Loading...
06-211-002i LEGEND: F.A.C.P FIRE ALARM CONTROL PANEL SILENT KNIGHT SK-5700 ( ADDRESSABLE ) B.P.S INTELLIGENT POWER MODULE SILENT KNIGHT SK-5496 ( ADDRESSABLE ) Q SMOKE DETECTOR SILENT KNIGHT MOD SD505-APS OE SMOKE DETECTOR SILENT KNIGHT MOD SD505-APS ( FOR ELEVATOR RECALL ) O HEAT DETECTOR SILENT KNIGHT MOD SD505-AHS HORN/STROBE , GENTEX Model HS24-75WR ,75 CD AS NOTED © STROBE LIGHT ONLY , GENTEX Model ST24-75WR , 75 CD AS NOTED © MANUAL PULL STATION SILENT KNIGHT MOD SD500-PS/PSDA ® ADDRESSABLE RELAY SILENT KNIGHT MOD SD500-ARM rJ-Bj JUNCTION BOX COMMENTS: I BUILDING IS NOT SPRINKLER NOTES: 1 SYSTEM IS POWER LIMITED 2 SYSTEM IS TOTALY SUPERVISED 3 ALL EQUIPMENT ARE UL LISTED AND COMPATIBLE FOR FIRE ALARM USED. 4 SYSTEM WILL MEET NFPA 72 AND NFPA 101 CHAPTER 32.2.3.4 5 SIGNALING LINE CIRCUIT IS ADDRESSABLE SLC LOOP ( UP TO 50 ADDRESSABLE POINT) ( STYLE Y ) 6 ALL NOTIFICATION APPLIANCES , HIGH IS 80" A.F.F BOTTON OF LENS. MANUAL PULL STATION HIGH IS 48 " A.F.F. 7 SCOPE OF WORK: INSTALLATION OF A COMPLETE FIRE ALARM SYSTEM ACCORDING TO NFPA 72. & NFPA 101 CHAPTER 32.2.3.4 8 SEQUENCE OF OPERATION UPON ACTIVATION OF ANY AUTOMATIC OR MANUAL DEVICES, ALL AUDIBLE AND ALL VISUAL ALARM WILL BE.ACkVATE0 UNTIL SYSTEM IS RESET , IF ANY TROUBLE OR SUPERVISORY OCCUR , A L A UD►B UND L BE DISPLAY AT FIRE ALARM CONTROL PANEL. A SIGNAL WILL BE TRANSMITED 0 CERTIFICATE/PLACARDED CENTRAL STATION SERVICE V1 DIGITAL COMMUNICATOR 9 THE DESIGN INSTALLATION COMPLIES WITH FBC 11-4.28.3 , 10 WIRES ARE : FPL 16/2 ( SHIELDED) FOR SLC LOOP - AO FPL 14/2 NAC Q !, 11 CONDUIT SIZE , E.M.T. 1/2 " MINIMUM WITH 40 7. MAX FILL . ( 3/4 " EMT WILL BE USED AS WELL ) 12 ACCUSTICAL CEILING HIGH 8'-0" VOLTAGE DROP TABLE FIRE ALARM SYSTEM. 14 AWG - 3 ohms/1,000 feet Device Oty Wire Size 14 AWG Wire Lenght Total Drop Amps Resistance X 1000 Feet Out Return Per Circuit A B C 0 E 1F NAC 1 2 0.192 3 Ohms 1000 200 200 0.46 10 0.158 3 Ohms 1000 200 200 1.90 TOTAL DROP NAC 1 2.36 2 0.192 3 Ohms 1000 200 1 200 0.46 NAC 2 4_ 0,115jE 3 Ohms 1000 j 200 1 200 0.76 1 I TOTAL DROP NAC 2 1.22 FIRE ALARM SYSTEM BATTERY CALCULATION Devices Model Qty Standby Current Amps Total Current Amps Alarm Current Amps Total Current Amps Silent Knight SK-5700 1 0.15 0.16 0.33 0.33 All Addressoble Devices 21 0.00055 0.01155 0.00055 0.01155 Not 1 Horn/Strobe 75 cd 2 0.192 0.384 Noe i Strobe 75 cd 10 0.158 1.58 Noc 2 Horn/Strobe 75 cd 2 0.192 0.384 Noe 2 Strobe 75 cd 4 0.158 0.632 Sum Rows for Standby Load ( Amps) 0.17155 Multiply By Required Standby Time (24/60 Hours) 24 Total Standby Load ( AH ) 4.117 Sum Rows For Alarm Load ( Amps) 3.33 Multiply By Required Alarm Time (5 Min s 0.084) 0.084 Total Alarm Load ( AH) 0.278 Total Standby Load ( AH) Total Alarm Lood ( AH ) Required AH ( AH ) Safety Factor (Multiply) Total System Amperes / Hours Required 4.117 0.276 4.39 1.2 5.27 WILL PROVIDED BATTERY SIZE = TWO ( 2 ) 12 V . 7.0 A/H FIRE ALARM WIRE LEGEND A 2#16 FPL SHEILDED TWISTED PAIR DATA , SLC LOOP B 2#14 FPL SOLID HORN/STROBE C 1A VOLTAGE DROP TABLE INTELLIGENT POWER MODULE 14 AWO - 3 ohms/1,000 Feet Devito Oily Wire Size 14 AWG Wire Lenght Total Drop Amps Resistance X 1000 Feet Out Return Per Circuit A B C 0 E F NAC 1 2 0.192 3 Ohms 1000 200 200 0.46 9 0.158 3 Ohms 1000 200 200 1.71 TOTAL DROP NAC 1 2.17 2 0.192 3 Ohms 1000 200 Y00 0.46 NAC 2 7 0.158 3 Ohms 1000 200 1 200 1.33 TOTAL DROP NAC 2 1.79 INTELLIGENT POWER MODULE BATTERY CALCULATION Devices Model Qty Standby Current Amps Total Current Amps Alarm Current Amps Total Current Amps Silent Knight SK-5496 1 0.040 0.040 0.160 0.160 Noc 1 Horn/Strobe 75 cd 2 0.192 0.384 Noc 1 Strobe 73 cd 9 0.158 1.42 Noc 2 Horn/Strobe 75 cd 2 0.192 0.384 Not 2 Strobe 75 cd 7 0.158 1.106 Sum Rows for Standby Load ( Amps) 0.040 Multiply By Required Standby Time (24/60 Hours) 24 Total Standby Load ( AH ) 0.98 Sum Rows For Alarm Load ( Amps) 3.454 Multiply By Required Aiorm Time (5 Min 0.084) 0.084 Total Alarm Load ( AH) 0.287 Total Standby Load ( AH) Total Alarm Load ( AH ) Required AH ( AH ) Safety Factor (Multiply) Total System Amperes / Hours Required 0.96 0.287 1.247 1.2 1.50 WILL PROVIDED BATTERY SIZE s TWO ( 2 ) 12 V , 4.5 AIR I NAC 22 1 I I NAC 1 I SECOND FLOOR 75cd F175cd 75cd 75cd 75cd 75cd 75cd 75cd 75cd L L H NAC 2 EOL MAX LOAD = 1.48 Amps NAC 2 MAX CAPACITY IS 3.0 Amps 3-9 6 1-13-1 1,13-2 H3-3 H3-4 H3-5 H3-6 H3-7 1-13-8 75cd 75cd 75cd 75cd 75cd 75cd 75cd 75cd 75cd 75cd 75cd F1 NAC i EOL MAX LOAD = 1.80 Amps ��i�Lr� I-L� L"J�� ` ` ` ` L NAC i MAX CAPACITY IS 3.0 Amps 1-12-1 1-12-2 H2-3 H2-4 H2-5 1-12-6 H2-7 1-12-8 1-12-9 1-12-10 1-12-11 E Elev M-20 M-21 75cd 75cd 75cd 75cd 75cd 75cd H L L L L H 2 H4-1 H4-2 1 H4-3 H4-4 H4-5 H4-6 1 INAC 1 75cd 75cd 75cd 75cd 75cd 75cd 75cd 75cd 75cd 75cd 75cd 75cd H L L L L L H L L L L L HI-1 HI-10 1-11-2 Ht-11 Ht-12 Hi-3 HI-4 HI-5 HI-6 HI-7 1-11-8 HI-9 to 26 1 2 3 4 5 6 7 8 9 10 11 12 s s s s s 1.1 / Lobby E \ Files Room "AICR��Elev A/C Room Elect Room I SILENT KNIGGHT SK-5496 M-3 FIRST FLOOR System No. C-AJ-1149 FRotN-2it, - t Rotn0 Fir 13 L Rating At Ambient - less Thor 1 CFWsq Tt L Rating At 100 F - 4 UK/sq Ft ` 2 4\ i �- A SECT1tN A -A 1. fbm or W Ame " - Vs 4-1/2 i% W rdefarced ~ m rom+d .e94 (t00-170 pc� cp+vele. sal any 0* be mmkctef d any Ut 00"Tsd Convsb gods ! Mw 6os d ap•irg is 12 iL sw Canaeb RKW (Gill eoblay is IN rre WSW" 5*Wy roe wm of msa,lac6V% L Ihm* Pwba.b - One m*k PPel, co4A of blip to be in $W w1h8 14 beslal 4,17 P4a cadet ar haiq b b• r.�ly Rovalea oe boa edw d moor a iol oswnDly. its onv/or epop >Jn1 be 0 in. (Dili tonloall it Tile bip mw 1-1/4 1% iiy lrpw end new of mrlois P01% caduls of lubip mqr be L" A star PW - Mom to ik hoe (or woo) Sdsdule 10 (m haeer) Seel pqa 8 C* AA - No 4 h. bar (m ender) $led electrical medals W" or Seel aandui C. Coppery - Mom 4 is 64re (of gnaw) Type L (Of *4) ewe0. Copper P'ye - Mae 4 iu 6om (m smd:) (m h-*) C%W I Pochip MoWW - tie 3 it sabres d min 4 pd m meal !od bat ieublVt tar mom 4 it owe (vd Wdr) D9m cmdAt m binge and e ms 4 ti pidmete d ms 4 pal ,,minr�ait .od boM ia+bloe b ppe �a1� sae mom 4 it 6aml, rimip pocked in b opens as s Pei am rpm podu�q flVW4 b be n--, Irve Ioopp �uloaa d door or room boa >trlocw of wl w rvow to @s m9sed UaMnae d li moteriat 4. rill, ibid m Cwlt MoWvP - S Wait - 1& 1/2 R Vibes of M md" appfs0 wait 1M 0"" tab wlh N ta/ aidwo al Am of sulaaw al ,d. 4 tilt pal of woad WN A bel"m M and wv*sr a mire 1/2 s. &a bead of 1111 nderid trot be WW d N aa+creWpiae W*1a1 as Us ln/ wlace of kw W4 on Will sutom d t' t Ca Gfflum OCACAM ON or tlLn w6 - WW1; M at rs-aMt So*t (dote: 1 �Ggk _ r hw iS-p� sealant s =4 b� lFifO �1 • ee,00.le q tat rc uik,e d �necsrav ssTo a Iwn4. M " C US NAC 2 NAC i SILENT KNIGHT SK-5700 F-1 J M-1 t• r M-2 Front Entry Rear Exit TWO ( 2 ) PHONE LINE TO REMOTE MONITORING STATION ,VIA DACTI 3-► 12 AWG TO A DEDICATED 120 VAC , ZO AMPS , EMERG HOUSE PANEL NAC 2 EOL MAX LOAD = 1.01 Amps NAC 2 MAX CAPACITY IS 2.5 Amps NAC 1 EOL MAX LOAD = 1.96 Amps NAC 1 MAX CAPACITY IS 2.5 Amps BIiE A.LARiVI SYSIETM 7013E 1NS"TALL.F D IN ACCORDANCE WPI,H Nil?PA `1Z; ?0;101 tjlN NMAII-DA WF, C0TJP 1Y FIid IMPART 'NT FIRE SUPPAES810N.. _ . �. WATEPW N UT. -- OATS: e) I l, �><) • $Y1 ( 4-;�) w A_ Q j op VC oa 0 O O li- O F- .. Q CL :2 O V) 0 FF--- >- V) Z 0 O � 0 do O Q LL Ld Q LLB U_ Q W !L. V. Lv L2_ O U V) W Z - CV _ Z = V) 0 V) Ld Q 0^ Ld ~ 0 l.J... 0 SHOP DRAWING Riser Diagram Revisions AFire Reviewer Comments 1 / 17 / 2006 ATE 12/12/2005 RAWN BY ENGINEER SEAL EUGENE REVISED BY: GERARDO VAZQUEZ DE MIGUEL GERARDO = +111 SCALE P.E. # 42792 N.T.S.. 240 ATLANTIC ISLAN ''�� , • • ' . e �: I EFr.4 3t6 �: '�►. Sheet No. SUNNYISLES B Ph: (305) 9f FA-2 SIGNATURE SHEET 2 of 2 � ' . � SEA4 _ � � �� rRrlf�eil�1At91®