06-1789-015PLUMBING FIXTURE SCHEDULE PLUMBING SYMBOL LEGEND GENERAL NOTES SYMBOL DESCRIPTION SYMBOL DESCRIPTION 1. REFERENCE THE SPECIFICATIONS FOR MATERIAL AND EQUIPMENT INSTALLATION STANDARDS. WALL WCO WALL CLEANOUT COATED CAST IRON BODY CLEANOUT TEE, WITH GAS AND WATERTIGHT TAPERED CD - ABOVE GROUND CONDENSATE DRAIN - SHUTOFF VALVE 2. THE PLUMBING INSTALLATION SHALL COMPLY WITH ALL STATE AND LOCAL CODES. THREAD PLUG AND ROUND, SMOOTH STAINLESS STEEL WALL ACCESS COVER WITH - DOMESTIC COLD WATER - CHECK VALVE (SWING) 3. UTILITIES AND SERVICES INDICATED ARE TAKEN FROM VARIOUS OLD AND NEW SECURING SCREW. BASIS OF DESIGN S - ABOVE GROUND SANITARY - - PRESSURE REDUCING VALVE SURVEYS, AS -BUILT RECORDS AND FIELD INVESTIGATIONS. UNFORSEEN CONDITIONS PROBABLY EXIST AND NEW WORK MAY NOT RE FIELD LOCATED EXACTLY AS SHOWN ON ZURN - Z-1441 5 -BELOW GROUND SANITARY - GAS COCK DRAWINGS, COOPERATION WITH OTHER TRADES IN ROUTING AND BURIAL DEPTHS, AS DETERMINED DURING CONSTRUCTION, WILL BE NECESSARY. - SANITARY VENT FC - SHUTOFF VALVE ON RISER WC FLOOR MOUNTED ACCESSIBLE WATER CLOSET 4. FIELD VERIFY EXISTING INSTALLATIONS. MODIFY EXISTING PLUMBING SYSTEMS, 16-1/2" HIGH, VITREOUS CHINA, 1.6 GALLON, FLOOR MOUNTED TANK WATER CLOSET, - Hi C HOSE 1111 OR WALL HYDRANT '� -GAS COCK ON RISER WHICH ARE TO REMAIN ACTIVE, 70 FACILITATE RECONNECTION AND EXTENSION OF SIPHON JET. CO Ii CLEAN OUT PLUG - CONNECTION, TOP THE NEW WORK. SEAT SHALL BE EXTRA HEAVY SOLID PLASI1C WITH STAINLESS STEEL SELF SUSTAINING CO I I 0 - WALL CLEANOUT - CONNECTION, BOTTOM 5. NOTIFY OWNER AT LEAST 24 HOURS PRIOR TO INTERRUPTING EXISTING SERVICE. CHECK HINGE, OPEN FRONT LESS COVER. CO - FLOOR CLEAN OUT 0 - ELBOW, TURNED DOWN SCHEDULE DISCONNECTION AND TIE-INS TO MINIMIZE DISRUPTION OF SERVICES, 1/2"- COMPRESSION X 1/2" OD CHROME PLATED ANGLE SUPPLY STOP WITH CHROME 1/2C SERVICES ARE NOT TO BE LEFT DISRUPTED DURING NON -NORMAL CONTRACTOR WORKING 12" FLEXIBLE RISER AND ESCUTCHEON. -ELBOW, TURNED UP HOURS. NOTE: FLUSH HANDLE SHALL FACE WIDE SIDE OF STALL - TEE, TURNED UP 6. PLANS ARE NOT COMPLETELY TO SCALE. PIPE ROUTING SHOWN IS SCHEMATIC AND IS BASIS OF DESIGN -- - TEE, TURNED DOWN NOT INTENDED TO INDICATE EXACT ROUTING. CONTRACTOR SHALL PROVIDE ANY ADDITIONAL OFFSETS AND FITTINGS REQUIRED FOR PROPER INSTALLATION AND TO CHINA -AMSTANDARD AMERICAN STANDARD - 2R88.012 -CAP MAINTAIN CLEARANCES, VERIFY STRUCTURAL, MECHANICAL AND ELECTRICAL INSTALLATIONS SEAT - 8EM- C -REVISION REFERENCE AND OTHER POTENTIAL OBSTRUCTIONS AND ROUTE PIPING TO AVOID INTERFERENCES. SUPPLY - MCGUIRE - H2169 © ACCESSIBLE WALL HUNG LAVATORY 7. PROVIDE ALL OFFSETS AND FITTINGS AND MAKE CONNECTION TO SITE UTILITIES. VITREOUS CHINA LAVATORY, 20" X 18", PUNCHED FOR SINGLE HOLE FITTING AND 8. CONCEAL PIPING ABOVE CEILINGS, WITHIN WALLS OR CHASES EXCEPT IN MECHANICAL CONCEALED ARM CARRIER SUPPORT. ROOMS OR AS SPECIFICALLY NOTED. 4" CENTERSET CHROME PLATED BRASS FAUCET WITH SINGLE LEVER HANDLE, VANDAL RESISTANT 0.5 GPM FLOW REGULATOR. 9. PROVIDE ACCESS PANELS FOR ALL VALVES CONCEALED IN WALLS OR ABOVE PRE -INSULATED CHROME PLATED WHEELCHAIR LAVATORY STRAINER, CAST GRID DRAIN NON -ACCESSIBLE CEILINGS. PLUG WITH STRAINER AND OFFSET DRAIN ASSEMBLY WITH 1-1/4 INCH O.D. TAILPIECE, CHROME PLATED 17 GAUGE 1-1/4 X 1-1/2" BRASS P-TRAP WITH CLEANOUT. 10. SLEEVE AND/OR FIRESTOP ALL PENETRATIONS THROUGH RATED WALLS, CEILINGS, AND FLOORS WITH U/L LISTED ASSEMBLIES. FIRESTOP ASSEMBLIES SHALL BE EQUAL TO OR PRE -INSULATED 1/2" COMPRESSION X 3 i INCH COMPRESSION CHROME PLATED ANGLE EXCEED THE RATING OF THE WALL, CEILING OR FLOOR. SEE ARCHITECTURAL DRAWINGS SUPPLY STOPS WITH CHROME PLATED 12" FLEXIBLE RISERS AND ESCUTCHEONS. FOR FINAL FINISHES. FULLY ADJUSTABLE LAVATORY CARRIER ADJUSTED TO ACCESSIBLE HEIGHT, SEE SPECS. BASIS OF DESIGN 11. FLASH AND COUNTER -FLASH ROOF PENETRATIONS. CHINA - AMERICAN STANDARD - 0356.012 12, WHEN BEAM SLEEVE PENETRATIONS ARE NECESSARY, COORDINATE PENETRATIONS WITH FAUCET - CHICAGO 2200-4-E2605 ALL TRADES, THE ARCHITECT AND THE STRUCTURAL ENGINEER. STRAINER/TRAP/STOPS - MCGUIRE - 2125WC CARRIER - ZURN ZR-1200 SERIES 13, PROVIDE FOUNDATION PAD PENETRATION SLEEVES. ALLOW 1" MINIMUM CLEARANCE BETWEEN SLEEVE INSIDE SURFACE AND PIPE EXTERIOR. 14. SEE ARCHITECTURAL DRAWINGS FOR FIXTURE LOCATIONS AND MOUNTING HEIGHTS. PLUMBING ABBREVIATIONS SPECIFICATIONS 15. PROVIDE AUTOMATIC TRAP PRIMERS FOR FLOOR DRAIN TRAP SEALS. SYMBOL DESCRIPTION 16. PROVIDE AN AIR GAP, WHEN REQUIRED BY CODE, SERVING INDIVIDUAL FIXTURES, QFF - BELOW FINISH FLOOR IE - INVERT ELEVATION DEVICES, APPLIANCES AND APPARATUS. CD - CONDENSATE DRAIN NTS - NOT TO SCALE QUALITY: 17. ALL EXPOSED PIPE AND FILLINGS IN FINISHED AREAS SHALL RE CHROME PLATED. S - SANITARY CO - C CLEANOUT CLEAN SF - SQUARE FEET CONT - UATION PLUMBING FIXTURES SHALL BE "FIRST QUALITY" AS DEFINED AND SET FORTH 11. MOUNT HOSE IIIBS 24" ABOVE FINISHED GRADE. SH -SHEET IN COMMERCIAL STANDARD CS77-28 AS PROMULGATED NY THE U.S. DEPARTMENT OF CW - DOMESTIC COLD WATER ST - STORM APPLICABLE STANDARDS: CONDENSATE DRAIN PIPING: COMMERCE, FIXTURE FITTINGS SHALL COMPLY WITH ANSI/ASTM A112.18AM - 1989. 19. PROVIDE CLEANOUTS IN ACCORDANCE WITH ALL STATE AND LOCAL CODES. INSTALL DN -DOWN V -VENT PLUMBING TRIM FOR WATER CLOSET BOWLS, TANKS AND URINALS SHALL COMPLY WITH CLEANOUT WITH COVER FLUSH TO FINISH SURFACE. DWG - DRAWING VTR - VENT THRU ROOF A. GENERAL: ALL EQUIPMENT, MATERIAL, ACCESSORIES, METHODS OF CONSTRUCTION AND A. GENERAL: UNLESS OTHERWISE SPECIFICALLY NOTED CONDENSATE DRAIN PIPING SHALL BE THE SAME A5 SANITARY WASTE AND VENT PIPING. ANSI/ASTM A112.19.5 - 1990. 20. COORDINATE EXACT FLOOR DRAIN LOCATIONS WITH ARCHITECTURAL DRAWINGS. SET FCO - FLOOR CLEANOUT WCO - WALL CLEANOUT REINFORCEMENT, FINISH QUALITY, WORKMANSHIP AND INSTALLATION SHALL BE WITHIN CLEANOUTS AND CLEANOUT ACCESS COVERS: FLOOR DRAINS BELOW FINISHED FLOOR TO ALLOW FOR FLOOR SLOPING TO THE DRAIN. CODE COMPLIANCE. EXECUTION: WTR -WATER - SHALL 8 S HE SAME NOMINAL PIPE SIZE AS THE PIPE TO A. SIZE: CLEAN OUTS 5 L EAT LEAST T ELECTRICAL EQUIPMENT PANELS TRANSFORMERS ETC. 21. COORDINATE PIPING WITH ALL Q ( ) 1. BARRIER FREE ACCESS: FIXTURES INDICATED TO PROVIDE BARRIER FREE ACCESS GENERAL: WHICH THEY ARE CONNECTED, TO A MAXIMUM OF 6 INCH DIAMETER, UNLESS OTHERWISE PRIOR TO ANY INSTALLATION. DO NOT ROUTE ANY PIPING OVER ANY ELECTRICAL SHALL BE DESIGNED, MANUFACTURED AND INSTALLED IN ACCORDANCE WITH ANSI 117.1- A. LOCATION OF VENTS: VENTS SHALL 8E OFFSET AS REQUIRED TO PENETRATE ROOFS AT INDICATED. PANELS UNDER ANY CIRCUMSTANCES. ANY PIPING RUN OVER PANELS SHALL BE 1986 AND THE "FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION" FROM THE LEAST 3 FEET FROM THE EDGES OF THE BUILDING, AND 15 FEET FROM ANY SUPPLY AIR 1. MATERIAL: CLEAN -OUTS SHALL COMPLY WITH ANSI A112,36.2M - 1993 AND SHALL BE RE-ROUTED AT NO ADDITIONAL COST. FLORIDA BOARD OF BUILDING CODES AND STANDARDS, DEPARTMENT OF COMMUNITY AFFAIRS, OCTOBER 1997 REVISION WITH AMENDMENTS. INTAKE OR OPERABLE WINDOW OR DOOR. WATER- AND GAS -TIGHT CAST IRON CONSTRUCTION WITH ADJUSTABLE HOUSING TO 1. SLOPE: UNLESS OTHERWISE INDICATED, HORIZONTAL SANITARY AND STORM PIPING 2 1/2 ACCOMMODATE FINISHED FLOOR OR GRADE ELEVATION. CLEAN -OUTS IN WATERPROOFED 22. ALL WALL MOUNTED LAVATORIES SHALL BE ATTACHED TO FLOOR MOUNTED CARRIER DESIGNED TO WITHSTAND A VERTICAL LOAD OF 250 FOUNDS ON THE FRONT OF THE C. ASS[: FIXTURES AND DEVICES SHALL COMPLY WITH THE STANDARDS OF THE AMERICAN INCHES AND SMALLER SHALL NE SLOPED AT A MINIMUM OF 1/4 INCH PER LINEAR FOOT; FLOORS SHALL HAVE A FLASHING FLANGE AND CLAMP DEVICE. CLEAN -OUTS SHALL HAVE A COUNTERSUNK INTERNAL BRONZE PLUG AND SCORIATED NICKEL -BRONZE FIXTURE, SOCIETY OF SANITARY ENGINEERS, WHERE REQUIRED. PIPING 3 INCHES AND LARGER SHALL BE SLOPED A MINIMUM OF 1/8 INCH PER FOOT. REMOVABLE COVER; WALL CLEAN -OUTS SHALL HAVE POLISHED STAINLESS STEEL COVER D. ADA: FIXTURES, DEVICES AND INSTALLATION CLEARANCES AND HEIGHTS SHALL COMPLY SPECIFICALLY MANUFACTURED FOR THE WALL FINISH AT EACH LOCATION. FLOOR SPECIFICALLY 23, PROVIDE SANITARY WASTE, VENT,, DOMESTIC WATER, ETC. ROUGH -IN AND MAKE FINAL CONNECTIONS (TO INCLUDE PROVIDING ALL NECESSARY RELATED STOPS, VALVES, TRAPS, WITH THE REQUIREMENTS OF THE AMERICANS WITH DISABILITIES ACT ADA). C. VENT PIPING: HORIZONTAL VENT BRANCHES SHALL RE KEPT ABOVE THE HIGHEST FIXTURE SERVED BY THE VENT BRANCH IN ORDER TO PREVENT THE VENT FROM BEING -OUTS FOR FLOORS WITH FINISH COVERINGS SHALL HAVE THE TOP RECESSED FOR TILE OR CARPET, WITH A CLEAN -OUT MARKER, MANUFACTURED FOR THE FINISHED ETC. AND MAKE READY FOR USE) TO ALL EQUIPMENT, WHETHER FURNISHED BY THIS USED AS A WASTE LINE. HORIZONTAL VENT BRANCHES SHALL BE SLOPED UPWARD TO FLOOR MATERIAL. CONTRACTOR OR FURNISHED BY OTHERS. PREVENT ACCUMULATING WATER OR TRAPPING. PLUMBING PIPING SYSTEM: C. ACCESS COVER: ACCESS COVERS FOR CONCEALED WALL CLEAN -OUTS SHALL BE D. VENT CONNECTIONS: VENT PIPING CONNECTED TO A HORIZONTAL PIPE SHALL NE TAKEN NICKEL -BRONZE WITH SCORIATED HINGED COVER OR ROUND STAINLESS STEEL COVER GENERAL: FROM THE CENTERLINE OF THE PIPE. VENT PIPING SHALL RISE AT AN ANGLE NOT WITH COUNTERSUNK MACHINE THREADED CENTER SCREW, UNLESS OTHERWISE INDICATED. A. GENERAL PROVIDE DOMESTIC WATER PIPING, DRAINAGE WASTE AND VENT PIPING, AND EXCEEDING 45 DEGREES FROM VERTICAL, TO A POINT AT LEAST 6 INCHES ABOVE THE OTHER PLUMBING PIPING AND APPURTENANCES AS INDICATED. FLOOD RIM OF THE HIGHEST ATTACHED FIXTURE. ACCEPTABLE FIXTURE MANUFACTURERS: PLUMBING DRAWING INDEX PRODUCTS: E. VENT FLASHING: REFER TO ARCHITECTURAL DETAILS AND SPECIFICATIONS FOR PROPER A. NOTE: REFER TO THE CONTRACT DOCUMENTS FOR THE "BASIS OF DESIGN", FOR SHEET DESCRIPTION ISSUED FLASHING REQUIREMENTS OF VENT PIPING THROUGH THE ROOF. PLUMBING FIXTURES AND ACCESSORIES; SUMS11TUTIONS SHALL 8E REVIEWED THROUGH A. APPLICATION: THE PLUMBING PIPING SYSTEM SHALL ONLY BE OF THE MATERIALS THE NORMAL PROCESS. INDICATED. FDA PLUMBING - SPECIFICATIONS, LEGENDS, NOTES + DRAWING INDEX YES THERMAL INSULATION: 1. PLUMBING FIXTURES: KOHLER. SPECIFICATIONS. INSULATION SHALL COMPLY WITH ASTM E-84 REQUIREMENTS WITH A P1.0 PLUMBING - FLOOR PLAN, ISOMETRIC DIAGRAMS & DETAILS. YES FLAME SPREAD RATING NOT EXCEEDING 25 AND WITH A SMOKE DEVELOPED/FUEL A. GENERAL: ALL INSULATION, JACKETS AND ADHESIVES USED SHALL COMPLY WITH THE C. FAUCETS: KOHLER. IOU PLUMBING -ROOF PLAN YES CONTRIBUTED RATING NOT EXCEEDING 50. REQUIREMENTS OF ASTM E-84 WITH A MAXIMUM FLAME SPREAD RATING OF 25 AND A D. SUPPLIES: MCGUIRE, ENGINEERED BRASS COMPANY, KEENEY, AND TURN. B. VALVES: ALL VALVES USED IN THE PLUMBING PIPING SHALL ME 125 PSI SWP, 200 PSI MAXIMUM SMOKE DEVELOPED/FUEL CONTRIBUTED RATING OF 50. E. P-TRAPS: MCGUIRE, ENGINEERED BRASS COMPANY, KEENEY, AND ZURN. WOG INSULATION FOR CONCEALED PIPING SHALL BE PREFORMED PIPE INSULATION AS F. DRAINS: J.R. SMITH, JOSAM, WADE AND ZURN. FOLLOWS: C. DIELECTRIC CONNECTIONS: PROVIDE APPROVED CONNECTIONS FOR DISSIMILAR G. CLEANOUTS: J.R. SMITH, JOSAM, WADE AND ZURN. MATERIALS. 1. THICKNESS: THE INSULATION THICKNESS IN INCHES SHALL BE IN ACCORDANCE WITH THE FOLLOWING TABLE: H. CONCEALED CARRIERS: J.R. SMITH, JOSAM, WADE AND ZURN. VALVES: TABLE - PIPE INSULATION THICKNESS FIYl11RF INCII lTlflAl• A. 4 INCH AND SMALLER: VALVES 4 INCH AND SMALLER SHALL BE FULL PORT VALVES WITH BRONZE OR BRASS BODY AND BRONZE TRIM, THREADED OR SOLDERED PIPE SIZESINCHES UP TO 1" 11/4' TO '21/2 "O 4 T A. GENERAL: OBTAIN MOUNTING TEMPLATES AND DIMENSIONS PRIOR TO ROUGHING -IN PLUMBING CONNECTIONS. MOUNT FIXTURE ON CARRIER WHICH IS BOLTED TO THE CONDENSATE DRAIN 112" 1/2"112" CONNECTIONS.. BUILDING STRUCTURE WITH THROUGH -BOLTS OR PRE-SET INSERTS. FLOOR -MOUNTED � (OR MANUFACTURER'S MINIMUM THICKNESS LASED ON THE PIPE SIZE.) FIXTURES SHALL HAVE SUPPORTS, BLOCKING OR ANON -SHRINK GROUT SETTING BED TO 1. BUTTERFLY VALVES SHALL NOT BE PERMITTED ON DOMESTIC WATER SYSTEMS. C. EXPOSED; FOR PIPING, OTHER THAN DOMESTIC COLD WATER, EXPOSED TO THE OUTDOOR AIR DR IN PREVENT MOVEMENT OR FLEXING, FLOOR -MOUNTED, WALL MOUNTED AND COUNTERTOP AN UNCONDITIONED CRAWL SPACE OR CELLAR AREA, INCREASE INSULATION THICKNESS BY 1/2 INCH. FIXTURES SHALL BE SEALED WATERTIGHT WITH A FLEXIBLE, NON -PERMEABLE CAULK OR DOMESTIC WATER PIPE: MASTIC. PROVIDE STAINLESS STEEL ESCUTCHEONS AT EACH WATER SUPPLY AND WASTE PIPING PENETRATION OF A WALL OR CABINET; CAULK EACH ESCUTCHEON. ADJUST ALL A. ABOVE GROUND: INSULATION: FIXTURES LEVEL AND PLUMB AT PROPER MOUNTING HEIGHT. 1. PIPING 4 INCHES AND SMALLER SHALL BE COPPER TUBE, TYPE L OR K, HARD DRAWN. A. TRAPS: INSULATE ALL TRAPS RECEIVING CONDENSATE WITH A MINIMUM 8. ROUGH -IN: DURING ROUGH -IN, WATER AND WASTE 5TU8-OUTS SHALL BE LOCATED TO 1/2" ELASTOMERIC INSULATION. INSULATION SHALL EXTEND 10 FEET PREVENT CAPS BETWEEN THE FIXTURE AND THE FINISHED WALL, AND TO ALLOW EXPOSED 2. EXPOSED PIPING IN FINISHED AREAS SHALL BE CHROME -PLATED BRASS PIPE OR HORIZONTALLY FROM THE P-TRAP OF THE DRAIN. PIPE TO RE INSTALLED STRAIGHT AND PLUMB FROM THE STUB -OUT TO THE FIXTURE. CHROME -PLATED BRASS TUBING. CONTINUOUSLY COVER WALL OPENINGS AND OPEN PIPE ENDS TO PREVENT SANITARY WASTE AND VENT PIPING: HANGERS: CONSTRUCTION DEBRIS FROM ENTERING. 1. HANGERS FOR ALL OTHER TYPES OF PIPING SHALL RE GALVANIZED STEEL CLEVIS TYPE OR SPLIT RING. C. SPECIAL FIXTURES: FOR EQUIPMENT TO RE CONNECTED LATER OR UNDER A SEPARATE. A. ABOVE GROUND: PIPE HANGERS SHALL 8E CAPABLE OF VERTICAL ADJUSTMENT AFTER ERECTION OF THE PIPING, CONTRACT, PROVIDE VALVED AND CAPPED WATER LINES; PROVIDE FLOOR DRAINS, OPEN 1. CAST IRON SOIL PIPE, SERVICE WEIGHT, WITH BELL AND SPIGOT JOINTS. HANGER RODS SHALL RE GALVANIZED. SITE DRAINS, OR CAPPED WATER CONNEC1ONS AS INDICATED OR REQUIRED. 2. CAST IRON SOIL PIPE, SERVICE WEIGHT, WITH NO -HUB COUPLINGS. FOR ABOVE 2. VERTICAL PIPING RISER CLAMP SUPPORTS SHALL ME CONSTRUCTED OF STEEL WITH ROUNDED EARS D. FIXTURE CONNECTIONS: PROVIDE VALVE COCKS OR STOPS IN PRESSURE PIPING TO GROUND INSTALLATION ONLY, AND TWO OR FOUR HOLES FOR CLAMPING BOLTS. RISER CLAMPS SHALL BE GALVANIZED STEEL, FIXTURES IN LINES 1/2 INCH OR SMALLER; PROVIDE GATE VALVES IN PIPING 3/4 INCH EXCEPT THAT RISER CLAMPS FOR COPPER AND BRASS PIPING RISER CLAMPS SHALL HAVE PVC AND LARGER. PROVIDE A WATER SEAL TRAP WITH EACH FIXTURE INCLUDING FLOOR 3. COPPER: COATING FINISH OR COPPER. DRAINS AND FLOOR SINKS) WHETHER INDICATED OR NOT. DRAINS SHALL BE SIZED AS A. TYPE DWV WITH SOLDERED JOINTS, INDICATED OR REQUIRED BUT IN NO CASE LESS THAN 1-1/2 INCH PIPE SIZE. MANUFACTURER: 1. TYPE M WITH SOLDERED JOINTS FOR VENT PIPING ONLY. 1. GRINNELL E. FIXTURE MOUNTING CRITERIA: PLUMBING FIXTURES SHALL COMPLY WITH THE FOLLOWING 4. BRASS PIPE OR TUBE, CHROME PLATED, WHERE EXPOSED IN FINISHED AREAS. 2. RHO MANUFACTURING INC, MOUNTING CRITERIA UNLESS SPECIFICALLY DIMENSIONED OTHERWISE ON THE DRAWINGS: 3. PIPE SHIELDS INC. M. BELOW GROUND: STANDARD ACCESS FIXTURES: 1. PVC: PVC PIPING SHALL 8E PERMITTED BELOW GRADE ONLY. A. TYPE DWV, SCHEDULE 40, ASTM D-1784 AND D-255. A. WALL HUNG LAVATORY - 31 INCHES FROM FINISH FLOOR ELEVATION TO TOP OF RIM. NARRIER-FREE FIXTURES: A. WATER CLOSET - 19 INCHES FROM FINISH FLOOR ELEVATION TO RIM OF FIXTURE, 1. LAVATORY - MAXIMUM 34 INCHES FROM FINISH FLOOR ELEVATION TO TOP OF RIM. I • ••! • r G Y V r u f • TID I� ••• • •VJ• r • • • i i • • • V Y G• '. • r • • •r • • • • • • 40N MM M MINA, IL ! I jowl G V s a • . • V V u • cffnmcA71L1N Na AA • • ! • • • • • s r • r • • • • EMMANUEL 0 R CIHIIIIy AIA • ` • • uc NO. AR-0015315 • • ••!• f •r••i • •.+ . ••u• o I CONSULTANTS- C) rt ©. W C Lu rn Ln Za Oo U-C -s 0 ZV W 04 u,� Z � Z� M LI.J Z nc 4W :z t .... o Zz Lr, z W X Lu �- Q z Ln O U W m C(,f� M M a 0 U ad z..� LUL V) P :% CC Z �- 0 <[Cie -- J ~ Ljj J F_ U <0 LL. V; U LLJ -4:1� Cie <7 r H Z to CLLJ "� 5 J 4�ttttttl:�t►,i:pt. PROJECT NO: ???? DRAWN BY WAW REVIEWED NY: DA APPROVED NY DA DATE 08/09/2004 REVISION DATES- 9-NET NUMEt P 0.1 OF 2