05-1298(2)-051JOHN R. MEDINA & ASSOC. A R C H I T E C T S 120Q40V PAN E L "A" 200 M.L.O. 1PH,3W SURFACE MTD BRANCH CIRCUITS LOCATION WIRE AND CONDUIT TOTAL BREAKER TRIP CKT NO. CKT NO. BREAKER TRIP TOTAL WIRE AND CONDUIT LOCATION V.A V.A ENTRY #12-1/2"C * 1P-20 1 2 1P-20 16W 412-1/2"C DINING REG. FOYER 3 4 16W APPLIANCES LIVING ROOM 5 6 1600 APPLIANCES LIVING ROOM 7 8 16W APPLIANCES HALLWAY 9 10 1000 DISHWASHER VIDEO ROOM 11 12 800 G. DISPOSAL 13 14 1500 MICROWAVE 15 16 2P 3000 248,1#10 OVEN 11 17 18 40 3000 1 #10 GRD-3/4"C D.R. / BREEZEWAY 19 20 1 P-20 1000 #12-1/2"C TRASH COMPACTOR PLAY ROOM 1 121 22 1 P-20 1000 SPARE PLAY ROOM 23 24 2P 5500 2 #4-1"C AHU No. 1 OFFICE 25 26 60 56W (10 KW) 27 28 2P (3000) 2 #6-3/4"C C.U. No. 1 29 30 60 (3000) 31 32 1P-20 1000 #12-1/2"C DISHWASHER 33 34 900 #12-1/2"C SPARE BATH RECEPT. 35 36 11 900 SPARE SPACE 37 38 SPACE 39 40 11 41 42 11 * 2400 S.F. 7200 SUBTOTAL 7200 TOTAL = 38,300 31,100 SUBTOTAL (a) AFCI CB A/C @ 100%= 4200 HEAT @ 65%=7150 DEMAND LOAD = 27.3 KW FIRST 10 KW @ 100 % 17.3KW@40% A/C 10.0 KW 6.92 KW 7.15 KW 24.07 KW (100A) 120/240V PANEL "CA' 100A M.C.B. 1 PH, 3W (CABANA) SURFACE M.T.D. BRANCH CIRCUITS LOCATION WIRE AND CONDUIT TOTAL BREAKER TRIP CKT NO. CKT NO. BREAKER TRIP TOTAL WIRE AND CONDUIT LOCATION VA VA STORAGE #12-1/2"C 900 1P-20 1 2 2P 1500 #10-1/2"C POOL BATH / PORCH 900 3 4 25 1500 PUMP BATH RECEPT 900 5 6 2P 16W #10-1/2"C SPA WATER HEATER 3410 -1/2"C 2100 2P 7 8 25 15W PUMP 2100 30 9 10 1 P-20 600 #12-1 /2"C POOL / SPA LTG. SPARE 900 1P-20 11 12 1P-20 600 #12-1/2"C RECEPTACLE SPACE 13 14 SPACE 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 SUBTOTAL 7,800 TOTAL = 15,000 7,200 SUBTOTAL (b) ON TIMER DEMAND LOAD: 15.0 (c) GFI FIRST 10 KW @ 100% = 10.0 5.0 KW @ 40% = 2.0 12.00 KW (50A) 1201240V PANEL "M 11 400A MLO 1 PH, 3W W.PROOF) SURFACE MTD CKT. NO. DESCRIPTION CB TRIP LOAD WIRE CONDUIT REMARKS 1 PNL "A" 2P-200 38.300 3#310, 1 #6 GRD-1 "C MAIN #1 2 PNL "B" 2P-200 42,200 3#310. 1 #6 GRD-1 "C MAIN #2 3 PNL "C" 2P-100 15.900 3#3, 1#6-12"C MAIN /3 4 PNL "CA" 2P-100 15.000 3#3' 116 GRD-12 C MAIN #4 5 PNL "EM" 2P-125 29,900 3,#1, 116 GRD-2"C MAIN #5 TOTAL: 141,300 FIRST 1OKW 0 1009 = 10.0 98.3 KW 0 40% = 39.32 A/C = 21.65 TOTAL = 70.97 KW (296A) DEMAND Als PNL "A" 27.3 7.15 PNL "B" 31.2 7.15 PNL "C" 15.9 -- PNL "CA" 15.0 -- PNL "EM" 18.9 7.15 108.3 21.45 (b) (b) (c) (a) (a) (a) 1201240V PANEL "B" 200 MI.L.O. 1 PH,3W SURFACE MTD BRANCH CIRCUITS LOCATION WIRE AND CONDUIT TOTAL BREAKER TRIP CKT NO. CKT NO. BREAKER TRIP TOTAL WIRE AND CONDUIT LOCATION V.A V.A WASHER #12-1/2"C 1500 1P-20 1 2 2P 5600 244-1"C AHU No.2 G. OPENER 600 3 4 60 66W (10 KW) G. OPENER 600 5 6 2P (2000) 2 #8-3/4"C CU NO.2 GARAGE 1000 7 8 60 (2000) GUEST ROOM * 9 10 2P 6000 3 #8-3/4"C W.H. No.1 GUEST ROOM * 11 12 40 6000 TERRACE * 13 14 2P 2500 3#10-1/2"C DRYER REFRIG. 1500 15 16 30 2500 W/GRD. BAR 1500 17 18 r 1P-20 * 412-1/2"C GREAT ROOM BAR 11r 19 20 Sk GREAT ROOM BAR * 21 22 * OUTSIDE ILTG. BAR * 23 24 * KITCHEN ILTG. MAIDS * 25 26 * KITCHEN ILTG. LAUNDRY ROOM 16W 27 28 900 MINI-AHU SPARE 11 900 29 30 2P 900 #10-1/2'C MINI SPACE 31 32 25 900 COND. 33 34 SPACE 35 36 SPACE 37 38 39 40 41 42 * 1100 S.F. 3300 SUBTOTAL 12,400 TOTAL = 42,200 29,800 SUBTOTAL (a) AFCI CB (b) ON TIMER (c) GFI A/C @ 100%= 4200 HEAT @ 65%=7150 DEMAND LOAD = 31.2 KW FIRST IOKW@100% 21.2 KW @40% A/C (7.15) 10.0 K V 8.48 KW. 7.15 KW 25.63 KW (107A) 120/24OV PANEL "EM' 125A M.L.O. 1 PH, 3W (EMERGENCY) BRANCH CIRCUITS LOCATION WIRE AND CONDUIT TOTAL BREAKER TRIP CKT NO. CKT NO. BREAKER TRIP TOTAL WIRE AND CONDUIT LOCATION VA VA REFRIGERATOR #12-1/2"C 1500 1P-20 1 2 2P 5500 2#4-1"C A.H.U.No. 3 FREEZER 1500 3 4 60 5500 (10 KW) MICROWAVE 1500 5 6 2P (3000) 2#6-3/4"C C.U. No.3 KITCHEN LTG. 900 7 8 60 (3000) FOYER / HALLWAY 900 9 10 1 P-20 900 412-1 /2"C GREAT RM. / MAIDS OFFICE / PLAY ROOM 900 11 12 900 2nd FL. LTG. COOK TOP 2#8, 1#10 3000 2P 13 14 900 M. BEDROOM LTD. 1#10, GRD-3/4"C 3000 40 15 16 900 M. BEDROOM LTG. SPARE 1 P-20 17 18 900 OFFICE SPACE 19 20 600 M. BEDROOM REDEPT. 21 22 600 M. BEDROOM REDEPT. 23 24 SPARE 25 26 27 28 SPARE 29 30 31 32 33 34 35 36 37 38 39 40 41 42 SUBTOTAL 13,200 TOTAL = 29,900 16,700 SUBTOTAL (a) AFCI C/B (b) ON TIMER DEMAND LOAD: = 18.9 KW (c) GFI FIRST 10 KW @ 100% = 7.15 8.9 KW @ 40% = 10.0 A/C = 3.56 COMPLY WITH NEC 210.12(a all" OETECTO�-� LPlE SIDH i40V cr SWITCH SWITCH SWITCH L£O �iAeE coNoucTOR SMOKE DETECTOR COI ECTIGN DETAIL NT& NOTES. t-SI'ICKE DETECTOR SHALL. BE HAROUARED (10 VOLT TYPE) TO A NON-6UNTCHAOLE LIGWW3 CIRCWT UT14 BATTERY BACK-UP AND SHALL NOT BE CGTAIECTED CWO T14E LOAD SIDE OF GFL*V FAULT CIR ,CUT INTERRUPTER ALL °.t'tOKE DETECTORS WITHIN EACH WIT SHALL. BE ITERCC1+ECTEO(AFCI PROTECTED) 2-51OKE DETECTOR SHALL NOT BE PLACED WITHIN 3Ft. OF ANY A/C GRILL. 3-50OKE DETECTORS LOCATED CUTSIDE OF SLEEPING AREAS SHALL NOT BE PLACED CLOOER THAN 3FT. TO SATFP DOOR 4-THE MORNTIIG AND LOCATION OF WIT 91CKE DETECTM SHALL COMPLY WITH WA 12 5EC2-5216 . CELM MOLWS NOT LE66 THAN 4' FROM A UVLL-WAIL MOLNT6 NOT LE66 THAN 4' FROM CEILING NOR MORE THA 0' TO TOP OF DETECTOR 20.71 KW (86A) QP (METAL) 5/6' COPpERC GROW ROD 10 FT. LONG (a) l20r24OV PANEL "C' 100A M.L.O. 1 PH, 3W (2nd FLOOR) FLUSH M.T.D. BRANCH CIRCUITS LOCATION WIRE AND CONDUIT TOTAL BREAKER TRIP CKT NO. CKT NO. BREAKER TRIP TOTAL WIRE AND CONDUIT LOCATION VA VA BEDROOM No.1 #12-112"C * 1P-20 1 2 2P 3000 3#8-3/4"C W. HTR. No.1 3 4 40 3000 No.2 No.2 5 6 1P-20 900 412-M1/2"C FLOODLIGHTS No. 2 7 8 1 P-20 900 SPARE MASTER BEDROOM 9 10 1P-20 * #12 -1/2"C BATH RECEPT. 11 12 1 P-20 * #12 -1/2"C BATH RECEPT. 13 14 SPACE DEN / CORRIDOR 15 16 DEN / CORRIDOR 17 18 SPARE 900 1 19 20 11 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 * 2400 S.F. 7200 SUBTOTAL 8100 TOTAL = 15,900 7,800 SUBTOTAL ELECTRICAL NOTES DEMAND LOAD: 15.9 FIRSTIOKW@100% = 10.0 5.9 KW @ 40 % = 2.36 L ALL ELECTRICAL WORK 6HALL BE IN ACCORDANCE UT14 THE NATIONAL ELECTRICAL CODE AND ALL APPLICABLE LOCAL CODE6. 2. COORDINATE ELECTRICAL SERVICE W/FLORIDA POWER AND LIGHT COMPANY. 3. ALL TELEPHONE RIELATED EQUIPMENT PER UeC 4502.2(AXII) AND ANSI/EIA/TIA-510 4, ELECTRICAL INSTALLATION DESIGN OF THIS PLAN N IN COM- PLIANCE A$ SET FORTM BY STATE OF FLORIDA STATUTE$ MODEL ENERGY EFFICIENCY CODE6. 5. THE CONTRACTOR WILL EXAMINE THE JOB 61TE AND DETEFRMINE FOR HIMSELF PRIOR TO SUBMI6610N OF BID EXISTNG CONDITION$. 6. ALL ELECTRICAL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR IT WILL BE HIS RESPONSIBILITY TO SECURE AND PAY FOR ANY PERMIT$, CERTICATES OF INSPECTION, AS REQUIRED. (a) 1. SUBSTITUTE MATERIALS EQUIPMENT OR METHODS SHALL NOT BE MADE WITHOUT APPROVAL OF THE ENGINEER IF THE USE OF A (a) SUBSTITUTE REQUIRES, ANY CHANGE IN WORK. THE NECE65ARY FOR SUCH CHANGE WILL BE BROUGHT TO THE ATTENTION OF THE ENCst- NEER AND RF APPROVED, SHALL BE MADE AT NO COST TO THE OWNER (a) a. CLEAN UP 6UC 4 TRASH AND DEBRIS GENERATED BY THE WORK AND LEAVE COMPLETED WOW-. N A CLEAN, UNDAMAGED, AND FINISHED (a) CONDITION READY TO RECEIVE WITHOUT FURTHER PREPARATION, UNLESS SO SPECIFIED IN OTHER SECTIONS, ANY ADJACENT OR ABUTTING WORK TO BE PERFONVED BY OTHERS. IN I J ELECT. RISER., SCHEDULES & NOTES N.T.S. SCALE: = 12.36 KW (52A) 9. MATERIALS, APPLIANCES, DEVICES AND EQUIPMENT SHALL MEET WITH THE RE0UIREMENT6 OF UNDERURTER6' LABORATORIE6 AND SHALL ESE NEW AND THE LATEST STANDARD FRODUCT$ OF MANUFAC- TURERS REGULARLY ENGAGED IN THE PRODUCTION OF THE ITEM, UNLESS OTHERWISE INDICATED. LIKE ITEMS SHALL BE THE PRO- DUCT OF A SINGLE MAhAFACTURER 10. ALL CONDUCTORS SHALL BE COPPER AND RUN IN CONDUIIT. WIRE SIZE SMALL 15E TWWN UNLESS OTHERWISE NOTED ON PLANS PROVIDE GROLND CONDUCTOR PER NEC ARTICLE 250422. IL LOCATION OR OULET$ IN ELECTRICAL DRAWINGS 15 DIAGRAMMATIC: CHECK MANUFACTURER'S DRAWING FOR EXACT LOCATION OF OUTLETS. 12. PROVIDE TYPEURITEN SCHEDULE$ FOR ALL PANELBOARD$. COMPLY W/ SFBC 43,04.4 13. A/C EQUIPMENT WIRING, BREAKER AND FUSE 61ZE6 ARE BASED ON A/C EQUIPMENT SPECIFIED ON ORIGINAL CONTRACT DRAWINGS. CON- TRACTOR IS RESPONSIBLE FOR PROVIDING ALL WIRING, BREAKER AND FUSE$ SIZES IN ACCORDANCE WITH A/C EQUIPMENT NAMEPLATE REQUIREMENTS 3F DIFFERENT FROM THAT SPECIFIED ON DRAWItJG6, AS WELL AS ANY FEEDER C44ANGE6 BEING AFFECTED BY THIS CHANGE CONTRACTOR SHALL MAKE ABOVE MENTIONED C 4ANGES AT NO EXTRA COST. HACR CIRCUIT BREAKERS MAY BE USED N PLACE OF FUSES. USE NON -AUTOMATIC SWITCH FOR A/C COND. DISCONNECT. (COMPLY WMEC 110-26) 14. ALL SMOKE DETECTORS TO BE INTERCONNECTED ON SAME CKT (KITCHEN OR BATH LTG.) 15. RANGE AND DRYER SHALL HAVE BOTH NEUTRAL A GROUNDING WIRE PER NEC ARTICLE 250-t40. 16. ALL BEDROOM OUTLETS SMALL DE PROTECTED BY AN 'ARC -FAULT CIRCUIT NTERI2UPTOR°.(AFCI) 2 P-125A TRANSFER SWITCH PNL FNL FNL FNL B C CA EM ■ P'I.2 M-3 M-4 3"I,1#6 GRD 211C I 25 KW 2P-125A � �. SEpA TELY NON -DERIVED 5Y9TE11 JOB #: 05-074 GUERRERO/GONZALEZ ENGINEERS, INC. Michael C. Guerrero, P.E. 11L_ moms Mechanical Eng. Lie. /15235 Rafael L Gonzalez, P.E. Electrical Eng. Lie. #11057 4300 S.W. 73rd Avenue, Suite %107A Miami, Flondo 33155 Tel. (305) 262-3944, Fax (305) 262-8211 E-mail: PROJECTS®GUERREROGONZALEZENGWEERS.COM 4901 S.W.75th Avenue Miami, Florida 33155 T 305.740.0554 F 305.740.5355 jrmainc@bellsouth.net REVISIONS DATE BY ` ,,, �:;�' . • � � ,' g Igo y'�y` . yG�l.. i. a SEAL Drawings and Specifications as instrument of M R & M RS . P I NO service are and shall remain the property of the Architect and shall remain the properly RESIDENCE. of the Architect whether the project for which they were made is executed or not. They are not to be used in any mariner on other projects or extensions to this project except by agreement in writing and with the MR. 8. MRS. PINO appropriate compensation to the Architect. 6864 SW 68 th ST., Reproduction of drawings and Miami, FL 33155 specifications without the written consent of Mr. Patricia Espinosa. the Architect is prohibited 305. SECOND FLOOR PLAN SCALE: 3/16"=V-O" DATE: 06-1-05 DRAWN: M.A.R.