09-49-077SLOPE PVC PIPE PER PLANS HEX WASHERHEAD SELF PIERCING SCREW SIZE 98,1' LONG, TYP. 20 GA. MIN. GALV. STRAP, ANCHOR TO ROOF SUPPORT i / SEE PLANS FOR SIZE. ATTACH TO ROOF WITH 'TAM -PRO 80 V PLASTIC ROOF CEMENT OR EQUAL (MIAMI-DARE COUNTY APPROVED) '1.5' PIPESTAND MODEL FABRICATED BY MIRO INDUSTRIES SET PER TABLE (SEE NO ) 1.5' RIGID POLYCARBONATE RESIN WITH ---- CARBON BLACK ADD. FOR W C i P VIDE NO. AS REQ'0 TO MAINTAIN SLOPE 3 CLEARANCE ROOF (SEE ARCH.) NOTE: CONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS. ACCOMMODATE HEIGHT OF SUPPORT ' > IN ORDER TO COMPLY WITH AIR GAP REQUIREMENT AT ROOF DRAIN. CONDENSATE PIPE I TERMINATION SHALL BE TABOVE ROOF DRAIN STRAINER PROVIDE SUPPORTS AS PER TABLE 305.4 OF F.B.C. 2004 - MECHANICAL ROOF PIPING SUPPORT DETAIL NOT TO SCALD PROVIDE ROUND SECURED NICKEL BRONZE ADJUSTABLE TOP WTTH'CO' CAST IN COVER PROVIDE CLEANOUT TOP WITH VARIATION$ SUITABLE FOR FLOOR COVERING (CARPET MARKER, RECESSED FOR TILE, SCORIATED FOR UNFINISHED FLOORS} PROVIDE BRONZE PLUG IN CAST IRON BODY. MEMBRANE CLAMP '1 /-- FLOOR SLAB ON GRADE SAME SIZE AS SEWER UP TO 61 MAXIMUM. AS REQUIRED FOR DEPTH OF SEWER HUB AND SPIGOT LONG SWEEP ELBOW AT CAST IRON PIPE END OR TURN OF RUN. BELOW FLOOR COMBINATION WYE AND SANITARY OR STORM EIGHTH BEND IN RUN. VD SEWER LINE ENTER TOP OF PIPE. - - - 3 <- DIRECTION 4- f OF FLOW LOCATE AT BUILDING EXIT, AT ENDS OF RUNS, AT TURNS OF PIPE GREATER THAN 45 DEGREES, AT 5V INTERVALS ON STRAIGHT RUNS, AND WHERE SHOWN ON PLANS. PROVIDE BACKFILL PER ARCHITECTURAL SPECIFICATIONS. LOCATE CLEANOUTS WHERE THERE IS 18' CLEAR AROUND. CONSULT LOCAL CODES FOR OTHER FCO REQUIREMENTS. FLOOR CLEANOUT DETAIL NOT TO SCALF" NOTES: I. ALLOW SUFFICIENT SPACE BELOW DRAIN PAN FOR TRAP 2, PITCH DRAIN FOR PROPER RUNOFF. 3. MANUALLY PRIME FILL TRAP BEFORE START-UP TO FORM INITIAL DRAIN SEAL 4. SUPPORT LENGTHY DRAIN LINES TO PREVENT SAO AND CONDENSATE OVERFLOW. AIC UNIT CLEANOUT CAP (TYP.) PITCH DRAIN PAN DRAIN PIPE TO MATCH DRAIN OUTLET SIZE. THIS STANDARD DETAIL MUST BE REVIEWED AND SITE ADAPTED BY CONTRACTOR PRIOR TO USE FOR FINAL EQUIPMENT. VENT LINE PERFORATED CAP PPITCH ^ 0 u (a) THIS DIMENSION IN INCHES MUST BE EQUAL TO THE MAXIMUM FAN SUCTION (NEGATIVE) STATIC PRESSURE IN INCHES WG (LATH DIRTY FILTERS, COILS, AND MAXIMUM AIR FLOW) + 1' W.G. (D) THIS DIMENSION IN INCHES MUST BE EQUAL TO MIN.112 OF THE (a) ABOVE (c) EQUALS (a) + (b) + PIPE DIA. + + INSULATION DRAW THRU UNIT CONDENSATE TRAP NOT 10 SCALP PROVIDE TEST TEE WITH SCREWED COUNTER- SUNK ASS PLASTIC PLUG: TAPERED -THREAD WITH TFE JOINT COMPOUND. WHERE CLEANOUT TEE IS CONCEALED IN A CHASE OR PARTITION, PROVIDE AROUND 18 GAUGE STAINLESS STEEL COVER WITH BEVELED EDGES AND FLATHEAD MACHINE SCREW. - CONCRETE FLOOR SLAB MOTE: PROVIDE WCO WHERE SHOWN ON PLAN, AND ON SANITARY WASTE BRANCHES NOT SERVED WITH A FLOOR CLEANOUT: LOCATE ABOVE FIXTURE FLOOD RIM WITHIN 4' OF FLOOR CONSULT LOCAL CODES FOR OTHER WCO REQUIREMENTS. COLUMN OR PARTITION AS SHOWN ON FLOOR PLAN CLEANOUT FACE SHALL BE WITHIN 4' OF WALL SURFACE PROVIDE PIPE EXTENSION IF REQUIRED, WALL CLEANOUT DETAIL NOT TO SCALE COLD WATER SUPPLY TO WATER HEATER MIN. 4 GAL EXPANSION TANK HEAT TRAP HOT WATER TO FIXTURES AS SHOWN ON PLANS a PROVIDE A 210'F PROVIDE FULL PORT BALL i a TEMPERATURE SHUT-OFF VALVES PRESSURE RELIEF VALVE PROVIDE PIPE WITH TEST LEVER UNIONS, DIELECTRIC SIZED WITH AGA/CGA IF REQUIRED FOR TEMPERATURE STEAM DISSIMI AR METALS RATING 1D%OVER HEATER INPUT. THERMOSTATAND PROVIDEAHARD PRESSURE REGU- COPPER RELIEF LATOR FURNISHED VALVE DISCHARGE WITH WATER HEATER LINE FULL SIZE OFVALVE OUTLET F TO INDIRECT WASTE IN SAME ROOM WITH AVISIBLE AIR GAP PROVIDE A DRAIN PAN, RUN OVERFLOW LINE TO NEARESTAPPROVED INDIRECT WASTE DRAIN VALVE BY HEATER MANUFACT DRAIN PAN WITH MINIMUM 2' HIGH SIDES PIPING ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FIELD CONDITIONS. REFER TO ISOMETRIC RISER FOR PIPE SIZES. SET HEATER THERMOSTAT AT 120' F. WATER HEATER DETAIL NO'L" I'O SCALE PLUMBING NOTES 1. ALL WORKMANSHIP AND MATERIALS SHALL BE I N STRICT ACCORDANCE WITH FBC 2004, APPLICABLE LOCAL CODES, RULES AND ORDINANCES. 2, PLUMBING CONTRACTOR SHALL VISIT THE JOB SITE AND THOROUGHLY FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITIONS. 3. ALL MATERIALS SHALL BE NEW. 4. ALL WORK SHALL BE PERFORMED BY LICENSED PLUMBING CONTRACTOR IN A FIRST CLASS WORKMANLIKE MANNER THE COMPLETED SYSTEM SHALL BE FULLY OPERATIVE. ALL EXCAVATION AND BACKFILL AS REQUIRED FOR THIS PHASE OF CONSTRUCTION SHALL BE A PART OF THIS CONTRACT. 5, REQUIRED INSURANCE SHALL BE PROVIDED BY THE PLUMBING CONTRACTOR FOR PROTECTION AGAINST PUBLIC LIASIL TY AND PROPERTY DAMAGE FOR THE DURATION OF THE WORK, 6. PLUMBING CONTRACTOR SHALL. SECURE AND PAY FOR ALL PERMITS, FEES, INSPECTION AND TESTS, PLUMBING CONTRACTOR TO OBTAIN PERMIT AND APPROVED SUBMITTALS PRIOR TO BEGINNING WORK OR ORDERING EQUIPMENT, PLUMBING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS OF HIS WORK BY REGULATORY AUTHORITIES. 7. DRAWINGS ARE DIAGRAMMATIC. DO NOT SCALE FOR THE EXACT LOCATION OF FIXTURES, PIPING, EQUIPMENT, ETC, 8. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE PROGRESS OF CONSTRUCTION, REPORT ANY DISCREPANCY TO ENGINEERIARCHITECT PRIOR TO BEGINNING CONSTRUCTION. 9. VERIFY LOCATION, SIZE, DIRECTION OF FLOW AND INVERTS OF ALL EXISTING UTILITIES PRIOR TO BEGINNING OF CONSTRUCTION. ADVISE ENGINEER OF ANY DISCREPANCIES, 10, WATER DISTRIBUTION PIPING ABOVE AND BELOW GROUND SHALL BE TYPE'V COPPER COORDINATE WITH LOCAL JURISDICTION FOR ADDITIONAL REQUIREMENTS, PROVIDE ALTERNATE FOR CPVC PIPING EQUAL. TO BFGCODRICH 'FLOWGUARD GOLD' FOR WATER KNOWN OR DETERMINED TO HAVE ACIDIC CHARACTERISTICS, CONTRACTOR SHALL PERFORM A WATER TEST TO DETERMINE WATER CHEMISTRY PRIOR TO ANY WORK OR PIPING INSTALLATION AND SHALL SUBMIT TEST RESULT'S TO ENGINEER FOR REVIEW AND APPROVAL I I- SOiI, WASTE, VENT AND RAINWATER PIPING SHALL BE CAST IRON OR FVC, WHERE CODE ALLOWS, PVC MAY NOT BE USED THRU RATED ASSEMBLIES OR IN PLENUMS. 12. ALL FIXTURES MUST BE PROVIDED WITH READILY ACCESSIBLE STOPS AND APPROPRIATELY MARKED ACCESS PANELS. COORDINATE LOCATIONS WITH GENERAL CONTRACTOR PRIOR TO INSTALLATION. 13. FURNISH AND INSTALL APPROVED WATER HAMMER ARRESTORS FOR ALL (GROUP) PLUMBING FIXTURES, SIZED AND LOCATED PER MANUF. S INSTALLATION INSTRUCTIONS AND WH4'DI 201, 14. DIELECTRIC COUPLINGS ARE REQUIRED BETWEEN ALL DISSIMILAR METAL IN PIPING AND EQUIPMENT CONNECTIONS. 15. ISOLATE COPPER PIPE FROM HANGER OR SUPPORTS WITH ISOLATOR PADS OR MATERIAL, 10. ALL FIRE RATED FLOOR AND WALL PENETRATIONS SHALL BE PROPERLY PROTECTED FROM FIRE, SMOKE AND WATER PENETRATION BY FILLING VOIDS BETWEEN PIPE AND WALUFLOOR SLEEVES WITH FIRE RATED FOAM, TO ACHIEVE THE SAME RATING AS WAILS OR FLOORS AS PART OF THE PLUMBER'S WORK. 17. PLUMBING CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE FROM DEFECTS FOR A PERIOD OF NOT LESS THAN ONE (1) YEAR FROM DATE OF ACCEPTANCE BY OWNER CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL CHARGE AND SHALL INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION WHICH MAY HAVE BEEN DAMAGED. 18. PROVIDE ACCESS PANELS FOR ALL CONCEALED VALVES AND ALL WATER HAMMER ARRESTORS. ACCESS PANELS IN RATED WALLS MUST MAINTAIN THE SAME RATING AND MUST MATCH THE FINISH OF THE WALL IN WHICH IT IS INSTALLED. 19. PROVIDE COMBINATION COVER PLATE AND CLEANOUT PLUG OR ACCESS PANEL FOR ALL WALL CLEANOUTS FINISH TO MATCH FIXTURE TRIM. 20. NO COMBUSTIBLE MATERIAL TO BE USED IN MECHANICAL ROOMS OR IN CEILING SPACES WHERE USED AS RETURN AIR PLENUMS. 21. NO WATER, SANITARY OR DRAINAGE PIPING PERMITTED IN ELECTRICAL OR ELEVATOR EQUIPMENT ROOMS. 22. ALL CONTROL VALVES SHALL. BE TAGGED AND MARKED. A REPRODUCIBLE DIAGRAM LOCATING ALL VALVES SHALL BE PROVIDED FOR OWNERIOPERATOR 23. ALL CONDENSATE DRAIN PIPING SHALL BE TYPE'V COPPER WITH ARMAFLEX INSULATION PER F.B.C. 2004 CHAPTER 13 TABLE 411.1 WHERE USED IN A RETURN AIR PLENUM. PVC PIPING WITH ARMAFLEX INSULATION MAY BE USED IN LOCATIONS WHERE ALLOWED BY LOCAL CODES, SEE PLUMBING DRAWINGS FOR SIZE AND LOCATION OF PIPING. 24, CONDENSATE LINES SHALL NOT DRAIN ON THE ROOFING SYSTEM OR ANY OF ITS COMPONENTS AND CONDENSATE LINES NEED NOT COMPLY WITH MIN. CLEARANCE REQUIREMENTS PER F.B.C. BUILDING 2004, PAR.1522.3.5 25. PROVIDE ANGLE STOPS ON ALL WATER SERVICE LINES TO FIXTURES FOR INDIVIDUAL SHUT-OFF. 26. WATER PIPING INSULATION SHALL BE ARMAFLEX OR EQUAL INSTALLED IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS FOR ALL HOT WATER PIPING. WHERE DOMESTIC WATER TEMPERATURES CAN CAUSE SWEATING ALL COLD WATER PIPING SHALL BE INSULATED WITH ARMAFLEX INSULATION, THICKNESS AS PER F.B.C. 20% CHAPTER 13 TABLE 411.1 27. STUDOR MINVMAXI AIR ADMITTANCE VALVES MAY BE USED AS AN ALTERNATE TO VENT PIPING THRU ROOF WHERE ACCEPTABLE BY THE PLUMBING OFFICIAL AND LOCAL CODES. INSTALLATION SHALL BE AS PER MANUFACTURER'S RECOMMENDATIONS, 28. ALL HORIZONTAL RAINWATER PIPING THAT RECEIVES CONDENSATE DISCHARGE FROM AIR CONDITIONING EQUIPMENT SHALL BE INSULATED WITH 1' THK. ARMAREX SLOPE OF HORIZONTAL STORM DRAINAGE PIPING SHALL BE 1/8' PER FOOT, UNLESS OTHERWISE NOTED, WATER HAMMER ARRESTER SPECS. P.D.I. UNITS F.U. RATING MODEL No. MANUFACTURER CONNECTIONS A 1-11 e52-A SIOUXCHIEF 1/2" B 1 12 - 32 e53 - B SIOUX CHIEF 3/4' NOTE: 1. SIOUX CHIEF WATER HAMMER ARRESTORS ARE APPROVED FOR INSTALLATION WITHOUT ACCESS DOOR REQUIRED. CONFORMS TO ANSVASSE 1010 STANDARDS. WALL HUNG FIXTURES SHALL BE SUPPORTED AS PER FBC 2517.5.1.1 Steel studs supporting wall hung plumbing fixtures shall be doubled or not or less than 20 gauge with a minlmun eftctive moment of inertia equal to 0.864 Ind (3600). PLUMBING LEGEND CO CLEAN OUT 5 SANITARY SEWER PIPING FD FLOOR DRAIN S- - - - -S VENT PIPING - - CW DOMESTIC COLD WATER DOMESTIC COLD WATER PIPING - - HW DOMESTIC HOT WATER HOT WATER PIPING (IIII-)- HB HOSE BIBB S- CD -S CONDENSATE PIPING ' - VTR VENT THRU ROOF S- SD -3 �• = - • - . - - " STORM DRAIN PIPING DG GATE VALVE S--O-; PIPE RISE UP Q� WATER HAMMER ARRESTER (PDT No.) S-?-S PIPE DOWN OR DROP FD FLOOR DRAIN C- CAPPED END OF PIPE ? ` -� CLEAN OUT '� -- POINT OF CONNECTION P-TRAP A ' PLUMBING FIXTURE SCHEDULE LAV LAVATORY TO BE BY OWNERIARCHMECT. HLAV HANDICAP LAVATORY TO BE BY OWNER/ARCHITECT. WC WATER CLOSET TO BE BY OWNER/ARCHITECT, HWC HANDICAP WATER CLOSET TO BE BY OWNER/ARCHITECT, UR URINAL TO BE BY OWNER/ARCHITECT. HDPIDF DRINKING FOUNTAIN TO BE BY OWNER/ARCHTTECT, MOP SINK MOP SINK TO BE BY OWNERIARCHITECT. SK SINK TO BE BY OWNERIARCHITECT. SK•2 2-COMP, SINK TO BE BY OWNERIARCHITECT, SK-3 31COMP, SINK TO BE BY OWNER/ARCHRECT, LSK LAB SINK TO BE BY OWNER/ARCHITECT. ES EMERGENCY SHOWER TO BE BY OWNER/ARCHITECT, EW EYEWASH TO BE BY OWNER/ARCHITECT. HB HOSE BIBB TO BE WOODFORD MODEL B24 WITH SOX, 3W STRAIGHT INLET CONNECTION, ANTI -SIPHON. GT GREASE TRAP TO BE WADE MODEL 5120. E1NC WATER HEATER SHALT. BE 50 GAL, ELECTRIC 20W, 3 PHASE, 9.0 KW. LOCHINVAR STANDARD HI -POWER MODEL HST09•50, GENERAL NOTES: (1) - FIXTURES SHALL BE AS SHOWN OR EQUAL (2) - ALL FIXTURES SHALL COMPLY WITH TABLE 604.4 OF FBC 20D4, (3) - ALL FIXTURE TRIM PACKAGES INCLUDING BUT NOT LIMITED TO TRAP, ANGLE STOP, FLUSH VALVE, SUPPLY TUBES, AND CLEANOUT COVER PLATES SHALL BE OF THE SAME FINISH AS THE ABOVE SPECIFIED FAUCET AND PER ARCHITECTURAL FINISH SCHEDULE (4) - ALL FIXTURES SHALT. BE ROUGHED IN PER MANUFACTURER CUT SHEET TO MAINTAIN UNIFORMITY. SLOPE OF HORIZONTAL DRAINAGE PIPE AS PER TABLE 704.1 - FBC PLUMBING SIZE (INCHES) MINIMUM SLOPE (INCH PER FOOT) 21/2 OR LESS 0 1/4' / FT 3 TO 8 Q Its' / FT 8 OR LARGER ®1/16" / FT MAXIMUM FLOW RATES AND CONSUMPTION FOR PLUMBING FIXTURES AND FIXTURE FITTINGS (AS PER TABLE 604.4 - FBC PLUMBING) PLUMBING FIXTURE OR FIXTURE FITTING MAXIMUM FLOW RATE LAVATORY, PRIVATE 2.2 GPM AT 60 PSI WATER CLOSET 1.6 GALLONS PER FLUSHING CYCLE r% !KM ALEJANDROtRrOS R.A. Ichit8lctS ;A:olandra Regis R.A. 0011702 -18501 Pines Blvd., Suite 107 - - Pembroke Pines FL 33029� er. (954) 342-7122 Fax: (954) -142 7190 w e-m9ll: rernosbIc g@aol.co q SOMERSET HARTER�-,- SCHOOL. L South Mianif k'_' . -5876 SW 68th Street # d' South Miami, FL, 33143 4 lC' L CONSULTANTS: . Jt NETH-ARDILA architect ALBERTO CHINCHILLA architect ALEJANDRO CABAL -CABAL architect MARCEL ADRIAN PEREZ architect ASWI Pines Blvd., Suite 107 Pembroke Pines FL 33029 STRUCTURAL ENG.: EDUARDO GONZALEZ P.E. INC. Structural Engineers State of Florida CA No. 6188 J. Eduardo Gonzdlez P.E. -717 Ponce de Leon Blvd., Suite 335 Coral Gables FL 33134 Tel: (308) 445 5100 Fax: (305) 4456644 e-mail: eddygon@bellsouth.net M.E.P. ENG.: INGEMEL SA LLC. ENGINEERING COMPANY STATE OF FLORIDA CA No. 9113 Pedro Arias P.E. 63813 PaWcfs Moral" P.E 63818 -20871 Johnson Street, Suite 115 Pembroke Pines FL 33029 USA Tel: (954) 318 2264 Fax: (954) 450 721 a e-mall: pedroa@ingemel.com pmoreles@:rpemel.com CIVIL ENG.: Consulting Engineering & Science, Inc. t Nelson H, Ortlz P.E. 575W -10700 North Kendall Drive Suite 400 Miami FL 33178 Tel: (305) 378 5555 Fax (305) 279 4553 e-mail: nortiz@CESMIAMI.com LANDSCAPE ARCH.: M. L. A. GROUP INC. Scott McClure RLA 6666695 -690 NE 13th Street Suite 105 Fort Lauderdale FL 33304 Tel: (954) 783 4071 Fax: (954) 487 I WS e-mall: mlegroupinc@yahoo.com SEAL: " P.E.63818��, REVISIONS. - Project No: USCG-1 Model File: Drawn by: A.G. Approved by: 0.M.M. ;$ Date: 08/08/08 Scale: As S R own Copyright Sheet Title PLUMBING . - NOTES, NOTES, DETAILS, AND SCHERULES Sheet Number fr �` L SOMERSET SOUTI*M]1AMI