Loading...
09-49-041J I H G F E D.1 D C B A I I I i I I I I i I I I I I I I I I 1 t I I _I I 1 -- ---+---------------+------ ----- — — ----------r------I------0 ng= I I I I I I I i \ \ I PROJECTION � j I I I 6"0 EXHAUST DUCT I 6"0 EXHAUST DUCT 6"0 EXHAUST DUCT I I \ \ UP TO 2ND FLR UP TO 2ND FLR UP TO 2ND FLR \ II �BovE II e3 1' UC 6"01 UUC 1�" UC 6"01' UUC 1" UC 6"01" UUC I ry A I 390 3 4_ 1 .+ 3 3 +., .+ 3 3 ++ -� + _ _ 350 _ 350 -i-► . 350 t 350 1 ► .-F- 350 350 E — — I JIL — -Ivn �•f -- - 11 -- -f -- - - r -_ -_ _ .1 _ . _ _ _-- - -- -1 CLASSROOM \' �+ 4 l 1 E E i _: _. :_ ._. E E 107 E x I �✓ 300 300 t 300 300 `+� 300 \ \ 300 6" 4 X 4 4 � � ti 4 4 I 4 — F _ 10 0 6"10"0 10"0 x x x x x \\ -- - -�k — 10 -- 0 1U ---- - 6-6-��"0 "0 6" 8" 10" "0'6"t-- ---A�- - - --- - r - - - -- Ib AC-2 -- -x— - -- x- - — • .-- SA �2 @�2 r2JIL-� E8 CLASSROOM ROOM STAIRA2 106' 010'x8' "- 108 "010"0 10"0 10"0 0CASSROOM CLASSROOM CLASSROOM CLASSROOM II SS 81106105 104 103 --- ------- SUPPLY DUCT�FROM ERV- 22"x2o1II1II III III IIII I � I I RETURN DUCT TO ERV-1 I I 26"x16" I 4 -- —-------4 — STUDENTS DROP OFF 1 PORCH ' 200 I I I I I � I I I L — 1 5 ----------------- I — I I I I I 1.1 I I L H UP 1 U 2NU FLK UP I U LNU t-LK UP TO 2ND FLR i I ' — ' — — — — — — — — — — — — — —I --I F E D.1 D TRANSFER DUCT 12"x8" 101 Al FIP,,5f F�00P,,, P�AN - AC �AYOUT NGi i0 XiY.E J I H G F E D.1 D C B A I I I I I I I I I I I I I I I I I I 1 I I I I I 1 I I I I I \ \ I PROJECTION I I I I I I 1 I \ I ABOVE / - - - - --- v _IL _ - JL CLASSROOM REFRIGERANT LI S TO RUN TIGHT - - = JL = 107 TO ROOF. SEE M UFACTURER _ ` _ _ �' O JL RECOMENDATION FOR SIZES.A\\\ - - — 3/8" 0 LIQUID LINE 3/4" 0 SUCTION LI E" REFRIGERANT LINES TO RUN TIGHT --I- --- _ — REFRIGERANT LINE$ TO RUN TI rTO ROOF. SEE MANUFACTURER _ _ �� r _ RECOMENDATIONS FOR SIZES, _ __ __ - — I AC 3 ' ur RECOMENDATIONSTO ROOF. SEE ORSIZESR I 3/8' 0 LIQUID LINE -.. 3/4" 0 SUCTION LINE _ --- 3/8" 0 LIQUID LINE I� AC-2 AC-2 - AC 2 AC 2 AG1 -- I 0 SUCTION LIN I I STAIR 0 1 7/8" I• --- ---'-- - -� - __. - - u'' _ 0-- � --�I L t- - ------------- CLASSROOM CLASSROOM STAIR Y 2 102 101CLASSROOM CLASSROOM CLASSROOM CLASSROOM 1R-—--—-- — -- —,- 106 105 104 103 ' I I ' -- -- - __---- -- - ---- -- -- -- ---- -- - ---- '-- t-- -- -- ' -- '------1 3 ) I RIGERANT LINES TO RUN TIGHT REFRIGERANT PIPING TO I �. I REF I I AC-2-CR-105, AC-2-CR-106 AND TO ROOF. SEE MANUFACTURER _ _ C11 I AC-3-CR-107 ON 1ST FLOOR ECOMENDATIONS FOR SIZES. 3/4"/0 SUCTION LINE HALL L 3!8" 0 LIQUID L J/ \`� 3/4" 0 SUCTION LINE �YtAIN HALL / I I i I I REFRIGERANT LINES TO RUN TIGHT I REFRIGERANT LINES TO RUN TIGHT _ . 1 TO ROOF. SEE MANUFACTURER_ - TO ROOF. SEE MANUFACTURER _., ' - RECOMENDATIONS FOR SIZES RECOMENDATIONS FOR SIZS. I -LIEI - • 3/8' 0 LIQUID LINE _ 3/8" 0 LIQUID E 314" 0 SUCTION LINE 3/4" 0 SUCTION LINE 1 4 1----------------�- --- ��-�- — -®�-- I -------- `��I------- -- -- -I ---- - - -- ----- I - -q ---- 1 - -- OF'�E ----------{ 4 ) I � STUDENTS 1 DROP OFF I 1 I 1 PORCH STORAGE j O _O REFRIGERANT PIPING TO I- -- I V CLASSROOM g CLASSROOM CLASSROOM _ i I .__. _ _ AC-4-CR-108, AND AC-4-CR-10 _ - - - i 108 ON 1ST FLOOR 111 - 113 3/8" 0 LIQUID LINE � - I CLA_ SSROOM_ CLASSROOMREFRIG -_ - REFRIGERANT PIPIN 3/4" 0 SUCTION LINE 110 GTO 2 RE 0 A C-2-CR-104, RANT PIPING TO112 AR N C-5-CR-1113, AC-2-CR-102, AC-'-:-1---- REFRIGERANT LINES TO RUN TIGHT i I I �C q AC 4 A y A A TO ROOF. SEE MANUFACTURER I AC-4-CR-111 ON 1ST FLOO -C- -4 AC-4-CR-112 ON 1ST FLOOR RECOMENDATIONS FOR SIZES. TO AC-IZ-FOOD PREP -_ CLASSROOM 3/8" 0 LIQUID LINE AC-1 REFRIGERANT PIPING 3/8" 0 LIQUID LINE 3/8" 0 LIQUID LINE I _--_ _ .ON 1ST FLOOR - ----- 109 - 3/4" 0 SUCTION LINE - - 3/4' 0 SUCTION LINE - - L — 7/8" 0 SUCTION LINE I 3/8" 0 LIQUID LINE ( i 1 - - - -- 3/4' 0 SUCTION LINE OFFICE#2 T - DISTRIBUTION AREA ----- 6 I -- _ IDUMPSTER -- I ---- ' ----- REFRIGERANT LINES O RUN TIGHT REFRIGERANT IN S T RUN TIGHT REFRIGERANT LINES TO RUN TIG REFRIGERANT LINES TO RUN TIGHT TO ROOF. SEE MANUFACTURER TO ROOF. SEE A UFA TURER I I I I TO ROOF. SEE MANUFACTURE F+j TO ROOF. SEE MANUFACTURER I L RECOMENDATIONS FdIR SIZES. LRECOMENDATI N FO SIZES. I I I RECOMENDATIONS FOR SIZES _ — — — — RECOMENDATIONS FOR SIZES. — _ — — — I_ — _ — — — — — — — _ 3/8' 0 LIQUID LINE 1_ — — — — — — — — — _ 318" 0 LIQUID LI EJ 3/8" 0 LIQUID LIN 3/8' 0 LIQUID LINE REFRIGERANT LINES TO RUN TIGHT 3T4'r0 SUCTION Lli REFRIGERANT LINES TO RUN TIGHT 3/4" 0 SUCTION INE 3/4" 0 SUCTION LIN 3/4" 0 SUCTION LINE TO ROOF. SEE MANUFACTURER TO ROOF. SEE MANUFACTURER RECOMENDATIONS FOR SIZES. RECOMENDATIONS FOR SIZES. J 1.1 I H G F 3/8" 0 LIQUID LINE E 3/8' 0 LIQUID LINE D.1 D C B A 3/4' 0 SUCTION LINE 3/4" 0 SUCTION LINE ffi FIP\5f FLOOP\ PLAN - P\�FP\16�F'\ANT PIPIN6 nor.o x&e iee ton I- ALEJANIDRO REMOS R.A. ar-chi►e-6ts Alejandro Rer- a ri.A. 0011702 -18501 Pines Blvd., Suite 107 Pembroke Pines FL 33029 Tel: (3E4) 442 7:E2- - - Fax' (954) 442 7190 - e-mail: remosblog@aa.Com SOMERSET CHARTER scxooL South Miami -5876 SW 68th Street South Miami, FL 33143 CONSULTANTS: JEANETH ARDILA architect ALBERTO CHINCHILLA architect ALEJANDRO CABAL -CABAL architect MARCEL ADRIAN PEREZ architect -18501 Pines Blvd., Suite 107 Pembroke Pines FL 33029 STRUCTURAL ENG.: EDUARDO GONZALEZ P.E. INC. Structural Engineers State of Florida CA No. 6188 J. Eduardo Gonzilez P.E. -717 Ponce de Le6n Blvd., Suite 335 Coral Gables FL 33134 Tel: (305) 445 5100 Fax: (305) 445 8844 e-mail: eddygon@bellsouth.net M.E.P. ENG.: INGEMEL SA LLC. ENGINEERING COMPANY STATE OF FLORIDA CA No. 9113 Pedro Arlas P.E.63813 Patricia Morales P.E. 63018 -20871 Johnson Street, Suite 115 Pembroke Pines FL 33029 USA Tel: (954) 318 2214 Fax*(954) 450 7218 e-mail: pedroa@ingemel.com pmorales@ Ingemel.00m CIVIL ENG.: Consulting Engineering & Science, Inc. Nelson H. Ortiz P.E. 57556 -10700 North Kendall Drive Suite 400 Miami FL 33176 Tel: (305) 378 5555 Fax: (305) 279 4553 e-mail: nonlz@CESMIAMI.com LANDSCAPE ARCH.: M. L. A. GROUP INC. Scott McClure RLA S666895 -690 NE 13th Street Suite 105 Fort Lauderdale FL 33304 Tel: (954) 763 4071 Fax:(954) 4671888 e-mail: miagroupinc@yahoo.com SEAL: Cj .ti C) P.E. 63818 REVISIONS: Project No: USC13-1 Model File: Drawn by: O.G. Approved by: P.M. Date: 09/08/08 Scale: As Shown 11 Copyright Sheet Title FIRST FLOOR MECHANICAL PLAN Sheet Number SOMERSET SOUTH MIAMI 0