07-16R-003PLUMBING NOTES I. VERIFY ALL SPACE CONDITIONS, DIMENSIONS, DIMENSIONS AND PIPE SIZES AT PROJECT SITE PRIOR TO FABRICATION ANS INSTALLATION OF MATERIALS AND EQUIPMENT, 2. COORDINATE WORK WITH OTHER TRADES. 3. PLUMBING CONTRACTOR SHALL PAY ALL FEES, INSPECTION AND CONNECTION CHARGES REQUIRED. 4. SUBMIT SHOP DRAWINGS TO ARCHITECT FOR APPROVAL OF ALL EQUIPMENT, MATERIALS AND LAYOUT PRIOR TO INSTALLATION. 5. PLUMBING CONTRACTOR SHALL GUARANTEE ALL WORK FREE OF DEFECTS IN MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM DATE OF ACCEPTANCE. 6. PROVIDE SHUT OFF VALVE FOR EACH FIXTURE AND Alit CHAMBERS WHERE SHOWN ON DRAWINGS AND WHERE REQUIRED FOR PROPER PERFORMANCE OF THE SYSTEM. 7. PROVIDE DIELECTRIC FITTINGS TO CONNECT PIPING OR EQUIPMENT OF DISSIMILAR METALS. 8. HOSE BIBBS SHALL BE INSTALLED 2'-0" ABOVE FINISH GRADE AND PROVIDED WITH LOCKSHIELD AND BACKFLOW PREVENTOR. 9. PROVIDE PIPING AS FOLLOWING: HOT AND COLD WATER : COPPER TUBE TYPE "M" MIN. INSTALLED WITH APPROVED FITTINGS OR BEND. SANITARY WASTE AND VENT: PVC SCHEDULE 40 AIR CONDITIONING CONDENSATE: PVC SCHEDULE 40 10. INSULATE HOT WATER PIPING WITH PREMOLDED GLASS FIBER PIPE INSULATION. 11. PROVIDE PLUMBING FIXTURES AS SELECTED BY OWNER. 12. PROVIDE ANTI SCALD VALVES 'a TUB / SHOWER COMBO. 13. SANITARY PITCH: 2" & LESS e 1/4" / FT 3" I/V / FT 4" 1/8" / FT C.W. SHUT-OFF VALVE C.W. PLUMBING FIXTURES CONNECTION SCHEDULE WASTE GOLD WATE HOT WATEiz WATER CLOSET 3" 1/2" - LAVATORY 1 1/2" 1/2" 1/2" BATHTUB / SHOWER 2" 1/2° 1/2" SINK 1 1/2" 1/2" 1/2" SIZE OF FIXTURE SUPPLY T'T'fi E OF FIXTUiRE Oil DEVICE BATH TUBS DISHWASHER (DOMESTIC) HOT WATER HEATERS KITCHEN SINK LAVATORY SHOWER (SINGLE HEAD) WATER CLOSET (TANK TYPE) HOSE 51555 H.W. ELECTRIC WTR. HTR. 50 GAL. STORAGE 22 GPH RECOVERY E.F. 90 Fif I=S SIZE (INJ 1/2 3/4 MINIMUM 1/2 1/2 1/2 1/2 112 HEAT TRAP T4P RELIEF DISCH. / VALVE 3/4" T4P RELIEF LINE WITH AIR GAP OUTSIDE OF BLDG. TERMINATE B.O.P. & " A.F.G. TYPICAL WATER HEATER DETAIL N.T.S. ENERGY COMPLIANCE MINIMUM REQUIREMENTS COMPONENTS REQUIREMENTS WINDOWS MINIMUM OF 0.34 CFM PER LINEAR FOOT OF OPERABLE SASH CRACK ( INCLUDES SLIDING GLASS DOOR). EXTERIOR 4 MAXIMUM OF 0.5 CFM PER SQ. FT. OF DOOR AREA: SOLID CORE, ADJACENT DOORS WOOD PANEL, INSULATED OR GLASS DOORS ONLY, EXTERIOR JOINTS TO BE CAULKED, GASKETED, WEATHER-STRIPPED OR OTHERWISE 4 CRACKS SEALED. SOLE $ TOP SOLE PLATES AND PENETRATIONS THROUGH TOP PLATES OF PLATES EXTERIOR WALLS & RAISED WOOD FLOORS. INFILTRATION INFILTRATION BARRIER MUST BE INSTALLED IN EXTERIOR WALLS BARRIER 4 RAISED WOOD FLOORS. INTERIOR ALL OPENINGS IN INTERIOR SURFACES OF CEILING AND JOINTS/CRACKS EXTERIOR WALLS MUST BE SEALED. EXHAUST FANS EXHAUST FANS VENTED TO UNCONDITIONED SPACE SHALL HAVE DAMPERS, EXCEPT FOR COMBUSTION DEVICES WITH INTEGRAL EXHAUST DUCTWORK. HOT WATER INSULATION IS REQUIRED ONLY FOR RECIRCULATING SYSTEMS, PIPES INCLUDING HEAT RECOVERY UNITS. IN SUCH CASES, PIPING, HEAT LOSS SHALL BE LIMITED TO A MAXIMUM OF 1-1.5 BTUH PER LINEAR FOOT OF PIPE. SHOWER HEADS WATER FLOW MUST BE RESTRICTED TO NO MORE THAN 3 GALLONS PER MINUTE AT 50 PSIG, NORTH PLUMBING PLAN SCALE: 1 /4" = V-0" -'SOUTH MAW 41NG DEPT. �INQ SECilnu REVISIONS 1� 08-09- 07 C.M. F V_�'y1l ut�-K XIVI' LOU Al J IL w 0 ❑ z Y Q ❑y.m Dm¢�wui ao(L2Q0 Z W V C.)V o � coz w w w m~ O a m o=W<m� (Lomu.o-. �lv » ymm*—�� CCUL 40-- • U r � C J i o-ph' -s N , CU k LL O V N - M Ln Q ` CO�M r 1 • ^ o Ln L.L! ^ -qr M co CL O O - z L s V v C fy W N -0 U oL - O N L �C3) LA . .� a Ln Q UO O — u M o, m 12 -, 00&-,m" AS SHOWN