09-49-0061. At the completion of any water and sewer job either Donation or Contract, the Contractor shall submit. a. "As -Built" mylar 24"x 36" (min. 4 mil thickness) for each phase. b. Blue be (from mylar) which has been signed and sealed by Registered Surveyor Engineer of Record, and endorsed by the Contractor, (Qty. of prints, as required by the Department.) 2. "As-BuW Format: a. 24"x 36" mylar b. The word "As -Built" in large letters. C. Title block with Department El number and pertinent information, d. Preferred scale to be 1"= 40, horizontally and 1 "= 4' vertically.* e. Street nomenclature. f. Separate water and sewer profile. g. Station main starting with 0 + 00 atpermment reference point (i.e. C, S, etc.) and to run continuously to end of main at center lime of pipe. h. Easements, if any, tied to permanent reference point. i. Identify all control lines (i.e. bldg. line, property he, R/W, etc). j, All "proposed" information to be removed from mylar, leaving only "as -built" information reflected in drawings. 3. Water "As-Builts" must include: a. Plans showing pipe size, material and offset of main, deflections (if any), station of services, hydrants and fittings at the mainline (if perpendicular to it), and at main and end of services if any, other angle, and deflection of pipe, if any. b. Profile showing top of ground and top'of pipe elevations at every 100' station and at any change in grade (with corresponding station), pipe size and pipe materials reference to plan. 4. Sewer "As-Builts" must include: a. Plan showing manhole number, pipe size and pipe material of pipe, deflection, if any (force main only), and location of laterals with reference to manhole, b. Profile showing manhole number (as per plan), rim and invert elevations (if more than one invert, label north, south, etc), and station starting at MO at downstream manhole, 5. Force main "As -Built" same as water main. ` Other scale maybe permitted, but must be approved by the Department prior to preparation of drawings. I T E M ISSUE DATE APPROVED BY S T A N D A R D D E T A I L 11 01/2006 V.E.F. MIAMI•DADE .r _ ' "AS -BUILT" REQUIREMENTS Ar trr"+g1-4--Trrry1trr CROSS I SPEC. I REF. REF. GS 0.5 SHEET 2 OF 2 1. All materials and labor under this pmject shall be in strict accordance Mth the requirements of the Miami -Dade Water and Sewer Department and shall conform to the standards and specifications available and on file with the Department Submit shop drawings for all materials. 2. Cover over water or sewer force mains shall be 4'-0" min. 3. All main he valves shall be installed complete with 10" riser pipes and No. 3 or 53 valve boxes Fire hydrants and service valves shall be installed complete with 6" riser pipes and No. 2 valve boxes. 4, All force main service connections into pressure transmission mains shall have a shut off valve and check valve at the point of entry. 5. All gravity systems shall be constructed in accordance u7th Department standards. 6. All water meters will be installed by the Miami -Dade Water and Sewer Department providing the appropriate charges have been prepaid. 7. Fire hydrant requirements (number and location) shall be as required by bade County Fire Department or the appropriate Fire agency with installation in accordance with Department standards, S. Contractor MUST CALL M-DWASD Inspection Division to arrange for a preconstruction meeting 2 full business days prior to proposed start of construction. Contact One Call Center 48 hrs prior to excavation. 9. Contract Inspector will inspect airy facilities approved by the Department All other requirements of the permitting agency shall be in accordance with their standards and requirements. 10. Wo:k performed under this Project will not be considered as complete until final acceptance of the systetrt by the Department and until the following documents are received and approved by the Department. 1. Easements, if required 2. Contractor's Waiver and Release of Lien, 3. Absolute Bill of Sale. 4 a. Contractor's Letter of Warranty (i.e., Letter Agreement) b. Developeds Contract Bond (i.e,, Contract Agreement), 5. "As -Built" 4 mil mylar 2Vx 36" showing specific locations, depth, etc, of all water and sewer facilities as located by licensed surveyor, along with prints of "as -bunt" which have been signed and scaled by a Registered Surveyor or Engineer ofRecord, and endorsed by the Contractor. (No. of prints; 3-for water, 4-for gravity sewer and 5-for force main or pump station projects), 6. H.R.S. Letter of Release required for all water projects. 11. All new connections from existing Department mains to be made by Department forces ONLY. The Contractor to excavate at required locations, provide and install material with fittings, prior to tap. 12, An approved paving and drainage plan must be submitted to MDWASD for all new subdivisions prior to approval of water and sewer permit plans, upon request 13, Unless otherwise specified, all laps 20 inches and smaller for connections to existing mains will require a tapping sleeve and tapping valve provided and installed by Department forces. Under no circumstances will the Contractor bepermitted to tap existing mains in the size range specified above. I T E M CROSS SPEC. REF.REF. ISSUE DATE APPROVED BY STAN DARD DETAIL G S 17 11/012006 V.E.F. STANDARD REQUIREMENTS .7 MIAMI•DADE WATER AND SEWER 0.5 COMSTRUCTION SHEET 1 OF 2 GENERAL NOTES (NOT A PART OF M-DWASD NOTES OR APPROVAL) 1. ELEVATIONS SHOWN REFER TO THE NATIONAL GEODETIC VERTICAL DATUM (N.G.V.D.). 2• HORIZONTAL AND VERTICAL CONTROL SHALL BE PROVIDED BY THE OWNER'S SURVEYOR. LAYOUT IS THE RESPONSIBILITY OF THE CONTRACTOR. 3. IT IS THE INTENT OF THESE DRAWINGS TO BE IN ACCORDANCE WITH APPLICABLE CODES AND AUTHORITIES HAVING JURISDICTION. ANY DISCREPANCIES BETWEEN THESE DRAWINGS AND APPLICABLE CODES SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE ENGINEER. 4. EXISTING UTILITIES SHOWN ARE BASED ON INFORMATION SUPPLIED BY OTHERS. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO MEET WITH ALL APPLICABLE UTILITY COMPANIES TO VERIFY ALL UNDERGROUND FACILITIES PRIOR TO THE START OF CONSTRUCTION. ALL TRENCH EXCAVATION SHALL PROCEED WITH EXTREME CAUTION AT ALL TIMES. IN THE EVENT THAT EXISTING UTILITIES ARE DAMAGED, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO REPAIR OR REPLACE ALL SUCH DAMAGE. 5. EXISTING GRADES WERE TAKEN FROM THE BEST AVAILABLE DATA AND MAY NOT ACCURATELY REFLECT PRESENT CONDITIONS. CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING HIMSELF WITH CURRENT SITE CONDITIONS, AND SHALL REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO STARTING WORK. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR RESETTING ALL DISTURBED EXISTING MANHOLE COVERS, VALVE BOXES, BLOW -OFF RISERS, ETC. TO NEW ELEVATIONS, AS REQUIRED, WHETHER SPECIFICALLY SHOWN ON THESES DRAWINGS OR NOT. 7. BOUNDARY AND TOPOGRAPHIC DATA BASED UPON SURVEY PREPARED BY FLORIDA INTERNATIONAL LAND SURVEYORS, INC., MIAMI LAKES, FLORIDA, DATED JUNE 12, 2007. S.W. 66TH STREET to 3 S.W. 66TH T vi S.W. bilH.-STREE1 THIS PROJECT w e) 5 d Gq' off' G SECTION 25 TOWNSHIP 54 SOUTH RANGE 40 EA51 LOCATION SKETCH SCALE: 1 " = 300' LEGAL DESCRIPTION LOT 1 THROUGH 10, OF BLOCK 11 "TOWNSITE OF LARKINS", ACCORDING TO PLAT THEREOF AS RECORDED IN PLAT BOOK No 2 , AT PAGE 105 OF THE PUBLIC RECORDS OF MIAMI DADE COUNTY, FLORIDA. r _,.ti Try gg^y *J *, Rtt . LE Ir S.,l,� I _ r d aT ......... .......�.. -----,SDI//w�``�SyPS� �.�jti`tWi S/1LF�W I'tl i CEPTAi ICE VA ID FOR TV-10 YEARS r,ND DOES tIOT REL.EVE HIS 1=e t()i, IL�E1. /a111 t,Ql ITf�Ar"TOR FfVNI CONIFLIfACE %Nff ii ALL fl IS !'•t' 11 t[ s I Y 11 J1,) STF,,TE i?EQUIF',E .04TS At,1D AGREED+BEN S. HEALTH DEPARTMENT NOTES (NOT A PART OF M-DWASD NOTES OR APPROVAL) WATER MAIN HORIZONTAL SEPARATIONS SEPARATIONS SHALL BE MEASURED OUTSIDE EDGE TO OUTSIDE EDGE BETWEEN WATER MAINS AND, STORM SEWERS, STORMWATER FORCE MAINS, OR RECLAIMED WATER LINES, SHALL BE_3 FT MINIMUM. BETWEEN WATER MAINS AND VACUUM TYPE SEWER PREFERABLY 10 FT. AND AT LEAST 3 FT. MINIMUM. GRAVITY OR PRESSURE SANITARY SEWERS, WASTEWATER FORCE MAINS OR RECLAIMED WATER PREFERABLY 10 FT. AND AT LEAST 6 FT. MAY BE REDUCED TO 3 FT. WHERE BOTTOM OF WATER MAINS IS AT LEAST 6 INCHES ABOVE TOP OF SEWER. 10 FT. TO ANY PART OF ON -SITE SEWER TREATMENT OR DISPOSAL SYSTEM. WATER MAIN VERTICAL SEPARATIONS NlWb 1-13AI31it ",` . N,,, x , ;yatf,f� L,�s ; { ei, ;j�y� SEPARATIONS BETWEEN WATER MAINS AND GRAVITY SEWER, VACUUM TYPE SEWER, OR STORM SEWERS, TO BE PREFERABLY 12 INCHES, OR AT LEAST _6 INCHES ABOVE, SIR - #-vut-M 9 f (1 OR AT LEAST 12 INCHES IF BELOW.* T:;?s�ypM--�-^ e�:a?;•�.�':�`,D �Tt �`7y `'') PRESSURE SANITARY SEWER, WASTEWATER OR STORMWATER FORCE MAIN, OR RECLAIMED WATER, AT LEAST 12 INCHES E.tGpt, TfF�' ABOVE OR BELOW. * NOTE: CENTER 1-FULL LENGTH OF WATER MAIN PIPE AT CROSSINGS; ALTERNATIVELY ARRANGE PIPES SO JOINTS ARE AT LEAST 3 FEET FROM JOINTS IN VACUUM, STORM OR STORM FORCE MAINS. AT LEAST 6 FEET FROM JOINTS IN GRAVITY OR PRESSURE SEWERS, WASTEWATER FORCE MAINS OR RECLAIMED WATER. FLORIDA DEP/DADS COUNTY DERM NOTES ON WATER -SEWER INSTALLATION (NOT A PART OF M-DWASD NOTES OR APPROVAL) 1. A HORIZONTAL DISTANCE OF 10 FT. SHALL BE MAINTAINED BETWEEN WATER AND SEWER MAINS. WHEN THE 10 FEET HORIZONTAL DISTANCE CRITERIA CANNOT BE MET DUE TO AN EXISTING UNDERGROUND FACILITY CONFLICT, THE SEWER SHALL BE CONSTRUCTED OF DUCTILE IRON PIPE WITH MECHANICAL JOINTS. 2. A VERTICAL DISTANCE OF AT LEAST 18 INCHES SHALL BE MAINTAINED BETWEEN ANY WATER AND SEWER MAINS. THE SEWER SHALL BE A DUCTILE IRON SINGLE 20 FEET LENGTH CENTERED ON THE CROSSING IF THE MINIMUM VERTICAL DISTANCE IS LESS THAN 18 INCHES OR THE SEWER IS INSTALLED ABOVE THE WATER MAIN REGARDLESS OF SEPARATION). 3. IN HIGHLY CONGESTED AREAS, WHERE EITHER WATER OR SEWER FACILITIES ARE EXISTING AND THE SEPARATION REQUIREMENTS CANNOT BE MET, SPECIAL CONSIDERATION MAY BE GIVEN SUBJECT TO A COMPLETE EVALUATION OF EXISTING AND PROPOSED CONDITIONS. 4. THE MAXIMUM ALLOWABLE EXFILTRATION RATE OF GRAVITY SANITARY SEWERS CONSTRUCTED IN A PUBLIC WELLFIELD PROTECTION AREA SHALL BE FIFTY (50) GALLONS PER INCH PIPE DIAMETER PER MILE PER DAY FOR RESIDENTIAL LAND USE AND TWENTY (20) GALLONS PER INCH PIPE DIAMETER PER MILE PER DAY FOR NON-RESIDENTIAL LAND USE. 5. FORCE MAIN SEWERS CONSTRUCTED IN A PUBLIC WELLFIELD PROTECTION AREA SHALL BE EITHER DUCTILE IRON OR REINFORCED CONCRETE PRESSURE SEWER PIPE. THE DUCTILE IRON PIPE EXFILTRATION RATE SHALL NOT BE GREATER THAN THE ALLOWABLE ALLOWABLE LEAKAGE RATE SPECIFIED IN AMERICAN WATER WORKS ASSOCIATION STANDARD (AWWAS) C600-82 AT A TEST PRESSURE OF 100 POUNDS PER SQUARE INCH. 6. THE REINFORCED CONCRETE PRESSURE SANITARY SEWER FORCE MAIN EXFILTRATION RATE SHALL NOT BE GREATER THAN ONE-HALF (1/2) THE ALLOWABLE LEAKAGE RATE SPECIFIED IN AWWA C600-82 AT A TEST PRESSURE OF 100 POUNDS PER SQUARE INCH. 7. THE CONTRACTOR SHALL VERIFY NATURE, DEPTH, CHARACTER OF EXISTING UNDERGROUND UTILITIES PRIOR TO START OF CONSTRUCTION. 8. ALL OTHER PUBLIC OR PRIVATE UTILITY FACILITIES SHALL BE CONSTRUCTED AT LEAST 3 FEET FROM ANY WATER AND SEWER MAIN AS MEASURED FROM THE OUTSIDE BELL OF THE WATER AND SEWER PIPE TO THE OUTSIDE OF THE UTILITY PIPE. g, WHEN THE 3 FEET SEPARATION BETWEEN PROPOSED AND EXISTING LINE IS NOT POSSIBLE, THE CONTRACTOR SHALL HAND DIG OR EXPOSE THE WATER AND SEWER PIPES BEFORE PROCEEDING WITH POWER EQUIPMENT EXCAVATION. 10. IN NO CASE SHALL A CONTRACTOR INSTALL UTILITY PIPES, CONDUITS, CABLES, ETC. IN THE SAME TRENCH PARALLEL TO AND ABOVE EXISTING WATER AND SEWER PIPES EXCEPT WHERE THEY CROSS. ANY DEVIATION FROM NOTES 6, 7 AND 8 SHALL BE APPROVED IN WRITING BY THE RESPONSIBLE WATER AND SEWER UTILITY. 11. A NON-RESETTABLE ELAPSE TIME METER SHALL BE INSTALLED AT EACH PUMP TO RECORD THE TOTAL OPERATING HOURS OF THE STATION. SPECIAL NOTES (NOT A PART OF M-DWASD NOTES OR APPROVAL) 1. WATER SERVICE SHALL BE MAINTAINED TO ALL EXISTING USERS AT ALL TIMES. CONNECTION OF THESE EXISTING SERVICES TO NEW MAINS SHALL BE COORDINATED WITH EACH USER TO AVOID INTERRUPTION TO EACH BUSINESS. 2. PRIOR TO DISCONNECTION OF EXISTING MAINS TO BE REMOVED, EXISTING WATER METERS TO BE RECONNECTED TO NEW WATER SERVICES BY WASD FORCES AT OWNERS EXPENSE. 3. EXISTING WATER MAINS DESIGNATED FOR DEMOLITION SHALL BE REMOVED IN THEIR ENTIRETY AFTER CONNECTIONS HAVE BEEN CUT & PLUGGED BY WASD FORCES. ALEJANDRO REMOS R.A. - ircl-l-itQcts --- - i"' it Pins Blvd., Fuit> 107 hrol,aP,4es-rL 3302P - - �� ;954) 4�2 71-22- - 054) 4427190 remoshldg,5nol corn �I�� :RSET CHARr1-_ SCHOOL !t� South Miami SW 69th Street. `h r.lonii, FL. 33143 - -- --- - � ;-.t�NSULTANTS:--------�------ I � JEl NETH ARDILA ,rrchitect A11-3ERTO CHINCHILLA ai chltect ALEJANDRO CABAL -CABAL ,vrcliitect r,',►\RCEL ADRIAN PEREZ -irchitect 1'^' ,)1 P,nos Blvd , Suite 107 ,,i!,roke Pines FL. 33029 STRUCTURAL ENG.: E:DUARDO GONZALEZ P.E. INC. `,tructural Engineers .1 luardo Gonzalez P.E. Ponce de Ledn Blvd., Suite 335 r-11 Gables FL 33134 1 • I1 (305) 445 5100 (305) 445 6644 I nail, eddygon@bellsouth.net i M. .P. ENG.: IPI EMEL SA LLC. liUr_ `~IGN & BUILD ENGINEERING COMPANY TrITE OF FLORIDA CA No. 9113 f'r(!rro Arias P.E.63813 rcirlcia Morales P.E.63818 "!I)j 1 Johnson Street, Suite 115 r-fnb,oke Pines FL. 33029 USA TI (954) 318 2264 F -1 :(954) 4507216 a1: pedroaCingemel.com pmorales(t�_ ingemel.com CIVIL ENG.: ii Consulting Engineering A' cience, Inc. II t1^,I on H. Ortiz, P.E.57556 i„ 00 North Kendall Drive Surte 400 I lmiFL. 33176 ( 1305) 378 5555 1 (305) 279 4553 �,nd, no tiz(LCESh1W'AI corn i LA IDSCAPE ARCH.: I.l. L. A. GROUP INC. N'E 13th Street Suite 105 I' r ^f' Lnuderdals FL. 33304 1; ; (954) 763 4071 r , (95i) 467 1688 rnlagroupinc(-FDyahoo corn '=EAL: t FOR THE FIRST: NEISON 11. ORTI7, PE-57556 (CIVIL) !11EVISIONS: 'lrchitect Pr Flt. i)e oject No: -del -Ite:- 0880 - File:n b - aw V.Q. / A.M. proved by: N.H.O. 12/23/08 ale: AS SHOWN - CES PROJECT No. 08065 G-Dwiaht `��heet Title WATER / SEWER NOTES heet Number SOMERSET SOUTH MIAMi