07-16R-001�-j LEGEND -�- INC. FIXTURE W/ A19 - 15OW REFLECTOR 1 EXIST. INCANDESCENT FIXTURE s 10 INCANDESCENT FIXTURE WALL MOUNTED K ' EXIST. INCANDESCENT FIXTURE WALL MOUNTED O RECESSED LIGHT EXHAUST FAN PI PRE WIRED TELEPHONE OUTLET EXIST. PRE WIRED TELEPHONE OUTLET RECEPTACLE DUPLEX, 15A - 125V. EXIST. RECEPTACLE DUPLEX i' EXISTING RECEPTACLE 120/240 V Q SMOKE DETECTOR TOGGLE SWITCH, SINGLE POLE EXIST. TOGGLE SWITCH, SINGLE POLE 0 EXIST. ELECTRICAL PANEL - SEE SCHEDULE HOMERUN TO PANEL - BOARD LETTER AND NUMBER INDICATE PANEL AND CIRCUIT (INCL. GROUND AS PER NEC) HATCH INDICATES No. OF WIRES, G - INDICATES GROUND ELECTRICAL NOTES 1. DO NOT SCALE DRAWINGS. REFER TO ARCHITECTURAL PLANS AND ELEVATIONS FOR EXACT LOCATIONS OF ALL EQUIPMENT AND CONFIRM WITH OWNER REPRESENTATIVE. 2. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE N.E.C. AND SHALL COMPLY WITH ALL LOCAL RULES AND ORDINANCES. 3. UNLESS OTHERWISE NOTES, MINIMUM WIRE SIZE SHALL BE NO. 12 AWG. AND ALL CONDUCTORS SHALL BE GOOPEiR WITH TW INSULATION FOR SIZES NO. (o AND SMALLER. CONDUCTORS LARGER THAN NO. 6 SHALL HAVE TYPE THW INSULATION. ALL CONDUCTORS NO. 10 AND SMALLER MAY BE SOLID. ALL THOSE NO. 8 AND LARGER SHALL BE STRANDED. EQUIVALENT ALUMINUM CONDUCTORS CAN BE USED SUB FEEDERS NO. G OR LARGER, IF APPROVED BY LOCAL REGULATIONS. CONTRACTORS TO VERIFY. 4. ALL RACEWAYS AND PIPES PLACED IN OR THRU ANY CONCRETE SLAB SHALL BE SPACED A MINIMUM OF 3 DIAMETERS OF THE LARGEST CONDUIT OR PIPE OF ANY OTHER SERVICE. S. ALL RACEWAYS UNDERGROUND AND/OR LARGER THAN 2 INCHES IN DIAMETER SHALL BE GALVANIZED RIGID STEEL. PVC PIPE SCH. 40 WILL BE ACCtND TABLE, IF APPROVEDBY LOCAL REGULATIONS. CONTRACTOR TO VERIFY. 6. OUTLET BOXESSHALL BE PRESSED STEEL IN DRY LOCATIONS CAST ALLOY WITH THREADED HUBS IN WET OR DAMP LOCATIONS. 7. DISCONNECT SWITCHES SHALL BE QUICK MAKE, QUICK BREAK, IN NEMA 1 OR 3R ENCLOSURE, AS REQUIRED BY EXPOSURE. 8. ALL MATERIAL SHALL BE NEW AND SHALL BEAR UNDERWRITERS AND UNION LABELS WHERE APPLICABLE. 9. ALL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR IN A WORKMAN LIKE MANNER. THE COMPLETED SYSTEM SHALL BE FULLY OPERATIVE AND ACCEPTANCE BY ENG./ARCH, MUST BE A CONDITION OF THE CONTRACT. ELECTRICIAN SHALL INDICATE ON ELECTRICAL PANEL BOARD AREAS SERVED BY EACH C.B. 10. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH PROGRESS OF CONSTRUCTION. 11. CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE OF DEFECT FOR A PERIOD OF NO LESS THAN ONE YEAR FROM THE DATE OF ACCEPTANCE. ELECTRICAL FLOOD CRITERIA 1. ELECTRICAL OUTLETS (RECEPTACLES AND LIGHTING) BELOW BASE FLOOD ELEVATION SHALL BE INSTALLED AT THE HIGHEST PERMITTED ELEVATION AND SHALL BE INSTALLED WITH SEPARATE INDEPENDENT CIRCUITS FROM THOSE IN THE HABITABLE AREAS. 2. NO APPLIANCE OR APPLIANCE OUTLETS SHALL BE INSTALLED BELOW BASE FLOOD ELEVATION. 3. A/G COMPRESSORS SHALL BE INSTALLED ABOVE BASE FLOOD ELEVATION. 4. MAIN CIRCUIT BREAKER PANELS SHALL BE LOCATED ABOVE BASE FLOOD ELEVATION 5. COORDINATE WITH FLORIDA POWER 4 LIGHT COMPANY TO LOCATE THE ELECTRICAL METER TO COMPLY WITH FEDERAL EMERGENCY MANAGEMENT AGENCY REQUIREMENTS. SOUAR=_ D OR AFP. EO. 240 12011111 PANEL ; 1� 3Lu 200 AMPS CKT. l l0. &EIRVIIIG WIRE CONDUIT TOT. 1GV.4 POLES AMPS CKT. NO, SERVING WIRE CONDUIT TOT. <V4 POLES AMPS I LU.-1TErR NEATER 10 1/2" 4,500 2 30 2 BEDROOM "1 12 1/2 1.5 1 20 � BEDROOM #2 12 1/2 1.5 1 20 5 - 12 1/2 1.5 1 20 1 ro LIG-ITINCa 12 1/2 0.ro I 15 1 SM-. LL .4FFL. 12 1/2 1.5 1 20 a LIG44TING 12 1/2 0.ro 1 15 CU "1 a 3/4 1,200 2 40 10 LIVING RM, 12 I/2 1.5 1 20 I1 12 REFRIGERATOR 12 1/2 1.5 1 20 13 RANGE ro 1 10 2 50 14 AHU"I I " 1(5,000 2 60 15 16 11 DINING- ROOM 12 1/2 1.5 1 20 la DRYER 10 3/4 5.0 2 40 19 DINING ROOM 12 1/2 15 I 20 20 -'I LUASHER 12 1/2 1,5 1 20 22 23 FAMILY ROOM 12 1/2 15 1 20 24 FAMILY ROOM 12 1/2 1.5 1 20 23 LIGHTS 12 1/2 0.6 1 1$ 1 26 SMALL AF'PL. 12 1/2 15 1 20 21 KITC14EN 12 1/2 15 1 20 28 MASTER 13ATH 12 1/2 15 1 20 29 MASTER BED 12 1/2 15 1 20 30 GFI 12 1/2 15 1 20 31 W14IRLPOOL 10 3/4' 2,WO 2 30 32 DISHWASHER 12 1/2 15 1 20 33 34 LIGHTS 12 1/2 0.6 1 15 35 GU n 8 3/4 1;00 2 40 36 AHu Q 6 is ISOM 2 60 31 38 39 SFACE 40 SPACE I IOTE : ROME/ MAY BE USED IN LIEU OF CONDUIT CIRCUIT ARC FAULT PROTECTION REQUIRED IN ALL BEDROOM CIRCUITS ELECTRICAL LOAD CALCULATIONS LIGHTS S RECEPTACLES (3W X 2,14g S.F.) SMALL APPLIANCES REFRIGERATOR DISH WASHER RANGE & OVEN WATER HEATER WASHER DRYER FIRST 10,000 W. a 100% REMAINING 26,94-1 W '@ 40% A/C LOAD X 2 z KITCHEN OR BATHROOM L IGHT (INTERCONN CTED) I SMOKE DETECTOR 120 V. LINE SIDE SWITCH LEG OF SWITCH SWITCH PHASE CONDUCTOR SMOKE DETECTOR CONNECTION DETAIL N.T.S. SMOKE DETECTORS SHALL BE HARD WIRED (110 VOLT TYPE) TO A NON-SWITCHABLE KITCHEN OR BATHROOM LIGHTING CIRCUIT, WITH BATTERY BACK UP AND SHALL NOT BE CONNECTED ONTO THE LOAD SIDE OF A GROUND FAULT CIRCUIT INTERRUPTER EXISTING OVERHEAD ELECT. SERVICE 3 -#3/0 CU. THW IN 2" C ELEC MTR. 3 -#3/0 CU. THW IN 2" C 1 0 3 -#3/0 CU. THW IN 2" C 2 200 L-t 200 DISC. SW. --1 #4 TW CU, IN 3/4" C TO CWP 200 AMP. PANEL W/ MAIN CIRC. BRKR. W/ 40 - IP SPACES L (2) 10'-0" DEEP GROUNDING RODS 5/8" DIAMETER SPACED ro FT. APART 4 BOND TO FOUNDATION EXISTING ELECTRICAL RISER DIAGRAM N.T.S. 8,241 WATTS (EXIST.) V/ V � � / �'� "� V REF � 30 3,000 WATTS , GFI 12 (E) �. 23 3W 23 23 23 2� I 1,500 WATTS ® i 1,200 WATTS - 3 R R 34 2 (E) � 2) / CxFI 12,000 WATTS 30 (E) (E) Y(E) (E) >; NOOK 4,500 WATTS UTILITY 18, 2m R R 1,500 WATTS BEDROOM #1 (E) BEDROOM #2 - 34 (EXIST.) (EXIST.) PA CRY5,000 WATTS 22(E) WH1,3 CiTY OF SOUTH MIAMI SUBTOTAL = 36,94l WATTS 1 BUILDING DEPT. ELECTRICAL SECTION TOTAL DEMAND LOAD = 30,17g WATTS % 240 V = 128 AMPS 10,000 WATTS 10,119 WATTS 10,000 WATTS 30,1-i9 WATTS NORTH ELECTRICAL PLAN SCALE: 1 /4" = l'-0" REVISIONS BY -:, 06-1 1-2007 C.M. 2Q 08-09-2007 C.M. w c� 0 ~ w Y Q Z QWOj a 0 a O o Z w O V V O w co w 0 0 w cnMt-zom J 1wi = j U ~ Lu m � U a CIE 0 J �. 0 c Q 0. 0 w 0 J \� e 4_ u c au 4) a) (U � L > +r N Q ca X W c� N rn -a rn O Co 0 to rn N v1 5 Ln •- 0 Q L CO M W h0LAM Nd-mco r- M i p M Z o0 �n N Q� L Co s Cu V cu Ln U a) •C 0 rn + a C � W N UN 0 LO M J 000c)LL s c `^ Q d1 U0 0 - U M Ol m DRAWN G.C. CHECMED i C. M. DATE 12-13-2006 SCALE AS SHOWN_ JOB IJO 22-2006 I SHEET E- 1 7 OF 7 SHEETS