Loading...
06-211-004LEGEND: F.A.C.P FIRE ALARM CONTROL PANEL SILENT KNIGHT SK-5700 ( ADDRESSABLE ) B.P,S INTELLIGENT POWER MODULE SILENT KNIGHT SK-5496 ( ADDRESSABLE ) Q SMOKE DETECTOR SILENT KNIGHT MOD SD505-APS O E SMOKE DETECTOR SILENT KNIGHT MOD S0505-APS ( FOR: ELEVATOR RECALL ) Q HEAT DETECTOR SILENT KNIGHT MOD SD505-AHS OH Q HORN/STROBE , GENTEX Model HS24-75WR ,75 CD AS NOTED © STROBE LIGHT ONLY , GENTEX Model ST24-75WR , 75 CD AS NOTED © MANUAL PULL STATION SILENT KNIGHT MOD SD500-PS/PSDA ® ADDRESSABLE RELAY SILENT KNIGHT MOD SD500-ARM JB JUNCTION BOX COMMENTS: I BUILDING IS NOT SPRINKLER NOTES: 1 SYSTEM IS POWER LIMITED 2 SYSTEM IS TOTALY SUPERVISED 3 ALL EQUIPMENT ARE UL LISTED AND COMPATIBLE FOR FIRE ALARM USED. 4 SYSTEM WILL MEET NFPA 72 AND NFPA 101 CHAPTER 32.2.3.4 5 SIGNALING LINE CIRCUIT IS ADDRESSABLE SLC LOOP ( UP TO 50 ADDRESSABLE POINT) ( STYLE Y ) 6 ALL NOTIFICATION APPLIANCES , HIGH IS 80" A.F.F BOTTON OF LENS. MANUAL PULL STATION HIGH IS 48 " A.F.F. 7 SCOPE OF WORK: INSTALLATION OF A COMPLETE FIRE ALARM SYSTEM ACCORDING TO NFPA 72. & NFPA 101 CHAPTER 32.2.3.4 8 SEQUENCE OF OPERATION UPON ACTIVATION OF ANY AUTOMATIC OR MANUAL DEVICES, ALL AUDIBLE AND ALL VISUAL ALARM WILL BE ACTIVATED UNTIL SYSTEM IS RESET , IF ANY TROUBLE OR SUPERVISORY OCCUR , A VISUAL AND AUDIBLE SOUND WILL BE DISPLAY AT FIRE ALARM CONTROL PANEL. A SIGNAL WILL BE TRANSMITED TO REMOTE STATION VIA DIGITAL COMMUNICATOR 7 lrlC UCJIhN INWALLAIIVN I.VMI'LItZi WWI tUl; I1-4.Li3..y 10 WIRES ARE : FPL 16/2 ( SHIELDED ) FOR SLC LOOP - AO FPL 14/2 NAC 11 CONDUIT SIZE , E.M.T. 1/2 " MINIMUM WITH 40 % MAX FILL . ( 3/4 " EMT WILL BE USED AS WELL ) 12 ACCUSTICAL CEILING HIGH 8'-0" VOLTAGE DROP TABLE FIRE ALARM SYSTEM. 14 AWG - 3 ohms/1,000 Feet Device 01y Wire Size 14 AWG Wire Leoght Total Drop Amps Resistance X 1000 Feet out Return Per Circuit A 8 C D E F NAC 1 2 0.192 3 Ohms 1000 200 200 0.46 6 0.158 3 Ohms 1000 200 200 1.14 TOTAL DROP NAC 1 1.60 NAC 2 2 0.192 3 Ohms 1000 200 1 200 0.46 4 0.15a 3 Ohms 1000 200 200 0.76 TOTAL DROP NAC 2 1.22 FIRE ALARM SYSTEM BATTERY CALCULATION Standby Total Alarm Total Current Current Current Current Devices Model Oty Amps Amps Amps Amps Silent Knight SK-5700 1 0.16 0.16 0.33 0.33 All Addressoble Devices 21 0.00053 0.01155 0.00055 0.01155 Noc 1 Horn/Strobe 75 cd 2 0.192 0.384 Noe 1 Strobe 75 cd 6 0.158 0.948 Noc 2 Horn/Strobe 75 cd 2 0.192 0.334 Noc 2 Strobe 75 cd 4 0.158 0.632 Sum Rows f Standby Lo `.)4rlip"` 31'7155:` Multiply By Require tdndb T•rrne (24/60-H AS ' M-4 , Total' Standby LooO (AH) 4.11 Sum�Row3 For. -Norm Load C Ar�, �2. Multiply By 0squeed Norm iinne (5 (d ryr,�ir0/0 4� /� / b. 4 TonPJ4rger lorlodTAy 24 Total Total Requred Solely - _ r fg910 Scat •'Ampa�ea: #,s StandbyLoad Alarm Loud AH Factor .-, • -- . ,i - � (AH ) ( AH ( AH ) (Multiply) Required! 4.117 0.224 4.34 1.2 5.21 HALL PROVIDED BATTERY SIZE v TWO ( 2 ) 12 V , 7.0 A/H FIRE ALARM WIRE LEGEND A 2#16 FPL SHEILDED TWISTED PAIR DATA , SLC LOOP 8 2#14 FPL SOLID HORN/STROBE c VOLTAGE DROP TABLE INTELLIGENT POWER MODULE 14 AWG - 3 ohms/1,000 Feet Device Oty Wire Size 14 AWG Wire Lenght Total Drop Amps Resistance X 1000 Feet out Return Per Circuit A 8 C D E F NAC 1 2 0.192 3 Ohms 1000 200 200 0.46 9 0.158 3 Ohms 1000 400 200 1.71 TOTAL DROP NAC 1 2.17 NAC 2 2 0.1921 3 Ohms 1000 200 1 200 0.46 6 0,1581 3 Ohms 1000 200 1 200 1.14 TOTAL DROP NAC 2 1.60 INTELLIGENT POWER MODULE BATTERY CALCULATION Devices Model Oty Standby Current Amps Total Current Amps Alarm Current Amps Total Current Amps Silent Knight SK-5496 1 0.040 0.040 0.160 0.160 Noc 1 Horn/Strobe 75 cd 2 0.192 0.384 Noc 1 Strobe 75 cd 9 0.158 1.42 Noc 2 Horn/Strobe 75 cd 2 0.192 0.384 Noc 2 Strobe 73 cd 6 0.158 0.948 Sum Rows for Standby Load ( Amps) 0.040 Multiply By Required Standby Triode (24/60 Hours) 24 Total Standby Load ( AH) 0.96 Sum Rows For Alarm Load ( Amps) 3.30 Multiply By Required Alarm Time (5 Min 0.084) 0.084 Total Alarm Load ( AH) 0.274 Total Standby Load ( AH) Total Norm Load ( AH ) Required AH ( AH ) Surety Factor (Multiply) Total System Amperes / Hours Required 0.96 0.274 1.234 1.2 1.48 WILL PROVIDED BATTERY SIZE - TWO ( 2 ) 12 V , 4.5 A/H SECOND FLOOR FIRST FLOOR I NAC 2 1 2 I NAC 1 IN NAC 1 NAC 2 NAC i 75cd 75cd 75cd 75cd E) L L a H3-1 1-13-2 H3-3 H3-4 75cd 75cd 75cd 75cd 143-5 H3-6 H3-7 H3-8 NAC 2 EOL MAX LOAD = 1.33 Amps NAC 2 MAX CAPACITY IS 3.0 Amps 75cd 75cd 75cd 75cd 75cd 75cd 75cd 75cd 75cd 75cd 75cd 1-12-1 H2-4 H2-5 1-12-6 H2-7 H2-9 H2-10 L H2-11 NAC 1 EOL MAX LOAD = 1.80 Amps NAC i MAX CAPACITY IS 3.0 Amps 1,12-3 1-12-8 H2-2 Elev Lobb M-20 M-21 SILEENT KNIGHT SK-5496 H SILENT KNIGHT SK-5700 M-3 F-1 _ Sys fellatinNo. C-AJJ-1149 i Rat. 0 Hr L Rat ilg At Anbient -Less Than I CFM/sq fit L Ratrq At 400 F - 4 CFM/sq It 1. now WM0a 00 �bsw* - Will 4-1/2 n. M ranhmed �gMwi+gipld or ..1N 100150 PO WOft sus mar 00 W caelnwcld Of oit UL Gam ed C;= ft" 0. go bar d aprsiq 's 12 I R Sw Conade 9odn Z wt•9n is Un rre hAilonco tSTrectoq b .10 gorrwvioc,oes L ft-0 Pv*onb - Ono ff*Uk Pp• cw" a hkill to be i WOW ar bouu aCa of Iboa ed n10 wvlj r spoci fd• woo o (Pod 044 to ma 1-1/4 in no FOloriq W" 014 $;M ool Tallow pgee, confuib or lepin9 r q a wad A Slat F" - Na, 10 R San (or 9maNr) Sd*" 10 (r I Norio) 31W P4L a Cow c 4 in. Sam (or sroiting or) " electru meW* b C CWW= -Nor 4 w San (or •nano) ro 1. (or kwiAr) CCFPW M Capper FW - UN 4 R Sam (or •mNM) " (Of I"o,irf r) eoppor FiDo• S Poclaiq *IVW1 - We J is tti*" of mn 4 Pd mim d •odd boll irmAdior ra nor 4 is doe ford ertdr) ppee, coo" or luAvp ad e mio 4 w C$iao nof roll i pd ni�sod rod boll irouloloo hkr pq 00 r 4 k 6^ r" PM ift W44 as Pwmroosi Ponotl4 mot" to be ricmW roan too allow of Ior 1 or No dbo vofoca roll w cw "irw to ow*mo V* rpnd Uiuikk at MdW4. ri, vat or Co* tatraP - Sem - We 1/2 n. vi*4 o ow O motrlol oppied V"w Woos, kids wall "alp ewroco dor ofI flow boll aAoxo aI rdL N IN Point of wntod low5on Wow ppyo ood cr+o o mil 1/2 in• Sao boot or fa molorw #4 be woo of Uu pw Wol000 on the Wo arrow of Floor and or Wh IaRaa HLs ITC - CM1% CPtOb a FS-M SW" (rats L %j r, wry Thal fs-OK Sealrt .wed} uy u rcowe oeradKW to M e,e pop" r rrlcfror sslars aic.r6er iamoo `" CMVUS 75cd 75cd 75cd 75cd 75cd 75cd NAC 2 EOL MAX LOAD = 1.01 Amps H L L L L H NAC 2 MAX CAPACITY IS 2.5 Amps 14-1 H4-2 1-14-3 H4-4 H4-5 H4-6 75cd 75cd 75cd 75cd 75cd 75cd 75cd 75cd NAC i EOL MAX LOAD = 1.33 Amps t I1-1 H1-2 H H L 1 H L L L L-3 HI-4 H1-5 H1-6 H1-7 H1-8 NAC 1 MAX CAPACITY IS 2.5 Amps 1 2 3 4 =Lobbyflln Ele --U M-1 u M-2 Front Entry Reor Exit 7 8 9 10 A/C Room A/C Room Elect Room TWO ( 2 ) PHONE LINE TO REMOTE MONITORING STATION , VIA DACTI 3-0 12 AWG TO A DEDICATED 120 VAC , 20 AMPS , EMERG HOUSE P 25 1 12 r)ri ,u •,•rr J ) S 11 J� 1 1 ! • ! '� • . IN 1'J � O ,4 r•-4 M �a W E-4 ' o f-•i • r C1, N 04 d O O d W O e_•e w w ♦ � W "0 -N 0 O O L- O �. 12 0 +. W Q� �- V) O C' V Z Q O cc 0 JLL LLJ W Q U Q � LL- I- LLLJ 0 = W -< V) LlJ V - ^O �" 0 rn L.J.. � 0 (0 Qf L.J... SHOP DRAWING Riser Diagram OWNER ATE 12712/2005 DRAWN BY ENGINEER SEAL EUGENE EVISED' BY: GERARDO VAZQUEZ DE MIGUEL GERARDO F # 42792 SCALE 1, {�}= N. T.S. j 46�A NTICT ISLAND s 6EACHrF3160I. Sheet No. O ;�.9G40;r3914 -2 F A SIGNATUR.-e SEAL SHEET 2 Of 2 se it