09-49-059TYPE: LOADCENTER MAIN BUS: 125 A SERVICE: POWER & LIGHTING NEUTRAL: 125 A VOLTAGE: 120/208V, 3P, 4W PANEL M A MAINS: M.L.O. MOUNTING: AS SHOWN I.A.C. 10 K SERIES RATED. AMPS POLE TOTAL V.A. COND WIRE REMARKS CKT. NO, PHASE CKT. NO, REMARKS WIRE COND TOTAL V.A. POLE AMPS 20 1 720 112" 12 RECEPT. CLASSROOM 101 1 2 LIGHTS CLASSROOMS 101,102 12 1/2" 1,440 1 20 20 1 540 1/2" 12 RECEPT. CLASSROOM 101 3 4 LIGHTS CLASSROOMS 103,104 12 112" 1,440 1 20 20 1 1 720 1/2" 1 12 1 RECEPT. CLASSROOM 102 5 6 LIGHTS CLASSROOMS 105,106 12 1 1/2' 1,440 1 1 20 20 1 540 112" 12 RECEPT. CLASSROOM 102 7 8 LIGHTS CLASSROOMS 107 12 1/2" 576 1 20 20 1 720 1/2" 12 RECEPT. CLASSROOM 103 9 10 LIGHTS CLASSROOMS 108,109 12 1/2" 1,440 1 20 20 1 540 1/2" 12 RECEPT. CLASSROOM 103 11 12 LIGHTS CLASSROOMS 110,111 12 1/2" 1,440 1 20 20 1 720 112" 12 RECEPT. CLASSROOM 104 13 14 LIGHTS CLASSROOMS 112,113 12 1/2" 1.440 1 20 20 1 1 540 1/2" 1 12 RECEPT. CLASSROOM 104 15 16 LIGHTS FOOD PREPARATION 12 1/2' 1 1,056 1 20 20 1 720 1/2" 12 RECEPT. CLASSROOM 105 17 18 LIGHTS CORRIDOR' 12 1/2" 1,064 1 20 20 1 540 1/2" 12 RECEPT. CLASSROOM 105 19 20 LIGHTS CORRIDOR' 12 1/2" 1,068 1 20 20 1 720 1/2' 12 RECEPT. CLASSROOM 106 21 22 LIGHTS OFFICE AREA 12 1/2" 670 1 20 20 1 540 1/2' 12 RECEPT. CLASSROOM 106 23 24 LIGHTS STAIRS' 12 1 1/2" 1,440 1 1 20 20 1 720 1/2" 1 12 RECEPT. CLASSROOM 107 25 26 RECEPT. CLASSROOM 111 12 1/2" 540 1 20 20 1 540 1/2' 12 RECEPT. CLASSROOM 107 27 28 RECEPT. CLASSROOM 112 12 1/2" 720 1 20 20 1 720 1/2' 12 RECEPT. CLASSROOM 108 29 30 RECEPT. CLASSROOM 112 12 1/2" 540 1 20 20 1 540 1/2" 12 1 RECEPT. CLASSROOM 108 31 32 RECEPT. CLASSROOM 113 12 1/2" 720 1 20 20 1 720 1/2" 12 RECEPT. CLASSROOM 109 33 34 RECEPT. CLASSROOM 113 12 1/2' 1 540 1 1 20 20 1 540 112" 12 RECEPT. CLASSROOM 109 35 36 SPACE - - - - - 20 1 720 112" 12 RECEPT. CLASSROOM 110 37 38 SPACE - - - 20 1 540 1 1/2' 1 12 RECEPT. CLASSROOM 110 39 40 SPACE - - 20 1 720 1 1/2" 1 12 1 RECEPT. CLASSROOM 111 41 42 SPACE - - - - - TOTAL CONNECTED LOAD: 30,894 VA 86 AMPS FEEDER: 4#1 THWN Cu. & 1#6 GND IN 1-1/2" C. FEED FROM: PANEL MOP NOTES: 1. CONNECT EMERGENCY FIXTURES TO UNSWITCHED HOT LEG OF CIRCUIT. 2. BREAKER SHALL BE MARKED "SWD" AT THE PANEL FOR UNSWITCHED LIGHTS. CONTROLLED BY TIME SWITCH OR LIGHTING CONTACTOR. GROUND FAULT CIRCUIT INTERRUPTER. •" SHUTN-TRIP. LARGEST OF NON -COINCIDENT LOADS. TYPE: LOADCENTER MAIN BUS: 125 A SERVICE: POWER & LIGHTING PANEL H 1 B NEUTRAL: 125 A VOLTAGE: 120/208V, 3P, 4W MAINS: M.L.O. MOUNTING: AS SHOWN I.A.C. 10 K SERIES RATED. AMPS POLE TOTAL V.A. COND WIRE REMARKS CKT, NO, PHASE CKT, NO, REMARKS WIRE COND TOTAL V.A. POLE AMPS 20 1 720 1/2" 12 RECEPT. CORRIDOR 1 2 WATER HEATER 8 3/4" 11,250 3 40 20 1 360 1/2' 12 RECEPT. CORRIDOR" 3 4 20 1 360 1/2" 12 RECEPT. OFFICE 1 5 6 20 1 540 1/2' 12 RECEPT. OFFICE 2 7 8 FOOD PROCESSOR 12 112" 500 1 20 20 1 1,200 1/2" 12 REFRIGERATOR 9 10 RECEPT. APPLIANCE" 12 1/2" 180 1 20 20 1 1,500 1/2" 12 APPLIANCE" 11 12 RECEPT. APPLIANCE" 12 1/2" 180 1 20 20 1 1,500 1/2" 12 APPLIANCE" 13 14 FOOD PROCESSOR 12 1/2" 500 1 20 20 1 180 1/2' 12 RECEPT. BATHRROM " 15 16 HOT FOOD TABLE 10 1/2" 2,000 1 30 20 1 180 1/2' 12 RECEPT. BATHRROM " 17 18 ICE MAKER 12 1/2" 1,440 1 1 15 20 1 1,000 1/2' 12 RECEPT. WATER FOUNTAIN " 19 20 MILK COOLER 12 1/2" 1,092 1 20 20 1 1,000 1/2" 12 RECEPT. WATER FOUNTAIN" 21 22 CASHIER" 12 1 1/2" 300 1 20 20 1 720 1/2' 12 RECEPT. FOOD PREP. "' 23 24 CASHIER" 12 1/2" 300 1 20 20 1 180 1/2' 12 RECEPT. BATHRROM " 25 26 HOT FOOD TABLE 10 1/2' 2,000 1 30 20 1 180 1/2' 12 RECEPT. BATHRROM " 27 28 HOT FOOD TABLE 10 1/2" 2,000 1 30 20 1 180 1/2" 12 RECEPT. BATHRROM " 29 30 HOT FOOD TABLE 10 1/2" 2,000 1 30 20 1 180 112" 12 RECEPT. BATHRROM " 31 32 EXTERIOR LIGHTING 12 1/2" 1,500 2 20 20 1 180 1/2" 12 RECEPT. BATHRROM " 33 34 20 1 180 1/2" 12 RECEPT. BATHRROM" 35 36 TELEPHONE PANEL 12 1/2" 1 1,000 1 20 20 1 360 1/2" 12 RECEPT. ELECTRICAL ROOM " 37 38 TV EQUIPMENT 12 1/2" 500 1 20 20 1 360 1/2" 12 RECEPT. DUMPSTER" 39 40 FIRE ALARM PANEL 12 1/2" 500 1 20 20 1 1,200 1/2" 12 REFRIGERATOR 41 42 SPACE - - - - - TOTAL CONNECTED LOAD: 39,502 VA 110 AMPS FEEDER: 4#1 THWN Cu. & 1#6 GND IN 1-1/2" C. FEED FROM: PANEL MDP NOTES: 1. CONNECT EMERGENCY FIXTURES TO UNSWITCHED HOT LEG OF CIRCUIT. 2. BREAKER SHALL BE MARKED "SWD" AT THE PANEL FOR UNSWITCHED LIGHTS. CONTROLLED BY TIME SWITCH OR LIGHTING CONTACTOR. " GROUND FAULT CIRCUIT INTERRUPTER. SHUTN-TRIP. LARGEST OF NON -COINCIDENT LOADS. TYPE: LOADCENTER MAIN BUS: 150 A SERVICE: POWER & LIGHTING PAN EL H 1 C NEUTRAL: 150 A VOLTAGE: 120/208V, 3P, 4W MAINS: M.L.O. MOUNTING: AS SHOWN I.A.C. 22 K SERIES RATED. AMPS POLE TOTAL V.A. COND WIRE REMARKS CKT, NO, PHASE CKT. NO. REMARKS WIRE COND TOTAL V.A. POLE AMPS 20 2 2,600 1/2" 12 AC-1 CLASSROOM 101 1 2 AC-4 CLASSROOM 108 12 1/2" 2,600 2 20 3 4 20 2 2,600 1/2" 12 1 AC-2 CLASSROOM 102 5 6 AC-4 CLASSROOM 109 12 1 1/2" 2,600 2 20 7 8 20 2 2,600 1/2" 12 AC-2 CLASSROOM 103 9 10 AC4 CLASSROOM 110 12 112" 2,600 2 20 11 12 20 2 1 2,600 112" 12 AC-2 CLASSROOM 104 13 14 AC-4 CLASSROOM 111 12 1/2" 2,600 1 2 20 15 16 20 2 2,600 1/2" 12 AC-2 CLASSROOM 105 17 18 AC-4 CLASSROOM 112 12 1/2" 2,600 2 20 19 20 20 2 2,600 1/2" 12 AC-2 CLASSROOM 106 21 22 AC-5 CLASSROOM 113 12 1/2" 2,600 2 20 23 24 20 2 2,600 1/2" 1 12 AC-3 CLASSROOM 107 25 26 AC-11 CORRIDOR 1ST FLR. 8 1 3/4" 5,928 2 40 27 28 25 2 4,118 3/4" 10 AC-12 FOOD PREPARATION 29 30 EF-6 12 1/2" 120 1 15 31 32 SPACE - - - - - 15 1 129 1/2" 12 EF4 33 34 SPACE - - - 15 1 45 1/2" 1 12 EF-5 35 36 SPACE - - - - - - - - SPACE 37 38 SPACE - - - - - - - - SPACE 39 40 SPACE - - - - - - - - SPACE 41 42 SPACE - - TOTAL CONNECTED LOAD: 44,140 VA 123 AMPS FEEDER: 4#1/0 THWN Cu. & 1#6 GND IN 2" C. FEED FROM: PANEL MDP NOTES: 1. CONNECT EMERGENCY FIXTURES TO UNSWITCHED HOT LEG OF CIRCUIT. 2. BREAKER SHALL BE MARKED "SWD" AT THE PANEL FOR UNSWITCHED LIGHTS. CONTROLLED BY TIME SWITCH OR LIGHTING CONTACTOR. GROUND FAULT CIRCUIT INTERRUPTER. SHUTN-TRIP. LARGEST OF NON -COINCIDENT LOADS. TYPE: LOADCENTER MAIN BUS: 125 A SERVICE: POWER & LIGHTING NEUTRAL: 125 A VOLTAGE., 120/208V, 3P, 4W PANEL H2A MAINS: M.L.O. MOUNTING: AS SHOWN I.A.C. 10 K SERIES RATED. AMPS POLE TOTAL V.A. COND WIRE REMARKS CKT. NO. PHASE CKT. NO, REMARKS WIRE COND TOTAL V.A. POLE AMPS 20 1 720 1/2" 12 RECEPT. CLASSROOM 201 1 2 LIGHTS CLASSROOMS 201 12 1/2" 868 1 20 20 1 540 1/2" 12 RECEPT. CLASSROOM 201 3 4 LIGHTS CLASSROOMS 202 12 1/2' 868 1 20 20 1 1 1 720 1/2" 12 RECEPT. CLASSROOM 202 5 6 LIGHTS CLASSROOMS 203 12 1 1/2' 868 1 1 20 20 1 540 1/2" 12 RECEPT. CLASSROOM 202 7 8 LIGHTS CLASSROOMS 204 12 1/2" 868 1 20 20 1 720 1/2" 12 RECEPT. CLASSROOM 203 9 10 LIGHTS CLASSROOMS 205 12 1/2' 868 1 20 20 1 540 1/2" 12 RECEPT. CLASSROOM 203 11 12 LIGHTS CLASSROOMS 206 12 1/2" 868 1 20 20 1 720 1/2" 12 RECEPT. CLASSROOM 204 13 14 LIGHTS CLASSROOMS 207 12 1/2' 868 1 20 20 1 1 1 540 1/2" 12 RECEPT. CLASSROOM 204 15 16 LIGHTS CLASSROOMS 208 12 1 1/2' 868 1 20 20 1 1 720 1/2" 1 12 RECEPT. CLASSROOM 205 17 18 LIGHTS CLASSROOMS 209 12 1/2" 868 1 20 20 1 1 540 1/2" 12 RECEPT. CLASSROOM 205 19 20 LIGHTS CLASSROOMS 210 12 1/2' 868 1 20 20 1 720 1/2" 12 RECEPT. CLASSROOM 211 21 22 LIGHTS CLASSROOMS 211 12 1/2" 868 1 20 20 1 540 112" 12 RECEPT. CLASSROOM 211 23 24 LIGHTS CLASSROOMS 212 12 112" 868 1 20 20 1 1 720 1/2" 12 RECEPT. CLASSROOM 212 25 26 LIGHTS CLASSROOMS 213 12 1 1/2" 868 1 20 20 1 540 1/2" 12 RECEPT. CLASSROOM 212 27 28 LIGHTS BATHROOMS 12 112" 676 1 20 20 1 720 1/2" 12 RECEPT. CLASSROOM 213 29 30 LIGHTS LIBRARY 12 1/2" 1,348 1 20 20 1 540 1/2" 12 1 RECEPT. CLASSROOM 213 31 32 LIGHTS LIBRARY 12 1/2" 1,348 1 20 20 1 720 1/2" 12 RECEPT. CLASSROOM 209 33 34 LIGHTS CORRIDOR' 12 1/2" 1 1,052 1 1 20 20 1 540 1/2" 12 RECEPT. CLASSROOM 209 35 36 LIGHTS CORRIDOR' 12 1/2" 968 1 20 20 1 720 1 1/2" 12 RECEPT. CLASSROOM 210 37 38 LIGHTS SCIENCE LAB 12 1/2" 666 1 20 20 1 540 1 1/2' 12 RECEPT. CLASSROOM 210 39 40 LIGHTS LOUNGE 12 1/2" 576 1 20 20 1 540 I 1/2" 12 1 RECEPT. CORRIDOR 41 42 SPACE - I - I - - TOTAL CONNECTED LOAD: 31,058 VA 86 AMPS FEEDER: 4#1 THWN Cu. & 1#6 GND IN 1-1/2" C. FEED FROM: PANEL MDP NOTES: 1. CONNECT EMERGENCY FIXTURES TO UNSWITCHED HOT LEG OF CIRCUIT. 2. BREAKER SHALL BE MARKED "SWD" AT THE PANEL FOR UNSWITCHED LIGHTS. CONTROLLED BY TIME SWITCH OR LIGHTING CONTACTOR. GROUND FAULT CIRCUIT INTERRUPTER. SHUTN-TRIP. LARGEST OF NON -COINCIDENT LOADS. TYPE: LOADCENTER MAIN BUS: 100 A SERVICE: POWER & LIGHTING PANEL H2B NEUTRAL: 100 A VOLTAGE: 120/208V, 3P, 4W MAINS: M.L.O. MOUNTING: AS SHOWN I.A.C. 10 K SERIES RATED. AMPS POLE TOTAL V.A. COND WIRE REMARKS CKT. NO. PHASE CKT. NO, REMARKS WIRE COND TOTAL V,A, POLE AMPS 20 1 1,000 1/2" 12 RECEPT. WATER FOUNTAIN " 1 2 REFRIGERATOR 12 1/2" 1,200 1 20 20 1 1,000 1/2" 12 RECEPT. WATER FOUNTAIN " 3 4 RECEPT. APPLIANCE'• 12 1/2" 1,000 1 20 20 1 1 900 1/2' 12 RECEPT. LIBRARY 5 8 1 RECEPT. APPLIANCE" 12 1 1/2' 1,000 1 1 20 20 1 900 1/2' 12 RECEPT. LIBRARY 7 8 RECEPT. APPLIANCE" 12 1/2" 1,000 1 20 20 1 900 1/2' 12 RECEPT. LIBRARY 9 10 RECEPT. LOUNGE 12 1/2" 1,000 1 20 20 1 900 112" 12 RECEPT. LIBRARY 11 12 RECEPT. LOUNGE 12 1/2' 360 1 20 20 1 900 1/2" 12 RECEPT. LIBRARY 13 1 C O 1 /2" 180 1 20 20 1 180 1/2" 12 RECEPT. BATHROOM •' 15 16 EXTERIOR LIGHTING' 12 1/2" 2,700 2 20 20 1 180 1/2' 12 RECEPT. BATHROOM" 17 18 20 1 180 1/2" 12 RECEPT. BATHROOM •' 19 20 SPACE - - - - 20 1 180 1 1/2" 12 1 RECEPT. BATHROOM •' 21 22 SPACE - - - - 20 1 1 720 1/2" 12 RECEPT. CLASSROOM 206 23 24 SPACE - - 20 1 540 1/2' 12 RECEPT. CLASSROOM 206 25 26 SPACE - - - - - 20 1 720 1/2' 12 RECEPT. CLASSROOM 207 27 28 SPACE - - - - 20 1 540 1/2' 12 RECEPT. CLASSROOM 207 29 30 SPACE - - - 20 1 720 1/2' 12 1 RECEPT. CLASSROOM 208 31 32 SPACE - - 20 1 540 1/2" 12 RECEPT. CLASSROOM 208 33 34 SPACE - - - - 20 1 720 1/2" 12 RECEPT. CORRIDOR 35 36 SPACE - - - 20 1 180 1/2" 12 JANITOR ROOM •• 37 38 SPACE - - - - - - - SPACE 39 40 SPACE - - - - - - SPACE 41 42 SPACE - - - - TOTAL CONNECTED LOAD: 20,340 VA 57 AMPS FEEDER: 4#3 THWN Cu. & 1#8THWN IN 1-1/4" C. QFEED FROM: PANEL MDP NOTES: 1. CONNECT EMERGENCY FIXTURES TO UNSWITCHED HOT LEG OF CIRCUIT. 2. BREAKER SHALL BE MARKED "SWD" AT THE PANEL FOR UNSWITCHED LIGHTS. CONTROLLED BY TIME SWITCH OR LIGHTING CONTACTOR. GROUND FAULT CIRCUIT INTERRUPTER. SHUTN-TRIP. LARGEST OF NON -COINCIDENT LOADS. TYPE: LOADCENTER MAIN BUS: 200 A SERVICE: POWER & LIGHTING PANEL H2C NEUTRAL: 200 A VOLTAGE: 120/208V, 3P, 4W MAINS: M.L.O. MOUNTING: AS SHOWN I.A.C. 22 K SERIES RATED. AMPS POLE TOTAL V.A. COND WIRE REMARKS CKT. NO, PHASE CKT, NO, REMARKS WIRE COND TOTAL V.A. POLE AMPS 15 2 2,080 1/2" 12 CU-1 CLASSROOM 101 1 2 CU-4 CLASSROOM 108 12 1/2" 2,080 2 15 3 4 15 1 2 2,080 1/2" 12 CU-2 CLASSROOM 102 5 6 CU-4 CLASSROOM 109 12 1/2" 2,080 2 15 7 8 15 2 2,080 1/2" 12 CU-2 CLASSROOM 103 9 10 CU4 CLASSROOM 110 12 1/2" 2,080 2 15 11 12 15 2 2,080 1/2" 12 CU-2 CLASSROOM 104 13 14 CU4 CLASSROOM 111 12 1/2" 1 2,080 2 15 15 16 15 2 2,080 1/2' 12 CU-2 CLASSROOM 105 17 18 CU4 CLASSROOM 112 12 1/2" 2,080 2 15 19 20 15 2 2,080 1/2" 12 1 CU-2 CLASSROOM 106 21 22 CU4 CLASSROOM 113 12 1/2" 2,080 2 15 23 24 15 2 2,080 1/2" 12 CU-3 CLASSROOM 107 25 26 CU-11 CORRIDOR 1ST FLR 10 3/4" 3,952 1 2 25 27 28 25 2 3,952 1/2' 10 CU-12 FOOD PREPARATION 29 30 RTU-2 8 3/4" 15.480 3 45 31 32 45 3 12,384 1 3/4' 8 ERVA 33 34 35 36 SPACE - - - - 37 38 SPACE - - - - - - - - - SPACE 1 39 SPACE - - - - 1140 - - - - - SPACE 1 41 42 SPACE - - - - TOTAL CONNECTED LOAD: 62,808 VA 174 AMPS FEEDER: 4#2/0 THWN Cu. & 1#6 THWN IN 2" C. FEED FROM: PANEL MDP NOTES: 1. CONNECT EMERGENCY FIXTURES TO UNSWITCHED HOT LEG OF CIRCUIT. 2. BREAKER SHALL BE MARKED'SWD" AT THE PANEL FOR UNSWITCHED LIGHTS. CONTROLLED BY TIME SWITCH OR LIGHTING CONTACTOR. GROUND FAULT CIRCUIT INTERRUPTER. •" SHUTN-TRIP. LARGEST OF NON -COINCIDENT LOADS. TYPE: LOADCENTER MAIN BUS: 125 A SERVICE: POWER & LIGHTING NEUTRAL: 125 A VOLTAGE: 120/208V, 3P, 4W PANEL H2D MAINS: M.L.O. MOUNTING: AS SHOWN I.A.C. 10 K SERIES RATED. AMPS POLE TOTAL V.A. COND WIRE REMARKS CKT. NO, PHASE CKT. NO, REMARKS WIRE COND TOTAL V.A. POLE AMPS 25 2 3,952 1/2" 10 AC-6 CLASSROOM 201•"• 1 2 CU-6 CLASSROOM 201'•" 12 1/2' 2787 2 20 3 4 25 2 3,952 1/2' 10 AC-7 CLASSROOM 202•'" 5 6 CU-7 CLASSROOM 202••" 12 1 1/2" 2.787 1 2 20 7 8 25 2 3,952 1/2" 10 AC-7 CLASSROOM 203•'" 9 10 CU-7 CLASSROOM 203"•• 12 112" 2,787 2 20 11 12 25 2 3,952 1/2' 1 10 AC-7 CLASSROOM 204•"' 13 14 CU-7 CLASSROOM 204••" 12 1/2" 2,787 2 1 20 15 18 25 2 3.952 1/2' 10 AC-7 CLASSROOM 205"" 17 18 CU-7 CLASSROOM 205'•'• 12 1/2" 2,787 2 20 19 20 25 2 3,952 1/2' 10 1 AC-7 CLASSROOM 206'"' 21 22 CU-7 CLASSROOM 206•"' 12 1/2" 2,787 2 20 23 24 25 2 3,952 1/2" 10 AC-8 CLASSROOM 207•"' 25 26 CU-8 CLASSROOM 207'•" 12 1 1/2' 2,787 2 20 27 28 25 2 3,952 1/2" 10 AC-9 CLASSROOM 208'"' 29 30 CU-9 CLASSROOM 208"•• 12 3/4' 2,787 1 2 20 31 32 25 2 3,952 1/2" 10 AC-9 CLASSROOM 209"•' 33 34 CU-9 CLASSROOM 209••" 12 112" 2,787 2 20 35 36 25 2 3,952 1/2" 10 AC-9 CLASSROOM 210••" 37 38 CU-9 CLASSROOM 210•"• 12 1/2" 2,787 2 20 '119 40 15 1 1135 1/2" 12 EF-10 1 41 42 EF-12 12 3/4' 1 45 1 15 TOTAL CONNECTD: 39,700 VA 110 AMPS ED LOAFEEDER: 4#1 THWN Cu. & 1#6 GND IN 1-1/2" C. FEED FROM: PANEL MDP NOTES: 1. CONNECT EMERGENCY FIXTURES TO UNSWITCHED HOT LEG OF CIRCUIT. 2. BREAKER SHALL BE MARKED "SWD" AT THE PANEL FOR UNSWITCHED LIGHTS. CONTROLLED BY TIME SWITCH OR LIGHTING CONTACTOR. GROUND FAULT CIRCUIT INTERRUPTER. SHUTN-TRIP. LARGEST OF NON -COINCIDENT LOADS. TYPE: LOADCENTER MAIN BUS: 200 A SERVICE: POWER & LIGHTING PANEL H2E NEUTRAL: 200 A VOLTAGE: 120/208V, 3P, 4W MAINS: M.L.O. MOUNTING: AS SHOWN I.A.C. 42 K SERIES RATED. AMPS POLE TOTAL V.A. COND WIRE REMARKS CKT, NO, PHASE CKT. NO, REMARKS WIRE COND TOTAL V.A. POLE AMPS 25 2 3,952 1/2' 10 AC-9 CLASSROOM 211'•" 1 2 CU-9 CLASSROOM 211•"' 12 1/2' 2787 2 20 3 4 25 1 2 1 3,952 1/2' 10 AC-9 CLASSROOM 212'•" 5 6 CU-9 CLASSROOM 212'"• 12 1/2' 2.787 1 2 20 7 8 25 2 3,952 1/2' 10 AC-10 CLASSROOM 213- 9 10 CU-10 CLASSROOM 213"" 12 1/2' 2,787 2 20 11 12 25 2 3,952 1/2" 10 AC-13 CORRIDOR 2ND FLR.'••• 13 14 CU-13 CORRIDOR 2ND FL."" 10 1/2' 4,160 2 30 15 16 100 4 1 16,370 1-1/4" 3 ELEVATOR •" 17 18 RECEPT. ROOF" 12 1 1/2' 540 1 20 19 20 RECEPT. ROOF" 12 1/2' 900 1 20 21 22 RECEPT. ROOF" 12 1/2' 180 1 20 23 24 SIGN 12 1/2" 1,200 2 20 20 1 100 1/2" 12 SHUNT TRIP CONTROL 25 2 20 1 800 1/2' 12 ELEVATOR PIT " 27 28 RTU-1 8 3/4" 5,200 2 35 20 1 200 1/2' 12 ELEVATOR CABIN •• 29 30 20 1 120 1/2" 12 LIGHTS ELEV. ROOM 31 32 SPACE - - - - - 20 1 360 1/2" 12 RECEPT. ELEV. ROOM " 33 34 SPACE - - - - - 20 1 120 1/2' 12 EF-13 35 36 SPACE - - - - 20 1 4,464 3/4" 8 PANEL H2F 37 38 SPACE - - - - 39 40 SPACE - - - - 41 42 1 SPACE - - - - TOTAL CONNECTED LOAD: 46,594 VA 129 AMPS FEEDER: 4#2/0 THWN Cu. & 1#6 GND IN 2" C. QFEED FROM: PANEL MDP NOTES: 1. CONNECT EMERGENCY FIXTURES TO UNSWITCHED HOT LEG OF CIRCUIT. 2. BREAKER SHALL BE MARKED "SWD" AT THE PANEL FOR UNSWITCHED LIGHTS. ' CONTROLLED BY TIME SWITCH OR LIGHTING CONTACTOR. " GROUND FAULT CIRCUIT INTERRUPTER. SHUTN-TRIP. LARGEST OF NON -COINCIDENT LOADS. TYPE: LOADCENTER MAIN BUS: 60 A SERVICE: POWER & LIGHTING PANEL H2F NEUTRAL: 60A VOLTAGE: 120/208V, 3P, 4W MAINS: M.L.O. MOUNTING: AS SHOWN I.A.C. 10 K SERIES RATED. AMPS POLE TOTAL V.A. COND WIRE REMARKS CKT. NO, PHASE CKT. NO, REMARKS WIRE COND TOTAL V.A. POLE AMPS 20 1 180 1/2" 12 FUME HOOD OUTLET" 1 2 RECEPT. SCIENCE LAB " 12 1/2" 360 1 20 20 1 180 1/2' 12 E.P.O. SWITCH POWER 3 4 RECEPT. SCIENCE LAB " 12 1/2' 720 1 20 - - - - SPACE 5 6 RECEPT. SCIENCE LAB" 12 1/2" 720 1 20 8 RECEPT. SCIENCE LAB " 12 112" 540 1 20 - - SPACE 9 10 RECEPT. SCIENCE LAB 12 112" 180 1 20 - - - SPACE 11 12 RECEPT. SCIENCE LAB " 12 1/2' 720 1 20 - - - SPACE 13 14 SPACE - - - - - - - - SPACE 15 16 SPACE - - - - - - - - SPACE 1 17 18 SPACE - - - - - tt7t7t7 TOTAL CONNECTED LOAD: 3,600 VA 10 AMPS FEEDER: 4#6 THWN Cu. & 1#8 GND IN 1" C. FEED FROM: PANEL H2E NOTES: 1. CONNECT EMERGENCY FIXTURES TO UNSWITCHED HOT LEG OF CIRCUIT. 2. BREAKER SHALL BE MARKED "SWD" AT THE PANEL FOR UNSWITCHED LIGHTS. CONTROLLED BY TIME SWITCH OR LIGHTING CONTACTOR. GROUND FAULT CIRCUIT INTERRUPTER. •" SHUTN-TRIP. "'• LARGEST OF NON -COINCIDENT LOADS. C=R-EM0$1 4LEJANDFM REMOS R.A. .-ar_Chl►e-Lts Alejandro Ramos R.A. 0011702 Il -18501 Pines Blvd., Suite 107 Pemhroke PineF Fl, 33029 Tel. (954) 442 7-22 ; Fa;7 (954) 442 7,90 l 9-moil' r9mo5blrfe 0RioI.cnm SOMERSET CHARTER SCHOOL V South Miami -5876 SW 68th Street South Miami, FL 33143 CONSULTANTS: JEANETH ARDILA architect ALBERTO CHINCHILLA architect ALEJANDRO CABAL -CABAL architect MARCEL ADRIAN PEREZ architect -18501 Pines Blvd., Suite 107 Pembroke Pines FL 33029 STRUCTURAL ENG.: EDUARDO GONZALEZ P.E. INC. Structural Engineers State of Florida CA No. 6188 J. Eduardo Gonzflez P.E. -717 Ponce de Le6n Blvd., Suite 335 Coral Gables FL 33134 Tel: (305) 445 5100 Fax: (305) 445 6644 e-mall: eddygon@bellsouth.net M.E.P. ENG.: INGEMEL SA LLC. ENGINEERING COMPANY STATE OF FLORIDA CA No. 9113 Pedro Arias P.E. 53813 Patricia Morales P.E. 63818 -20871 Johnson Street, Suite 115 Pembroke Pines FL 33029 USA Tel: (954) 318 2264 Fax: (954) 450 7216 e-mall: pedroa@ingemel.com pmorales@lngemel.com CIVIL ENG.: Consulting Engeneering & Science, Inc. Nelson H. Ortiz P.E. 57556 -10700 Nort Kendall DrNia Sufta 400 Miami FL 33178 Tel: (305) 378 5555 Fax: (305) 279 4553 e-mall: nonlzpCESMIAMl.00m LANDSCAPE ARCH.: M. L. A. GROUP INC. Scott McClure RtA 566W95 690 NE 13Ih Street Suite 105 Fort Lauderdale FL 33304 Tel: (954) 763 4071 Fax:(954) 46716W e mal: mlagroupinc@yahoo.com SEAL: w l • `1 "tom- P.E.63818 REVISIONS: Q02 / 20 / 09 As per City Remarks Owner's Request Copyright Sheet Title PANEL SCHEDULES Sheet NumberE=6 SOMERSET SOUTH MIAMI Project No: USCB-1 Model File: Drawn by: O.G. Approved by: P.A. Date: 09/08/08 Scale: As Shown f