09-49-041J I H G F E D.1 D C B A
I I I i I I I I i I I
I I I I I I I 1 t I I
_I I
1 -- ---+---------------+------ ----- — — ----------r------I------0
ng=
I I I I I I I i \ \ I PROJECTION �
j I I I 6"0 EXHAUST DUCT I 6"0 EXHAUST DUCT 6"0 EXHAUST DUCT I I \ \
UP TO 2ND FLR UP TO 2ND FLR UP TO 2ND FLR \ II �BovE II
e3 1' UC 6"01 UUC 1�" UC 6"01' UUC 1" UC 6"01" UUC I ry A I
390 3 4_ 1 .+ 3 3 +., .+ 3 3 ++
-� + _ _ 350 _ 350 -i-► . 350 t 350 1 ► .-F- 350 350 E — —
I JIL — -Ivn
�•f -- - 11 -- -f -- - - r -_ -_ _ .1 _ . _ _ _-- - -- -1
CLASSROOM \' �+ 4 l 1 E E i _: _. :_ ._. E E
107 E x I �✓ 300 300 t 300 300 `+� 300 \ \
300 6" 4 X 4 4 � � ti 4 4 I 4 —
F _ 10 0 6"10"0 10"0 x x x x x \\ -- -
-�k — 10 -- 0 1U ---- - 6-6-��"0 "0 6" 8" 10" "0'6"t-- ---A�- - - --- - r - - - -- Ib
AC-2 --
-x— - -- x-
-
— •
.--
SA �2 @�2 r2JIL-� E8 CLASSROOM ROOM
STAIRA2 106' 010'x8' "- 108
"010"0 10"0 10"0 0CASSROOM CLASSROOM CLASSROOM CLASSROOM
II SS
81106105 104 103
--- -------
SUPPLY DUCT�FROM ERV-
22"x2o1II1II III III
IIII
I �
I
I
RETURN DUCT
TO ERV-1
I I 26"x16"
I
4 -- —-------4 —
STUDENTS
DROP OFF 1
PORCH '
200
I
I
I I
I �
I I I
L — 1
5 ----------------- I —
I
I
I I
I
1.1 I
I
L
H
UP 1 U 2NU FLK
UP I U LNU t-LK UP TO 2ND FLR i I
' — ' — — — — — — — — — — — — — —I --I
F E D.1 D
TRANSFER
DUCT
12"x8"
101
Al
FIP,,5f F�00P,,, P�AN - AC �AYOUT
NGi i0 XiY.E
J I H G F E D.1 D C B A
I I I I I I I I I I I
I I I I I I I 1 I I I
I I 1 I I I I I \ \ I PROJECTION
I I I I I I 1 I \
I
ABOVE
/ - - - - --- v
_IL _ -
JL CLASSROOM REFRIGERANT LI S TO RUN TIGHT - -
= JL = 107 TO ROOF. SEE M UFACTURER _ ` _ _ �' O
JL RECOMENDATION FOR SIZES.A\\\
- - — 3/8" 0 LIQUID LINE
3/4" 0 SUCTION LI E" REFRIGERANT LINES TO RUN TIGHT --I- --- _ — REFRIGERANT LINE$ TO RUN TI
rTO ROOF. SEE MANUFACTURER _ _ ��
r _ RECOMENDATIONS FOR SIZES, _ __ __ - —
I AC 3 ' ur RECOMENDATIONSTO ROOF. SEE ORSIZESR I
3/8' 0 LIQUID LINE
-.. 3/4" 0 SUCTION LINE _ --- 3/8" 0 LIQUID LINE
I� AC-2 AC-2 - AC 2 AC 2 AG1 -- I 0 SUCTION LIN I I
STAIR 0 1 7/8"
I• --- ---'-- - -� - __. - -
u'' _ 0-- � --�I L t- - ------------- CLASSROOM CLASSROOM
STAIR Y 2 102 101CLASSROOM CLASSROOM CLASSROOM CLASSROOM
1R-—--—-- — -- —,- 106 105 104 103
' I I
'
-- -- - __---- -- - ---- -- -- -- ---- -- - ---- '-- t-- -- -- ' -- '------1 3 )
I
RIGERANT LINES TO RUN TIGHT
REFRIGERANT PIPING TO I �. I REF
I I AC-2-CR-105, AC-2-CR-106 AND TO ROOF. SEE MANUFACTURER _
_ C11 I
AC-3-CR-107 ON 1ST FLOOR
ECOMENDATIONS FOR SIZES.
3/4"/0 SUCTION LINE HALL L 3!8" 0 LIQUID L
J/ \`� 3/4" 0 SUCTION LINE �YtAIN HALL
/ I
I i I I REFRIGERANT LINES TO RUN TIGHT I REFRIGERANT LINES TO RUN TIGHT
_ . 1
TO ROOF. SEE MANUFACTURER_ - TO ROOF. SEE MANUFACTURER _., ' -
RECOMENDATIONS FOR SIZES RECOMENDATIONS FOR SIZS.
I -LIEI -
• 3/8' 0 LIQUID LINE _ 3/8" 0 LIQUID E
314" 0 SUCTION LINE 3/4" 0 SUCTION LINE
1 4 1----------------�- --- ��-�- — -®�-- I -------- `��I------- -- -- -I ---- - - -- ----- I - -q ---- 1 - -- OF'�E ----------{ 4 )
I � STUDENTS
1 DROP OFF I 1 I 1
PORCH STORAGE
j O _O REFRIGERANT PIPING TO I- --
I V CLASSROOM g CLASSROOM CLASSROOM _
i
I .__. _ _ AC-4-CR-108, AND AC-4-CR-10 _
- - - i 108 ON 1ST FLOOR 111 - 113
3/8" 0 LIQUID LINE � - I CLA_ SSROOM_ CLASSROOMREFRIG
-_ - REFRIGERANT PIPIN
3/4" 0 SUCTION LINE 110 GTO
2 RE 0 A C-2-CR-104, RANT PIPING TO112 AR N C-5-CR-1113, AC-2-CR-102,
AC-'-:-1----
REFRIGERANT LINES TO RUN TIGHT i I I �C q AC 4 A y A A
TO ROOF. SEE MANUFACTURER I AC-4-CR-111 ON 1ST FLOO -C- -4 AC-4-CR-112 ON 1ST FLOOR
RECOMENDATIONS FOR SIZES. TO AC-IZ-FOOD PREP -_ CLASSROOM 3/8" 0 LIQUID LINE
AC-1 REFRIGERANT PIPING 3/8" 0 LIQUID LINE
3/8" 0 LIQUID LINE I _--_ _ .ON 1ST FLOOR - ----- 109 - 3/4" 0 SUCTION LINE - - 3/4' 0 SUCTION LINE - -
L — 7/8" 0 SUCTION LINE I 3/8" 0 LIQUID LINE ( i
1
- - - -- 3/4' 0 SUCTION LINE
OFFICE#2
T -
DISTRIBUTION
AREA
-----
6 I -- _ IDUMPSTER -- I ---- ' -----
REFRIGERANT LINES O RUN TIGHT REFRIGERANT IN S T RUN TIGHT
REFRIGERANT LINES TO RUN TIG REFRIGERANT LINES TO RUN TIGHT TO ROOF. SEE MANUFACTURER TO ROOF. SEE A UFA TURER
I I I I TO ROOF. SEE MANUFACTURE F+j TO ROOF. SEE MANUFACTURER I L RECOMENDATIONS FdIR SIZES. LRECOMENDATI N FO SIZES. I I I
RECOMENDATIONS FOR SIZES _ — — — — RECOMENDATIONS FOR SIZES. — _ — — — I_ — _ — — — — — — — _ 3/8' 0 LIQUID LINE 1_ — — — — — — — — — _ 318" 0 LIQUID LI EJ
3/8" 0 LIQUID LIN 3/8' 0 LIQUID LINE REFRIGERANT LINES TO RUN TIGHT 3T4'r0 SUCTION Lli REFRIGERANT LINES TO RUN TIGHT 3/4" 0 SUCTION INE
3/4" 0 SUCTION LIN 3/4" 0 SUCTION LINE TO ROOF. SEE MANUFACTURER TO ROOF. SEE MANUFACTURER
RECOMENDATIONS FOR SIZES. RECOMENDATIONS FOR SIZES.
J 1.1 I H G F 3/8" 0 LIQUID LINE E 3/8' 0 LIQUID LINE D.1 D C B A
3/4' 0 SUCTION LINE 3/4" 0 SUCTION LINE
ffi FIP\5f FLOOP\ PLAN - P\�FP\16�F'\ANT PIPIN6
nor.o x&e
iee ton
I-
ALEJANIDRO REMOS R.A.
ar-chi►e-6ts
Alejandro Rer- a ri.A. 0011702
-18501 Pines Blvd., Suite 107
Pembroke Pines FL 33029
Tel: (3E4) 442 7:E2- - -
Fax' (954) 442 7190 -
e-mail: remosblog@aa.Com
SOMERSET CHARTER
scxooL
South Miami
-5876 SW 68th Street
South Miami, FL 33143
CONSULTANTS:
JEANETH ARDILA
architect
ALBERTO CHINCHILLA
architect
ALEJANDRO CABAL -CABAL
architect
MARCEL ADRIAN PEREZ
architect
-18501 Pines Blvd., Suite 107
Pembroke Pines FL 33029
STRUCTURAL ENG.:
EDUARDO GONZALEZ P.E. INC.
Structural Engineers
State of Florida CA No. 6188
J. Eduardo Gonzilez P.E.
-717 Ponce de Le6n Blvd., Suite 335
Coral Gables FL 33134
Tel: (305) 445 5100
Fax: (305) 445 8844
e-mail: eddygon@bellsouth.net
M.E.P. ENG.:
INGEMEL SA LLC.
ENGINEERING COMPANY
STATE OF FLORIDA CA No. 9113
Pedro Arlas P.E.63813
Patricia Morales P.E. 63018
-20871 Johnson Street, Suite 115
Pembroke Pines FL 33029 USA
Tel: (954) 318 2214
Fax*(954) 450 7218
e-mail: pedroa@ingemel.com
pmorales@ Ingemel.00m
CIVIL ENG.:
Consulting Engineering
& Science, Inc.
Nelson H. Ortiz P.E. 57556
-10700 North Kendall Drive Suite 400
Miami FL 33176
Tel: (305) 378 5555
Fax: (305) 279 4553
e-mail: nonlz@CESMIAMI.com
LANDSCAPE ARCH.:
M. L. A. GROUP INC.
Scott McClure RLA S666895
-690 NE 13th Street Suite 105
Fort Lauderdale FL 33304
Tel: (954) 763 4071
Fax:(954) 4671888
e-mail: miagroupinc@yahoo.com
SEAL:
Cj
.ti
C)
P.E. 63818
REVISIONS:
Project No:
USC13-1
Model File:
Drawn by:
O.G.
Approved by:
P.M.
Date:
09/08/08
Scale:
As Shown
11 Copyright
Sheet Title
FIRST FLOOR
MECHANICAL
PLAN
Sheet Number
SOMERSET SOUTH MIAMI
0