05-1298(2)-008LEGEND
IIIIIIIIIilllllll NEW 12"CMU WALL
NEW 8" CMU WALL
WROOMMOMM NEW 4" METAL STUD
PARTITION WALL
NEW METAL STUD PARTITION WALL.
REFER TO FLOOR PLAN FOR SIZE
(� NEW COLUMN. REFER TO
�J ELEVATIONS AND DETAILS FOR SIZE
0 NEW COLUMN. REFER TO
ELEVATIONS AND DETAILS FOR SIZE
NOTE:
EMERGENCY WINDOW -SILL LOCATED 44"
A.F.F MAX.
REFER TO SHT A 8.1 FOR EMERGENCY
WINDOWS.
GARAGE NOTES:
1407.6 (A.) SIGN REQUIRED: PROVIDE A
PERMANENT SIGN IN A READILY VISIBLE
LOCATION WITHIN THE GARAGE ON THE
INSIDE FACE OF ANY ONE DOOR TO THE
OUTSIDE OF THE ENCLOSURE READING:
DANGER! DO NOT OPERATE ENGINES
WITH DOOR CLOSED. CARBON
MONOXIDE EMISSION IS LETHAL.
GARAGE CEILING TO BE TWO -LAYERS OF
5/8" TYPE "X" GYPSUM LATH ON 1"X 3"
FURRING (OR 7/8" HIGH HATS) @ 16" O.C.
MAXIMUM, WITH 6D CEMENT COATED
NAILS 6" O.C. WITH BUTT & SIDE JOINTS
STAGGERED, PAPER TAPE EMBEDDED
OVER JOINTS AND EXPOSED NAIL HEADS
COVER WITH COMPOUND. (14 HOUR FIRE
RATED CEILING ASSEMBLY).
GARAGE WALLS TO BE 14 FIRE RATED
WALL.
PROVIDE (2) SCREENED VENT BLOCKS OF
60 SQ.IN. EACH TOTAL OF 120 SQ. IN.
PROVIDE 2" X 6" P.T. WOOD JAMB @ EA.
SIDE OF GARAGE DOORS W/ 1 /2" X 6"
LONG ANCHOR BOLTS @ 24" O.C. (BEGIN
6" FROM BOTTOM & TOP).
PROVIDE ADEQUATE STEEL FRAME
SUPPORT FOR ELECTRIC GARAGE DOOR
OPENER AS REQ'D BY MANUFACTURER.
DOORS AND WINDOWS NOTE:
- ALL EXTERIOR DOOR AND WINDOW
OPENINGS SIZE & LOCATION TO BE
COORDINATED WITH WINDOW
SCHEDULE, STRUCTURAL DRAWINGS &
MANUFACTURER'S REQUIREMENTS.
-ARCHITECT TO BE NOTIFIED IN CASE OF
ANY DISCREPANCIES.
TERMITE PROTECTION:
SHALL BE PROVIDED BY REGISTERED
TERMITICIDES, INCLUDING SOIL
APPLIED PESTICIDES, BAITING
SYSTEMS, AND PESTICIDES APPLIED
TO WOOD, OR OTHER APPROVED
METHODS OF TERMITE PROTECTION
LABELED FOR USE AS A PREVENTATIVE
TREATMENT TO NEW CONSTRUCTION.
SEE SECTION 202, REGISTERED
TERMITICIDE. UPON COMPLETION OF
THE APPLICATION OF THE
COMPLIANCE SHALL BE ISSUED TO
THE BUILDING DEPARTMENT BY THE
LICENSED PEST CONTROL COMPANY
THAT CONTAINS THE FOLLOWING
STATEMENT: "THE BUILDING HAS
RECEIVED A COMPLETE TREATMENT
FOR THE PREVENTION OF
SUBTERRANEAN TERMITES.
TREATMENT IS IN ACCORDANCE
WITH RULES AND LAWS ESTABLISHED
BY THE FLORIDA DEPARTMENT OF
AGRICULTURE AND CONSUMER
SERVICES."
FIREPLACE:
FIREPLACE MANUFACTURER SHALL
SUBMIT SHOP DRAWINGS FOR FINAL
REVIEW & APPROVAL BY ARCHITECT
& BUILDING DEPT. FIRE PLACE SHALL
COMPLY W/ F.B.C. 2001 SECT. 2114.
FLOOR PLAN
JOHN R. MEDINA & ASSOC.
A R C H I f E C T S
4901 S.W.751h Avenue
Miami, Florida 33155
T 305.740.0554
F 305.740.5355
jrmainc@bellsouth.net
REVISIONS DATE
N
4-�
U"
0
^, o
V! o
4-Q
U
Q
I
()
W
P.M
U_
ry
Drawings and Specifications as instrument of
service are and shall remain the property of
the Architect and shall remain the property
of the Architect whether the project for
which they were made is executed or not.
They are not to be used in any manner on
other projects or extensions to this project
except by agreement in writing and with the
appropriate compensation to the Architect.
Reproduction of drawings and
specifications without the written consent of
the Architect is prohibited.
FIRST FLOOR
BY
MR & MRS. PINO
RESIDENCE.
MR. & MRS. PINO
6864 SW 68 th ST.,
Miami, FL 33155
Contact: Mr. Henry Pino.
305.573.7140
SCALE: 3/16"=1'-0"
DATE: 05-07
DRAWN: CAP