Loading...
09-49-058TYPE: LOADCENTER MAIN BUS: 125 A SERVICE: POWER & LIGHTING PAN EL H 1 A NEUTRAL: 125 A VOLTAGE: 120/208V, 3P, 4W MAINS: M.L.O. MOUNTING: AS SHOWN I.A.C. 10 K SERIES RATED. AMPS POLE TOTAL V.A. COND WIRE REMARKS CKT, NO, PHASE CKT- NO, REMARKS WIRE COND TOTAL V.A. POLE AMPS 20 1 720 1/2" 12 RECEPT. CLASSROOM 101 1 2 LIGHTS CLASSROOMS 101,102 12 1/2" 1,440 1 20 20 1 540 112" 12 RECEPT. CLASSROOM 101 3 4 LIGHTS CLASSROOMS 103,104 12 1/2" 1,440 1 20 20 1 1 720 1/2" 1 12 1 RECEPT. CLASSROOM 102 5 6 LIGHTS CLASSROOMS 105,106 12 1 1/2" 1,440 1 1 20 20 1 540 1/2' 12 RECEPT. CLASSROOM 102 7 8 LIGHTS CLASSROOMS 107 12 1/2" 576 1 20 20 1 720 112" 12 RECEPT. CLASSROOM 103 9 10 LIGHTS CLASSROOMS 108,109 12 1/2" 1,440 1 20 i i 20 1 540 1/2" 12 RECEPT. CLASSROOM 103 11 12 LIGHTS CLASSROOMS 110,111 12 1/2' 1,440 1 20 20 1 720 1/2" 12 RECEPT. CLASSROOM 104 13 14 LIGHTS CLASSROOMS 112,113 12 1/2' 1,440 1 20 20 1 1 540 1/2" 1 12 1 RECEPT. CLASSROOM 104 15 16 LIGHTS FOOD PREPARATION 12 1 1/2" 1,056 1 1 20 20 1 720 1/2' 12 RECEPT. CLASSROOM 105 17 18 LIGHTS CORRIDOR' 12 1/2" 1,064 1 20 20 1 540 1/2' 12 RECEPT. CLASSROOM 105 19 20 LIGHTS CORRIDOR' 12 1/2" 1,068 1 20 20 1 720 1/2' 12 RECEPT. CLASSROOM 106 21 22 LIGHTS OFFICE AREA 12 1/2' 670 1 20 20 1 540 1/2" 12 RECEPT. CLASSROOM 106 23 24 LIGHTS STAIRS' 12 1/2" 1,440 1 1 20 20 1 720 1/2' 12 RECEPT. CLASSROOM 107 25 26 RECEPT. CLASSROOM 111 12 1 1/2" 540 1 20 20 1 540 1/2' 12 RECEPT. CLASSROOM 107 27 28 RECEPT. CLASSROOM 112 12 1/2" 720 1 20 20 1 720 1/2' 12 RECEPT. CLASSROOM 108 29 30 RECEPT. CLASSROOM 112 12 1/2' 540 1 20 20 1 540 1/2' 12 RECEPT. CLASSROOM 108 31 32 RECEPT. CLASSROOM 113 12 1/2" 720 1 20 40 20 1 720 1/2" 12 RECEPT. CLASSROOM 109 33 34 RECEPT. CLASSROOM 113 12 1/2' 1 540 1 1 20 20 1 540 1/2' 12 RECEPT. CLASSROOM 109 35 36 SPACE - - - - - 20 1 720 1/2" 12 RECEPT. CLASSROOM 110 37 38 SPACE - - - - - 20 1 540 12' 12 RECEPT. CLASSROOM 110 39 1 720 1/2' 12 RECEPT. CLASSROOM 111 41 J:rt:��40SPACE20 SPACE - - - - - TOTAL CONNECTED LOAD: 30,894 VA 86 AMPS FEEDER: 4#1 THWN Cu. & 1#6 GND IN 1-1/2" C. FEED FROM: PANEL MDP NOTES: 1. CONNECT EMERGENCY FIXTURES TO UNSWITCHED HOT LEG OF CIRCUIT. 2. BREAKER SHALL BE MARKED "SWD" AT THE PANEL FOR UNSWITCHED LIGHTS. CONTROLLED BY TIME SWITCH OR LIGHTING CONTACTOR. '• GROUND FAULT CIRCUIT INTERRUPTER. SHUTN-TRIP. LARGEST OF NON -COINCIDENT LOADS. TYPE: LOADCENTER MAIN BUS: 125 A SERVICE: POWER & LIGHTING PANEL H 1 B NEUTRAL: 125 A VOLTAGE: 120/208V, 3P, 4W MAINS: M.L.O. MOUNTING: AS SHOWN I.A.C. 10 K SERIES RATED. AMPS POLE TOTAL VA COND WIRE REMARKS CKT. NO. PHASE CKT. NO, REMARKS WIRE COND TOTAL V.A. POLE AMPS 20 1 720 1/2" 12 RECEPT. CORRIDOR 1 2 WATER HEATER 8 3/4' 11,250 3 40 20 1 360 1/2" 12 RECEPT. CORRIDOR" 3 4 20 1 1 360 1/2' 1 12 1 RECEPT. OFFICE 1 5 6 20 1 540 1/2' 12 RECEPT. OFFICE 2 7 8 FOOD PROCESSOR 12 12" 500 1 20 20 1 1,200 1/2" 12 REFRIGERATOR 9 10 RECEPT. APPLIANCE " 12 1/2' 180 1 20 20 1 1,500 1/2" 12 APPLIANCE" 11 12 RECEPT. APPLIANCE" 12 1/2' 180 1 20 20 1 1,500 1/2" 12 APPLIANCE " 13 14 FOOD PROCESSOR 12 1/2" 500 1 20 20 1 1 180 12" 12 RECEPT. BATHRROM " 15 16 HOT FOOD TABLE 10 1 12' 2,000 1 30 20 1 180 12' 12 RECEPT. BATHRROM " 17 18 ICE MAKER 12 12' 1,440 1 15 20 1 1,000 12" 12 RECEPT. WATER FOUNTAIN " 19 20 MILK COOLER 12 12' 1,092 1 20 20 1 1,000 12" 12 RECEPT. WATER FOUNTAIN " 21 22 CASHIER " 12 12" 300 1 20 20 1 720 12" 12 RECEPT. FOOD PREP. "' 23 24 CASHIER " 12 12' 300 1 20 20 1 180 12" 12 RECEPT. BATHRROM " 25 26 HOT FOOD TABLE 10 12' 2,000 1 30 20 1 180 12" 12 RECEPT. BATHRROM " 27 28 HOT FOOD TABLE 10 12" 2,000 1 30 20 1 180 12' 12 RECEPT. BATHRROM " 29 30 HOT FOOD TABLE 10 12' 2,000 1 30 20 1 180 12" 12 RECEPT. BATHRROM " 31 32 EXTERIOR LIGHTING 12 1/2" 1,500 2 20 20 1 180 12' 12 RECEPT. BATHRROM " 33 34 20 1 180 12" 12 RECEPT. BATHRROM " 35 36 TELEPHONE PANEL 12 12" 1,000 1 20 20 1 360 12" 12 RECEPT. ELECTRICAL ROOM " 37 38 TV EQUIPMENT 12 12" 500 1 20 20 1 360 12' 12 RECEPT. DUMPSTER " 39 40 FIRE ALARM PANEL 12 12' 500 1 20 20 1 1,200 12" 12 REFRIGERATOR 41 42 SPACE - - - - TOTAL CONNECTED LOAD: 39,502 VA 110 AMPS FEEDER: 4#1 THWN Cu. & 1#6 GND IN 1-1/2" C. FEED FROM: PANEL MDP I NOTES: 1. CONNECT EMERGENCY FIXTURES TO UNSWITCHED HOT LEG OF CIRCUIT. 2. BREAKER SHALL BE MARKED "SWD" AT THE PANEL FOR UNSWITCHED LIGHTS. CONTROLLED BY TIME SWITCH OR LIGHTING CONTACTOR. '• GROUND FAULT CIRCUIT INTERRUPTER. "• SHUTN-TRIP. '••• LARGEST OF NON -COINCIDENT LOADS. TYPE: LOADCENTER MAIN BUS: 150 A SERVICE: POWER & LIGHTING PANEL H 1 C NEUTRAL: 150 A VOLTAGE: 120/208V, 3P, 4W MAINS: M.L.O. MOUNTING: AS SHOWN I.A.C. 22 K SERIES RATED. AMPS POLE TOTAL V.A. COND WIRE REMARKS CKT, NO. PHASE CKT, NO, REMARKS WIRE COND TOTAL V,A, POLE AMPS 20 2 2,600 12" 12 AC-1 CLASSROOM 101 1 2 AC-4 CLASSROOM 108 12 12" 2,600 2 20 3 4 20 2 2,6W 12" 12 AC-2 CLASSROOM 102 5 6 AC-4 CLASSROOM 109 12 1 12" 2,600 2 20 7 8 20 2 2,600 12" 12 AC-2 CLASSROOM 103 9 10 AC-4 CLASSROOM 110 12 12" 2,600 2 20 11 12 20 2 2,600 12" 12 AC-2 CLASSROOM 104 13 14 AC-4 CLASSROOM 111 12 12' 2,600 2 20 15 16 20 2 2,600 12' 12 AC-2 CLASSROOM 105 17 18 AC-4 CLASSROOM 112 12 12" 2,600 2 20 19 20 20 2 2,600 12" 12 AC-2 CLASSROOM 106 21 22 AC-5 CLASSROOM 113 12 12" 2,600 2 20 23 24 20 2 2,600 12" 12 AC-3 CLASSROOM 107 25 26 AC-11 CORRIDOR 1ST FLR. 8 3/4" 5,928 2 40 27 48 25 2 4,118 3/4' 10 AC-12 FOOD PREPARATION 29 30 EF-6 12 12" 120 1 15 31 32 SPACE - - - - - 15 1 129 12" 12 EF-4 33 34 SPACE - - - - - 15 1 1 45 12" 12 EF-5 35 36 SPACE - - - - - - - - - - SPACE 37 38 SPACE - - - - - - - - - - SPACE 39 40 SPACE - - - - - - - - SPACE 41 42 SPACE - - - - - TOTAL CONNECTED LOAD: 44,140 VA 123 AMPS FEEDER: 4#1/0 THWN Cu. & 1#6 GND IN 2" C. FEED FROM: PANEL MDP NOTES: 1. CONNECT EMERGENCY FIXTURES TO UNSWITCHED HOT LEG OF CIRCUIT. 2. BREAKER SHALL BE MARKED "SWD' AT THE PANEL FOR UNSWITCHED LIGHTS. ' CONTROLLED BY TIME SWITCH OR LIGHTING CONTACTOR. " GROUND FAULT CIRCUIT INTERRUPTER. SHUTN-TRIP. LARGEST OF NON -COINCIDENT LOADS. TYPE: LOADCENTER MAIN BUS: 125 A SERVICE: POWER & LIGHTING PANEL H2A NEUTRAL: 125 A VOLTAGE: 120/208V, 3P, 4W MAINS: M.L.O. MOUNTING: AS SHOWN I.A.C. 10 K SERIES RATED. AMPS POLE TOTAL VA COND WIRE REMARKS CKT, NO, PHASE CKT. NO, REMARKS WIRE COND TOTAL V,A, POLE AMPS 20 1 720 12" 12 RECEPT. CLASSROOM 201 1 2 LIGHTS CLASSROOMS 201 12 1/2" 868 1 20 20 1 540 1/2" 12 RECEPT. CLASSROOM 201 3 4 LIGHTS CLASSROOMS 202 12 1/2" 868 1 20 20 1 720 1/2' 1 12 RECEPT. CLASSROOM 202 5 6 LIGHTS CLASSROOMS 203 12 1/2" 868 1 1 20 20 1 540 1/2" 12 RECEPT. CLASSROOM 202 7 8 LIGHTS CLASSROOMS 204 12 1/2" 868 1 20 20 1 720 1/2' 12 RECEPT. CLASSROOM 203 9 10 LIGHTS CLASSROOMS 205 12 1/2' 868 1 20 20 1 540 1/2" 12 RECEPT. CLASSROOM 203 11 12 LIGHTS CLASSROOMS 206 12 1/2" 868 1 20 20 1 720 1/2" 12 RECEPT. CLASSROOM 204 13 14 LIGHTS CLASSROOMS 207 12 1/2" 868 1 1 20 20 1 540 1/2" 1 12 RECEPT. CLASSROOM 204 15 16 LIGHTS CLASSROOMS 208 12 1/2' 868 1 20 20 1 720 1/2' 12 RECEPT. CLASSROOM 205 17 18 LIGHTS CLASSROOMS 209 12 1/2" 868 1 20 20 1 540 1/2' 12 RECEPT. CLASSROOM 205 19 20 LIGHTS CLASSROOMS 210 12 1/2" 868 1 20 20 1 720 1/2' 12 RECEPT. CLASSROOM 211 21 22 LIGHTS CLASSROOMS 211 12 1/2' 868 1 20 20 1 540 1/2' 12 1 RECEPT. CLASSROOM 211 23 24 LIGHTS CLASSROOMS 212 12 1/2" 868 1 1 20 20 1 720 12' 12 RECEPT. CLASSROOM 212 25 26 LIGHTS CLASSROOMS 213 12 1/2" 868 1 20 20 1 540 1/2" 12 RECEPT. CLASSROOM 212 27 28 LIGHTS BATHROOMS 12 1/2" 676 1 20 20 1 720 1/2" 12 RECEPT. CLASSROOM 213 29 30 LIGHTS LIBRARY 12 12" 1,348 1 20 20 1 540 112" 12 RECEPT. CLASSROOM 213 31 32 LIGHTS LIBRARY 12 1/2" 1,348 1 20 20 1 720 1/2" 12 1 RECEPT. CLASSROOM 209 33 34 LIGHTS CORRIDOR' 12 1/2" 1,052 1 1 20 20 1 540 1/2" 12 RECEPT. CLASSROOM 209 35 36 LIGHTS CORRIDOR' 12 1/2" 968 1 20 20 1 720 1/2' 12 RECEPT. CLASSROOM 210 37 38 LIGHTS SCIENCE LAB 12 1/2" 666 1 20 20 1 1 1 540 1 1/2" 12 RECEPT. CLASSROOM 210 39 40 LIGHTS LOUNGE 12 1 12' 576 1 20 20 1 1 1 540 1 1/2• 1 12 RECEPT. CORRIDOR 41 42 SPACE - - - - - TOTAL CONNECTED LOAD: 31,058 VA 86 AMPS FEEDER: 4#1 THWN Cu. & 1#6 GND IN 1-1/2' C. FEED FROM: PANEL MDP NOTES: 1. CONNECT EMERGENCY FIXTURES TO UNSWITCHED HOT LEG OF CIRCUIT. 2. BREAKER SHALL BE MARKED "SWD" AT THE PANEL FOR UNSWITCHED LIGHTS. CONTROLLED BY TIME SWITCH OR LIGHTING CONTACTOR. " GROUND FAULT CIRCUIT INTERRUPTER. SHUTN-TRIP. LARGEST OF NON -COINCIDENT LOADS. TYPE: LOADCENTER MAIN BUS: 100 A SERVICE: POWER & LIGHTING PANEL H2B NEUTRAL: 100 A VOLTAGE: 120/208V, 3P, 4W MAINS: M.L.O. MOUNTING: AS SHOWN I.A.C. 10 K SERIES RATED. AMPS POLE TOTAL VA COND WIRE REMARKS CKT, NO, PHASE CKT, NO, REMARKS WIRE COND TOTAL V.A. POLE AMPS 20 1 1,000 1/2" 12 RECEPT. WATER FOUNTAIN " 1 2 REFRIGERATOR 12 1/2' 1,200 1 20 20 1 1,000 1/2" 12 RECEPT. WATER FOUNTAIN " 3 4 RECEPT. APPLIANCE " 12 1/2' 11000 1 20 20 1 900 1/2" 12 RECEPT. LIBRARY 5 6 RECEPT. APPLIANCE " 12 1 1/2- 1,000 1 1 20 20 1 900 1/2" 12 RECEPT. LIBRARY 7 8 RECEPT. APPLIANCE'" 12 1/2' 1,000 1 20 20 1 900 1/2' 12 RECEPT. LIBRARY 9 10 RECEPT. LOUNGE 12 1/2' 1,000 1 20 20 1 900 112" 12 RECEPT. LIBRARY 11 12 RECEPT. LOUNGE 12 1/2" 360 1 20 20 1 1 900 1/2" 12 RECEPT. LIBRARY 13 14 RECEPT. BATHROOM" 12 1/2' 180 1 20 20 1 1 180 12" 12 RECEPT. BATHROOM " 15 16 EXTERIOR LIGHTING' 12 12' 1,5W 2 20 20 1 180 12" 12 RECEPT. BATHROOM " 17 18 20 1 180 12" 12 RECEPT. BATHROOM " 19 20 SPACE - - - - - 20 1 180 12" 12 RECEPT. BATHROOM " 21 22 SPACE - - - - - 20 1 720 1 12" 12 RECEPT. CLASSROOM 206 23 24 SPACE - - - - - 20 1 540 12' 12 RECEPT. CLASSROOM 206 25 26 SPACE - - - - 20 1 720 12" 12 RECEPT. CLASSROOM 207 27 28 SPACE - - - - 20 1 540 12' 12 RECEPT. CLASSROOM 207 29 30 SPACE - - - - - 20 1 720 12' 1 12 RECEPT. CLASSROOM 208 31 32 SPACE - - - - - 20 1 1 540 12- 12 RECEPT. CLASSROOM 208 33 34 SPACE - - - - - 20 1 720 12' 12 RECEPT. CORRIDOR 35 36 SPACE - - - - - 20 1 180 12" 12 JANITOR ROOM " 37 38 SPACE - - - - - - - - - SPACE 39 40 SPACE - - - - - - - - - - SPACE 41 42 SPACE - - - - - TOTAL CONNECTED LOAD: 19,140 VA 53 AMPS FEEDER: 4#3 THWN Cu. & 1#8THWN IN 1-1/4" C. FEED FROM: PANEL MDP NOTES: 1. CONNECT EMERGENCY FIXTURES TO UNSWITCHED HOT LEG OF CIRCUIT. 2. BREAKER SHALL BE MARKED "SWD" AT THE PANEL FOR UNSWITCHED LIGHTS. " CONTROLLED BY TIME SWITCH OR LIGHTING CONTACTOR. GROUND FAULT CIRCUIT INTERRUPTER. SHUTN-TRIP. LARGEST OF NON -COINCIDENT LOADS. TYPE: LOADCENTER MAIN BUS: 200 A SERVICE: POWER & LIGHTING PANEL H2C NEUTRAL: 200 A VOLTAGE: 120/208V, 3P, 4W MAINS: M.L.O. MOUNTING: AS SHOWN I.A.C. 22 K SERIES RATED. AMPS POLE TOTAL VA COND WIRE REMARKS CKT, NO, PHASE CKT, NO, REMARKS WIRE COND TOTAL VA POLE AMPS 15 2 2,080 12" 12 CU-1 CLASSROOM 101 1 2 CU-4 CLASSROOM 108 12 12' 2,080 2 15 3 4 15 2 2,080 1 12" 12 CU-2 CLASSROOM 102 5 6 CU-4 CLASSROOM 109 12 12" 1 2,080 2 15 7 8 15 2 2,080 12" 12 CU-2 CLASSROOM 103 9 10 CU-4 CLASSROOM 110 12 12" 2,080 2 15 11 12 15 2 2,080 12" 12 CU-2 CLASSROOM 104 13 14 CU-4 CLASSROOM 111 12 1 12' 2,080 1 2 15 15 16 15 2 2,080 12' 12 CU-2 CLASSROOM 105 17 18 CU-4 CLASSROOM 112 12 12' 2,080 2 15 19 20 15 2 2,080 12" 12 CU-2 CLASSROOM 106 21 22 CU-4 CLASSROOM 113 12 12" 2,080 2 1 15 23 24 15 2 2,080 12' 12 CU-3 CLASSROOM 107 25 26 CU-11 CORRIDOR 1 ST FLR. 10 3/4' 3,952 2 25 27 28 25 2 3,952 12' 10 CU-12 FOOD PREPARATION 29 30 RTU-2 8 3/4' 8.944 3 45 31 32 45 3 12,384 3/4' 8 ERVA 33 34 35 36 SPACE - - - - - 37 38 SPACE - - - - - - - - SPACE 39 40 SPACE - - - - - - - - - SPACE 41 42 SPACE - - - - - TOTAL CONNECTED LOAD: 56,272 VA 156 AMPS FEEDER: 4#2/0 THWN Cu. & 1#6 THWN IN 2" C, FEED FROM: PANEL MDP NOTES: 1. CONNECT EMERGENCY FIXTURES TO UNSWITCHED HOT LEG OF CIRCUIT. 2. BREAKER SHALL BE MARKED "SWD' AT THE PANEL FOR UNSWITCHED LIGHTS. CONTROLLED BY TIME SWITCH OR LIGHTING CONTACTOR. GROUND FAULT CIRCUIT INTERRUPTER. SHUTN-TRIP. LARGEST OF NON -COINCIDENT LOADS. TYPE: LOADCENTER MAIN BUS: 125 A SERVICE: POWER & LIGHTING PANEL H2D NEUTRAL: 125 A VOLTAGE: 120/208V, 3P, 4W MAINS: M.L.O. MOUNTING: AS SHOWN I.A.C. 10 K SERIES RATED. AMPS POLE TOTAL VA COND WIRE REMARKS CKT. NO. PHASE CKT, NO, REMARKS WIRE COND TOTAL VA. POLE AMPS 25 2 3,952 112" 10 AC-6 CLASSROOM 201'- 1 2 CU-6 CLASSROOM 201"" 12 1/2" 2787 2 20 3 4 25 1 2 1 3,952 1/2" 1 10 AC-7 CLASSROOM 202'- 5 6 CU-7 CLASSROOM 202'- 12 1/2" 2,787 1 2 20 7 8 25 2 3,952 1/2" 10 AC-7 CLASSROOM 203'- 9 10 CU-7 CLASSROOM 203"" 12 1/2" 2,787 2 20 11 12 25 2 3,952 1/2" 10 AC-7 CLASSROOM 204'- 13 14 CU-7 CLASSROOM 204'•'• 12 1/2' 2,787 2 20 15 16 25 1 2 1 3,952 1/2" 10 AC-7 CLASSROOM 205'- 17 18 CU-7 CLASSROOM 205" 12 1/2" 2,787 2 20 19 20 25 1 2 1 3,952 1/2' 10 AC-7 CLASSROOM 206"" 21 22 CU-7 CLASSROOM 206" 12 1/2" 2,787 2 20 23 24 25 2 3,952 1/2" 10 AC-8 CLASSROOM 207"" 25 26 CU-8 CLASSROOM 207"" 12 1/2' 2,787 2 20 27 28 25 2 3,952 1/2" 10 AC-9 CLASSROOM 208"" 29 30 CU-9 CLASSROOM 208"" 12 3/4' 2,787 2 20 31 32 25 2 3,952 1/2" 10 AC-9 CLASSROOM 209"" 33 34 CU-9 CLASSROOM 209"" 12 1/2' 2,787 2 20 35 36 25 2 3,952 1/2" 10 AC-9 CLASSROOM 210"" 37 38 CU-9 CLASSROOM 210"" 12 1/2' 2,787 2 20 39 40 25 1 1 1 350 1 1/2" 12 1 EF-10 41 42 EF-12 12 3/4' 45 1 15 TOTAL CONNECTED LOAD: 39,915 VA 111 AMPS FEEDER: 4#1 THWN Cu. & 1#6 GND IN 1-1/2" C. FEED FROM: PANEL MDP NOTES: 1. CONNECT EMERGENCY FIXTURES TO UNSWITCHED HOT LEG OF CIRCUIT. 2. BREAKER SHALL BE MARKED "SWD" AT THE PANEL FOR UNSWITCHED LIGHTS. CONTROLLED BY TIME SWITCH OR LIGHTING CONTACTOR. GROUND FAULT CIRCUIT INTERRUPTER. •" SHUTN-TRIP. LARGEST OF NON -COINCIDENT LOADS. TYPE: LOADCENTER MAIN BUS: 200 A SERVICE: POWER & LIGHTING PANEL H2E NEUTRAL: 200 A VOLTAGE: 120/208V, 3P, 4W MAINS: M.L.O. MOUNTING: AS SHOWN I.A.C. 42 K SERIES RATED. AMPS POLE TOTAL VA COND WIRE REMARKS CKT- NO, PHASE CKT, NO, REMARKS WIRE COND TOTAL V,A, POLE AMPS 25 2 3,952 12" 10 AC-9 CLASSROOM 211"" 1 2 CU-9 CLASSROOM 211"" 12 1/2" 2787 2 20 3 4 25 1 2 1 3,952 1/2' 1 10 AC-9 CLASSROOM 212"" 5 6 CU-9 CLASSROOM 212•"' 12 1 1/2" 2,787 1 2 20 7 8 25 2 3,952 112" 10 AC-10 CLASSROOM 213"" 9 10 CU-10 CLASSROOM 213"" 12 1/2' 2,787 2 20 11 12 25 2 3,952 12" 10 1 AC-13 CORRIDOR 2ND FLR.*-* 13 14 CU-13 CORRIDOR 2ND FL."" 10 1/2" 4,160 2 30 15 18 100 4 16,370 1-1/4' 3 ELEVATOR "' 17 18 RECEPT. ROOF " 12 12• 540 1 1 20 19 20 RECEPT. ROOF " 12 12" 900 1 20 21 22 RECEPT. ROOF " 12 12" 180 1 20 23 24 SIGN 12 1 12' 1,200 2 20 20 1 100 12" 12 SHUNT TRIP CONTROL 25 26 20 1 800 12" 12 ELEVATOR PIT " 27 28 RTU-1 8 3/4' 7,446 3 40 20 1 200 12' 12 ELEVATOR CABIN " 29 30 20 1 120 12" 12 1 LIGHTS ELEV. ROOM 31 32 20 1 360 12' 12 RECEPT. ELEV. ROOM " 33 34 SPACE - - - - 20 1 120 12' 12 EF-13 35 36 SPACE - - - - - 20 1 4,464 3/4" 8 PANEL H2F 37 38 SPACE - - - - - 39 40 SPACE - - - - - 41 42 SPACE - - - - - TOTAL CONNECTED LOAD: 49,704 VA 138 AMPS FEEDER: 4#2/0 THWN Cu. & 1#6 GND IN 2' C. FEED FROM: PANEL MDP NOTES: 1. CONNECT EMERGENCY FIXTURES TO UNSWITCHED HOT LEG OF CIRCUIT. 2. BREAKER SHALL BE MARKED "SWD" AT THE PANEL FOR UNSWITCHED LIGHTS. CONTROLLED BY TIME SWITCH OR LIGHTING CONTACTOR. •' GROUND FAULT CIRCUIT INTERRUPTER. SHUTN-TRIP. LARGEST OF NON -COINCIDENT LOADS. TYPE: LOADCENTER MAIN BUS: 60 A SERVICE: POWER & LIGHTING PANEL H2F NEUTRAL: 60 A VOLTAGE: 120/208V, 3P, 4W MAINS: M.L.O. MOUNTING: AS SHOWN I.A.C. 10 K SERIES RATED. AMPS POLE TOTAL V.A. COND WIRE REMARKS CKT. NO, PHASE CKT- NO, REMARKS WIRE COND TOTAL VA. POLE AMPS 20 1 180 12' 12 FUME HOOD OUTLET" 1 2 RECEPT. SCIENCE LAB " 12 12' 360 1 20 20 1 864 12" 12 FUME HOOD 3 4 RECEPT. SCIENCE LAB " 12 12' 720 1 20 20 1 1 1 180 12' 12 E.P.O. SWITCH POWER 5 6 RECEPT. SCIENCE LAB '• 12 1 12' 720 1 20 - - - - - SPACE 7 8 RECEPT. SCIENCE LAB " 12 12" 540 1 20 - - - - - SPACE 9 10 RECEPT. SCIENCE LAB 12 12" 180 1 20 - - - - - SPACE 11 12 RECEPT. SCIENCE LAB " 12 12" 720 1 20 - - - - SPACE 13 14 SPACE - - - - - - - - - SPACE 15 16 SPACE - - - - - - - - - SPACE 17 18 SPACE - - - - TOTAL CONNECTED LOAD: 4,464 VA 12 AMPS FEEDER: 4#6 THWN Cu. & 1#8 GND IN 1" C. FEED FROM: PANEL H2E NOTES: 1. CONNECT EMERGENCY FIXTURES TO UNSWITCHED HOT LEG OF CIRCUIT, 2. BREAKER SHALL BE MARKED "SWD" AT THE PANEL FOR UNSWITCHED LIGHTS. CONTROLLED BY TIME SWITCH OR LIGHTING CONTACTOR. "• GROUND FAULT CIRCUIT INTERRUPTER. SHUTN-TRIP. LARGEST OF NON -COINCIDENT LOADS. ;_R%Emos = ALE.JANDRO REMOS R.A. _architects Alejandro Remos R,A. 0011702 -18501 Pines Blvd., Suite 107 ' -PembrLka Fines FL 33029 Tel: (9E4) 442 7122 Fax: (95�4) 442 7190 e-mail: �6nGsbIdg@aol.com SOMERSET CHARTER SCHOOL South Miami -5876 SW 68th Street South Miami, FL 33143 CONSULTANTS: JEANETH ARDILA architect ALBERTO CHINCHILLA architect ALEJANDRO CABAL -CABAL architect MARCEL ADRIAN PEREZ architect -18501 Pines Blvd., Suite 107 Pembroke Pines FL 33029 STRUCTURAL ENG.: EDUARDO GONZALEZ P.E. INC. Structural Engineers State of Florida CA No. 6188 J. Eduardo Gonzilez P.E. -717 Ponce de Le6n Blvd., Suite 335 Coral Gables FL 33134 Tel: (305) 445 5100 Fax: (305) 445 6644 e-mall: eddygon@beusouth.net M.E.P. ENG.: INGEMEL SA LLC. ENGINEERING COMPANY STATE OF FLORIDA CA No. 9113 Pedro Arles P.E.63813 Patricia Morales P.E. 63818 -20871 Johnson Street, Suite 115 Pembroke Pines FL 33029 USA Tel: (954) 318 2284 Fax: (954) 450 7216 e-mal: pedroa@ingemel.com pmorales@Ingemel.com CIVIL ENG.: Consulting Engeneering & Science, Inc. Nelson H. Ortiz P.E. 57556 -10700 North Kendall Drive Suite 400 Miami FL 33176 Tel: (305) 378 55W Fax (305) 279 4553 e-mail: nortiz@CESMIAMI.com LANDSCAPE ARCH.: M. L. A. GROUP INC. Scott McClure RLA 686MS -690 NE 13th Street Suite 105 Fort Lauderdale FL 33304 Tel: (954) 763 4071 Fax (954) 4671688 egnail: mlagroupinc@yehoo.com <,,, SEAL: ``;;.•,,,,1111111►1 t z sees. . P.E. 63818 REVISIONS: Project No: USCB-1 Model File: Drawn by: O.G. Approved by: P.A. Date: 09/08/08 Scale: As Shown Copyright Sheet Title PANEL SCHEDULES Sheet Number E=6 SOMERSET SOUTH MIAMI f- 0