06-1789-012FIRE -_PROTECTION SPECIFICATIONS 1.01 SUMMARY A. GENERAL: PROVIDE THE FIRE PROTECTION SYSTEMS INDICATED ON THE DRAWINGS AND WITHIN THIS 1.02 APPLICABLE STANDARDS A. GENERAL: ALL EQUIPMENT, MATERIAL, ACCESSORIES, METHODS OF CONSTRUCTION AND REINFORCEMENT, FINISH QUALITY, WORKMANSHIP AND INSTALLATION SHALL BE IN COMPLIANCE WITH THE PARAGRAPH ENTITLED "CODE COMPLIANCE" IN SECTION 15010. B. REVISED EDITIONS OF THE NFPA NATIONAL FIRE CODES (NFPA) AS INDICATED IN SECTION 15010. C. EDITIONS OF THE NFPA NATIONAL FIRE CODES (NFPA), OR THE LATEST REVISIONS OF THESE CODES AS ADOPTED BY THE AUTHORITY HAVING LAWFUL JURISDICTION, AS FOLLOWS: 1. NFPA - FIRE SPRINKLER SYSTEM: THE FIRE SPRINKLER PROTECTION SYSTEMS INSTALLATION, FLUSHING AND TESTING SHALL COMPLY WITH THE REQUIREMENTS OF NFPA 13, AND 24. D. PIPE THREAD PATTERN: ALL THREADS SHALL BE IN ACCORDANCE WITH LOCAL FIRE DEPARTMENT SPECIFICATIONS AND NFPA 1963. E. UL/FM APPROVAL: ALL EQUIPMENT, PIPING, FITTINGS, VALVES, COUPLINGS, HANGERS AND DEVICES SHALL BE APPROVED BY UNDERWRITERS' LABORATORY (UL) AND FACTORY MUTUAL (FM) FOR USE IN FIRE PROTECTION SERVICE. F. LICENSURE: THE FIRE PROTECTION SYSTEMS SHALL BE INSTALLED BY A STATE OF FLORIDA LICENSED FIRE PROTECTION CONTRACTOR. PART 2 - PRODUCTS 2.01 MANUFACTURER A. SINGLE MANUFACTURER: ALL ITEMS OF A SIMILAR TYPE SHALL BE BY THE SAME MANUFACTURER. 2.02 SPRINKLER HEADS A. PROVIDE THE FOLLOWING SPRINKLER HEADS OF PROPER TYPES, RATINGS, AND SPACINGS FOR THE AREAS INVOLVED. PROVIDE APPROPRIATE FINISHES COMPATIBLE WITH SPACE FINISHES BEING SERVED. ACCEPTABLE MANUFACTURERS: VIKING, GRINNELL, AUTOMATIC SPRINKLER, CENTRAL, STAR, AND RELIABLE. B. SPRINKLER CAGE GUARD: PROVIDE SPRINKLER HEAD OPEN -WIRE CAGE GUARD TO PROTECT THE SPRINKLER HEADS. CAGE WIRE SHALL BE CADMIUM -PLATED STEEL. INSTALL CAGE GUARD IN MECHANICAL ROOMS AND ELECTRICAL ROOMS. 2.03 PIPE AND FITTINGS A. ABOVE GROUND PIPE AND FITTINGS: 1. PIPING SHALL BE SCHEDULE 40 BLACK STEEL PIPE CONFORMING TO ASTM A135 OR ASTM A53, AND SCHEDULE 10, ASTM A135. 2, THREADABLE THINWALL BLACK STEEL PIPE CONFORMING TO ASTM A135, OR ASTM 795, WITH A CORROSION RESISTANCE RATING (CRR) OF 1.0 OR GREATER AS MANUFACTURED BY AMERICAN TUBE COMPANY, DYNA-THREAD-40 OR EQUIVALENT 3. FITTINGS: (A) CAST IRON THREADED FITTINGS, ANSI B16.4 CLASS 125. (B) CAST IRON FLANGED FITTINGS, ANSI B16.1 CLASS 125. (C) MECHANICAL JOINT, GROOVED COUPLINGS, AS MANUFACTURED BY VICTAULIC, ANVIL, OR CENTRAL. ALL GROOVE COUPLINGS AND FITTINGS SHALL BE FURNISHED BY A SINGLE MANUFACTURER. (D) SYSTEM PRESSURES EXCEEDING 175 PSI SHALL HAVE CAST IRON THREADED FITTINGS, GROOVE COUPLINGS AND FLANGED FITTINGS, CLASS 250 RATED FOR A MINIMUM 400 PSI. B. HANGERS, SUPPORTS, AND SLEEVES: 1. SUPPORT PIPING WITH UL AND FM APPROVED HANGERS. HANGERS AND RODS SHALL BE GALVANIZED. 2. ACCEPTABLE MANUFACTURERS: GRINNELL, B-LINE, HILTI, FEE k MASON, MICHIGAN AND PHD. 3. ADJUSTABLE CLEVIS HANGER: GRINNELL FIG. 260. 4. ADJUSTABLE SWIVEL LOOP HANGER: GRINNELL FIG. 69. 5. BEAM CLAMP: GRINNELL FIG. 92 AND GRINNELL FIG. 218. 6, CONCRETE FASTENERS: GRINNELL STEEL SHELL AND EXPANDER PLUG. 7. CONCRETE INSERT: GRINNELL FIG. 152. 8. RISER CLAMP: GRINNELL FIG. 261. 9, POWDER -DRIVEN INSERTS SHALL NOT BE ACCEPTED. 10. THREADED RODS SHALL BE GALVANIZED COATED. ALL HANGERS SHALL BE GALVANIZED COATED. C. FIRE STOPPING 1. ALL PIPES PASSING THROUGH RATED FLOORS OR WALLS SHALL BE SLEEVED AND FIRESTOPPED TO AN EQUIVALENT RATING OF THE FLOOR OR WALL ASSEMBLY. FIRESTOP MATERIALS SHALL MEET ASTM E814 REQUIREMENTS 2. ACCEPTABLE MANUFACTURERS: HILTI AND 3M. PART 3 - EXECUTION 3.01 INSTALLATION: A. HANGERS: ALL HANGER SPACING SHALL COMPLY WITH THE REQUIREMENTS OF NFPA-13 B. SPRINKLER HEAD LOCATION: INSTALL SPRINKLER HEADS IN THE CENTER OF THE CEILING TILES FOR SUSPENDED CEILING APPLICATIONS. C. SPRINKLER HEAD LOCATION: SPRINKLER HEADS SHALL BE INSTALLED NO CLOSER THAN 4 INCHES TO ANY CEILING GRID OR WALL. D. PROHIBITED: DO NOT PAINT THE COVERS OF CONCEALED SPRINKLERS. 3.02 EQUIPMENT INSTRUCTION PLATES A. GENERAL: PROVIDE ENGRAVED INSTRUCTION PLATES DETAILING EMERGENCY PROCEDURES AT EACH SYSTEM CONTROL PANEL AND AT EACH HAZARD AREA MANUAL DISCHARGE STATION LOCATIONS. PERMANENT NAMEPLATES SHALL BE USED IN THE CONTROL PANEL TO IDENTIFY CONTROL LOGIC UNITS, CONTACTORS AND MAJOR CIRCUITS. 3.03 HYDROSTATIC TESTS A. GENERAL: ABOVE GROUND AND BELOW GROUND PIPING SYSTEMS SHALL BE HYDROSTATICALLY TESTED AT NOT LESS THAN 200 PSI PRESSURE, OR AT 50 PSI IN EXCESS OF THE MAXIMUM PRESSURE, WHICHEVER IS GREATER, FOR A PERIOD OF 2 HOURS. THE TEST PRESSURE SHALL BE READ FROM A GAUGE LOCATED AT THE LOW ELEVATION POINT OF THE INDIVIDUAL SYSTEM OR PORTION OF THE SYSTEM BEING TESTED. THE UNDERGROUND PIPING SHALL NOT HAVE LEAKAGE EXCEEDING THE AMOUNTS SPECIFIED IN NFPA 24. LEAKAGE QUANTITIES SHALL BE DETERMINED BY PUMPING AT THE SPECIFIED TEST PRESSURE FROM A CALIBRATED CONTAINER. REPAIR LEAKING JOINTS AND RETEST AS NECESSARY UNTIL ALL SYSTEMS HAVE BEEN TESTED. TEST THE PIPING BETWEEN THE CHECK VALVE IN THE FIRE DEPARTMENT INLET PIPE AND THE OUTSIDE CONNECTION THE SAME AS THE BALANCE OF THE SYSTEM. 3.04 SYSTEM INSPECTION AND CHECKOUT A. GENERAL: AFTER THE INSTALLATION IS COMPLETE, THE SYSTEM SHALL BE INSPECTED BY FACTORY TRAINED PERSONNEL IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDED PROCEDURES. B. SYSTEM OPERATION: OPERATE SYSTEMS AS REQUIRED TO DEMONSTRATE THAT THE SYSTEMS ARE OPERATING IN ACCORDANCE WITH THE DESIGN, INCLUDING LINE PRESSURE TESTING. SUPPLY INSTRUMENTS REQUIRED TO READ DATA. ADJUST SYSTEMS TO OPERATE AT THE REQUIRED PERFORMANCE LEVELS, ADVISE OWNER 7 DAYS PRIOR TO TESTING. TABULATE DATA AND SUBMIT ON 8-1/2 X 11-INCH SHEETS WITH TIME, NAME OF TESTER AND THE LOCAL AUTHORITY HAVING JURISDICTION AND WITNESSING THE TEST, WITH ONE COPY FOR EACH TECHNICAL INFORMATION BROCHURE. KEYED NOTESi 0 SPRINLKER HEAD TO BE REMOVED AND REPLACED IN A NEW LOCATION AS INDICARED. © NEW PENDANT SPRINKLER HEAD REPLACING UPRIGHT HEADS TYPICAL FOR ALL SPRINKLER HEADS IN THIS UNIT. C3> NFW PENDANT SPRINKI FR HFAD RFPI ACING UPRIGHT HFAD. rNr-r. Ii i ALT. ROOM I� 17 �J / SHOW ROOM L 4 N FIRE PROTECTION - SCALE: 1/4"= I -U„ i • N Y i • 4•••i • • • w w Y y Y • ••i i•• • • i rYY• u Y ! • • • • • i • ! • i 4. • W • • • • • • • • • • r• Y • •• Y r w w - • �iir • i • • I,; ••••r • r•••• • !•!!• • *Dec;W • i FITTING FITTING �� FITTING R00117C ROM_ROC) 1, STO R. it AM �•I PANCL i UNIT I rureI ,� CA HIER/OFFICE; SPACE'. Q (TYP.) SHOh V R09M i 41% S w _+ �I -- - r Eli ,.j QrI i`.F:t,'F�CJOt.:L ED BY ATE FLOOR PLAN FIRE PROTECTION NOTES 1) SEE SUBMITTAL DATA FOR MANUFACTURERS DETAIL ON ITEMS OF EQUIPMENT BEING USED. 2) PIPE HANGERS AND INSTALLATION METHODS SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF LATEST EDITION OF NFPA 13. 3) PIPING SPECIFICATIONS - ALL PIPE TO BE IN ACCORDANCE WITH THE LATEST EDITION OF NFPA 13 AND DESIGNED TO WITHSTAND A WORKING PRESSURE OF 175 P.S.I. COLD WATER. 4) WELDED PIPING TO BE IN ACCORDANCE WITH THE LATEST EDITION OF NFPA 13 AND THE REQUIREMENTS OF AWS D 10.9 LEVEL AR-3. 5) THE OWNER IS RESPONSIBLE FOR MAINTAINING THE PROPER OPERATING CONDITION OF SYSTEM(S) AND DEVICES. 6) ALL ELECTRICAL CONTROL AND/OR ALARM SYSTEM WIRING TO BE PROVIDED AND INSTALLED BY OTHERS. 7) SPRINKLERS SHALL BE CENTERED IN THE CEILING TILE MODULES. 8) ALL AUTOMATIC SPRINKLER PIPING, INCLUDING THE UNDERGROUND FIRE SERVICE MAINS SHALL BE INSTALLED BY A CERTIFIED CONTRACTOR AS PER FLORIDA ADMINISTRATIVE CODE RULE 4A-46 AND STATE STATUTE 489.105 (N) . 9) FIRE PROTECTION SYSTEM TO COMPLY WITH NFPA 13,24, 101 AND ALL APPLICABLE LOCAL AND STATE CODES. 40 1" 90' ELL 1" 90' ELL TOP BEAM CLAMP 4 CONCRETE FASTENER ALL THREAD ROD ALL THREAD ROD BRANCH LINE PIPE HANGER RING lxl/z REDUCER 1" DROP PIPE HANGER RING CEILING j SPRINKLER HEAD CONCRETE INSERT DETAIL (U.L. LISTED OR F.M. APPROVED) N.T.S. RETURN BEND DETAIL T 0 P BEAM CLAMP DETAIL NEW INSTALLATION N.T.S. (U.L. LISTED OR F.M. APPROVED) N.T.S. FIRE PROTECTION DRAWING INDEX DRAW I DESCRIRTION FP1.0 FIRE PROTECTION - FLOOR PLAN, LEGEND, DRAWING INDEX AND DETAILS. FIRE SPRINKLER HEAD LEGEND SYMNOL ORF TEMP RESPONSE K-FAC FINISH MODEL STYLE PLATE MFG. 1/2" 155' QUICK 5.60 CHROME F1FR NEW RECESSED CHROME RELIABLE O 1/2" 155' QUICK 5.60 BRASS F1FR NEW UPRIGHT NONE RELIABLE f - - - _ - - EXISTING TO BE REMOVED - - p - - - _ - - EXISTING TO REMAIN - - FIRE PROTECTION LEGEND ,z CHECK VALVE NEW SPRINKLER BRANCH PIPING - - - EXISTING SPRINKLER PIPING TO REMAIN - - - EXISTING SPRINKLER PIPING TO BE REMOVED r-F.C.I FLUSHING CONNECTION 40 N ~ ME MANS, IL" I& 381"mm In N am`` I,,R..,,C401`'0NI NIX AAA CMMM E.UEL O Vvf7E� AIA uc. NO.: AR-0015315 OONSULTANTS- Z Q �'r 1 LA_ LLJ 0 I-- � � 00 t� C36-- s Lu Z o� v U W pC � Li.i,.. E VV Zz LLJ g� L_u L JLJ w p r. Lu } Z ::) Z `� m 01 rf, 0x O 0 w �V ad 4 0 --�116 ❑- I I I w Lu J H Cie 0 O 0 ..j L L.. '.4 y� r 0. PROJECT NO: ?m DRAWN BY WAW REVIEWED WY. BA APPROVED BY: DA BATE 08/09/2006 REVISION DATES: MET NUMRt FP1.0 Or 1