09-49-049GENERAL NOTES: 1. SCOPE OF WORK A CONTRACTOR SHALL PROVIDE ALL EQUIPMENT, MATERIALS, LABOR PERMIT FEES AND INSPECTIONS FOR A COMPLETE WAD INSTALLATION IN ACCORDANCE TO THESE DIAGRAMATICAL DRAWINGS. B. MATERIAL AND WORKMANSHIP SHALL BE IN ACCORDANCE TO THE LATEST EDITION OF THE FLORIDA BUILDING CODE, AND ALL LOCAL CODES AND ORDINANCES C. CONTRACTOR SHALL BASE HIS BID AFTER FAMILIARONG HIMSELF WITH ALL EXISTING ASBUILT CONDITIONS. D. CONTRACTOR SHALL OBTAIN APPROVAL OF SHOP DRAWINGS, SUBMITTALS OF MATERIAL AND EQUIPMENT TO SUBSTITUTE BASIS OF DESIGN EQUIPMENT AND MATERIALS NOTED ON THESE DRAWINGS TEN DAYS PRIOR TO BID DATE. AFTER THIS DATE NO SUBSTITUTIONS SHALL BE ADMITTED. 2. THE DRAWINGS ARE GENERALLY DIAGRAMMATIC, THEY DO NOT SHOW EVERY BEND, OFFSET, ELBOW OR OTHER FITTINGS WHICH MAY BE REQUIRED FOR THE INSTALLATION IN THE SPACE ALLOCATED, OR FOR COORDINATION WITH OTHER TRADES. 3. CONTRACTOR SHALL VERIFY ALL EQUIPMENT, DUCTWORK, DIFFUSERS AND GRILLES TO WORK AND FIT PROPERLY WITH ALL OTHER TRADES AND ASSURE THAT THESE ITEMS DO NOT CONFLICT WITH OTHER TRADES AND WITH ELECTRICAL FIXTURE LOCATIONS. 4. DRAWINGS ARE NOT TO BE SCALED. UNLESS SPECIFIC DIMENSIONS ARE SHOWN, THE ARCHITECTURAL ANDIOR STRUCTURAL DRAWINGS, AND SITE CONDITIONS SHALL GOVERN EXACT LOCATION OF MECHANICAL EQUIPMENT AND APPURTENANCES 5. VERIFY EXACT ROUTING OF DUCTWORK AND CONDENSATE DRAINS WITH STRUCTURAL ELEMENTS LOCATION AND SIZE OF ALL SLEEVES THROUGH STRUCTURAL ELEMENTS SHALL BE SUBMITTED TO ARCHITECT FOR APPROVAL PRIOR TO EXECUTION. 6, CONTRACTOR SHALL TEST AND BALANCE ALL THE HVAC SYSTEMS, AND ADJUST ALL CONTROLS AND EQUIPMENT FOR PROPER OPERATION. TEST & BALANCE SHALL BE DONE IN ACCORDANCE WITH SECTION 13-410.1 ABC.4 OF THE FLORIDA BUILDING CODE. 7. COORDINATE EXACT LOCATION OF ALL SUPPLY & RETURN AIR CEILING DEVICES WITH ARCHITECTURAL CEILING GRID & LIGHT FIXTURE LOCATIONS, 8. EQUIPMENT SHALL HAVE CAPACITIES REQUIRED TO OBTAIN A SUITABLE OPERATING BALANCE BETWEEN ASSOCIATED ITEMS OF EQUIPMENT All DAMPER & CONTROLS SHALL BE ADJUSTED TO OBTAIN THE REQUIRED CAPACITIES UNDER ACTUAL OPERATING CONDITIONS OF EACH SYSTEM AS INSTALLED, OPERATING POWER REQUIREMENTS FOR EACH ITEM OF EQUIPMENT SHALL NOT EXCEED THE RATED MOTOR HORSEPOWER, 9. CONSTRUCT DUCTWORK FROM ONE AND ONE HALF INCH FIBERGLASS DUCTBOARD (R=6.5) FOR ALL INDOOR AIR CONDITIONED SUPPLY AND RETURN DUCTWORK SHEET METAL DUCTS SHALL BE USED FOR EXHAUST, AND NON -CONDITIONED OUTSIDE AIR INTAKE. FABRICATE, SEAT. AND INSTALL PER LATEST SMACNA LOW VELOCITY DUCT MANUAL RECOMMENDATIONS. SIZES NOTED ARE CLEAR INSIDE DIMENSIONS. PROVIDE AIR VOLUME EXTRACTORS, SPUTTER DAMPERS OR ADJUSTABLE TURNING VANES AT ALL BRANCH TAKE -OFFS AS REQUIRED FOR PROPER AIR BALANCING. FLEXIBLE DUCTWORK SHALL BE THERMAFLEX MODEL MAC. UL 181 CLASS 1 AIR DUCT OR SIMILAR 10. COOLING SYSTEMS ARE DESIGNED FOR 757 DB INSIDE CONDITIONS WITH OUTSIDE TEMPERATURE OF 917 DB,TT"F INS. HEATING IS DESIGNED TO MAINTAIN MINIMUM INSIDE TEMPERATURES OF 72'F IDS WITH AN OUTSIDE TEMPERATURE OF 48'F DB 11. AIR DISTRIBUTION DEVICES SHALL BE CONSTRUCTED OF ALUMINUM, AS MANUFACTURED BY METALAIRE, OR SIMILAR, ALL WITH OPPOSED BLADE DAMPER WHERE APPLICABLE AND TR TRANSITION WHERE INDICATED. ALL GRILLAGE SHALL BE PAINTED OF SAME COLOR OF THE CEILING OR DOOR IN WHICH IT IS LOCATED AND ALL SCREWS SHALL BE OF THE COUNTERSUNK TYPE ALSO PAINTED AS GRILLAGE. 12. PROVIDE ACCESS PANELS IN ALL WALL AND CEILING FOR ALL VALVES, DAMPERS, CONTROL DEVICES, ETC. ACCES PANELS SHALL BE MILCOR FLUSH TYPE, MINIMUM OF 24'SQC UNLESS NOTED OTHERWISE. 13 THE WORD'PROVIDE' MEANS TO SUPPLY AND INSTALL. 14. AIR COOLED CONDENSING UNITS TO BE AS SCHEDULED. PROVIDE EACH UNIT WITH ANTI -CYCLING DEVICE, HIGH AND LOW PRESSURE CONTROLLERS, AND FILTER DRYER 15 INSULATE REFRIGERANT SUCTION PIPE WITH 1,2 INCH THICK ARMAFIEX. FINISH INSULATION EXPOSED TO WEATHER WITH TWO COATS OF GLASSFAB AND MASTIC. 18, COORDINATE ALL WORK WITH OTHER TRADES INVOLVED THIS INCLUDES WALL AND ROOF PENETRATIONS, REQUIRED ELECTRICAL SERVICE AND CONTROL WIRING. PLUMBER IS TO PROVIDE A MINIMUM 1 114INCH CONDENSATE TRAP SEAL, AT EACH UNIT. 17. CONDENSATE PIPING MUST HAVE A MINIMUM PITCH OF 114' PER FOOT AS PER FLORIDA PLUMBING CODE IF NECESSARY CONTRACTOR MUST INSTALL CONDESATE PUMP TO GUARANTEE PROPER CONDESATE DISPOSAL 18 ALL AIR CONDITIONING CONDENSATE DRAIN PIPING SHALL BE SCH 40 PVC, EXCEPT WHEN INSTALLED IN AIR PLENUMS WHERE COPPER TYPE'DWV' OR EQUIVALENT MUST BE USED. INSULATE CONDENSATE PIPING WITH 314' ARMAFLEX PROVIDE TRAP WITH CLEAN OUT AND UNIONS FOR CONDENSATE PIPING. 19 INSULATION A PIPE INSULATION: AIR CONDITIONING CONDENSATE PIPING SHALL BE INSULATED WITH 3/4" RRE RATED FLEXIBLE FOAM INSULATION, FINISHED, WHERE EXPOSED B. FLAME AND SMOKE RATING: ALL INSULATION PRODUCTS AND MATERIALS USED FOR THIS PROJECT SHALL HAVE A MAXIMUM FLAME SPREAD AND SMOKE DEVELOPED RATING OF 2VA RESPECTIVELY IN ACCORDANCE WITH TESTS OUTLINED IN NFPA 255. C. PROVIDE INSULATION PROTECTORS AT HANGERS FOR ALL INSULATED PIPING, GRINNEL, CARPENTER & PETERMAN OR EQUIVALENT. 20. OBTAIN FULL INFORMATION REGARDING PECULIARITIES AND LIMITATIONS OF SPACE AVAILABLE FOR INSTALLATION OF THE EQUIPMENT AND MATERIALS UNDER THIS CONTRACT, AND PROVIDE READY ACCESSIBILITY TO DAMPERS, VALVES AND OTHER APPARATUS, INCLUDING ANY PART OF SYSTEM REQUIRED TO BE REACHED FOR MAINTENANCE AND OPERATIONS. 21. THERMOSTAT SHALL HAVE A MAXIMUM HEATING MODE TEMPERATURE SETTING OF 78'F AND A MINIMUM COOUNG MODE TEMPERATURE SETTING OF 707. IT SHALL BE ADJUSTABLE TO PROVIDE A TEMPERATURE RANGE OF UP TO 10 T BETWEEN FULL HEATING AND FULL COOLING HEATING AND COOLING TO BE NON40NCURRENT. THERMOSTAT TO HAVE REQUIRED STAGES OF COOLING AND HEATING FOR COMPATIBILITY WITH AIR CONDITIONING EQUIPMENT PROVIDED. ALL THERMOSTATS SHALL BE OF THE PROGRAMMABLE TYPE. 22. ALL EQUIPMENT SHALL BE PROVIDED WITH VIBRATION ISOLATORS AND INSTALLED AS RECOMMENDED BY EQUIPMENT MANUFACTURER 23. PROVIDE NEW FILTERS FOR ALL AIR CONDITIONING AND VENTILATING EQUIPMENT BEFORE STARTING THEM. THESE FILTERS MUST ALSO BE REPLACED PRIOR TO FINAL ACCEPTANCE BY OWNER 24 ALL CONDENSING UNITS SHALL BE PROPERLY INSTALLED ACCORDING TO THE LATEST EDITION OF THE FLORIDA BUILDING CODE. 25. INSTALL REMOTE TEST STATION FOR DUCT MOUNTED SMOKE DETECTOR RTtl2 AND ERV•1. TEST STATION MUST BE MOUNTED IN A VISIBLE LOCATION AND MUST BE MOUNTED 4'-V A.F.F. 28. INSTALL ACCESS DOOR IN SUPPLY DUCT FOR ACCESS, CLEANING AND INSPECTION OF SMOKE DETECTOR 27, OUTDOOR AIR QUALITY PRECAUTIONS. A THE CONTRACTOR SMALL ALLOW FOR NECESSARY PRECAUTIONS DURING CONSTRUCTION AND THEREAFTER FOR THE INSTALLATION AND HANDLING OF REFRIGERANTS ALL WORK ASSOCIATED WITH THE REFRIGERATION SYSTEM AND REFRIGERATION HANDLING SHALL BE IN ACCORDANCE WITH ASHRAE 15.2007. THE CONTRACTOR SHALL PREPARE WRITTEN DIRECTIONS BY WHICH THE BUILDING OWNER OR ITS REPRESENTATIVE WILL BE ABLE TO HANDLE REFRIGERANT IN A SAFE AND APPROVED MANNER 28. VERIFY ALL VOLTAGES WITH ELECTRICAL CONTRACTOR BEFORE ORDERING ANY EQUIPMENT. 29. FIRE/SMOKE DAMPERS, AS APPROVED BY LOCAL GOVERNING AUTHORITIES, SHALL BE INSTALLED IN ALL DUCTWORK PASSING THRU A FLOOR, ROOF, FIRE PARTITION OR FIRE WALL (PROVIDE ACCESS) REQUIRED BY BUILDING CODES 30. ALL DUCT AND PIPE PENETRATIONS OF EXISTING FIRE RATED PARTITIONS SHALL BE SEALED WITH APPROVED FIRE RATED SEALANT TO MAINTAIN THE INTEGRITY OF THE SYSTEM. 31. CONTRACTOR SHALL FURNISH THE OWNER WITH ALL OPERATING MANUALS AND MAINTENANCE INSTRUCTIONS FOR EQUIPMENT INSTALLED. MANUALS SHALL BE BOUNDED IN THREE RING LOOSE LEAVE BINDERS AND INDEX BY PRODUCT TYPE. ALSO A SECTION WITHIN THE MANUAL SHALL BE INDEX WITH NAME, TELEPHONE NUMBER AND ADDRESS OF ALL LOCAL SUPPUERS OF ALL MATERIAL AND EQUIPMENT INSTALLED TOGETHER NTH NAME, TELEPHONE AND ADDRESS OF ALL CONTRACTORS OF THE PROJECT. 32. CONTRACTOR SHALL GUARANTEE ALL WORK INSTALLED UNDER THE CONTRACT TO BE FREE FROM DEFECTIVE WORKMANSHIP, AND MATERIALS, USUAL WEAR EXPECTED, AND SHOULD ANY SUCH DEFECTS DEVELOP WITHIN A PERIOD OF ONE YEAR AFTER ACCEPTANCE OF THE BUILDING BY THE OWNER CONTRACTOR SHALL REPAIR AND/OR REPLACE ANY DEFECTIVE ITEMS AND ALL DAMAGE RESULTING FROM FAILURE OF THESE ITEMS, AT NO EXPENSE WHATSOEVER TO THE OWNER COMPRESSOR SHALL CARRY 5 YEAR FACTORY WARRANTY. 33. CONTRACTOR SHALL PROVIDE 3 SETS OF SHOP DRAWINGS, SUBMITTALS FOR ALL MATERIAL AND EQUIPMENT TO BE USED IN THIS PROJECT FOR APPROVAL BY ARCHITECTIENGINEER 34. CONTRACTOR SHALL MAINTAIN A SET OF REPRODUCIBLE SEPIA DRAWINGS SHOWING AS BUILT CONDITIONS AS THEY OCCUR COMPLETE SET OF ELECTRONIC (CAD) AS -BUILT REPRODUCIBLE DRAWINGS SHALL BE SUBMITTED BY THE CONTRACTOR TO THE ARCHITECT/ENGINEER PRIOR TO FINAL ACCEPTANCE OF INSTALLATION. THESE DRAWINGS SHALL HAVE ALL INSTALLATIONS REFERENCED BY DIMENSIONS TO A SET REFERENCED POINT OR POINTS. 35. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING HOURS OF WORK TIME AVAILABLE TO HIM WITH LANDLORDMNDLORDS REPRESENTATIVE ONE (1) COAT OF EPDXY BASED ADHESIVE BONDING AGENT BETWEEN NEW AND EXISTING ESCUTCHEON PLATE ON ONE OR BOTH SIDES WHERE PIPING IS EXPOSED (TYPICAL) METAL JACKETING (WEATHERPROOF) WATERPROOF CAULK (TYPICAL) PIPE SLEEVE FOR NEW CONCRETE OR CMU WALLS OR CORE DRILL FOR EXISTING CONCRETE WALLS - NEW OR EXISTING POURED CONCRETE OR NEW CMU WALL DETAIL - PIPE SLEEVE STEEL FACTORY FABRICATED 14" HIGH ROOF CURB ANCHORED TO STEEL JOIST CONC. PC -JOIST CUT OPENING IN EXISTING CMU WALL LARGER THAN SLEEVE AND FORM & FILL ? WITH EXPANSIVE TYPE GROUT L EXISTING CMU WALL ANCHOR LUGS (MINIMUM 3 REQUIRED) -• PIPE SLEEVE PIPE INSULATION (WHERE REQUIRED) • • INTERIOR • ANCHOR LUGS r 4'- a• •'�' (MINIMUM 3 REQUIRED) f, •. . 4 •, '� 4.. NOTE: -� 1. FOR EXTERIOR WALLS ABOVE GRADE ONLY WEATHER PROOF METAL COVER-% NOT TO SCALE #10 TEK SCREWS -1• LONG @ 12 IN. ON CENTERS ON ALL FOUR SIDES n 11 I u _ .... . 7.77A: .:..:...:. . ... •• X 4• X 141 ALL 111s01)D CMINM Wr 44 it#J ISOLTS, eY N1Te 4 rL4�a1e ROOFTOP UNIT CURB MOUNTING DETAIL NOT TO SCALE DELETED 70 A MOUNTING ANGLES FASTENED TO SLEEVE AT e" O C (MIN 2 CONNECTIONS ON FIRE RATED WALL EACH SIDE) ;; 1l4"CLEARANCE PER FOOT B BREAKAWAY CONNECTION - ANGLE SIZE & SLEEVE AS PER SMACNA STANDARDS '. -1 C E --D TYPE B' FIRE DAMPER DUCT W1 UL RATING & STAMP DI F MANUFACTURER'S SLEEVE H FULLY HINGED GASKETED V ACCESS DOOR IN DUCT- Ja Ir X 12" UNLESS NOTED OTHERWISE- LABEL'FIRE 6• MAX. ON ALL SIDES DAMPER' EXTERNAL INSULATION TO EXTEND OVER SLEEVE AFTER INSPECTION OF DAMPER INSTALLATION FIRE DAMPER INSTALLATION -- TYP. DETAIL NOTES 1: NOT TO SCALE ACCESS DOOR SHALL BE LOCATED ON SIDE OR BOTTOM OF DUCT AS APPROPRIATE TO ALLOW RESETTING OF DAMPER LINK FIRE DAMPERS SHALL BE RUSKIN IBD20 STYLE W OR APPROVED EQUIVALENT. (A) Retaining Angles: Minimum 1Y2" x 1Y2" x 0.054 (16 ga.) Retaining angles must overlap structure opening 1" minimum and cover comers of openings as shown. (B) Clearance: Ye" Per Linear Foot II++ Both Dimensions. (C) Steel Sleeve. (D) Approved Fire Damper (courtain or blade type). (E) Secure Retaining Angles to Sleeve Only On 8' Centers With: 1. Y2" long Welds Or 2. Y," Bolts and Nuts, Or 3. No. 10 Steel Screws, Or 4. Minjmun Yle' Steel Rivets. (F) Secure Damper to Sleeve on 8" Center With: 1. X" long Welds Or 2. Y.' Batts and Nuts, Or 3. No. 10 Steel Screws, Or 4. Mjnimun Me" Steel Rivets. (G) Conned Dud to Sleeve. (H) Install access door. VERTICAL AND HORIZONTAL POSITION ARE SIMILAR GENERAL NOTES: 1. FIRE DAMPER SLEEVE CLEARENCE WITHIN WALL OPENING Clearance requirements for damper sleeves within a wall opentnngs are based on Y" per foot of Width (or height) unless other Wise stated In the listing of the assembly. The sleeve may rest on the bottom of the opening, and need not be centered. (Fractional dimensions shall be taken as the next largest foot). The sleeve is retained In the wall opening by the use of steel retaining angles (A). These must over -lap the edge of the framing by a minimum of one (1) Inch over and beyond all material in the opening. This means that the minimum width of the retaining angle would be 1%" ( good practice calls for an additional safety factor by making the angle in this case 1 V22" wide). The dimensions required for the opening shall be those remaining after the opening has been framed and fire resistive materials provided where required. The fire resistive material shall be equal to the requirements for fire resistive material used in the constructed wall so that a continuous rating exists at the wall penetration. The contractor erecting the wall Is responsible for providing the fire resistive material and correct size openings to achieve the required clearance. 2. MANUFACTURERS' INSTALLATIONS DETAILS The fire damper manufacturers' Installation details and Instruction as tested and approved by UL must be used In lieu of the above details where applicable. HANGERS MUST NOT DEFORM DUCT SHAPE -HANCM RODS WRFS SCREWS 1" MIN. SCREWS OMITTED I HANGER ONE HALF -ROUND MAY BE USED LOOPS LOAD RATED IF DUCT SHAPE IS MAINTAINED FASTENERS BAND OF SA AS HANGER 2e DIA. 5O" DIA. MAX STRAP HANGERS MAX UPPER AND LOWER HANGER ATTACHMENTS AND DEVICES STRAPS STRAP OR ANGLE STRAP HANGER HANGED STRAPS SCREWS MAY BE F- MIN. OMITTED IF HANGER N. LOOPS TRAPEZE HANGER BAND OF SAME SIZE AS HANGER STRAP TRAPS `SIZE BOLT(S) FOR LOAD NOTES: O STRAPS ARE GALVANIZED STEEL, RODS ARE UNCOATED OR GALVANIZED STEEL Q SIZE BOLTS AND HANGERS IN ACCORDANCE TO SMACNA DUCT CONSTRUCTION STANDARS. LOAD RATED FASTENERS 36" DIA MAX. 24' DIA. MAX. MINIMUM HANGER SIZES FOR ROUND DUCT Dia. Maximum wire Dia. Rod Strap Spacing 1010 12' One 12ga. 1/4' 1"x22ga. 11'-18' 0 12' Two 12 ga. or One 8 ga. 114" 1 • x 22 ga. RECTANGULAR DUCT HANGERS MINIMUM SIZE MAXIMUM PAIR AT 8 FT SPACING PAIR AT 5 FT SPACING PAIR AT 4 FT SPACING HALF OF STRAP WIRE/ROD STRAP WIRE/ROD STRAP WIRE/ROD DUCT PERIMETER P/2. 30" 1• x 22 ga. 10 ga. 1• x 22 ga. 12 ga. 1' x 22 ga. 12 ga. P/2 = 72" 1' x 20 ga. 1 /4' 1" x 22 ga. 1 /4' 1' x 22 ga. 1 /4' DUCT HANGERS DETAIL S STRUCTURAL. CHANNEL 45' TAKEOFF BRANCH DUCT TAKE -OFF DETAIL r•� r •� r r uasllljjjjj� MIN. 2 HINGES AND 2 LATCHES NOT TO SCALE METAL MAIN SUPPLY TRUNK TYPICAL. TRANSITION MAX W ANGLE VOLUME DAMPER W/ LOCKING DEVICE (LOW PRESSURE ONLY) DUCT MOUNTED ACCESS DOOR NNOT TO SCALE NOT TO SCALE NOT TO SCALE 3/8" X 2 X3/4- RED HEAD BOLTS WITH 2-1/2' MINIMUM EMBEDMENT (MECHANICAL CONTRACTOR TO COORDINATE THIS TYPE OF ANCHORING WITH STRUCTURAL ENGINEER PRIOR TO ANY WORK) r CONCRETE SLAB 4, ''a .1 d •a , I d w d �. 4 1/2" HANGER ROD (TYP OF 4) SUPPLY OPENING STEEL CHANNEL MINIMUM OF 12 GAUGE AHU SUPPORT HANGING DETAIL ANCHORING DETAILS FOR UNIT MOUNTING I' THREADED ROD VIBRATION WATOR (TYP.) AT EACH MOUNTING POINT STEEL ANGLE ANGLE CUP SECURE TO DRAIN PAN SPRING ISOLATOR BOLT WITH WASHER AND NUT DRAIN PAN NOT TO SCALE NOTE: DRAIN PAN SHALL BE A MINIMUM OF i-1/2- DEEP AND 3 INCHES LARGER THAN THE UNIT IN WIDTH AND LENGTT ON ALL SIDES AND SHALL BE CONSTRUCTED OF NOT LESS THAN 24 GAUGE GALVANIZED SHEET METAL WATERTIGHT OF CORROSION RESISTANT MATERIAL TYPICAL AIR HANDLING UNIT MOUNTING DETAIL ANCHOR CONCRETE ANCHORS A•R HANDUNG UNIT (MOUNT AS BLE) CH POSSI FURIG ERATION LINES CONDENSATE DRAIN UNE AND TRAP (SEE PM. DWGS.) NOT TO SCALE NOT TO SCALE UNION (TYP) PERFORATED � CAP I� I -FLOAT SWITCH WIRED IN SERIES WITH T'STAT CIRCUIT TO SHUT OFF SLOPE 7:: AUXILIARY DRAIN PAN (GALVANIZED UNIT IN CASE OF AN OVERFILL TO 1/8- / FT ! SHEET 18 GA.) 1 1/2- DEEP AND 3- DRAIN PAN. / LARGER THAN THE UNIT IN WiDTH & LENGTH. P-TRAP (3- WATER SEAL) NOTE: INSULATE DRAIN PAN WITH 1/2- THICK FIBERGLASS BLANKET WITH VAPOR BARRIER OR SHEET FOAMED PLASTIC INSULATION WITH APPROVED FIRE RATING ON OUTSIDE SURFACE ONLY AHU UNIT DRAIN PAN AND CONDENSATE TRAP DETAIL NOT TO SCALE _ *�REMOS -ALEJAKCHO REMOS R.A. 1. _a- r =c M:t a =c t s Alejandro Ramos R.A" 0011702 -18501 Pines Blvd., Suite 107 Per:ltroke PincsFL 33029 Tel: (954) 442 4122 1 F6x:(954) 442 2190 _ e-ma.".:-remos=w-,i;aol.Lom SOMERSET CHARTER SCHOOL no South Miami -5876 SW 68th Street South Miami, FL 33143 CONSULTANTS: JEANETH ARDILA architect ALBERTO CHINCHILLA architect ALEJANDRO CABAL -CABAL architect MARCEL ADRIAN PEREZ architect -18501 Pines Blvd., Suite 107 Pembroke Pines FL 33029 STRUCTURAL ENG.: EDUARDO GONZALEZ P.E. INC. Structural Engineers State of Florida CA No. 6188 J. Eduardo Gonzblez P.E. -717 Ponce de Le6n Blvd., Suite 335 Coral Gables FL 33134 Tel: (305) 445 5100 Fax: (305) 445 6644 e-mail: eddygon@be9south.net M.E.P. ENG.: INGEMEL SA LLC. ENGINEERING COMPANY STATE OF FLORIDA CA No. 9113 Pedro Arles P.E. 63813 Patricia Morales P.E. 63818 -20871 Johnson Street, Suite 115 Pembroke Pines FL 33029 USA Tel: (954) 318 2264 Fex: (954) 450 7216 e-mail: pedroa@ingemel.com pmorales@ingemel.com CIVIL ENG.: Consulting Engineering & Science, Inc. Nelson H. Ortiz P.E. 57558 -10700 North Kendall Drive Suite 400 Miami FL 33176 Tel: (305) 378 5555 Fax: (305) 279 4553 e-mail: nortiz@CESMIAMI.com LANDSCAPE ARCH.: M. L. A. GROUP INC. Scott McClure RLA SBM95 -690 NE 13th Street Suite 105 Fort Lauderdale FL 33304 Tel: (954) 763 4071 Fax:(954) 4671688 e-mail: mlegroupinc@yahoo.com SEAL: M r": _J v d i•J Pg P.E. 63818 REVISIONS: Q02 / 20 / o9 As per City Remarks & Owner's Request Project No: USC13-1 Model File: Drawn by: A.R. Approved by: P.M.M Date: 09/08/08 Scale: As Shown Copyright Sheet Title MECHANICAL PLAN -NOTES & DETAILS Sheet Number M=5 SOMERSET SOUTH MIAMI