05-1298-010JOHN R. MEDINA & ASSOC.
A R C HIT E C T S
LEGEND
NEW 12"CMU WALL
NEW 8" CMU WALL
III
NEW 4" METAL STUD
PARTITION WALL '
NEW METAL STUD PARTITION WALL.
REFER TO FLOOR PLAN FOR SIZE
O
NEW COLUMN. REFER TO
ELEVATIONS AND DETAILS FOR SIZE
0
NEW COLUMN. REFER TO
ELEVATIONS AND DETAILS FOR SIZE
GENERAL NOTES:
ARCHITECTURAL DRAWINGS REFLECT
ELEVATION @ FINISH FLOOR. G.C. TO REFER
TO STRUCTURAL DRAWINGS FOR SLAB FINISH
LEVEL AND TO COORDINATE AS REQUIRED.
G.C. TO CONTACT ARCHITECT IN CASE OF
DISCREPANCES.
NOTE:
EMERGENCY WINDOW -SILL LOCATED 4N'
A.F.F MAX.
REFER TO SHT A 8.1 FOR EMERGENCY
WINDOWS.
GARAGE NOTES:
1407.6 (A.) SIGN REQUIRED: PROVIDE A
PERMANENT SIGN IN A READILY VISIBLE
LOCATION WITHIN THE GARAGE ON THE
INSIDE FACE OF ANY ONE DOOR TO THE
OUTSIDE OF THE ENCLOSURE READING:
DANGER! DO NOT OPERATE ENGINES
WITH DOOR CLOSED. CARBON
MONOXIDE EMISSION IS LETHAL.
GARAGE CEILING TO BE TWO -LAYERS OF
5/8" TYPE "X" GYPSUM LATH ON 1 "X 3"
FURRING (OR 7/8" HIGH HATS) @ 16" O.C.
MAXIMUM, WITH 6D CEMENT COATED
NAILS 6" O.C. WITH BUTT & SIDE JOINTS
STAGGERED, PAPER TAPE EMBEDDED
OVER JOINTS AND EXPOSED NAIL HEADS
COVER WITH COMPOUND. (14 HOUR FIRE
RATED CEILING ASSEMBLY).
GARAGE WALLS TO BE li FIRE RATED
WALL.
PROVIDE (2) SCREENED VENT BLOCKS OF
60 SQ.IN. EACH TOTAL OF 120 SQ. IN.
PROVIDE 2" X 6" P.T. WOOD JAMB @ EA.
SIDE OF GARAGE DOORS W/ 1 /2" X 6'
LONG ANCHOR BOLTS @ 24' O.C. (BEGIN
6" FROM BOTTOM & TOP).
PROVIDE ADEQUATE STEEL FRAME
SUPPORT FOR ELECTRIC GARAGE DOOR
B9ff&WIATFACTURER.
- ALL EXTERIOR DOOR AND WINDOW
OPENINGS SIZE & LOCATION TO BE
COORDINATED WITH WINDOW
SCHEDULE, STRUCTURAL DRAWINGS &
MANUFACTURER'S REQUIREMENTS.
-ARCHITECT TO BE NOTIFIED IN CASE OF
ANY DISCREPANCIES.
TERMITE PROTECTION:
SHALL BE PROVIDED BY REGISTERED
TERMITICIDES, INCLUDING SOIL
APPLIED PESTICIDES, BAITING
SYSTEMS, AND PESTICIDES APPLIED
TO WOOD, OR OTHER APPROVED
METHODS OF TERMITE PROTECTION
LABELED FOR USE AS A PREVENTATIVE
TREATMENT TO NEW CONSTRUCTION.
SEE SECTION 202, REGISTERED
TERMITICIDE. UPON COMPLETION OF
THE APPLICATION OF THE
COMPLIANCE SHALL BE ISSUED TO
THE BUILDING DEPARTMENT BY THE
LICENSED PEST CONTROL COMPANY
THAT CONTAINS THE FOLLOWING
STATEMENT: 'THE BUILDING HAS
RECEIVED A COMPLETE TREATMENT
FOR THE PREVENTION OF
SUBTERRANEAN TERMITES.
TREATMENT IS IN ACCORDANCE
WITH RULES AND LAWS ESTABLISHED
BY THE FLORIDA DEPARTMENT OF
AGRICULTURE AND CONSUMER
SERVICES:'
FIREPLACE:
FIREPLACE MANUFACTURER SHALL
SUBMIT SHOP DRAWINGS FOR FINAL
REVIEW & APPROVAL BY ARCHITECT
& BUILDING DEPT. FIRE PLACE SHALL
COMPLY W/ F.B.C. 2001 SECT. 2114.
I L`.JvN i Lri v
4901 S.W.75th Avenue
Miami, Florida 33155
T 305.740.0554
F 305.740.5355
jrmaincCa@bellsouth.net
REVISIONS DATE
REVISION # 1
03.30.06
N[�,
4- SO
U"
0
o
a)
0
-I-- Q
U
Q
^N
W
4-
U
0
N
(n
U
a)
F1
Drawings and Specifications as instrument of
service are and shall remain the property of
the Architect and shall remain the property
of the Architect whether the project for
which they were made is executed or not.
They are not to be used in any manner on
other projects or extensions to this project
except by agreement in writing and with the
appropriate compensation to the Architect.
Reproduction of drawings and
specifications without the written consent of
the Architect is prohibited.
FIRST FLOOR
BY
CAP
MR & MRS. PINO
RESIDENCE.
MR. & MRS. PINO
6864 SW 68 th ST.,
Miami, FL 33155
Contact: Mr. Henry Pino.
305.573.7140
SCALE: 3/16"=1'-0"
DATE: 05-07
DRAWN: CAP
�I
SCALE: 3/ 16"=1 1 0"