07-16R-003PLUMBING NOTES
I. VERIFY ALL SPACE CONDITIONS, DIMENSIONS, DIMENSIONS AND PIPE SIZES AT
PROJECT SITE PRIOR TO FABRICATION ANS INSTALLATION OF MATERIALS AND
EQUIPMENT,
2. COORDINATE WORK WITH OTHER TRADES.
3. PLUMBING CONTRACTOR SHALL PAY ALL FEES, INSPECTION AND CONNECTION
CHARGES REQUIRED.
4. SUBMIT SHOP DRAWINGS TO ARCHITECT FOR APPROVAL OF ALL EQUIPMENT,
MATERIALS AND LAYOUT PRIOR TO INSTALLATION.
5. PLUMBING CONTRACTOR SHALL GUARANTEE ALL WORK FREE OF DEFECTS IN
MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM DATE
OF ACCEPTANCE.
6. PROVIDE SHUT OFF VALVE FOR EACH FIXTURE AND Alit CHAMBERS WHERE
SHOWN ON DRAWINGS AND WHERE REQUIRED FOR PROPER PERFORMANCE
OF THE SYSTEM.
7. PROVIDE DIELECTRIC FITTINGS TO CONNECT PIPING OR EQUIPMENT OF
DISSIMILAR METALS.
8. HOSE BIBBS SHALL BE INSTALLED 2'-0" ABOVE FINISH GRADE AND PROVIDED
WITH LOCKSHIELD AND BACKFLOW PREVENTOR.
9. PROVIDE PIPING AS FOLLOWING:
HOT AND COLD WATER : COPPER TUBE TYPE "M" MIN.
INSTALLED WITH APPROVED
FITTINGS OR BEND.
SANITARY WASTE AND VENT: PVC SCHEDULE 40
AIR CONDITIONING CONDENSATE: PVC SCHEDULE 40
10. INSULATE HOT WATER PIPING WITH PREMOLDED GLASS FIBER PIPE INSULATION.
11. PROVIDE PLUMBING FIXTURES AS SELECTED BY OWNER.
12. PROVIDE ANTI SCALD VALVES 'a TUB / SHOWER COMBO.
13. SANITARY PITCH:
2" & LESS e 1/4" / FT
3" I/V / FT
4" 1/8" / FT
C.W.
SHUT-OFF
VALVE
C.W.
PLUMBING FIXTURES CONNECTION SCHEDULE
WASTE
GOLD WATE
HOT WATEiz
WATER CLOSET
3"
1/2"
-
LAVATORY
1 1/2"
1/2"
1/2"
BATHTUB / SHOWER
2"
1/2°
1/2"
SINK
1 1/2"
1/2"
1/2"
SIZE OF FIXTURE SUPPLY
T'T'fi E OF FIXTUiRE Oil DEVICE
BATH TUBS
DISHWASHER (DOMESTIC)
HOT WATER HEATERS
KITCHEN SINK
LAVATORY
SHOWER (SINGLE HEAD)
WATER CLOSET (TANK TYPE)
HOSE 51555
H.W.
ELECTRIC WTR. HTR.
50 GAL. STORAGE
22 GPH RECOVERY
E.F. 90
Fif I=S SIZE (INJ
1/2
3/4 MINIMUM
1/2
1/2
1/2
1/2
112
HEAT TRAP
T4P RELIEF DISCH.
/ VALVE
3/4" T4P
RELIEF LINE
WITH AIR GAP
OUTSIDE OF BLDG.
TERMINATE B.O.P.
& " A.F.G.
TYPICAL WATER HEATER DETAIL
N.T.S.
ENERGY COMPLIANCE MINIMUM REQUIREMENTS
COMPONENTS REQUIREMENTS
WINDOWS MINIMUM OF 0.34 CFM PER LINEAR FOOT OF OPERABLE SASH CRACK
( INCLUDES SLIDING GLASS DOOR).
EXTERIOR 4 MAXIMUM OF 0.5 CFM PER SQ. FT. OF DOOR AREA: SOLID CORE,
ADJACENT DOORS WOOD PANEL, INSULATED OR GLASS DOORS ONLY,
EXTERIOR JOINTS TO BE CAULKED, GASKETED, WEATHER-STRIPPED OR OTHERWISE
4 CRACKS SEALED.
SOLE $ TOP SOLE PLATES AND PENETRATIONS THROUGH TOP PLATES OF
PLATES EXTERIOR WALLS & RAISED WOOD FLOORS.
INFILTRATION INFILTRATION BARRIER MUST BE INSTALLED IN EXTERIOR WALLS
BARRIER 4 RAISED WOOD FLOORS.
INTERIOR ALL OPENINGS IN INTERIOR SURFACES OF CEILING AND
JOINTS/CRACKS EXTERIOR WALLS MUST BE SEALED.
EXHAUST FANS EXHAUST FANS VENTED TO UNCONDITIONED SPACE SHALL HAVE
DAMPERS, EXCEPT FOR COMBUSTION DEVICES WITH INTEGRAL
EXHAUST DUCTWORK.
HOT WATER INSULATION IS REQUIRED ONLY FOR RECIRCULATING SYSTEMS,
PIPES INCLUDING HEAT RECOVERY UNITS. IN SUCH CASES, PIPING,
HEAT LOSS SHALL BE LIMITED TO A MAXIMUM OF 1-1.5 BTUH
PER LINEAR FOOT OF PIPE.
SHOWER HEADS WATER FLOW MUST BE RESTRICTED TO NO MORE THAN 3 GALLONS
PER MINUTE AT 50 PSIG,
NORTH
PLUMBING PLAN
SCALE: 1 /4" = V-0"
-'SOUTH MAW
41NG DEPT.
�INQ SECilnu
REVISIONS
1� 08-09- 07
C.M.
F
V_�'y1l
ut�-K
XIVI' LOU
Al J
IL w
0 ❑
z
Y Q
❑y.m
Dm¢�wui
ao(L2Q0
Z W V C.)V
o � coz w
w
w m~ O a m
o=W<m�
(Lomu.o-.
�lv
»
ymm*—��
CCUL
40-- •
U r �
C J i
o-ph'
-s
N ,
CU k LL
O V N - M
Ln
Q ` CO�M r 1
• ^ o Ln
L.L! ^ -qr M co
CL O
O -
z
L
s
V v
C fy
W N -0
U oL -
O N
L �C3)
LA .
.� a Ln Q
UO O —
u M o, m
12 -, 00&-,m"
AS SHOWN