09-49-069n O FIRE PROTECTION GENERAL NOTES 1. FIRE PROTECTION SYSTEM TO COMPLY WITH NFPA 13, AND ALL APPLICABLE.STATE AND LOCAL CODES. 2. ADHERE TO AND OBTAIN ALL PERMITS, LICENSES AND GOVERNMENT REQUIREMENTS. 3. FINAL INSPECTION AND APPROVAL BY LOCAL FIRE DEPARTMENT, AND ARCHITECT/ENGINEER. 5. CUTTING OF STRUCTURAL AND/OR ARCHITECTURAL MEMBERS TO BE DONE ONLY WITH THE WRITTEN APPROVAL OF THE ARCHITECT. 6. PIPE ROUTING SHOWN SHALL BE USED AND ANY ADDITIONAL OFFSETS OR FITTINGS REQUIRED FOR PROPER INSTALLATION, COORDINATION WITH OTHER TRADES, AND/OR TO MAINTAIN PROPER CLEARANCES SHALL BE PROVIDED. VERIFY EXISTING STRUCTURAL, MECHANICAL, ELECTRICAL INSTALLATIONS AND AVOID ANY/ALL OBSTRUCTIONS OR INTERFERENCES WITH FIRE PROTECTION PIPE ROUTING. 7. FIRE STOP ALL PENETRATIONS OF SMOKE/FIRE WALLS, CEILINGS, FLOORS, ROOFS, ETC. FLASH AND COUNTERFLASH ROOF PENETRATIONS. (SEE FIRE RATED PIPE PENETRATION DETAIL). 8. PROVIDE ACCESS PANELS TO ALL VALVES ABOVE NON -ACCESSIBLE CEILINGS AND CHASES. 9. SPRINKLER HEADS ARE TO BE COORDINATED WITH ALL EXISTING/NEW DIFFUSERS, SPEAKERS, LIGHTING FIXTURES AND CEILING SYSTEMS. 10. METHODS OF HANGING PIPES, HEADERS AND BRANCHES SHALL BE IN ACCORDANCE WITH N.F.P.A. 13. 11. AUTOMATIC SPRINKLER TEMPERATURE RATINGS OF FUSIBLE ELEMENTS TO BE IN ACCORDANCE WITH N.F.P.A. 13. 12. ALL VALVES FOR FIRE SERVICE SHALL BE LISTED BY THE UNDERWRITER'S LABORATORIES, INC. AND THE FACTORY MUTUAL LABORATORIES. VALVES SHALL BE FACTORY MARKED "UL" AND "FM", 175 WORKING PRESSURE. 13. ALL VALVES ON THE FIRE PROTECTION SYSTEM TO BE ELECTRICALLY SUPERVISED. TYPE AND EXACT LOCATION OF FLOW, PRESSURE AND SUPERVISORY SWITCHES SHALL FACTORY MARKED "UL" AND "FM", 175 WORKING PRESSURE. 14. ALL POWER WIRING SHALL BE ACCOMPLISHED UNDER THE ELECTRICAL DIVISION. ALL CONTROL AND INTERLOCK WIRING SHALL BE ACCOMPLISHED UNDER THIS SECTION OF THE SPECIFICATIONS IN ACCORDANCE WITH THE REQUIREMENTS IN THE ELECTRICAL DIVISION. COORDINATE ALL ELECTRICAL ITEMS WITH ELECTRICAL CONTRACTOR AND INSURE PROPER COORDINATION. 15. SPRINKLERS SHALL COVER THE ENTIRE AREA OF THE ROOM INCLUDING ALCOVES. SPRAY SHALL NOT BE BLOCKED BY WALLS OR PARTITIONS. 16. ALL SPRINKLER HEADS MOUNTED IN CEILING SHALL BE LOCATED A MINIMUM OF 4" AWAY FROM ANY WALLS, CEILING HEIGHT CHANGES OR ANY OTHER VERTICAL INTERSECTING SURFACE. 17. PIPE SHALL BE REAMED AND CLEANED BEFORE ASSEMBLY. 18. MAINTAIN A MINIMUM OF 18 INCHES FROM THE BOTTOM OF THE SPRINKLER DEFLECTOR TO THE TOP OF STORAGE/FILE STORAGE. 19. PROVIDE SPRINKLERS ABOVE AND BELOW EXPOSED DUCTWORK4 FEET OR WIDER. 20. FIRE SPRINKLER SYSTEM TO BE MONITORED BY FIRE ALARM SYSTEM BY OTHERS. 21. 0 INDICATES HYDRAULIC REFERENCE NODES LAUNDER MAIL DROP -IN ANCHOR 3/Ni ROD COUPURD w 3ro• ALL TI1 ROD -A T NfS (AAt101. OR OA. AH ) . (sI9 VTO 4 ) (.9 + TYPICAL HANGER DETAIL N.T.B. PIPE SQE RDD SRE ME or 4N. 'w MAX. 'C' rAsnm DIM. DDI. 3/4' 3/B' 1-3/6' X 1-17/32- DROP-N ANCHOR Im 1-6/6' 13/16' 1-7/6' 1-1/Y 16/16' 2• 2' 1-3/16 2-3/B' 2-1/2' 1/2' 1-1/2' X 2-1/32- DROP -IN ANCHOR 1-7/16' 2-3/4- ]' 1-3/4• 3-1/4' 2' 4' 5/N1' 1-6/6' X 2-16/32' DROP -IN ANCHOR 2-1/4- 3-7/8• B' 2-3/4' 4-3/4' 6' 3/4- 1-3/4- X 3-1/4'. DRP.-LAN ANC. 3-6/1V 5-1/2- N/A N/A N/A WA ROOF FLOOR Fire Sprinkler Piping Plan SCALE: 1 /8"=1'-0" RISER CLAMP (B-LINE MODEL B3373CTC OR EQUAL) MIN t' THICK MEDIUM DENSITY 3x3x1/4 NEOPRENE STEEL PLATES CONCR.FLOCR (CLUE TOGETHER WITH NEOPRENE PAD TO FORM ONE UNIT. USE CONTACT CEMENT). ELEVATION No. Date Revisions By Water Supply Information 1 2/9/2009 SUBMIT FOR APPROVAL JRGN Static Pressure 55 PSI Residual Pressure 53 PSI Pitot Reading 42 Flow In G.p.m. 1860 Date Of Test 2/9/09 Time Of Test 12:15 Test Taken By LT M FERNANDEZ Hydrant Location 5876 SW 68 ST SEE FIRESTDP DETAIL 3' PLAN VIEW 3' NOTE: PROVIDE RISER CLAMP BEND STRAPS AT EVERY OTHER FLOOR LAB CONTROL VALVE WITH TAMPER SWITCH , V v WATER FLOW SWITCH 0 PRESSURE GAUGE TO SPRINKLER fl-A+ 11 8 w DRAIN/TEST 1" DRAIN FOR 1 %" CONTROL VALVE ASSEMBLY -� 11/" DRAIN FOR 2%" CONTROL VALVE 1/2" RISER 1 1 /4" DRAIN LAB ti..M v v •v•v d,v vw v V v V V" v V v V v FIRE SPRINKLER CONTROL VALVE ASSEMBLY DETAIL N.T.S. Design Criteria Sprinklers/ Spacing System No. Symbol Qty Size K Temp Description SIN Design Area Area #1 Area #2 9 1/2" 5.6 155 TYCO-QUICK RESPONSE WHITE TY-FRB SEMI REC PENDENT TY-3231 Density 10 GPM/SQ.FT 10 GPM/SQ.FT Design Area S.f. 225 225 Psi Req'd ® City Main 54.93 54.95 Gpm Req'd 0 City Main 306.7 250.3 Gpm Req'd 0 Basr 50.06 39.72 No. Spkr. In Dsgn. Area 9 9 Elev. 0 Highest Spkr 10' 20' Domestic/outside Hose 100 100 9 Total This Sheet I I I I I I I I I D.1 D I I I I I I C B A VE IOC-04 REVM'SP NGS N,F.PA 13 AND LfANCF �t�TER THESE FOR r 004 (0 �1Gt't SYSTFti�18r} i .G 13.'3'?. FAC• 0 FtKE Na�O-[Fs.:. T 1(3,� TrtJ`�� BASE) I A Cdy Or t*o SD tli3'rt}; A �RVc ;A11:� 1I :=rc%P Fq'FtrOVAL DRbtltl • �ftiiP+G�rU. S^t•IAOP 0+ MAXIMUM DISTANCE BETWEEN HANGERS NOMINAL PIPE 3/4" 1" 1-1/4" 1-1/2" 2" 2-1/2" 3" 3-1/2" 4" 5" 6" 8" SIZE (in.) STEEL PIPE EXCEPT N/A 12-0 12-0 15-0 15-0 15-0 15-0 15-0 15-0 15-0 15-0 15-0 THREADED UGHTWALL THREADED LIGHTWALL N/A 12-0 12-0 12-0 12-0 12-0 12-0 N/A N/A N/A N/A N/A STEEL PIPE COPPER TUBE 8-0 8-0 10-0 10-0 12-0 12-0 12-0 15-0 15-0 15-0 15-0 15-0 CPVC 5-6 6-0 6-6 7-0 8-0 9-0 12-0 N/A N/A N/A N/A N/A POLYBUMENE (IPS) N/A 1 3-9 4-7 5-0 5-11 N/A N/A N/A N/A N/A N/A N/A POLYBUTYLENE (CTS) 1 2-11 1 3-4 3-11 4-5 5-5 N/A N/A I N/A N/A N/A N/A N/A Project SOMERSET CHARTER SCHOOL 5876 SW 68 ST Fire SM Miami, Florida 33143 I: 'ntrnct With: Syatam No. 1 Date: 2/9/2009 Drawn By All Fire Sprinklers Sea1ai 1/8"= V-0" 7492 N.W. 8nd Street Chackad er: All Fire Sprinklers Authority Having Jurisdiction Medley,Florida 33126 Totd /1/S: 244 TEL:(305) 403-4455 FAX:(305) 403-4488 Contract ND. 7 State Certification # 56528000012005 09- FP-3 Of �J