSTITUTIONS SHALL BE MADE BY THE CONTRACTOR WITHOUT PRIOR WRITTEN APPROVAL BY THE OWNER, UNLE55 SPECIFIED OTHERWISE ON THE DRAWINGS. FOR PORTIONS OF THE WORK NOT SHOWN IN DETAIL, BUT WHICH ARE SHOWN GENERALLY, OR ARE REA5ONA5LY INFERABLE AS BEING REQUIRED FOR A COMPETENT AND COMPLETE INSTALLATION, THE MATERIAL METHODS AND WORKMANSHIP SHALL CONFORM AS A MINIMUM TO THE TYPICAL OR REPRESENTATIVE. 15. FIRE RESISTANCE / UNDERWRITERS LABORATORY RATINGS: WHERE ASSEMBLIES OR THEIR VARIOUS COMPONENTS, MATERIALS OR CONSTRUCTION SYSTEMS ARE INDICATED TO HAVE FIRE RESISTANCE RATINGS / UNDERWRITERS LABORATORY RATINGS., ALL SUCH SHALL BE COMPOSED OF MATERIALS AND BE ASSEMBLED 50 AS TO CONFORM TO THE STANDARDS ESTABLISHED IN GOVERNING CODES IN ORDER TO ACHIEVE THE REQUIRED RATING IN THE COMPLETED WORK 16. CUTTING AND PATCHING: EACH CONTRACTOR SHALL BE RESPONSIBLE FOR ANY CUTTING, FITTING, PATCHING AND MATCHING OF HIS NEW WORK TO EXISTING WORK WHERE APPLICABLE AND INDICATED N THE DRAWINGS. NO CONTRACTOR SHALL ENDANGER ANY WORK OF ANY OTHER CONTRACTOR BY EXCAVATING CUTTING OR OTHERWISE ALTERING ANY WORK OF ANY OTHER CONTRACTORS. 11. DEMOLITION: THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DEMOLITION AND REMOVAL OF DEBR15 REQUIRED TO COMPLETE THE CONSTRUCTION AS SPECIFIED ON THE DRAWINGS, EXISTING UNUSED ELECTRIC AND PLUMBING SHALL BE REMOVED OR ADEQUATELY CAPPED AS ALLOWED BY CODE, 2430'xl/4' GLASS MIRROF LAY (MIN COVER ALL PIPES IF HO IS PROVIDED 20" :36' 6.6. GRAB AT I-O' FROM HANxaP WATERCLOSET WALL 2 KEY PLAN SCALE:NTS APAWENT BUILDING OCCUPANCY ABOVE 3-5/8' MTL. STUDS BRACING 6 4'-O' O.G. AS REQ, METAL STUD FIRE ST EXTEND STEEL STUDS TO BOTTOM OF SLAB BOTTOM OF EXISTING SLAB ELEV. VARIES FIN. GLG. ELEV. SEE REFLLG.PLAN FINISH CEILING SEE REFLECTED CEILING PLAN 3 5/8' OR 6' METAL STUDS AT 16' O/C (MINIMUM 25 GAGE) PROVIDE MOISTURE RESISTANT GYPSUM BOARD 0 ALL TOILETS ROOMS 5/8' STUD PAINTED DRYWALL BOTH SIDES PTD. COLOR TO BE SELECTED METAL STUD BRACING AS REQUIRED (MAXIMUM 4'-O' G/G) FASTEN BOTTOM OF STUDS TO FLOOR STRUCTURE W/2 * 10 GA SCREWS B 48' O.G. (TYP. 7HROUGHT) BASE -SEE FIN. SCHEDULE FIN16H FLOOR 3 PROPOSAL FLOOR PLAN SCALE: 1 1/2"=1'-0" I.1/2'x36' BAR AT I HANDCAP WATERGLO 1'-1' 41 3'-2' CORRIDOR Ai �---�� - COFFE GABINET :n io 60FIM • v EAM LEGEND NEW PARTITION ,4��� EXISTING WALL 70 REMAIN NEW GBS WALL ERCANTIL ONE HOUR FIRE (OCCUPANCY RATED PARTITION C�j� COMMERCIAL RETAIL NEW PARTITION IR ETAI L fi Q NEW PARTITION I HR FIRE RATED U_ l ,�d ��� . EX DENOTES EXISTING DOOR TO REMAIN �' �4 �4•�' ain t�acl�0cY►� ��,r O 1 EX DENOTES EXISTING WINDOW TO REMAIN r 0t4PL'f �. J l L.:J ! �. 1 � :, f i H' L... v� Vi'sibk� OF NG OCCUPANCIIIE4. ��'>"�f>'RYFt'{3N Ti*rW R DA FiRF PREW1141104 IODF, 2' ter. r�p A EX PROPOSAL FLOOR PLAN STREET AGCE 5 8``''' 1 SCALE:1/4"=1'-0° FtiP.su�,?�%��� - 2 O 3'0 .yu�p�� D G.H. ► 8'-0' 3'm 3'p IRG GO '' F � . ' 13 FIRE I'm WOF2Y.cN �N,AIL � `" p•8 511�;�IT-i ED _ FIR .� � F�P'�`--�' `� RTtJ�NT SYBT FOR�3rA Is iN Y~FtRQ a ,TF.11-E NA". A 2 PROPOSAL REFLECTED CEILING PLAN + SPRINKLER LAYOUT SCALE: 1 /4"=1'-0" KEY NOTES No. DESCRIPTION REFER 2'x4' FLUORE6GENTE LIGHT FIXTURE SEE ELECTRICAL PLANS 2'x2' fLUORE6CENTE LIGHT FIXTURE SEE ELECTRICAL PLANS 2'x4' AC4:OJSTICAL TILE ON SUSPENDED METAL GRID C> 2'4' ACCCUSTICAL TILE ON SUSPENDED METAL GRID SPRINKLER LEGEND O EXISTING SPRINKLER HEAD EXIST. SPRINKLER PIPE 5Y5TEM NO. W=L=5214 1 SEPTEMDER 19, 2003 F RATING - 1 AND 2 HP. (5EE ITEM 6) T RATING - 1/2 HR. A SECTION A -A 1. WALL ASSEMBLY - THE 1 OR 2 HR. FIRE -RATED GYPSUM WALLBOARD/STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER DESCRIBED IN THE INDIVIDUAL U300 OR U400 SERIES WALL OR PARTITION DESIGN IN THE UL FIRE RESISTANCE DIRECTORY AD SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES: A. STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN. LUMBER SPACED 16 IN. OC WITH NOM 2 BY 4 IN. LUMBER END PLATES AND CROSS BRACES. STEEL STUDS TO BE MIN 3-5/8 IN. WIDE AND SPACED MAX 24 IN. OC. B. GYPSUM BOARD* - 5/8 IN. THICK, 4 FT WIDE WITH SQUARE OR TAPERED EDGES. THE GYPSUM WALLBOARD TYPE, THICKNESS, NUMBER OF LAYERS, FASTENER TYPE AND SHEET ORIENTATION SHALL BE AS SPECIFIED IN THE INDIVIDUAL U300 OR U400 SERIES DESIGN IN THE UL FIRE RESISTANCE DIRECTORY. MAX DIAM OF OPENING IS 7 IN. THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS EQUAL TO THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED. 2. THROUGH PENETRANT - ONE METALLIC PIPE OR TUBING TO BE INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. PIPE OR TUBING TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF METALLIC PIPES OR TUBING MAY BE USED: A. STEEL PIPE - NOM 4 IN. DIAM (OR SMALLER) SCHEDULE 10 (OR HEAVIER) STEEL PIPE, B. IRON PIPE - NOM 4 IN. DIAM (OR SMALLER) CAST OR DUCTILE IRON PIPE. C. COPPER TUBING - NOM 4 IN. DIAM (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBING. D. COPPER PIPE - NOM 4 IN. DIAM (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE. 3. TUBE INSULATION -PLASTICS#- - NOM 3/4 IN. THICK ACRYLONITRILE BUTADIENE/POLYVINYL CHLORIDE (AB/PVC) FLEXIBLE FOAM FURNISHED IN THE FORM OF TUBING. THE ANNULAR SPACE BETWEEN THE INSULATED THROUGH PENETRANT AND THE PEROPHERY OF THE OPENING SHALL BE A MIN OF 0 IN. (POINT CONTACT) TO A MAX 1-1/4 IN. SEE PLASTICS+ (OMFZ2) CATEGORY IN THE PLASTICS COMPONENT DIRECTORY FOR NAMES OF MANUFACTURERS, ANY RECOGNIZED COMPONENT TUBE INSULATION MATERIAL MEETING THE ABOVE SPECIFICATIONS AND HAVING A UL94 FLAMMABILITY CLASSIFICATION OF 94-5VA MAY BE USED. 4. FIRESTOP SYSTEM - THE FIRESTOP SYSTEM SHALL CONSIST OF THE FOLLOWING: A. FORMS - USED TO PREVENT LEAKAGE OF FILL MATERIAL DURING INSTALLATION IN 2 HR FIRE -RATED WALL ASSEMBLIES. FORMS TO BE RIGID SHEET OR POLYURETHANE BACKER ROD, CUT TO FIT THE CONTOUR OF THE PENETRATING ITEM AND FRICTION FITTED INTO OPENING ON BOTH SIDES OF WALL. FORMS TO BE RECESSED FROM BOTH SURFACES OF WALL AS REQUIRED TO ACCOMMODATE THE REQUIRED THICKNESS OF FILL MATERIAL. B. FILL, VOID OR CAVITY MATERIALS* - SEALANT - MIN 5/8 IN. THICKNESS OF FILL MATERIAL APPLIED WITHIN THE ANNULUS, FLUSH WITH BOTH SURFACES OF WALL, AT THE POINT CONTACT LOCATION BETWEEN INSULATED THROUGH PENETRANT AND GYPSUM WALLBOARD, A MIN 3/8 IN. DIAM BEAD OF FILL MATERIAL SHALL BE APPLIED AT THE GYPSUM WALLBOARD/INSULATED THROUGH PENETRANT INTERFACE ON BOTH SURFACES OF WALL. EGS NELSON FIRESTOP - LBS3 SEALANT *BEARING THE UL CLASSIFICATION MARK #BEARING THE UL RECOGNIZED COMPONENT MARK `'�►•aa, Gaf f Gt,f •J 0 ^W H H O W-I � Nw w F-i-I o� . O t`- W U Fq H ►� O project no. date: OB V ELEVATION 1 SCALE : 1/2' = 1'-0' ELEVATION 2 SCALE : 1/2' 2 1'-0'