05-1298(2)-004GENERAL NOTES: THE ARCHITECT OF RECORD DOES NOT ASSUME ANY CONTROL OR CHARGE, AND SHALL NOT BE RESPONSIBLE FOR SUPERVISION OF CONSTRUCTION, MEANS, TECHNIQUES. SEQUENCES AND PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH CONSTRUCTION WORK, FOR THE ACTS OF OMISSIONS OF THE CONTRACTOR, SUBCONTRACTORS OR ANY OTHER PERSONS PERFORMING ANY WORK, OR FOR FAILURE OF ANY OF THEM TO CARRY OUT THE WORK IN ACCORDANCE WITH PLANS AND SPECIFICATIONS. THE ARCHITECT OF RECORD SHALL BE AFFORDED THE 01006RTUNITY TO PROVIDE CONSTRUCTION OBSERVATION SERVICE DURING THE CONSTRUCTION PROCESS. IN THE EVENT THE ARCHITECT OF RECORD IS NOT RETAINED IN THIS CAPACITY, THE ARCHITECT OF RECORD CAN ASSUME NO RESPONSIBILITY FOR THE PROJECT PERFORMANCE DEFECTS. CONFLICTING FIELD CONDITIONS, AND NON CONFORMANCE WITH THE RECOMMENDATIONS PROVIDED HEREIN. GENERAL 1) THIS PROJECT SHALL CONFORM TO THE LATEST EDITION OF THE GOVERNING BUILDING CODE, AND ALL OTHER FEDERAL, STATE, COUNTY, AND LOCAL ORDINANCES, RULES AND REGULATIONS IN EFFECT. ALL THOSE CODES AND REGULATIONS SHALL TAKE PRECEDENCE OVER DRAWINGS. REPORT ALL DISCREPANCIES (IF) ANY TO THE ARCHITECT. LIFE SAFETY 1) ALL EXIT DOORS SHALL HAVE HARWARE PER N.F.P.A. 101, 5-2.1.5 2) ALL NEW WALLS, CEILING GRIDS, LIGHTS, CONDUITS, PIPES, DUCTS AND WIRES, TO BE BRACED, STRAPPED AND/OR SUPPORTED PER CODE, U.L. AND MANUFACTURER SPECIFICATIONS. GENERAL CONTRACTOR AND SUBCONTRACTORS NOTES A) GENERAL RESPONSIBILITIES 1) EACH CONTRACTOR AND SUBCONTRACTOR SHALL VISIT THE SITE AND EXISTING FACILITIES TO DETERMINE THE EXTENT OF THE WORK. IT SHALL BE THE RESPONSIBILITY OF EACH CONTRACTOR TO THOROUGHLY EXAMINE AND VERIFY EXISTING CONDITIONS AND TO MAKE ALLOWANCES FOR THEM PRIOR TO BIDDING. IF THE NEW WORK IS NOT COMPATIBLE WITH THE EXISTING CONDITIONS, THE CONTRACTOR SHALL INFORM THE ARCHITECT PRIOR TO BIDDING. ONCE THE WORK HAS BEGUN, THE CONTRACTOR SHALL BEAR THE RESPONSIBILITY FOR PROPER FIT AND FINISH. 2) GENERAL CONTRACTOR AND SUBCONTRACTORS SHALL REVIEW DRAWINGS PRIOR TO BIDDING AND CONSTRUCTION AND REPORT ANY DISCREPANCIES TO THE ARCHITECT BEFORE SUBMITTING A BID. 3) GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND REPORT ANY DISCREPANCIES TO THE ARCHITECT. 4) TH!S PROJECT SHALL CONFORM TO THE LATEST EDITION OF THE GOVERNING BUILDING CODE, AND ALL OTHER FEDERAL, STATE, COUNTY, AND LOCAL CODES, ORDINANCES, RULES, AND REGULATIONS IN EFFECT. ALL THOSE CODES AND REGULATIONS SHALL TAKE PRECEDENCE OVER DRAWINGS. REPORT ANY DISCREPANCIES TO THE ARCHITECT. 5) DIMENSIONS AS INDICATED ON THE DRAWINGS SHALL TAKE PRECEDENCE OVER SCALING OF THE DRAWINGS. 6) THESE DRAWINGS DO NOT SHOW EVERY MINOR DETAIL OF CONSTRUCTION. THE CONTRACTOR SHALL FURNISH AND INSTALL ALL ITEMS REQUIRED FOR A COMPLETE, PROPERLY FUNCTIONING BUILDING SYSTEM, AND SHALL FULFILL ALL REQUIREMENTS FOR ALL EQUIPMENT TO BE PLACED IN PROPER WORKING ORDER. CONTRACTOR'S BID SHALL INCLUDE ALL ITEMS AND WORK TO ASSURE COMPLIANCE WITH MOST STRINGENT REQUIREMENTS OF GOVERNING BUILDING CODES AND REGULATIONS. 7) EACH CONTRACTOR AND SUBCONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY AND WELL-BEING OF HIS EMPLOYEES AND SHALL STRICTLY FOLLOW ALL CONSTRUCTION SAFETY REGULATIONS, INCLUDING OSHA. 8) ALL CONTRACTORS AND SUBCONTRACTORS SHALL BE CURRENTLY LICENSED IN THE STATE OF FLORIDA, COUNTY HAVING JURISDICTION, AND LOCAL CITIES AS REQUIRED. PROVIDE COPIES OF LICENSES TO OWNER PRIOR TO COMMENCEMENT OF WORK. 9) ALL CONTRACTORS AND SUBCONTRACTORS SHALL CARRY THE MINIMUM WORKMAN'S COMPENSATION, LIABILITY, AND AUTOMOBILE INSURANCE REQUIRED BY THE STATE OF FLORIDA AND HIGHER LIMITS IF REQUIRED BY THE OWNER. PROVIDE INSURANCE CERTIFICATES TO OWNER BEFORE COMMENCEMENT OF WORK. 10) SHOULD THE SCOPE OF WORK, FOR ANY REASON NOT BE FULLY INDICATED ON THE DRAWINGS, THE CONTRACTOR SHALL IMMEDIATELY CONTACT ARCHITECT FOR CLARIFICATIONS. 11) THE WORK SHALL BE LIMITED TO THE SCOPE INDICATED IN THE DRAWINGS AND SPECIFICATIONS. IF ANY ADDITIONAL WORK IS PERFORMED WITHOUT ARCHITECT'S OR OWNER'S APPROVAL, IT SHALL BE AT THE SOLE EXPENSE OF THE CONTRACTOR. 12L CONTRACTOR SHALL PAY FOR AND OBTAIN ALL PERMITS AND SECURE ALL CERTIFICATES OF INSPECTIONS AND CERTIFICATES OF OCCUPANCY THAT ARE REQUIRED BY GOVERNING JURISDICTION. 13) ANY DEVIATION AND/OR SUBSTITUTION FROM THE INFORMATION AND INSTRUCTIONS PROVIDED HEREIN SHALL BE SUBMITTED TO THE ARCHITECT FOR HIS APPROVAL PRIOR TO THE PERFORMANCE OF THE WORK. 14) THE CONTRACTOR SHALL COORDINATE THE OWNER SUPPLIED ITEMS, AND INCORPORATE IT INTO CONTRACTOR'S WORK SCHEDULE. VERIFY SCOPE OF SUCH ITEMS PRIOR TO BID SUBMITTAL. 15) THE CONTRACTOR SHALL INCLUDE INTO BID AND PROVIDE ALL TEMPORARY UTILITIES REQUIRED FOR THE WORK COMPLETION. 16) EACH CONTRACTOR SHALL PROTECT ITS OWN WORK AND WORK OF OTHER CONTRACTORS. ALL CONFLICT TO BE BY THE GENERAL CONTRACTOR. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR FULL COORDINATION OF WORK OF ALL TRADES. ANY DAMAGES RESULTING FROM LACK OF COORDINATION, LACK OF WORK PROTECTION SHALL BE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR, THAT INCLUDES ALL DAMAGES FROM WEATHER, WATER AND DUST. 17) THE CONTRACTOR SHALL EXPEDITE AND SCHEDULE THE DELIVERY OF LONG LEAD ITEMS TO CONFORM WITH THE WORK SCHEDULE. 18) THE CONTRACTOR SHALL WARRANT AND GUARANTEE ALL WORK, ALL COMPONENT PERFORMANCE, AND ALL MATERIALS FOR ONE YEAR FROM THE DATE SHOWN ON THE CERTIFICATE OF OCCUPANCY. 19) ALL WOOD IN CONTACT WITH MASONRY SHALL BE PRESSURE -TREATED, WOOD CASING, JAMBS AND TRIM SHALL BE STAINED GRAY OR CLEAR UNLESS SPECIFIED OTHERWISE. 20) COMPLETION: CONTRACTOR TO NOTIFY OWNER AND/OR ARCHITECT IN WRITING AT LEAST ONE WEEK PRIOR TO FINAL INSPECTION. FINAL DISBURSEMENT TO CONTRACTOR SHALL NOT BE MADE UNTIL OWNERS PUNCH LIST HAS BEEN SATISFIED. CONTRACTOR TO PROVIDE OWNER WITH WRITTEN GUARANTEE ON ALL EQUIPMENT. CONTRACTOR AT COMPLETION OF WORK SHALL REMOVE FROM THE PREMISES ALL RUBBISH, IMPLEMENTS, EQUIPMENT, AND SURPLUS MATERIALS, LEAVE THE PROJECT "BROOM CLEAN". 21) G.C. TO COORDINATE STRUCTURAL DRAWING TOGETHER WITH ARCHITECTURAL, A/C, ELECTRICAL AND MECHANICAL DWGS, TO LOCATE OPENINGS, DRAINS, SLEEVES, SLOPES, DEPRESSED SLAB, BOLTS, CURBS, ETC. CONTACT ARCHITECT IN CASE OF DISCREPANCY. 22)G.C. SHALL OBTAIN THE LATEST SET OF DRAWING, INCLUDING ANY REVISIONS, BEFORE COMMENCING WORK NO CHANGES OR SUBSTITUTIONS SHALL BE MADE WITHOUT THE WRITTEN PERMISSION OF THE OWNER/ARCHITECT/INTERIOR DESIGNER. 23) THE ARCHITECTURAL AND STRUCTURAL DRAWING SHALL GOVERN THE LOCATIONS OF THE INSTALLATION OF THE MECHANICAL AND ELECTRICAL SISTEM. CONTRACTOR MUST INFORM THE ARCHITECT BEFORE FORMING ANY CONCRETE BEAM IF INTERFERING WITH A/C DUCT OR PLUMBING FIXTURES EXACT LOCATION ANY DEVIATION FROM THE MECHANICAL/ELECTRICAL PLANS TO ACCOMODATE THE ABOVE CONDITIONS SHALL BE MADE WITHOUT ADDITIONAL COST TO THE OWNER. 24) THE CONTRACTOR MUST FURNISH ALL LABOR, TOOLS, MATERIALS AND EQUIPMENT NECESSARY TO EXECUTE THE CONSTRUCTION OF THIS JOB. 25) ANY OTHER SERVICES NECESSARY FOR THE COMPLETION OF THIS JOB THAT MAY BE INVOLUNTARY UNDER THE JURISDICTION OF 'THE FLORIDA BUILDING CODE 2001" AND NOT SPECIFIED IN THE "GENERAL NOTES AND/OR SPECIFICATIONS" ARE THE CONTRACTOR'S SOLE RESPONSABILITY. 26) FIXED GLASS AND/OR OPERABLE WINDOW WITHIN 24" OF THE FINISH FLOOR SHALL BE "CAT. II" SAFETY GLASS. 27) ALL INTERIOR FINISHES SHALL BE IN ACCORDANCE WITH CHAPTER VII OF THE STANDARD BUILDING CODE. 28) THE CONTRACTOR SHALL PROVIDE ALL SUPPLEMENTAL MATERIAL REQUIRED TO PROPERLY INSTALL SUPPORT AND BRACE ALL ITEMS AND COMPONENTS WITHIN THE WORK AS PRT OF THE CONTRACT SUM. 29) ALL REQUIRED TESTS SHALL BE PERFORMED AT THE EXPENSE OF THE CONTRACTOR AND BY AN APPROVED TESTING LABORATORY. TEST RESULTS SHALL BE SUBMITTED TO THE ARCHITECT. 30) G.0 TO COORDINATE (OWNER TO PURCHASE) TO PROVIDE A SETBACK SURVEY PRIOR TO INSTALLATION OF CONCRETE FUNDATION. 31) G.0 TO COORDINATE (OWNER TO PURCHASE) TO PROVIDE A SETBACK SURVEY AFTER INSTALLATION OF CONCRETE WALLS AND PRIOR TO FIRST FLOOR TIE BEAMS ARE FORMED. 32) G.0 TO COORDINATE (OWNER TO PURCHASE) AN ELEVATION CERTIFICATE AFTER GROUND FLOOR IS PREPARED/ FORMED BUT PRIOR TO GROUND FLOOR BEING POURED/ INSTALLED. 33) DOORS & WINDOWS: -FIXED GLASS AND/OR OPERABLE WINDOW WITHIN 24" OF THE FINISH FLOOR SHALL BE SAFETY GLASS. - THE WIND LOAD CALCULATIONS,MASONRY OPENINGS AND MULLIONS REFLECTED IN THE ARCHITECTURAL DRAWINGS WILL NOT BE CONSIDERED FINAL UNTIL THE SHOP DRAWINGS HAVE RECEIVED FINAL APPROVAL FROM THE BUILDING AND ZONING DEPARTMENT. -IN THE EVENT THAT THE WINDOWS AND DOORS ARE ORDERED AND/OR INSTALLED (WITHOUT RECEIVING PERMIT FROM CITY)THE G.0 WILL BE COMPLETELY RESPONSIBLE FOR ANY DISCREPANCIES THAT MAY RESULT FROM NOT HAVING APPROVED SET OF SHOP DRAWINGS BY THE BUILDING DEPT. - ALL WINDOW AND DOOR SIZES ARE AS PER DOORS & WINDOWS SCHEDULE UNLESS SPECIFIED OTHERWISE, VERIFY MANUFACTURER'S ACTUAL AND ROUGH OPENING DIMENSIONS IF THE SIZE OF WINDOWS ARE MODIFIED TO REMIND (REQUIERED APPROVAL FROM ARCHITECT), THE G.C. WILL. MODIFIED ROUGH OPENINGS AT NO ADDITIONAL COST TO THE CLIENT. 34) INSULATE MASONRY WALL, EXTERIOR STUD WALL, AND ATTIC SPACE SHALL BE IN ACCORDANCE WITH THE ENERGY CODE CALCULATIONS. 35) CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR ALL CUSTOM FABRICATED WORK. CONTRACTOR SHALL REVIEW/ APPROVE ALL SUBMITTALS/SHOP DRAWINGS PRIOR TO SUBMITTING FOR ARCHITECTS REVIEW. SHOP DRAWINGS MUST BE APPROVED BY THE ARCHITECT PRIOR TO BIDDING. 36) ALL BUILDINGS SHALL HAVE COMPLETE PRECONSTRUCTION IN TREATMENT PROTECTION AGAINST TERMITES (AS PER 1816.1.7 FBC.) 37)GLAZING ON EXTERIOR DOORS AND SIDELIGHTS SHALL BE "CATEGORY II SAFETY GLASS" AS PER 2411.3.1.3 FBC. 38) GLAZING OF SHOWERS/TUB SHALL BE " CATEGORY II SAFETY GLASS" AS PER 2405.2 FBC. 39) ALL WALL HUNG FIXTURES AND CABINETS SHALL BE SUPPORTED IN A SECURED & RIGID MANI=R AS PER 2110.5 FBC. TYPICAL. B) SCHEDULES, ORGANIZATION AND COORDINATION 1) COORDINATE WITH BUILDING MANAGER BY BUILDING NEIGHBOR AND BUILDING OCCUPANTS FOR USE OF POWER WORKING HOURS, ROUTES FOR WORKMAN'S TRAVEL. LOCATIONS OF DUMPSTER'S AND CONSTRUCTION VEHICLES, ETC. 2) THE CONTRACTOR SHALL PREPARE THE JOBSITE PARTITION LAYOUT FOR REVIEW OF ARCHITECT PRIOR TO ERECTION OF PARTITIONS. NOTIFY ARCHITECT TO SCHEDULE INSPECTION 24 HOURS IN ADVANCE. 3) CONTRACTOR SHAL BE RESPONSIBLE FOR SCHEDULING AND IMPLEMENTING ALL WORK SO AS NOT TO DISRUPT OR INCONVENIENCE ANY EXISTING OCCUPANTS/OR NEIGHBOR. 4) ALL ACTIVITIES GENERATING EXCESSIVE NOISE, WHICH WOULD INTERFERE WITH TENANTS RIGHTS TO OCCUPANCY OR NEIGHBOR, MUST BE SCHEDULED AFTER NORMAL WORKING HOURS. 5) ANY DISRUPTION OF UTILITIES WHICH WOULD IMPACT OCCUPIED AREAS MUST BE SCHEDULED AFTER NORMAL WORKING HOURS. COORDINATE WITH THE BUILDING MANAGER AND OR NEIGHBOR 6) CONTRACTOR SHALL PROVIDE BUILDING OWNER AND/OR AFFECTED TENANTS WITH A SCHEDULE OF CONSTRUCTION, A LIST OF PERSONNEL AND SUBCONTRACTORS, AND PHONE NUMBERS FOR CONTACTING APPROPRIATE MANAGEMENT PERSONNEL DURING REGULAR HOURS AND IN CASES OF EMERGENCY AFTER HOURS. C) CLEANING REQUIREMENT 1) THE JOB SITE SHALL BE MAINTAINED IN A SAFE AND NEAT CONDITION AT ALL TIMES. BROOM CLEANING SHALL BE PERFORMED AS NEEDED TO AVOID DEBRIS BUILD UP. 2) ALL BUILDING MATERIALS SHALL BE STORED IN A SAFE AND ORGANIZED MANNER SO AS NOT EO INTERFERE WITH THE WORK OF OTHER TRADES. 3) AT PROJECT COMPLETION, THE JOB SITE SHALL BE FULLY CLEANED AND TURNED OVER TO OCCUPANT READY FOR THEM TO MOVE IN AND BEGIN OPERATING WITHOUT ANY ADDITIONAL WORK OR CLEANING. THIS REQUIRES ALL SURFACES TO BE CLEANED WITH APPROPRIATE CLEANING SOLUTIONS, VACUUMED, AND WAXED/SEALED AS APPROPRIATE. ALL VCT SHALL BE SEALED AND WAXED. ALL MIRRORS, WINDOWS, HARDWARE, CABINETRY, WALL FINISHES AND FIXTURES ARE INCLUDED. D)ROOF PENETRATIONS. 1) ANY ROOF PENETRATIONS SUCH AS VENTS, CHIMNEYS EQUIPMENT CURBS AND SKYLIGHTS REQUIRED SHALL BE FLASHED AND SEALED TO BE WATER TIGHT. IF ROOF IS UNDER WARRANTY OR BONDED, THE GENERAL CONTRACTOR SHALL HIRE THE WARRANTING ROOFING OR BONDING COMPANY TO PERFORM ALL ROOF MODIFICATION WORK (IF APPLICABLE). SITE NOTES: 1) ALL APPROACHES TO BE COORDINATED WITH STREET TREES, STREET LIGHTS, FIRE HYDRANTS, ETC. 2) LANSCAPING SHALL COMPLY WITH ORDINANCE 98.13 CHAPTER 18-A OF CODE/ FLORIDA LANSCAPE ORDINANCE. 3) ALL AREA MARKED "SOD" TO BE SODDED PER LANSCAPING PLANS (IF APPLICABLE). CONSTRUCTION SPECIFICATIONS GENERAL WORKMANSHIP 1) ALL MANUFACTURER'S RECOMMENDED INSTALLATION INSTRUCTIONS AND SPECIFICATIONS ARE INCORPORATED BY REFERENCE FOR ALL MATERIALS INSTALLED. THIS INCLUDES U. S. GYPSUM MANUALS FOR DRYWALL, ARMSTRONG SPECIFICATIONS FOR THE ACOUSTICAL CEILING SYSTEM., UL SPECIFICATIONS FOR RATED WALL ASSEMBLIES, BENJAMIN MOORE SPECIFICATIONS FOR PAINT, AND HVAC, ELECTRICAL AND PLUMBING EQUIPMENT MANUFACTURERS SPECIFICATIONS. 2) ALL MATERIALS, PRODUCTS, COMPONENTS AND EQUIPMENT SHALL BE INSTALLED IN A WORKMAN LIKE MANNER, AND COMPLYING WITH APPLICABLE MANUFACTURERS' INSTRUCTIONS AND SPECIFICATIONS. THE CONSTRUCTION, INCLUDING ALL MATERIALS AND LABOR, SHALL CONFORM TO ALL APPLICABLE CITY, COUNTY, AND NATIONAL BUILDING CODES. INTERIOR PARTITIONS 1) UNLESS OTHERWISE SPECIFIED ON THE DRAWINGS, ALL NEW INTERIOR PARTITIONS SHALL BE CONSTRUCTED WITH 25GA GALV. METAL STUDS PLACED @ 16" O.C. MAX. 1 /2' GYPSUM WALL BOARD. AND FIBERGLASS INSULATION FINISH ALL JOINTS AND IMPERFECTIONS WITH TAPE AND 3 COATS OF JOINT COMPOUND. IN AREAS WHERE NEW WALL FILLS VOID IN EXISTING CONSTRUCTION OR WHERE NEW WALL COMPLEMENTS EXISTING, USE GWB OF THICKNESS TO MATCH EXISTING. DEMISING PARTITIONS SHALL RECEIVE 5/8" FIRE CODE GWB AFTER PRIMING, ALL VISIBLE NAIL DIMPLES AND JOINTS ARE TO BE REFINISHED. FINAL PRODUCT MUST BE FINISHED SO JOINTS AND NAIL HOLES ARE NOT VISIBLE/IDENTIFIABLE MORE THAN ONE FOOT AWAY UNDER NORMAL ROOM LIGHTING. 2) EXISTING FIRE RATED SEPARATION WALLS MAY NEED TO BE MODIFIED AND COMPLETED TO MEET UL AND LOCAL BUILDING CODES. ALL EXISTING UNSEALED PENETRATIONS MUST BE PROPERLY SEALED WITH UL APPROVED MATERIALS. ALL EXISTING DUCTWORK DESIGNATED TO REMAIN AND PENETRATING FIRE RATED ASSEMBLIES SHALL BE SUPPLIED WITH FIRE DAMPERS. 3) ALL EXISTING WALLS WITHIN THE CONSTRUCTION AREAS THAT ARE TO REMAIN AND THAT ARE PRESENTLY COVERED WITH WALL COVERING MUST BE STRIPPED AND SKIM COATED TO PROVIDE: A SMOOTH, EVEN, AND LEVEL SURFACE. AFTER SKIM COATING, WALLS MUST BE RE -PRIMED AND RECOVERED WITH FINISH PER CLIENTS FINISH SCHEDULE. 4) EXISTING WALLS, WHICH ARE NOT DEMCLSHED PER PLANS, MUST BE REFINISHED IF THEY DO NOT MEET SPECIFICATIONS OF NEW WALLS. THIS REQUIRES AT MINIMUM: a). ANY HOLES TO BE PATCHED. b). ANY DAMAGED GYPSUM BOARD TO 8E REMOVED AND REPLACED. c). ANY WALLS PREVIOUSLY ABUTTED BY DEMOLISHED WALLS SHALL BE REFINISHED BY LAMINATING WITH NEW LAYER OF GYPSUM BOARD FROM CORNER TO CORNER; AS REQUIRED TO OBTAIN A SMOOTH AND STRAIGHT FINISH WITHOUT BULGES OR PATCH MARKS. REMOVE AND REPLACE DRYWALL WHERE FEASIBLE. APPLICATION OF A ONE -COAT PLASTER SYSTEM 15 AN ACCEPTABLE ALTERNATIVE OR LAMINATING OR REMOVING AND REPLACING DRYWALL. 5) ALL DRYWALL WILL BE INSPECTED AFTER PRIMING BUT BEFORE WALLPAPER INSTALLATION. FINISHES NOT MEETING SPECIFICATIONS WILL BE REJECTED AND MUST BE RE -SKIMMED OR RE-SHEETROCKED UNTIL FINISHES ARE APPROVED BY OWNER OR ARCHITECT. 6) ALL BATHROOMS AND TOILET ROOMS SHALL RECEIVE 5/8" MOISTURE RESISTANT GWIB. THROUGHOUT. FINISHES 1) WALL PAINT SHALL BE WATER BASED SATIN LATEX, ONE PRIMER COAT AND TWO FINISH COATS, BENJAMIN MOORE'S OR APPROVED EQUAL. COLOR AND PLACEMENT PER FINISH SCHEDULE AND/OR OWNER'S INSTRUCTIONS. 2) WALLS TO RECEIVE VWC (IF ANY) SHALL BE PRIMED WITH AN OIL BASE PRIMER THAT MAKES PAPER STRIPPABLE SOLUTION. 3) ALL DOOR FRAMES SHALL RECEIVE BENJAMIN MOORE OIL BASE ENAMEL SEMI GLOSS PAINT (PRIMER AND TWO COATS.) 4) ALL NEW MATERIALS AND/OR PATCHWORK SHALL BE PROVIDED TO MATCH EXISTING MATERIALS AND/OR ADJOINING WORK. 5) ALL INTERIOR WALLS SHALL RECEIVE GYFSUM BOARD OF THICKNESS AS SPECIFIED ON PLANS AND DETAILS. 6) ALL TOILET ROOMS AND POTENTIALLY WIC" AREAS SUCH AS THE KITCHEN, BATHROOM & LAUNDRY SHALL RECEIVE 5/8 MOISTURE RESISTANT GYPSUM BOARD. 7) ALL CEILINGS SHALL BE SEALED SO THAT ,AIR FLOW FROM SHAFTS, WALL CHASES, CAVITIES AND BETWEEN CONDITIONED AND UNCONDITONED ATTIC SPACE IS STOPPED. 8) ALL GYPSUM BOARD WALLS SHALL RECEIVE FINISH PER FINISH SCHEDULE OR OWNER'S INSTRUCTIONS AS APPLICABLE. 9) ALL GYPSUM BOARD WALLS AND CEILINGS SHALL BE TAPED, TROWELED AND POLISHED. 10) ALL OUTSIDE CORNERS AT PARTITIONS SHALL HAVE CORNER BEADS OR ELL BEADS AS APPLICABLE. 11) ALL FINISH WOOD SHALL RECEIVE FINISI I PER DOOR AND FINISH SCHEDULES. 12) ALL DOORS SHALL BE PAINT GRADE, AND ALL WOOD TRIM SHALL BE PAINT GRADE„ UNLESS OTHERWISE SPECIFIED. 13) ALL DOORS, WINDOWS AND ROUGH OPENINGS SHALL BE VERIFIED WITH MANUFACTURER'S SPECIFICATIONS FOR PROPER INSTALLATION. 14) CONCRETE SLABS, NEW OR PATCHES TO EXISTING, SHALL BE TROWELED SMOOTH AND LEVEL. 15) PROVIDE FLOOR PREPARATION TO RECEIVE NEW FLOOR FINISH. THIS SHALL INCLUDE FLUSH PATCHING AND LEVELING AT DOORWAYS PERIMETERS AND SIMILAR AREAS WHICH MIGHT BE OBVIOUS TO THE OWNER/TENANT. 16) PROVIDE FINISHES PER SCHEDULES OR NOTES. OTHERWISE CONFORM TO BUILDING STANDARDS. 17) ALL WOOD IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE TREATED. 18) CONTRACTOR SHALL COORDINATE WITH CABINET SUBCONTRACTOR AND SHALL SUPPLY ALL NECESSARY SUPPORTS AND BLOCKING REQUIRED, READY TO RECEIVE CABINETS ANDfOR SUBSEQUENT FINISHES. 19) ALL DRYWALL, PLASTER AND STUCCO SHALL RECEIVE TWO COATS OF PREMIUM QUALITY PAINT. WOOD SHALL BE PAINTED OR STAINED COLOR TO BE SELECTED BY OWNER. CAULKING & SEALANTS ALL SEAMS, JOINTS AND GAPS BETWEEN MATERIALS ARE TO BE FILLED AND SEALED WITH CAULK, TO INCLUDE BUT NOT LIMITED TO: ALL CAULKING TO BE POLYSEAMSEAL, GE SILICONE, OR ARCHITECT APPROVED EQUAL. CAULK COLOR SHALL MATCH ADJOINING MATERIALS OR SHALL BE PAINTED AS APPROPRIATE. NO SEAMS OVER 1/8" ARE ACCEPTABLE; ADJOINING MATERIALS TO BE REWORKED UNTIL 0/8" OR LESS CAULK BEAD WILL FILL SEAM. 1) DOOR JAMBS WHERE THEY ABUT FLOOR 2) DOOR CASINGS WHERE THEY ABUT DRYWALL AND JAMB MATERIAL 3) BASE MATERIAL WHERE ABUTS FINISHED FLOOR AND WHERE ABU ITING DRYWALL 4) SINKS WHERE ABUTTING ADJOINING MATERIALS (MICA, DRYWALL, TILE) 5) BETWEEN WINDOWS AND DOORS AND THEIR FRAMES. 6) BETWEEN WINDOWS AND DOORS FRAMI=S AND THE SURRONDING WALL. 7) BETWEEN THE FOUNDATION AND WALL ASSEMBLY SILL -PLATES. 8) JOINTS BETWEEN EXTERIOR WALL PANELS AT CHANGES IN PLANE, SUCH AS WITH EXTERIOR SHEATING AT CORNERS AND CHANGES IN ORIENTATION. 9) OPENINGS AND CRACKS AROUND ALL F'E:NETRATIONS THROUGH THE WALL ENVELOPE SUCH AS UTILITY SERVICES AND PLUMBING. 10) BETWEEN THE WALL PANELS AND TOP AND BOTTOM PLATES IN EXTERIOR AND ADJACENT WALLS. IN FRAME CONSTRUCTION, THE CRACK BETWEEN EXTERIOR AND ADJACENT WALLS BOTTOM PLATES AND FLOOR SHALL BE SEALED WITH CAULKING OR GASKET MATERIAL.. GYPSUM BOARD OR OTHER WALL PANELING ON THE: INTERIOR SURFACE OF EXTERIOR AND ADJACENT WALL SHALL BE SEALLED TO THE FLOOR, AND (WHEN APPLICABLE). 11) BETWEEN WALLS AND FLOOR WHERE THE FLOOR PENETRATES TFE WALL. SECURITY AND FORCED ENTRY PREVENTION (FBC) 1. PROVIDE INTRUSION AND BURGLARY SECURITY DEVICES AS SET FORTH IN THE FLORIDA BUILDING CODE. 2. ALL LOCKS ON EXTERIOR DOORS SHALL BE CAPABLE OF RESISTING A FORCE OF 300 LBS. APPLIED IN ANY MOVEABLE DIRECTION AN IN ACCORDANCE WITH RESISTANCE STANDARDS SET FORTH IN THE FLORIDA BUILDING CODE. 3. ALL SINGLE EXTERIOR SWING DOORS SHALL HAVE A LOCK TO BE KEY OPERATED FROM THE EXTERIOR WITH A MINIMUM OF 6000 POSSIBLE KEY CHANGES OR LOCKING AUXILIARY SINGLE DEAD BOLT WITH HARDENED BOLT INSERTS. 4. THE ACTIVE LEAF OF PAIRS OF EXTERIOR 'SWING DOORS SHALL HAVE SAME LOCKS AS REQUIRED FOR SINGLE EXTERIOR R SWING DOORS. THE INACTIVE LE F HALL HAVE MULTIPLIED LTIPLIED W BOLTS WITH INSERTS. WITH 5 C S POINTS OF LOCKS I /8"MIN. THROW F RABBETED R F SIMILAR ''WIN DOORS SHALL B_ R BBE O O S 5. JAMBS OF ALL EXTERIOR OFFSET TYPE INSWING G O FABRICATION TO PREVENT DEFEATING THE PURPOSE OF THE STRIKE AND THE INTEGRITY OF THE LOCKS AND LATCHES. 6. HINGES ON EXTERIOR OUT SWINGING DOORS SHALL HAVE NONREMOVABLE PINS AND NON -EXPOSED SCREWS. 7. GLASS AND EXTERIOR DOORS SHALL COMPLY WITH THE AMERICAN NATIONAL STANDARDS INSTITUTE STANDARD 2971. 8. VISION PANEL EXTERIOR DOORS OTHER THAN GLAZING WITHIN 40" OF THE INSIDE LOCKING ACTIVATING DEVICE OF LOOSE AND SWING DOORS SHALL COMPLY WITH THE AMERIICAN NATIONAL STANDARD INSTITUTE STANDARD 7.971. 9. WINDOWS SHALL BE INSTALLED AND CONSTRUCTED SO THAT NO PANEL CAN BE LIIFTED FROM THE TRACKS WHEN IN THE LOCKED POSITION AND SO AS TO COMPLY WITH THE ARCHITECTURAL ALUMINUM MGS. ASSOCIATION STANDARDS FOR FORCE ENTRY RESISTANCE AAMA 13033 PROVIDE LOCKS AS PER FBA EXTERIOR WINDOW SHALL BE LOCKED WITH DEVICE CAPABLE OF WITHSTANDING A FORCE OF 150LBS. APPLIEED IN AN OPERABLE DIRECTION. 10. EXTERIOR WINDOWS USED AS A MEANS OF ESCAPE SHALL ALSO COMPLY WITH A (DOOR SCOPE OR VISION PANELS. 11. FRONT MAIN ENTRANCE DOORS SHALL BE PROVIDED WITH A DOOR SCOPE OR VIISION PANELS. CABINETRY SUBSTITUTE ITEMS INDICATED "OR EQUAL" TO SPECIFICATIONS SHALL BE SUBMITTED TO THE ARCHITECT FOR APPROVAL PRIOR TO BIDDING. 1) ALL CABINETS SHALL BE WITH HIGH-PRESSURE LAMINATE FINISH. BASE: LAMINATED 5/8"PLWD. 2) CABINET TOPS SHALL BE CONSTRUCTED OF 3/4" PLYWOOD (WET LOCATIONS) WITH HIGH-PRESSURE LAMINATE TOP AND ALL EXPOSED EDGES. ALL EXPOSED OUTSIDE CORNERS SHALL HAVE 3" RADIUS. ALL BACKSPLASHES TO BE 4" UNLESS NOTED OTHERWISE ON DRAWINGS. 3) CABINET DOORS: 5/8" PARTICLE BOARD BALANCED CONSTRUCTION EQUAL SIZED LAMINATE BOTH SIDES. 4) DRAWER FRONTS: 5/8" PARTICLE BOARD LAMINATE BOTH SIDES. SIDES: 1 /2" WHITE MELAMINE. BOTTOMS: 1/8" WHITE MASONITE. 5) INTERIOR CABINET SHELVING: 5/8" VINYL WHITE MELAMINE. 6) FILE DRAWER SLIDES: FILE CABINETS - "ACCURIDE" MODEL 8-83724 OR EQUAL, OTHER DRAWERS - STANDARD SLIDES, 7) PULLS: "STANLEY" MODEL SIMPLICITY (WIRE PULL 4"), FINISH SATIN CHROME. 8) HINGES: "GRANT' MODEL A-1006 OR EQUAL. 9) OPEN SHELVING UNITS: 5/8" PLWD. ALL EXPOSED SIDES (INCLUDING INTERIORS) FINISHED WITH HIGH-PRESSURE LAMINATE. 10) REMOVE AND DISPOSE OF ALL DEMOLISHED CABINETRY. 11) SHOP DRAWINGS AND SAMPLES SHALL BE SUBMITTED TO ARCHITECT BEFORE FABRICATION. MECHANICAL ALL HVAC FIXTURES INDICATED IN ARCHITECTURAL PLANS AND REFLECTED CEILINGS, BUT NOT INDICATED IN HVAC PLANS WILL BE PART OF CONTRACT SUM. THE CONTRACTOR IS RESPONSIBLE FOR INSTALLATION, EQUIPMENT, SUPPLY, RETURN LINES AND FIXTURES, AT NO COST TO THE OWNER FOR ANY INFORMATION REFLECTED ON ARCHITECTURAL PLANS BUT NOT HVAC PLANS. FOR HVAC SPECIFICATIONS SEE HVAC DRAWINGS ELECTRICAL ALL RECEPTACLES & LIGHT FIXTURES INCLUDING ALL APPLIANCES REQUIRING ELECTRICITY INDICATED IN ARCHITECTURAL PLANS BUT NOT INDICATED IN ELECTRICAL PLANS WILL BE PART OF CONTRACT SUM, THE CONTRACTOR IS RESPONSIBLE FOR WIRING, FIXTURES AND INSTALLATION, AT NO COST TO THE OWNER FOR ANY INFORMATION REFLECTED ON ARCHITECTURAL PLANS AND NOT ON ELECTRICAL. ALL WORK REQUIRED BY ARCHITECTURAL PLANS TO COORDINATE WITH WORK IN THE FIELD; TO BE COORDINATED BY GENERAL CONTRACTOR FOR ELECTRICAL SPECIFICATIONS SEE ELECTRICAL DRAWINGS PLUMBING ALL PLUMBING FIXTURES INCLUDING BALLAST, CABLES, CONDUITS REQUIRED, INSTALLATION AND FIXTURE ITSELF INDICATED IN IN ARCHITECTURAL PLANS, BUT NOT INDICATED ON PLUMBING PLANS WILL BE PART OF THE CONTRACT SUM. THE CONTRACTOR IS RESPONSIBLE FOR SUPPLYING THE FIXTURE WITH ALL NESCESARY PLUMBING PARTS AND COMPONENTS NOT ILLUSTRATED AND OR DESCRIBED REQUIRED BY THE FIXTURES. DEMOLITION I. GENERAL CONTRACTOR TO PROVIDE NOTICE TO, AND ACQUIRE ALL NECESSARY PERMITS FROM AGENCIES HAVING JURISDICTION OVER DEMOLITION AND ASBESTOS REMOVAL (IF REQUIRED). 2. REMOVE ROOF, CEILINGS, FLOORS, INTERIOR AND EXTERIOR WALLS AND MATERIALS FROM EXISTING RESIDENCE AS INDICATED ON DRAWINGS. 3. PRIOR TO DEMOLITION VERIFY THAT ALL APPROPRIATE UTILITIES HAVE BEEN DISCONNECTED AND MADE SAFE. 4. EXISTING ELECTRICAL PANELS TO BE REMOVED. 5. REMOVE ALL WIRING FROM DEMOLISHED WALLS. 6. REMOVE AND CAP ALL PLUMBING FIXTURES AND LINES FROM DEMOLISHED WALLS. 7. CONTROL AS MUCH AS POSSIBLE THE SPREAD OF DUST AND DIRT. OBSERVE ENVIRONMENTAL PROTECTION REGULATIONS. 8. PROMPTLY DISPOSE OF MATERIALS RESULTING FROM DEMOLITION OPERATIONS. DO NOT ALLOW MATERIALS TO ACCUMULATE ON SITE. 9. TRANSPORT MATERIALS RESULTING FROM DEMOLITION OPERATIONS AND LEGALLY DISPOSE OF OFF -SITE. 10. UPON COMPLETION OF DEMOLITION OPERATIONS, REMOVE ALL TOOLS AND EQUIPMENT AND DISPOSE OFF -SITE ALL REMAINING DEBRIS. 11. LEAVE ALL AREAS FREE OF DEBRIS. 12. COORDINATE WITH BUILDING'S OWNER ROUTES FOR WORKMEN, LOCATION OF DUMPSTERS, PARKING FOR WORKMEN, AND TIMES OF ANY UTILITY DISRUPTIONS. 13. CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATE BRACING OF ALL STRUCTURAL MEMBERS, WALLS AND NON STRUCTURAL ITEMS DURING CONSTRUCTION. 14. ALL WORK AND MATERIALS SHALL COMPLY WITH THE SOUTH FLORIDA BUILDING CODE (DADE COUNTY EDITION), AND ALL OTHER LOCAL ORDINANCES. 15. CONTRACTOR TO PROVIDE PROPER PRECAUTIONS TO PROTECT ALL UNDERGROUND UTILITY LINES AND EXISTING LANDSCAPE. CONTRACTOR TO BE RESPONSIBLE FOR ALL DAMAGE DURING CONSTRUCTION TO VEGETATION, SITEWORK, AND UTILITY LINES. 16. ALL SHOP DRAWINGS SHALL BE SUBMITTED TO ARCHITECT PRIOR TO FABRICATION FOR APPROVAL. 17. CONTRACTOR SHALL OBTAIN LATEST SET OF DRAWINGS, INCLUDING ANY REVISIONS, BEFORE STARTING CONSTRUCTION. 18. CONTRACTOR TO VERIFY ALL UTILITY LOCATIONS BEFORE COMMENCING THE JOB. 19. CONTRACTOR TO PROVIDE AND BE RESPONSIBLE FOR ADEQUATE SHORING AND SUPPORT NECESSARY PRIOR TO COMMENCING DEMOLITION & DURING CONSTRUCTION. 20. GENERAL CONTRACTOR TO CAREFULLY REMOVE BRICK IN AREAS INDICATED AND TO STORE FOR FUTURE USE AS REQUIRED. GENERAL NOTES G.0 TO INCLUDES IN THE CONTRACT SUM ALL REQUIRED REINFORCING (BACKING) FOR ALL FIXTURES AS RECOMENDED BY PRODUCT SPECIFICATIONS/MANUFACTURER'S (IF G.C. DOES NOT PROVIDE FOR ADDECUATE BACKING WITHIN THE CONTRACT SUM, HE WILL PROVIDE IT AT NO ADDITIONAL COST TO CLIENT). PROVIDE MANUFACTURER SPECIFICATION SHEETS TO THE ARCHITECT PRIOR TO ORDERING. ALL EQUAL SUBSTITUTIONS MUST BE APPROVED BY THE ARCHITECT PRIOR TO BIDDING. THE ARCHITECT OF RECORD DOES NOT ASSUME ANY CONTROL OR CHARGE, AND SHALL NOT BE RESPONSIBLE FOR SUPERVISION OF CONSTRUCTION, MEANS, TECHNIQUES. SEQUENCES AND PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH CONSTRUCTION WORK, FOR THE ACTS OF OMISSIONS OF THE CONTRACTOR, SUBCONTRACTORS OR ANY OTHER PERSONS PERFORMING ANY WORK, OR FOR FAILURE OF ANY OF THEM TO CARRY OUT THE WORK IN ACCORDANCE WITH PLANS AND SPECIFICATIONS. THE ARCHITECT OF RECORD SHALL BE AFFORDED THE OPPORTUNITY TO PROVIDE CONSTRUCTION OBSERVATION SERVICE DURING THE CONSTRUCTION PROCESS. IN THE EVENT THE ARCHITECT OF RECORD IS NOT RETAINED IN THIS CAPACITY, THE ARCHITECT OF RECORD CAN ASSUME NO RESPONSIBILITY FOR THE PROJECT PERFORMANCE DEFECTS. CONFLICTING FIELD CONDITIONS, AND NON CONFORMANCE WITH THE RECOMMENDATIONS PROVIDED HEREIN. THE CONTRACTOR SHALL DESIGN ENGINEER TEST FABRICATE DELIVER INSTALL AND GUARANTEE ALL CONSTRUCTION NECESARRY TO PROVIDE FOR THE BUILDING, INCLUDING ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING AND STRUCTURAL. THE BUILDING SHALL BE COMPLETE IN EVERY RESPECT, INCLUDING ALL MEASURES THAT MAY BE REQUIRED TO THAT END, NOTWITHSTANDING ANY OMISSIONS OR INADEQUACIES OF DRAWINGS AND/OR SPECIFICATIONS. THE CONTRACTOR MAY UTILIZE ALTERNATIVES SYSTEMS, MEANS AND METHODS TO PERFORM THE WORK DESCRIBED HEREIN. IN UTILIZING SUCH ALTERNATIVE SYSTEMS, MEANS AND METHODS, THE CONTRACTOR SHALL NOT DEVIATE FROM THE PROFILES SHOWN ON THE DRAWINGS AND THE PERFORMANCE REQUIREMENTS STATED HEREIN. IT IS RECOGNIZED THAT THE CONTRACT DOCUMENTS DO NOT COVER SOME CONDITIONS OR MODIFICATIONS WHICH MAY BE REQUIRED AND WHICH MAY NOT ACCURATELY REFLECT EXISTING CONDITIONS. IT IS HOWEVER INTENDED THAT THE CONDITIONS NOT DETAILED OR NOT SHOWN ACCURATELY SHALL BE DEVELOPED THROUGH THE TRADE CONTRACTORS SHOP DRAWINGS, REPORTS OR SPECIFICATIONS TO THE SAME LEVEL OF AESTHETICS AND IN COMPLIANCE WITH THE PERFORMANCE CRITERIA AS INDICATED FOR DETAILED AREAS AND STIPULATED IN THESE DOCUMENTS. THE CONTRACTOR, IN PREPARATION OF HIS BID, IS TO VISIT THE SITE AND DETERMINE EXISTING CONDITIONS FOR HIMSELF. THE TRADE CONTRACTOR, BY ACCEPTING A CONTRACT FOR THE WORK, ACKNOWLEDGES THIS AND AGREES THAT THE OWNER AND ARCHITECT SHALL HAVE THE FINAL APPROVAL. THE ARCHITECT OF RECORD RESERVES THE RIGHT TO REJECT THE PROJECT OR ANY PORTION OF THE PROJECT NOT EXECUTED AS PER CONSTRUCTION DOCUMENTS AND SPECIFICATIONS AT ANY MOMENT AFTER COMPLETION OF PROJECT. THE ARCHITECT IS NOT RESPONSIBLE FOR HIS CONSULTANTS ERRORS AND OMISSIONS AND CLAIM CANNOT BE BROUGHT UPON HIM FOR SUCH ERRORS. COMPLETION: CONTRACTOR TO NOTIFY OWNER AND/OR ARCHITECT IN WRITING AT LEAST ONE WEEK PRIOR TO FINAL INSPECTION. FINAL DISBURSEMENT TO CONTRACTOR SHALL NOT BE MADE UNTIL OWNERS PUNCH LIST HAS BEEN SATISFIED. CONTRACTOR TO PROVIDE OWNER WITH WRITTEN GUARANTEE ON ALL EQUIPMENT. CONTRACTOR AT COMPLETION OF WORK SHALL REMOVE FROM THE PREMISES ALL RUBBISH, IMPLEMENTS, EQUIPMENT AND SURPLUS MATERIALS, LEAVE THE PROJECT "BROOM CLEAN." INDEX Dwg. # Sheet Description ARCHITECTURAL 1 Cover Page II Index & General Notes D-1.0 Demolition AS-1.0 Site Plan AS-1.1 Landscaping Site Plan A-1.1 Ground Floor Plan A-1.2 Second Floor Plan A-2.1 Ground Floor Reflected Plan A-2.2 Second Floor Reflected Plan A-3.1 Roof Plan A-4.1 West & North Elevations. A-4.2 East & South Elevations A-4.3 South Elev- Section-5 & Cabana Elevations. A-5.1 Sections A-1 & A-2 A-5.2 Sections A-3 & A-4 A-5.3 Pool Sections A-6.1 Wall Sections A-6.2 Stair & Details A-6.3 Fireplace details A-6.4 Details A-6.5 Details A-6.6 Details A-6.7 Details A-7.1 Kitchen Elevations & Plan A-7.2 Masterbothroom Elevations A-8.1 Window & Door Elevations & Schedules STRUCTURAL Scale Scale: NA Scale: NA Scale: 3/32"=1'-0" Scale: As Shown Scale: 3/32"=V-4T Scale: 3/16" =V-0" Scale: 3/16" =l'-0" Scale: 3/16" =V-0" Scale: 3/16" =1'-G' Scale: 3/16" =1'-0" Scale: 3/16" =1'-0" Scale: 3/16" =1'-0" Scale: 3/16" =1'-0" Scale: 3/16" =1'-0" Scale: 3/16" =1'-U' Scale:3/4"= V-0" Scale:3/4"= V-0" Scale: As Shown Scale: 3X=1'-G' Scale: As Shown Scale: As Shown Scale: As Shown Scale: As Shown Scale: As Shown Scale: As Shown Scale: 1 /4" =1'-G' S-1 General Notes Scale: As Shown S-2 Foundation & Ground Floor Framing Plan Scale: As Shown S-3 Second Floor Framing Plan Scale: As Shown S-4 Roof Framing Plan Scale: As Shown S-5 Schedules & Details Scale: As Shown S-6 Bldg Sections Scale: As Shown S-7 Wall Sections, Stair & Details Scale: As Shown PLUMBING P-1 Plumbing Ground Floor Plan Scale: As Shown P-2 Plumbing Second Floor Plan Scale: As Shown SP-1 Site Plan Scale: As Shown MECHANICAL M-1 HVAC Ground Floor Plan Scale: As Shown M-2 HVAC Second Floor Plan Scale: As Shown MPI Mechanical & Plumbing Details Scale: As Shown ELECTRICAL E-1 Ground Floor Plan - Electrical Scale: 1/4'=1'-0" E-2 Second Floor Plan - Electrical Scale: 1 /4"=V-0" E-3 Electrical, Panels & Schedules Scale: As Shown JOHN R. MEDINA & ASSOC. A R C H I T E C T S 4901 S.W.75th Avenue Miami, Florida 33155 T 305.740.0554 F 305.740.5355 jrmainc@bellsouth.net REVISIONS DATE U" O O O -{-- Q • - U Q nV) W 4-- • �. U O 0 V) Q 06 V W Ln V U LL C O Drawings and Specifications as instrument of service are and shall remain the property of the Architect and shall remain the property of the Architect whether the project for which they were made is executed or not. They are not to be used in any manner on other projects or extensions to this project except by agreement in writing and with the appropriate compensation to the Architect. Reproduction of drawings and specifications without the written consent of the Architect is prohibited. BY MR & MRS. PINO RESIDENCE. MR. & MRS. PINO 6864 SW 68 th ST., Miami, FL 33155 Contact Mr. Henry Pino 305.573.7140 INDEX SCALE: AS SHOWN DATE: 05-07 DRAWN: CAP