Loading...
06-1789-018EXISTING 3#4 & 1#8 GND IN 1-1/4"C TO EXISTING 200A, 208V, NEMA 3R NE DISC❑NNECT SWITCH ❑N ROOF NI EXISTING RETAIL SERVICE DISC❑NNECT AT 1000A, 120/240V, 3PH, 4W EXISTING (3)#3/0, /11++1 In CINITI TINI '7/Ir q EXISTING (2)SETS OF 3#1500MCM THWN ALUM, & 1#350MCM THWN CU 4" PVC EACH SET OR (2)SETS OF 4*350MCM THWN CU 4" PVC EACH SET EXSTG WIREWAY M1 � M3 M4 M5 M6 M7 u u u u XISTING METER & XISTING 2" PVC TUBBED UP FOR UTURE RETAIL PACE u CONTRACTOR PR❑VIDE & INSTALL NEW WIRE & C❑NDUIT FOR NEW NEW NEW PANEL IN C❑MMERCIAL BAY #105 & 106 PANE PANE R5 R6 NEW 100A NEW 100A 120/208V 120/208V 3PH, 4W 3PH, 4W L,.ISTING (2)SETS ❑E 3#k3/0 & 1II3/0 IN 2"C EACH SET TO EXISTING MAIN CKT, BRI<R, N❑, 2 AT EXISTING METER RM N❑,3 ELECTRICAL ONELINE RISER DIAGRAM SCALE: NTS ELECTRICAL SYMBOL LEGEND SYMBOL DESCRIPTION !-- C FLUORESCENT STRIP FIXTURE FIXTURE DESIGNATION —A FLUORESCENT FIXTURE CIRCUIT NUMBER —2 a LOWER CASE LETTER INDICATES CONTROL CIRCUIT SWITCH LEG ®FLUORESCENT FIXTURE DIAGONAL SHADING DENOTES EMERGENCY LIGHT FIXTURE. FLUORESCENT WALL MOUNTED FIXTURE WITH WALL OUTLET BOX Q HID, FLUORESCENT, OR INCANDESCENT FIXTURE EXIT LIGHT FIXTURE DIRECTION ARROWS AS SHOWN (SHADED QUADRANT INDICATES FACE(S) OF FIXTURE) TRACK WITH TRACK LIGHT FIXTURE (TRIANGLES INDICATE QUANTITY OF LIGHT FIXTURES) BATTERY PACK WITH TWIN HEADS q TELEPHONE DATA OUTLET TV TELEVISION SIGNAL WALL OUTLET AUDIO/VISUAL SIGNALLING UNIT CD = CANDELA RATING MTD 80" AFF, OR 6" BELOW CEILING, WHICHEVER IS LOWER SD CEILING SMOKE DETECTOR, PHOTO -ELECTRIC TYPE UNLESS OTHERWISE NOTED Qr= DUPLEX RECEPTACLE $a SINGLE POLE SWITCH (SUBSCRIPT INDICATES ITEM CONTROLLED) $3 THREE-WAY SWITCH L[:-] 3 0 A R NON -FUSED DISCONNECT SWITCH, SIZE do # OF POLES NF NF DENOTES NON -FUSED AR DENOTES AMP RATING OF SWITCH EXISTING TO REMAIN NEW my -a _ BRANCH CIRCUIT PANELBOARD FLUSH MOUNTED BRANCH CIRCUIT CONDUIT CONCEALED ABOVE CEILING OR IN WALL. CONDUIT SHALL INCLUDE PHASE, NEUTRAL AND GROUND CONDUCTORS AS REQUIRED FOR CIRCUITS (UNLESS OTHERWISE NOTED), NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT. GENERAL ELECTRICAL RENOVATION NOTES: 1. THE NATURE OF THIS CONTRACT INVOLVES EXTENSIVE REMODEL '� Or EXISTING FACILITIES. THE ELECTRICAL CONTRACTOR, PRIOR TO BID, SHALL INSPECT THE EXISTING CCND TIONS AT TH- JOB SITE AND ACQUAINT HIMSELF WITH WITH THE CONDITIONS THAT WILL AFFECT HIS WORK. 2. PRIOR TO ROUGH -IN, THIS CONTRACTOR SHALL COORDINA-= H S V,'CRK WITH THE ACTUAL EQUIPMENT BEING FURNISHED. 3. PRESENT ELECTRICAL EQUIPMENT WHERE INDICATED ON T-- DRAWINSS OR WHERE THE INSTALLATIONS WILL INTERFERE WITH THE INSTALLATION OF NEW EQU'DUENT OR NEW ARC- TEC+-RA_ CHANGES, SHALL BE REMOVED, RELOCATED, OR RE-ROUTED TO PERMIT COMPLETETION OE SUCH WORK, 4. SALVAGED MATERIALS, EQUIPMENT, AND LIGHT FIXTURES S-ALL 3E DELIVERED -0 THE OWNER AT HIS PROPERTY AND STORED WITHIN THE BUILDING WHERE DIRECTED. ANY REMOVED ')',A-`RIALS OR EQUIPMENT WHICH THE OWNER DOES NOT WISH TO KEEP SHALL BE DISPOSED OF BY THE CON-RACTCR, W THOUT ADD TIONAL COST TO THE OWNER, 5. ALL PRESENT CONDUIT IN EXISTING AREAS TO BE ALTERED, WI- C- N _L HAVE NO USE UPON COMPLETION OF THE ALTERATIONS SHALL BE REMOVED. WHENEVER CONDUITS ARE CR V,' �-'_ BECOME EXPOSED TO VIEW, OR WILL INTERFERE WITH THE INSTALLATION AND COMPLETION OF THE WORK SHALL ALSO BE REMOVED, 6. THE ELECTRICAL CONTRACTOR SHALL DETERMINE T PIE EX -ENT -0 CH EXISTING CONDUIT AND THE WIRING WILL HAVE TO BE RE-ROUTED, RELOCATED, OR RECONNECTED, AND --- A�1C \- OF ADDITIONAL WORK WHICH MAY BE REQUIRED DUE TO THE PHYSICAL CONDITIONS 0= THE CQND,'' T AND BE PERFORMED UNDER THIS CONTRACT WITHOUT ADDITIONAL CHARGES TO THE OWNER, 7. CONDUIT SHALL NOT BE RUN EXPOSED THROUGH EXISTING OR '`_'� ^ NISHED SPACE UNLESS WRITTEN PERMISSION IS GRANTED BY THE OWNER. 8. INTERRUPTION OF EXISTING FACILITIES OR SERVICES SHAL_ BE �_=- TO A MINIMUM AND THE CONTRACTOR SHALL FURNISH ALL MATERIALS AND LABOR REQUIRED V,'=ENEVER-EM:-CRARY CONDITIONS ARE NECESSARY TO MAINTAIN CONTINUITY OF SERVICE. INTERRUPTION OF SFRV;CES, TH- 'NS-.�-__ATION OF TEMPORARY FACILITIES, AND THE WORK OF MAKING FINAL CONNECTIONS TO NEW WORK SHALL BE :ONE C\_Y AT SUCH TIMES AS PERMITTED AND SCHEDULED BY THE OWNER WITHOUT ADDITIONAL COST. THE='_ECTRIC-'_ CC%`�ACTOR SHALL BE RESPONS'BLE TO COORDINATE THE SERVICE INTERRUPTIONS WITH THE OWNER AND GENERAL CONTRA, -GR. GENERAL NOTES: 1. LIGHT SWITCHES SHALL BE MOUNTED 4E INCHES ABOVE FINISHED FLOOR TO CENTER LINE OF DEVICE, UNLESS OTHERWISE NOTED. 2. RECEPTACLES SHALL BE LOCATED 18 INCHES ABOVE FINISHED FLOOR TO CENTER LINE OF DEVICE, UNLESS OTHERWISE NOTED. ABOVE -COUNTER RECEPTACLES SHALL BE MOUNTED 6" ABOVE BACK SPLASH TO CENTFRHNE OF DEVICE, 3. EQUIPMENT SHALL BE OF MATERIALS SUITABLE FOR AND RATED FOR THE ENVIRONMENT IN WHICH THEY ARE TO BE INSTALLED. 4. A. WORKING CLEARANCES FOR ELECTRICAL EQUIPMENT SHALL BE IN COMPLIANCE WITH NEC 110. B. THE EXCLUSIVELY -DEDICATED SPACE EXTENDING FROM FLOOR TO STRUCTURAL CEILING WITH A WIDTH AND DEPTH OF THE PANFLBOARD OR SWITCHBOARD MUST BE CLEAR OF ALL PIPING, DUCTS OR EQUIPMENT FOREIGN TO THE ELECTRICAL EQUIPMENT OR ARCHITECTURAL APPURTENANCES IN ACCORDANCE WITH NEC 408. 5. WHEN ELECTRICAL BOXES ARE LOCATED IN VERTICAL FIRE -RESISTIVE ASSEMBLIES, (CLASSIFIED AS FIRE/SMOKE AND SMOKE PARTITIONS), THEY SHALL BE INSTALLED WITHOUT AFFECTING THE FIRE CLASSIFICATION. ALL OF THE FOLLOWING CONDITIONS SHALL BE MET: A. ALL ELECTRICAL BOXES SHALL BE METALLIC. B. BOX OPENING SHALL OCCUR ONLY ON ONE SIDE OF FRAMING SPACE. C. BOX OPENING SHALL NOT EXCEED 16 SQUARE INCHES. D. ALL CLEARANCES BETWEEN OUTLET BOX AND GYPSUM BOARD SHALL BE COMPLETELY FILLED WITH JOINT COMPOUND (OR OTHER APPROVED E. �f���L WALL AROUND OUTLETS LARGER THAT 16 SQUARE INCHES. THE INTEGRITY OF THE WALL RATING SHALL BE MAINTAINED. F. THE TOTAL AGGREGATE SURFACE AREA OF THE BOXES SHALL NOT EXCEED 100 SQUARE INCHES PER 100 SQUARE FEET. G. OUTLET BOXES LOCATED ON OPPOSITE SIDES OF FIRE --RESISTIVE ASSEMBLIES SHALL BE SEPARATED BY A MINIMUM HORIZONTAL DISTANCE OF H. 66IIM&ES SHALL BE SECURELY FASTENED TO WALL FRAMING MEMBERS. L THE OPENING IN THE GYPSUM BOARD FACING SHALL BE CUT NOT TO EXCEED 1/8 INCH BETWEEN THE EDGES OF THE OUTLET BOX AND THE EDGES OF THE OPENING. 6. ALL DEVICES SHALL BE MOUNTED VERTICAL, UNLESS OTHERWISE NOTED. 7. ALL RECEPTACLES SHALL BE MOUNTED SUCH THAT THE GROUND PIN IS MOUNTED DOWN. 8- THE NUMBER OF ARROWHEADS ON THE HOMERUNS DENOTES THE NUMBER OF CIRCUITS. GENERAL ELECTRICAL DEMOLITION NOTES: 1. WITHIN THE AREA IDENTIFIED, UNLESS SPECIFICALLY NOTED OTHERWISE, CONTRACTOR SHALL DISCONNECT AND REMOVE ALL EXISTING UNUSED ELECTRICAL EQUIPMENT INCLUDING BUT NOT LIMITED TO LIGHTING FIXTURES, WIRING DEVICES, PANELBOARDS, MOTOR CONNECTIONS AND ASSOCIATED CONTROLS, ETC. REMOVE ALL UNUSED WIRING COMPLETELY INCLUDING CONDUIT AND CONDUCTORS BACK TO POWER SOURCE OR NEXT ACTIVE OUTLET. WHERE CONDUIT IS INACCESSIBLE, REMOVE CONDUCTORS AND CUT BACK CONDUIT FLUSH WITH SLAB OR WALL. PATCH OPENING TO MATCH EXISTING FINISH. WHERE EXISTING WIRING EXTENDS OUTSIDE OF THE AREA BY NATURE OF THE ORIGINAL INSTALLATION, CONTRACTOR SHALL MODIFY EXISTING WIRING AS REQUIRED TO MAINTAIN CONTINUITY OF EXISTING CIRCUITRY SUCH THAT NO EQUIPMENT TO REMAIN IS LEFT WITHOUT SERVICE. 2. ALL REMOVED ITEMS SHALL BECOME THE PROPERTY OF THE CONTRACTOR WITH THE APPROVAL OF THE OWNER AND SHALL BE REMOVED FROM THE SITE. 3. THE CONTRACTOR SHALL VISIT THE SITE AND EXAMINE THE EXISTING CONDITIONS PRIOR TO COMMENCING WORK AND SHALL NOTIFY THE ARCHITECT AND/OR ENGINEER IF A CONDITION EXISTS WHICH PREVENTS HIM FROM ACCOMPLISHING THE WORK INDICATED AND INTENDED BY THESE DRAWINGS, 4. PRIOR TO BID, THE EXTENT AND UNDERSTANDING OF THE WORK TO BE PERFORMED SHALL BE CLEARLY ESTABLISHED SUCH THAT NO ADDITIONAL COSTS WILL BE INCURRED BY THE OWNER. ANY WORK, OTHER THAN AS DESCRIBED ON ANY ITEM OR SYSTEMS SHALL BE QUALIFIED WITH THE BID. THESE DRAWINGS REQUIRED TO PROVIDE AND INSTALL 5. PRIOR TO COMMENCING WORK, CONTRACTOR SHALL DISCONNECT POWER IN THE DEMOLITION AREA INCLUDING POWER FOR THE LOW -VOLTAGE SYSTEMS SUCH AS FIRE ALARM, CONTROL WIRING, ETC. 6. CONTRACTOR SHALL EXERCISE EXTREME CAUTION DURING DEMOLITION WORK. EXISTING FEEDERS AND PANELS ARE SHOWN SCHEMATIC FOR REFERENCF PURPOSES ONLY. CONTRACTOR SHALL VERIFY IN FIELD ROUTING OF ALL EXISTING FEEDERS PRIOR TO DEMOLITION. 7. CONTRACTOR SHALL PROVIDE TEMPORARY POWER WHERE REQUIRED DURING DEMOLITION AND CONSTRUCTION SCOPE OF WORK. 8. ALL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR AND SHALL BE COORDINATED WITH OTHER TRADES. 9. CONTRACTOR SHALL PROVIDE ALL REQUIRED INSURANCE FOR PROTECTION AGAINST PUBLIC LIABILITY FOR THE DURATION OF THE WORK. 10. CONTRACTOR SHALL PAY FOR THE PERMITS, FEES do INSPECTIONS. 40 N M AN AVE AMA , R" n 492 FAX 306N ON cwnMr 7M NQ AAR EMMANUEL O. UCHE, AIA LIG NO: AR-0015315 CONSULTANTS: U Z Z C7 Q, Ms c" �pLA- I— (GR ^ © -�E W z�o po 5 V ¢ OLu U v ^ z zC-4 "—` Luin i� ZZ � .. Vc� Z zLl 2: g L.0 ,^ V) W r- 0 0 z W m a� Z M M W Q J V W O oC E[ .j 0 U LL. o U m c� W W = w >— J cry � O tz tie zo r- 0 0 �O PROJECT NO: ???? DRAWN IY: WAW REVIEWED FY: DA APPROVED BY: DA DATE- 08/09/2006 REVISION DATES: