5920 SW 68 ST EB-10-030-004 ----------- -------
6 7 9 10 12
13 14 15 16
........... 17
------------ ----------
Ml
TYPE MAIN BUS 200 AMP ------------
SERVICE OFFICE/ TERAPY
VOLTAGE : 120/240 PANEL A " 10,000 AIC NEUTRAL 200 AMP
MAINS
CE
MOUNTING FLUSH ALL 20 A.I.P. CIRCUIT EXCEPT AS NOTED LOCATION SHOWN f N,
C-1 C-1 THEPAPY
TOTAL COND CKT. _�KT. 4D TOTAL
COI` ROUM
WIRE
AMPS POLES WIRE REM IRKS REMARKS A
EXIST
V.A. SIZE+ NO. NO.
SIZE+ V.A.
20 1 1100 1/2" 12 LIGHT'ING 1 2 LIGHT & RECEP. 12 74 4� 4 24 4. 4 At CLOS�f
1/2' 960 1 20
20 1 1100 1/2" 12 LIGHT & f ECEP. 3
L 20 1 300 1/2" 12 EMG. EJT LGT 5
7
-----------
C-6
9 C-6
T.S.
11
2' x 4'
THERAPY ROOM FLUO. LAMP
13
C , ELECT.
15 TYP.)
PANEL
17 "A" L
19 L--- SEAL
K C-2, C-5 L
21
23 44 EXI
2)
I C-6 C_
x EMEHU NCY
25 C! LIGHT
27
29 C-5 BACKUR–i
31 BAIT.
x C_
33
35
37 38 0 4 2
C 2
39 40 C-6
----L42
J- --------L------J-
41
7T
C, 4 4[J P�E I C-4
CONNECTED LOAD: 3300/ 240 14 At IP. FEEDER 3 2/ 0 Cu. IkIl I,- - ' I ', � .- -1 -
* WITH BACKUP BATTERY GF
* WITH TIMER FED FROM SERV.
ALU C-5
GENERAL ELECTRICAL NOTES: 74
C-7
1. ALL WORK SHALL BE IN ACCORDANCE WITH THE *LORIDA BUILDING D OFFICE C-2
CODE, NEC AND OTHER APPLICABLE CODES AND STi NDARDS, GFI
LL/ /I
2. CONTRACTOR SHALL BE RESPONSIBLE FOR EVALU kTING FIELD CONDITIONS / / , �z I I/ CONFERENCE C-7
BY VISITING THE SITE PRIOR TO COMMENCING BIDDII` 3 WORK. t/
Z Z__Z_ C-2 ROOM
3. CONTRACTOR SHALL SCHEDULE WITH OWNER ANY INTERRUPTION OF 71Z 71, C-3 C-4
POWER
C-7
4. APPROVAL SHALL BE OBTAINED FROM A REGISTEFED STRUCTURAL ENGINEER
ENGINEER PRIOR TO CUTTING OR DRILLING ANY STRI CTURAL SUPPORT �7 C-3 OFFICE
H MEMBER. C-7
01 W-2
5. EXISTING ELECTRICAL INSTALLATION NOT IN HSE E IALL BE REMOVED C-3 ANTONIO ACOSTA
7 C-4
COMPLETELY Pk. Lic. # 40845
6� ALL LOADS EXCEPT GENERAL LIGHTING ARE IJEINC
CONSIDERED NOW 10305 NW. 41 ST.
CONTINUOUS LOADS.
2
�U_ W MIAMI, FL 33178
7 ,2 x2
7� ALL MATERIAL SHALL BE UL APPROVED. V / Ph: (305 ) 8S6 4606
7'
8. ALL BRANCH CIRCUITS SHALL BE PROPERLY PIHA� -__ BALANCED.
7
f
9. CIRCUIT DESIGNATIONS ARE SHOWN FOR IDEIITIFIC TION ONLY. EXISTING 2 / I / /
FIELD CONDITIONS WILL DICTATE ACTUAL CIRCUR_ 4�2 219
3 TO BE USED. WRITTEN DIMENSIONS ON THIS DRAWING SHALL
G CONTRACTOR SHALL RECORD ON DRAWINGS THE ACTI AL CIRCUIT USED. HAVE PRECEDENCE OVER SCALED DIMENSIONS,
24 CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE
FOR ALL DIMENSIONS AND CONDITIONS ON
10. ALL PULL BOXES OR JUNCTION BOXES SHAI �14 t" �I
ALL TIMES, _L Bf ACCESIBLE AT ,,,/.W�"41-- THE JOB AND THIS OFFICE MUST BE NOTIFIED
I/ OF AW VARIATION FROM THE DIMENSIONS,
11. ALL WORK SHALL BE DONE IN A NEAT AND WOR ',MANLIKE MANNER.
T
12. PROVIDE ALL FINAL CONNECTIONS TO ALL EQUIPI` ENT AND APPLIANCES. Revisions
1Z NM
L U A
11 ALL LAVATORIES, KITCHEN AND OUTDOOR RECEPT ,CLES SHALL BE
GFC1 PROTECTED,
14. ALL CIRCUITS AT BEDROOM SHALL. BE ARC FAULI CIRCUIT BREAKER
PROTECTED. INCLUDED LIGHTS AT BATHROOM & WAL� -IN CLOSETS
F
15. ALL WIRING TO BE ROMEX CABLES. T!
74
16. HEIGHT OF SWITCHES AND RECEPTACLES SHALL BE CHECKED WITH
ARCHITECT. RECOMMENDED HEIGHTS: > 71 V
- COUNTER RECEPTACLES AND LAVATORIES: UL24 F7
8" ABOVE COUNTER
- LIGHT SWITCHES: 48" FROM FINISHED FLO( R 7 C-5�]
- DRYER: 45" FROM FINISHED FLOOR 150
2
- MICROWAVE RECEPTACLES: 75" FROM FINIS iED FLOOR
-4 U�/
T A N 7'
17. EMT CONDUIT MAY BE USED ABOVE CEILING
L C-5
E
18. ALL LUMINAIRIES SHALL BE PROPERLY SUPPORTE IN ACCORDANCE 7
!,AG
WITH THE CEILING SYSTEM MANUFACTURER RECOMME� DATIONS AND LOCAL
CODE REQUIREMEN7
EXISTING DAY CARE STORAGE
TO REMAIN
19. SHORT CIRCUIT AMPERES IS 10 KA FOR PROTECI ON DEVICES, BUT
DEFINITIVE VALUE SHALL BE OBTAINED BY ELECTRICAL CONTRACTOR AT 24 4f
EXECUTION TIME.
(2 i4l
3 2/0 THWN-2- COND. x 4 2 4, Project Name:
TIIERAPY ROOM
INTERIOR REMODELING
D 5920 SW 68 ST
;0 _ 'C T 4 �LG 4
41- x 1141 MIAMI,FLORIDA
ELECTRICAL
2"
METER ELECT.
PANEL
T.S. x
A33, 200A 240V 120 V 1 PH EXIST.)
C SERVICE ENTRANCE RATED
File-
4
/74
Scale: AS SHOWN
3 2/0 THWN-2- COND. 2 lc�p
24
4, 4
2 124
124 Date: FEB /20'fO
I # 4 THWN-3/4-
3 2/0 THWN-2- COND. (GRD PER NEC.) Y. Drawn. —A.PONG
Checked:
PROVIDE TWO 5/8- X 10- COPPER CLAD Submittal:
GROUNDING ROD TO A 3/4- COPPER
WATER PIPE STUB–OUT
Drawing Title:
CU
42
5T 5, T 5T
EXISTING BUILDING TO REMAIN
ELECTRICAL RISER ELECTRICAL FLOOR PLAN,
SECTION
SCALE: N.T.S.
A
& NOTES
------------------------------------------
U62
ELECTRICAL FLOOR PLAN `;7
Sheet No. E-1
SCALE: 1 /4"
0 -----------
6 7 8 9 10 12 13 14 15 16 17