Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
09-49-046
A/C SPLIT SYSTEM SCHEDULE DESCRIPTION UNITS AC-1/CU-I-TYPE 1 AC-VCU-2-TYPE 2 AC-WCU-3-TYPE 3 AC-4/CU-4-TYPE 4 AC-8/CU-5-TYPE 8 AC-WCU-6-TYPE 6 AC-71CU-7-TYPE 7 AC-S/CU-8-TYPE 8 AC-91CU-9-TYPE 9 AC-IOICU-10-TYPE 10 AC-11/CU-11 AC-12/CU-12 AC-13/CU-13 AREA SERVED - CLASSROOM 101 CLASSROOMS 102.103,104,105,108 CLASSROOM 107 CLASSROOMS 108,109,110,111,112 CLASSROOM 113 CLASSROOM 201 CLASSROOMS 202,203,204.205,208 CLASSROOM 207 CLASSROOMS 208,209,210,211.212 CLASSROOM 213 CORRIDOR 1ST. FLOOR FOOD PREP 1ST, FLOOR CORRIDOR 2ND. FLOOR MANUFACTURER - RHEEM RHEEM RHEEM RHEEM RHEEM RHEEM RHEEM RHEEM RHEEM RHEEM RHEEM RHEEM RHEEM AIR HANDLING UNIT MODEL No. - RHSL-HMIS17JA RHSL-HM1817JA RHSL-HM1817JA RHSL-HMIS17JA RHSL-HM1817JA RHSL-HM2417JA RHSL-HM2417JA RHSL-HM2417JA RHSL-HM2417JA RHSL-HM2417JA RHSL-HM3817JA RHSL-HM3617JA RHSL-HM4221JA CONDENSING UNIT MODEL No. - RANL-018JAZ RANL-018JAZ RANL-018JAZ RANL-018JAZ RANL-018JAZ RANL-024JAZ RANL-024JAZ RANL-024JAZ RANL-024JAZ RANL-024JAZ RANL-036JAZ RANL-036JAZ RANL-042JAZ QUANTITY: - 1.0 6.0 1.0 5.0 1.0 1.0 5.0 1.0 5.0 1.0 1.0 1.0 1.0 COMBINED RATINGS SENSIBLE COOLING CAPACITY BTUMR. 11,258 11,264 10,051 13,464 11,774 15,912 15,116 15,721 16,651 15,199 28,000 27,400 31,500 TOTAL COOLING CAPACITY BTU/HR. 16,988 16,963 14,868 19,163 17,481 22,753 21,957 22,562 23,492 22,046 38,000 35,600 39,300 TOTAL HEATING CAPACITY BTUMR. 3,240 3,207 2,836 3,521 3,560 4,254 4.091 4,271 4.369 4,396 18,300 11,300 15,200 REFRIGERANT TYPE - R-410A R-410A R-410A R410A R-410A R-410A R-410A R-41DA R-410A R-410A R410A R410A R410A ENERGY EFFICIENCY EER/SEER 13.00 SEER 13.00 SEER 13.00 SEER 13.00 SEER 13.00 SEER 1340 SEER 13,00 SEER 13.00 SEER 13.00 SEER 13.00 SEER 13.00 SEER 13.00 SEER 13.00 SEER AIR HANDLING UNIT - AHU DISCHARGE TYPE - HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL TOTAL SUPPLY AIRFLOW CFM 800 600 600 600 600 750 750 750 750 750 1,000 1,100 1.150 OUTDOOR AIR (O.A.) CFM 250 250 210 250 250 300 300 300 300 300 250 200 200 O.A. ENT.CONDITIONS DB / WB (PRECOOLED) 'F 79.70 / 68.00 79.70 I68.00 79.70 / 68.00 79.70 / 68.00 79.70 / 68.00 79.70 / 68.00 79.70 / 68.00 79.70 / 68.00 79.70188.00 79.70 / 68.00 91.00 / 77.00 91.00 / 77.00 91.00 / 77.00 EVAP. ENT. AIR CONDITIONS DS I WB 'F 77.62 / 68.11 77.67 / 66.17 77.39 / 65.91 77.20 / 65.72 77.15 / 65.68 77.17 / 65.70 77.35 I65.86 77.15 / 65.68 77.06 / 65.59 77.03 / 65.57 83.4 / 67.9 79.1 / 66.4 82.5 / 68.8 EST. EXTERNAL STATIC PRESSURE IN. W.G. 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.40 025 0.40 AHU FAN MOTOR HP 1/5 1/5 1/5 1/5 1/5 1/5 1/5 1/5 1/5 1/5 1/3 1/3 1/2 ELECTRICAL CHARACTERISTICS V / Ph 20B V / 10 208V/10 208 V / 10 208V/10 208 V / 10 208 V / 10 208 V / 10 208 V 110 208 V / 10 208 V / 10 208V/10 208V/10 208V/10 ELECTRICAL HEATER SIZE KW 2.25 2.25 2.25 2.25 2.25 3.6 3.6 3.6 3.6 3.6 5.4 3.6 5.4 MINIMUM CIRCUIT AMPACITY (AHU INC, HEATER) AMPS 16.0 16.0 18.0 16.0 18.0 24.0 24.0 24.0 24.0 24.0 36.0 25.0 38.0 MAXIMUM CIRCUIT PROTECTOR (AHU INC HEATER) AMPS 20.0 20.0 20.0 20.0 20.0 25.0 25.0 25.0 25.0 25.0 40.0 30.0 40.0 APROX. UNIT WEIGHT LBS. 85.0 85.0 85.0 85.0 85.0 85.0 85.0 85.0 85.0 85.0 954 95.0 150.0 APROX. UNIT DIMENSIONS (Wx H x D) INCHES 17.5"x42.5"x22" 17.5"x42.5"x22" 17.50x42.5"x22" 17.5"x42,5"x22" 17.5"x 42.5" x 22" 17.5"x42.5"x22" 17. 5" x 4 2.5" x 22" 17.5"x42.5"x22" 17.5"x42.5"x22" 17.5"x42.5"x22" 17.5" x 42.5" x 22" 17.5"x42.5"x22" 21"x50.5"x22" CONDENSING UNIT - CU AMBIENT AIR TEMPERATURE 'F 95.0 95.0 95.0 95.0 95.0 95.0 95.0 95.0 95.0 95.0 954 95.0 95.0 ELECTRICAL CHARACTERISTICS V / Ph 208V/ 10 208 V / 10 208 V 110 208V/10 208 V / 10 208V/10 208V/10 208 V 110 208 V 110 208 V / 10 208 V / 10 208V/10 208 V / 10 COMPRESSOR -RLA AMPS 9.0 9.0 9.0 9.0 9.0 12.8 12.8 12.8 12.8 12.8 17.9 17.9 17.9 FAN MOTOR - FLA AMPS 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.8 0.8 1.2 MINIMUM CIRCUIT AMPACITY (CU) AMPS 12.0 12.0 12.0 12.0 12.0 17.0 17.0 17.0 17.0 17.0 24.0 24.0 24.0 MAXIMUM CIRCUIT PROTECTOR (CU) AMPS 20.0 20.0 20.0 20.0 20.0 25.0 25.0 25.0 25.0 25.0 40.0 40.0 40.0 APROX. UNIT WEIGHT LBS, 130.0 130.0 130.0 130.0 130.0 140.0 140.0 140.0 140.0 140.0 205.0 205.0 205.0 APROX. UNIT DIMENSIONS (W x L x H) INCHES 24"x36"x19" 24"x38"x19" 24"x38"x19" 24"x36"x19" 24"x36"x19" 28"x41"x19" 28"x41"x19" 28"x41"x19" 2B"x41"x19" 28"x41"x19" 32"x45"x25" 32"x45"x25" 32"x45"x25" ACCESORIES LIQUID LINE SIZE (AS PER MFGR.RECOM.) IN. O.D. 3/8' 3/8" 3/8" 318" 3/8" 3/8" 3/8" 3/8" 31V 318" 3/8" 318" 3/8" SUCTION LINE SIZE (AS PER MFGR. RECOM.) IN, O.D. 3/4' 3/4" 3/4" 3/4" 3/4' 3/4' 3/4" 314" 3/4" 314" 718" 7/8" 7/8" EXTERNAL FILTER RACK YES / NO YES YES YES YES YES YES YES YES YES YES YES YES YES FILTER TYPE - 1" THROWAWAY 1" THROWAWAY 1" THROWAWAY 1" THROWAWAY 1" THROWAWAY 1" THROWAWAY 1"THROWAWAY 1" THROWAWAY 1" THROWAWAY 1" THROWAWAY 1" THROWAWAY 1" THROWAWAY 1" THROWAWAY PROGRAMMABLE THERMOSTAT YES / NO COOL I HEAT COOL / HEAT COOL / HEAT COOL / HEAT COOL / HEAT COOL I HEAT COOL / HEAT COOL 1 HEAT COOL /HEAT COOL /HEAT COOL /HEAT COOL /HEAT COOL /HEAT NOTES: 1. LOAD FOR CLASSROOM AC UNITS HAS BEEN CALCULATED TAKEN INTO CONSIDERATION THAT THE AOUTDOOR AIR HAS BEEN PRECOOLED BY THE ENERGY RECOVERY UNIT, 2. OUTDOOR AIR ENTERING TEMPERATURES HAVE BEEN TAKEN FROM ENERGY RECOVERY UNIT SELECTION. PLEASE SEE ATTACHED SCHEDULE. 3. LINE SIZES INDICATED ARE FOR BIDDING PURPOSES ONLY AND HAVE BEEN ESTIMATED FOR A MAX. EQUIV. LENGTH OF 100 FEET. THE ACTUAL LINE SIZES SHALL BE ESTABLISHED BY THE CONTRACTOR IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND IN RESPONSE TO FINAL FIELD CONDITIONS. SUCTION LINE LOSS NOT TO EXCEED TWO DEGREES *F WITH MAINTAINING MINIMUM VELOCITY REQUIRED FOR ALL RETURNS. 4. CONTRACTOR MUST VERIFY UNIT CONNECTION (RIGHT OR LEFT HAND AIRFLOW BEFORE ORDERING EQUIPMENT. PACKAGE ROOFTOP UNIT SCHEDULE DESCRIPTION UNITS RTU-1 RTU-2 AREA SERVED - - SCIENCE LAB MEDIA CENTER MANUFACTURER - TRANE RHEEM ROOFTOP UNIT MODEL No. - OSC060A3 RLKS-AD90CL SYSTEM RATINGS SENSIBLE COOLING CAPACITY BTUMR. 27,600 65,400 TOTAL COOLING CAPACITY BTUMR. 53,500 92,300 TOTAL HEATING CAPACITY BTUMR. 26.300 23,700 REFRIGERANT TYPE -- R-22 R-22 ENERGY EFFICIENCY EER/SEER 13.0 SEER 11.3 SEER ROOFTOP UNIT - RTU DISCHARGE TYPE - - VERTICAL VERTICAL TOTAL SUPPLY AIRFLOW CFM Boo 2,600 OUTDOOR AIR CFM 000 620 AMBIENT AIR TEMPERATURE 'F 95.0 95.0 EVAP. ENT. AIR CONDITIONS DS / WB 'F 90.7 / 76.9 80.8 / 67.4 EST. EXTERNAL STATIC PRESSURE IN. W.G. 0.25 0.30 INDOOR FAN MOTOR HP 0.15 (BHP) 2.0 ELECTRICAL CHARACTERISTICS V / Ph / Hz 208V / 3160 208V / 3160 ELECTRICAL HEATER SIZE KW 9.0 7.2 MINIMUM CIRCUIT AMPACITY (INC. HEATER) AMPS 35.8 43.0 MAXIMUM CIRCUIT PROTECTOR (INC. HEATER) AMPS 40.0 50.0 APROX. UNIT WEIGHT (INC. CURB) LBS. 1,300 1,210.0 APROX. UNIT DIMENSIONS (W x H x D) INCHES 45" x 61" x 70" 59" x 41'x 94' ACCESORIES FACTORY FABRICATED ROOF CURB / HEIGHT YES / NO / IN. YES / 141N, YES / 14 IN. O/A HOOD WITH FRESH AIR DAMPER / TYPE YES / NO /- YES/MOTORIZED YES / MOTORIZED MODULATING HOT GAS REHEAT YES / NO YES NO STANDALONE CONTROL MODULE YES/NO YES NO SMOKE DETECTOR IN SUPPLY DUCT YES / NO NO YES FILTER TYPE - - 2" PLEATED I'THROWAWAY PROGRAMMABLE THERMOSTAT YES / NO INCLUDED COOL / HEAT NOTES - 1, 2, 3, 5, 6 1, 2, 3, 4, 6 NOTES: 1. RTU UNIT MUST BE FURNISHED WITH FACTORY MOUNTED DISCONNECT SWITCH. 2. RTU UNIT MUST BE PROVIDED WITH INTERNAL SPRING ISOLATION FOR SUPPLY FAN. 3. CONTRACTOR MUST PROVIDE PROPER CLEARANCES AS PER MANUFACTURER'S RECOMMENDATIONS. 4. THERMOSTAT MUST BE PROVIDED WITH PROPER STAGES TO MATCH RTU UNIT. 5. RTU UNIT MUST BE PROVIDED WITH A DEDICATED STANDALONE CONTROL MODULE (bP581) INCLUDING FIVE TEMPERATURE SENSORS AND ONE HUMIDITY SENSOR, 6. SYSTEMS SHAM BE ARI AND UL LISTED, VENTILATION AIR REQUIREMENTS SYSTEM TAG - DESCRIPTION AREA Ft2 HEIGHT Ft OCCUPANCY CLASSIFICATION Table 6-1 OUTDOOR AIR CFM / FL2 VENT. AIR REQ'D CFM VENT. AIR SUPPLIED CFM RTU-1 - SCIENCE LAB - 2ND FLR. SCIENCE LABORATORY 479.6 8.0 EDUCATIONAL SCIENCE LAB. 1.00 479.6 - SCIENCE LAB STORAGE 32.9 8.0 CHEMICAL STORAGE 1.50 49.4 - RTU-1 - REQUIRED EXHAUST 550.0 8.0 -- - 585.2 - EXHAUST HOOD - - - - 529.0 - RTU-1 - REQUIRED OUTDOOR AIR 720.0 JANITOR CLOSET 35.0 8.0 JANITOR CLOSETS 1.00 35.0 40.0 ELECTRICAL ROOM 74.7 11.6 ELECTRICAL ROOM 1.00 74.7 400.0 ELEVATOR ROOM 64.0 11.2 ELEVATORS 1.00 64.0 400.0 ENERGY RECOVERY VENTILATOR SCHEDULE DESCRIPTION UNITS ERV-1 AREA SERVED -- OUTDOOR AIR MANUFACTURER -- GREENHECK ROOFTOP UNIT MODEL No. -- ERV-522H-30-B OUTDOOR AIR PERFORMANCE OUTDOOR AIR VOLUME (AIRFLOW) CFM 7,110 EST. EXTERNAL STATIC PRESSURE IN, W.G. 0.75 OUTDOOR AIR FAN MOTOR HP 5.0 ELECTRICAL CHARACTERISTICS V / Ph / Hz 208V / 3160 EXHAUST AIR PERFORMANCE EXHAUST AIR VOLUME (AIRFLOW) CFM 6,810 EST. EXTERNAL STATIC PRESSURE IN. W.G. 0.50 OUTDOOR AIR FAN MOTOR HP 3.0 ELECTRICAL CHARACTERISTICS V / Ph / Hz 208V / 3 / 60 DESIGN CONDITIONS OUTDOOR CONDITIONS - SUMMER - DB / WB 'F 91.0 / 80.0 OUTDOOR CONDITIONS - WINTER - OB / WB 'F 46.0 / 38,6 INDOOR CONDITIONS - SUMMER - OB / RH • F - % 76.0 / 64.0 INDOOR CONDITIONS - WINTER - DB / RH • F - % 72.0 / 35.0 SUPPLY CONDITIONS SUPPLY CONDITIONS - SUMMER - AIR VOLUME CFM 7.110 SUPPLY CONDITIONS - SUMMER - DB / WB 'F 79.7 / 68.0 SUPPLY CONDITIONS - WINTER - AIR VOLUME CFM 7.110 SUPPLY CONDITIONS - WINTER - OB / WB 'F 65.5 / 52,0 ELECTRICAL CHARACTERISTICS MINIMUM CIRCUIT AMPACITY AMPS 34.4 MAXIMUM CIRCUIT PROTECTOR AMPS 50.0 UNIT CHARACTERISTICS APROX. UNIT WEIGHT (INC. CURB) LBS. 3,300 APROX. UNIT DIMENSIONS (W x H x D) INCHES 84" x 67.5" x 124" ACCESORIES FACTORY FABRICATED ROOF CURB YES I NO YES O/A INTAKE HOOD WITH 2" MESH FILTERS YES I NO YES MOTORIZED OUTDOOR AIR INTAKE DAMPER YES I NO YES EXHAUST HOOD WITH BIRDSCREEN YES I NO YES SMOKE DETECTOR IN SUPPLY DUCT YES I NO YES NOTES: 1. ERV UNIT MUST BE FURNISHED WITH FACTORY MOUNTED DISCONNECT SWITCH. 2. ERV UNIT MUST BE PROVIDED WITH INTERNAL SPRING ISOLATION FOR FANS. 3. ERV EXHAUST HOOD MUST BE PROVIDED WITH INTEGRAL BACKDRAFT DAMPER. 4. CONTRACTOR MUST PROVIDE PROPER CLEARANCES AS PER MANUFACTURERS RECOMMENDATIONS. 5. SYSTEMS SHALL BE ARI AND UL LISTED. HVAC REQUIREMENT SCHEDULE: YES NO DUCT SMOKE DETECTOR X FIRE DAMPER(S) X SMOKE DAMPER(S) X FIRE RATED ENCLOSURE X FIRE RATED ROOF/FLOOR CEILING ASSEMBLY X FIRE STOPPING X SMOKE CONTROL X OUTSIDE AIR CALCULATIONS (ASHRAE 62.1-2007) SYSTEM TAG - DESCRIPTION OCCUPANCY CATEGORY Table 8.1 OCCUPANCY DENSITY AP / 1000 Ft2 OCCUPANCY DENSITY Ft2 / Peopla P90PLE Rp CFM/Pers. Table 6.1 AREA Az Ft2 Re CFM/Ft2 Table 8.1 Table 8 2 Vbz Eq. 6-1 CFM Voz Eq. 6-2 CFM Vot Eq. 6-3 CFM FINAL CIA Req'd CFM FINAL CIA Supplied CFM AC-1 -CLASSROOM TYPE 1 - 1 ST. FLOOR Classrooms (Ages 5-8) 25.00 40.00 18.0 10.00 546.5 0.12 1.0 245.68 245.58 246.68 245.58 250.0 AC-2 - CLASSROOM TYPE 2.1 ST. FLOOR Classrooms (Ages 5 8) 25.00 40.00 18,0 10.00 646.6 0.12 1.0 245.58 245.58 245.58 245.58 250.0 AC-3 - CLASSROOM TYPE 3 - 1 ST. FLOOR Classrooms (Ages 5-8) 25.00 40.00 15.0 10.00 472.0 0.12 1.0 206.64 208.64 206.64 206.64 210.0 AC-4 -CLASSROOM TYPE 4 -1 ST. FLOOR Classrooms (Ages 5.8) 25.00 40.00 1 B.0 10.00 546.6 0.12 1.0 245.58 245.58 245.58 245.68 250.0 AC-5 - CLASSROOM TYPE 5. 1 ST. FLOOR Classrooms (Ages 5-8) 25.00 40.00 1 B.0 10.00 527.E 0.12 1.0 243.30 243.30 243.30 243.30 250.0 AC-6 - CLASSROOM TYPE 6 - 2ND. FLOOR Classrooms (Age 9 Plus) 35.00 28.57 22.0 1 10.00 662.E 0.12 1.0 1 299.50 299,50 1 299.60 299.50 300.0 AC-7 - CLASSROOM TYPE 7 - 2ND. FLOOR Classrooms (Age 9 Plus) 35.00 28.57 22.0 10.00 662.5 0.12 1.0 299.50 299.50 299.50 299.50 300.0 AC-8 - CLASSROOM TYPE 8 - 2ND. FLOOR Classrooms (Age 9 Plus) 35.00 28.57 22.0 10.00 632.5 0.12 1.0 295.90 295.90 295.90 295.90 300.0 AC-9 - CLASSROOM TYPE 9 - 2ND. FLOOR Classrooms (Age 9 Plus) 35.00 28.57 22.0 10.00 662.5 0.12 1.0 299.60 209.50 299.50 299.50 300.0 AC-10 - CLASSROOM TYPE 10 - 2ND. FLOOR Classrooms (Age 9 Plus) 35.00 28.57 22.0 10.00 633.6 0.12 1 1.0 296.02 298.02 296.02 296.02 300.0 AC-11 - OFFICES & CORRIDOR -1ST, FLR OFFICES OFFICE SPACE 5.00 200.00 3.0 5.00 309.0 0.06 1.0 33.54 33.64 33.54 33.54 -- CORRIDOR CORRIDORS - - -- -- 1.620.4 0.06 1.0 97.22 97.22 97.22 97.22 - TOTAL AC-1I-OFFICES & CORRIDOR 1.929.4 130.76 250.0 AC-12 - FOOD PREP. -1ST. FLOOR CAFETERIA 100.0 10.00 4.0 7.6 609.2 0.18 1.0 139.65 139.65 139.65 139.65 200.0 AC-13 - CORRIDOR 2ND FLR. CORRIDORS - - - - 2,228.7 0.06 1.0 133.72 133.72 133.72 133.72 200.0 RTU-1 - SCIENCE LAB - 2ND FLR. SCIENCE LAB. 25.00 40,00 14.0 10.0 550.0 0.18 1.0 239.00 239.0 239.0 239.0 800.0 RTU-2 - MEDIA CENTER 2ND FLR. MEDIA CENTER 1 25.00 40.00 40,00 10.00 1,765.0 0.12 1.0 611.80 611.80 611.80 1 611.80 620.0 NOTES: 1. OCCUPANCY LOAD HAS BEEN PROVIDED BY ARCHITECT. 2. OUTDOOR AIR FOR RTU-1(SCIENCE LAB) HAS BEEN TAKEN FROM EXHAUST HOOD REQUIREMENT. FAN SCHEDULE FAN No. CITY. SERVICE CFM EST. SP MOTOR V I PH / Hz DRIVE FAN TYPE DESIGN BASED ON MODEL No. ACCESORIES NOTES IN. WG. HP / WATTS MANUFACTURER EF-1 6.0 WIC Classroom 5o 0.25" 46 WATTS 115 / 1 / 60 DIRECT CENTRIFUGAL GREENHECK SP-050 A, B, C, E, J 1, 2, 3, 4, 8 EF-2 2.0 VVC list Mr. 5o 0.25" 46 WATTS 115 / 1 /60 DIRECT CENTRIFUGAL GREENHECK SP-050 A, B. C, E 1, 2, 3, 4 EF-3 1.0 Janitor lF 40 0.25" 38 WATTS 115 / 1 /60 DIRECT CENTRIFUGAL GREENHECK SP-B50 A. B, C. E 1, 2, 3 EF-4 1.0 Food Preparat 150 0.25" 129 WATTS 115 / 1 / 60 DIRECT CENTRIFUGAL GREENHECK SP-8150 A, S, C. E, K 1, 2, 3, 5 EF-5 1.0 Coffee Break 1F 70 0,15" 45 WATTS 115 / 1 / 60 DIRECT CENTRIFUGAL GREENHECK SP-870 A. B. C. E 1, 2, 3 EF-6 1.0 Electrical Room 400 0.15" 120 WATTS 115 / 1 /60 DIRECT CENTRIFUGAL GREENHECK CBF-205-OD A. B, C, E,1 1, 2, 3, 7 EF-7 1.0 Janitor2F 40 0.15" 38 WATTS 115 / 1 / 60 DIRECT CENTRIFUGAL GREENHECK SP-B50 A, S. C, E 1, 2, 3 EF-8 1.0 WC Men 2F 200 0.15" 100 WATTS 115 / 1 / 60 DIRECT CENTRIFUGAL GREENHECK CSP-A190 A. B, C. E 1, 2, 3, 4 EF-9 1.0 WC Women 2F 200 0.15" 100 WATTS 115 / 1 / 60 DIRECT CENTRIFUGAL GREENHECK CSP-A190 A. B, C, E 1, 2, 3, 4 EF-10 1.0 Science Lab 800 0.15" 328 WATTS 115 / 1 / 60 DIRECT CENTRIFUGAL GREENHECK CSP-A900 A, B, C. E, F 1.2.3.5.8 EF-11 1.0 WC Lounge 2F 50 0.15" 38 WATTS 11511 / 60 DIRECT CENTRIFUGAL GREENHECK SP-B50 A. B, C. E 1, 2, 3, 4 EF-12 1.0 Lounge 2F 70 0.15" 45 WATTS 115 / 1 / 60 DIRECT CENTRIFUGAL GREENHECK SP-B70 A. B, C, E 1, 2, 3 EF-13 1.0 1 Elevator Room 400 0.15" 120 WATTS 115 / 1 / 60 DIRECT CENTRIFUGAL GREENHECK CBF-205-OD A, B, C, E,1 1, 2, 3, 7 ACCESORIES: NHS: A - BACKDRAFT DAMPER F - SPEED CONTROL 1. VERIFY ELECTRICAL CHARACTERISTICS BEFORE ORDERING ANY EQUIPMENT. B - HANGING KIT G - TRANSFORMER 2. ALL ACCESOMES MUST BE PROVIDED BY MECHANICAL CONTRACTOR C - VIBRATION ISOLATORS H- HUMIDITY SENSOR 3. ALL FANS MUST BE INSTALLED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE. D - GALV. ROOF CURB I - TEMPERATURE CONTROL 4. FAN MUST INTERLOCK WITH LIGHT SWITCH. E - DISCONNECT SWITCH J- TIME DELAY SWITCH 5. FAN MUST INTERLOCK WITH AC OR RTU UNIT SERVING AREA K - FILTER FOR EXHAUST GRILLE 6. FAN MUST INTERLOCK WITH LABORATORY FUME HOOD. OPERATION WILL BE NON -CONCURRENT. 7. FAN MUST ELECTRICALLY INTERLOCK WITH THERMOSTAT. 8. FAN MUST BE PROVIDED WITH TIME DELAY SWITCH. FAN MUST RUN FOR AT LEAST 10 MINUTES AFTER THE LIGHT HAS BEEN TURNED OFF. SUPPLY / RETURN AIR DIFFUSER SCHEDULE TAG NECK SIZE PATTERN MANUFACTURER SERIES DESCRIPTION A 6" x 6" 1 -WAY METALAIRE 5000 6" x 6"- CEILING SUPPLY DIFFUSER WITH VOLUME DAMPER B 6" 0 2-WAY METALAIRE 7600 24" x 24'- PERFORATED CEILING SUPPLY DIFFUSER WITH VOLUME DAMPER C 6" 0 4 - WAY METALAIRE 7$00 24" x 24"- PERFORATED CEILING SUPPLY DIFFUSER WITH VOLUME DAMPER D 8" 0 4 - WAY METALAIRE 7500 24" x 24" - PERFORATED CEILING SUPPLY DIFFUSER WTH VOLUME DAMPER E 1010 4 - WAY METALAIRE 7600 24" x 24"- PERFORATED CEILING SUPPLY DIFFUSER WITH VOLUME DAMPER F 12' 0 4 - WAY METALAIRE 7500 24" x 24"- PERFORATED CEILING SUPPLY DIFFUSER WITH VOLUME DAMPER G 12" x 12" - RUSKIN EME250MO 12" x 12"- HURRICANE APPROVED INTAKE LOUVER WITH BIRDSCREEN 1 24" x 24" - METALAIRE HR 24" x 24"- RETURN DIFFUSER WITH VOLUME DAMPER 2 B" x 10" - METALAIRE CC1 8" x 10" - CUBED CORE CEILING TRANSFER GRILLE WITHOUT DAMPER 3 10" x 10" - METALAIRE CC1 10" x 10"- CUBED CORE CEILING TRANSFER GRILLE WITHOUT DAMPER 4 12" x 12" - METALAIRE CC1 12" x 12"- CUBED CORE CEILING TRANSFER GRILLE WITHOUT DAMPER 5 Iwo - METALAIRE 750OR 24' x 24"- PERFORATED CEILING RETURN DIFFUSER WITH VOLUME DAMPER 6 12" 0 - METALAIRE 750OR 24" x 24"- PERFORATED CEILING RETURN DIFFUSER WTH VOLUME DAMPER 7 14" 0 - METALAIRE 750OR 24" x 24"- PERFORATED CEILING RETURN DIFFUSER WITH VOLUME DAMPER 8 1610 - METALAIRE 750OR 24" x 24"- PERFORATED CEILING RETURN DIFFUSER WITH VOLUME DAMPER 9 12" x 6" - METALAIRE DGDF 12" x 6" - DOOR TRANSFER GRILLE - DOUBLE FLANGE 10 6" x 6" - METALAIRE CC1 6" x 6% CUBED CORE EXHAUST GRILLE WITH VOLUME DAMPER 11 12" x 12" - METALAIRE CC1 12" x 12" - CUBED CORE EXHAUST GRILLE WITH VOLUME DAMPER 12 24" x 14" - METALAIRE CC1 24" x 14" - CUBED CORE CEILING TRANSFER GRILLE WITHOUT DAMPER NOTES: 1. ALL DIFFUSERS, GRILLES AND REGISTERS (SUPPLY, RETURN AND EXHAUST) MUST BE PROVIDED WITH A VOLUME BALANCING DAMPER. BALANCING DAMPER SHALL BE OF THE OPPOSED BLADE WHERE APPLICABLE. 2. ALL DIFFUSER, GRILLES AND REGISTER (SUPPLY AND RETURN) MUST BE PROVIDED WITH TR TRANSITION WHERE REQUIRED (SQUARE TO ROUND TRANSITION). 3. FINISH TO BE SELECTED BY ARCHITECT. 4. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF AIR DISTRIBUTION DEVICES. 5. CONTRACTOR MUST VERIFY MOUNTING SYSTEM (FRAME STYLE), WITH ARCHITECT, FOR ALL DIFFUSERS, GRILLES AND REGISTERS BEFORE ORDERING, GALVANIZED SHEET METAL DUCTWORK SCHEDULE SERVICE DUCT DIMENSION (In) MATERIAL GAGE RECOMMENDED CONSTRUCTION TRANSVERSE JOINTS, BRACING AND REINFORCING INSULATION STEEL U.S GAGE MATERIAL THICKNESS DUCT SLIP OUTDOOR AIR AND EXHAUST AIR UP TO 24 24 24 DRIVE SLIP, MAX. SPACING EIGHT FEET. DUCT WRAP 24 TO 30 24 24 STANDING DRIVE SLIP, MAX. SPACING EIGHT FEET. 31 TO 60 22 22 STANDING S-SLIP, MAX. SPACING FOUR FEET, NOTES: 1. ALL DUCTS, FITTINGS, DAMPERS, ETC., TO BE CONSTRUCTED IN ACCORDANCE WITH LATEST EDITIONS OF ASHRAE & SMACNA CONSTRUCTION DETAILS. 2. ALL LONGITUDINAL SEAMS TO BE PITTSBURGH LOCK WITH SEALANT. 3. ALL INSULATION (INSULATION JACKET AND ADHESIVE, DUCT ADHESIVES, MASTICS, CEMENTS AND TAPING$ SHALL HAVE TEST FIRE AND SMOKE HAZARD RATINGS NOT TO EXCEED FLAME 25 AND SMOKE DEVELOPED OF 50 - TESTS ASTMES4, UL 273,NFPA 255). 4. INSULATION MATERIAL - FIBERGLASS WITH REINFORCED FOIL VAPOR BARRIER-1.5LB. PER CU.FT. DENSITY - MAX. k FACTOR AT 75'F -0.29 - R VALUE-6.0. S. DUCTWORK WALL PENETRATIONS TO BE SURROUNDED BY X IN. RIGID FIBERBOARD SLEEVES. SPACE BETWEEN DUCTS AND SLABS, AND DUCTS AND SLEEVES TO BE PACKED TIGHTLY WITH MINERAL WOOL AND SEALED WITH NON -HARDENING CAULKING COMPOUND. S. ALL DUCTS PENETRATING SLABS OR FIRE WALLS TO BE RPOVIDED WITH APPROVED FIRE DAMPERS. 7. ALL DUCTS TO BE SEALED WITH INDUSTRIAL CAULK CAULK EQUAL OR SIMILAR TO HARDCAST 601 OR GYPSUM BASED TAPE ADHESIVE SIMILAR TO HARDCAST FTA-20, FOR INDOOR USE OR TRA-50 FOR EXTERIOR. NOTES IT IS THE INTENT OF THESE PLANS TO PROVIDE A COMPLETE OPERATING SYSTEM. A/C CONTRACTOR SHALL FURNISH AND INSTALL ALL REQUIRED EQUIPMENTS, MATERIALS, ETC., EXCEPT WHERE SPECIFICALLY NOTED AS BEING FURNISHED BY OTHERS. SHOULD THERE BE ANY QUESTIONS CONCERNING RESPONSIBILITY, THEY SHALL BE SETTLED BEFORE BID SUBMISSION AND CONTRACT SIGNING.- NO EXTRA CHARGES WILL BE ALLOWED. A/C LEGEND n 300 DESIGNATION FOR DIFFUSER LETTER AND CFM Q THERMOSTAT / DUCT SENSOR © HUMIDITY SENSOR SD DUCT MOUNTED SMOKE DETECTOR DUCTWORK 0 FLEXIBLE DUCTWORK REDUCERS AS INDICATED DUCT RISE QN f-JI-41 DUCT DROP ICJ ELBOW WITH TURNING VANES BRANCH DUCT TAKE -OFF --� LINE CONTINUES C- SPLIT DAMPER UC UNDERCUT DOOR 10'3VD`EVD VOLUME DAMPER -EEaFD FIRE DAMPER ® CEILING SUPPLY DIFFUSER ® CEILING SUPPLY DIFFUSER ® RETURN OR EXHAUST AIR GRILLE RETURN OR EXHAUST AIR GRILLE REF EXHAUST FAN �--�-- INTAKE LOUVER AC AIR CONDITIONING UNIT CD CONDENSATE DRAIN CU CONDENSING UNIT FD FIRE DAMPER RTS REMOTE TEST STATION FOR DUCT MOUNTED SMOKE DETECTOR RTU ROOFTOP PACKAGE UNIT l- _ - - nnos AL-EJAI40RO REMOS R.A. - a.rch�t-Acts Alejandro Rernos S.A. 0011702 -18501 Pines Blvd., Suite 107 Pelnoroke Pines FL.-33029 T31: (954) 4427122 - F%x:(951)4427190 - e-mail. remosblagcc aol.com SOMERSET CHARTER SCHOOL South Miami -5876 SW 68th Street South Miami, FL 33143 CONSULTANTS: JEANETH ARDILA architect ALBERTO CHINCHILLA architect ALEJANDRO CABAL -CABAL architect MARCEL ADRIAN PEREZ architect -18501 Pines Blvd., Suite 107 Pembroke Pines FL 33029 STRUCTURAL ENG.: EDUARDO GONZALEZ P.E. INC. Structural Engineers State of Florida CA No. 6188 J. Eduardo Gomfilez P.E. -717 Ponce de L.e6n Blvd., Suite 335 Core] Gables FL 33134 Tel: (305) 445 5100 Fax:(305) 445 W" e-mail: eddygonpbellsouth.net M.E.P. ENG.: INGEMEL SA LLC. ENGINEERING COMPANY STATE OF FLORIDA CA No. 0113 Pedro Arias P.E. $3813 Patricia Morales P.E.8381a -20871 Johnson Street, Suite 115 Pembroke Pines FL 33029 USA Tel: (954) 318 2264 Fax: (954) 450 7216 e-mail: pedroaQingemel.com pmoralesongemal.com CIVIL ENG.: Consulting Engineering & Science, Inc. Nelson H. Ortiz P.E. 57556 -10700 North Kendall Drive Suite 400 Miami FL 33178 Tel: (11M) 378 55M Fax:(305) 279 4553 e-mail: nonizQCESMIAMI.com LANDSCAPE ARCH.: M. L. A. GROUP INC. Scott McClure RLA BOW95 -890 NE 13th Street Suite 105 Fort l eudardals FL 33304 Tel: (954) 783 4071 Fax: (954) 4671688 9-mall: miagroupine0yehoo corn SEAL: ;. � ` Cj '��......, ��, L 2-1 2-4 ( <R4Z�•..•......•''� .. P.E. 63818 REVISIONS: Project No: USCB-1 Model File: Drawn by: A.R. Approved by: P.M.M Date: 09/08/08 Scale: As Shown Copyright Sheet Title MECHANICAL PLAN SCHEDULES 111�\Q' Sheet Number M=4 SOMERSET SOUTH MIAMI h t-