Loading...
BCP18-1243-03r71NO SYSTEM SPECIFICATIONS (G62-Series) 1. 3" or 4" female thread inlet/outlets 2. Max flow rate: 35 GPM 3. Liquid capacity: 40 Gallons 4. Max grease capacity: 180 lbs. Grease capacity based off 99% efficiency per Miami Derm FOG 2.0 requirement 5. Pedestrian rated cover (450 lbs without riser) 6. Maximum operating temperature 140°F continuous. NOTES 1. Each unit certified and listed by IAPMO to ASME #A112.14.3 and CSA B481.1 grease interceptor standards 2. Flow control to be installed in first unit only. 3. For gravity drainage applications only. Do not use for pressure applications. 4. 3/8" thick seamless high density polyethylene walls. 5. Cover placement allows full access to tank for proper maintenance. 6. Vent not required unless per local code. 7. Designed narrow footprint allows clearance through doorways and down stairwells. 8. Engineered inlet and outlet diffusers are removable to inspect/clean piping; 9. For on -the -floor or buried applications. 10, Locate interceptor as close as possible to grease producing fixtures. 11. Integral Air Relief / Anti -siphon. 12. Three outlet options for easy rough in. Unit shipped with outlet diffuser in outlet "B". DIFFUSION FLOW TECHNOLOGY The inlet diffuser splits incoming efFluent into two paths that utilize the entire liquid volume of the tank for efficient grease separation. The calibrated openings greatly reduce efFluent turbulence. The effluent enters the tank without disturbing the grease or sediment layers. Grease Capacities of Multiple Unit Systems at 99% Efficiency per Miami Derm FOG 2.0 Requirement 1. GB2-2 series = 180 lbs. 2. GB2-3 series = 310 lbs. Cuvar The outlet diffuser allows only effluent which is free of of inlet grease to exit the tank. It can easily be attached to any and outlet of the three outlets provided to ease lobsite piping layouts. OPTIONS: 'a 1 --' --- `- FCR1 - Field cut riser system Clamping collar 1 3.3i4„ t • PP1 - Pumpout port 8 14" I Product ID labels are located on this surface on exterior of the unit (typical each unit) All piping to, from and between units to be supplied by others GB2 grease interceptor (2) minimum Top View [Product ID is molded into the unit cover G132 grease'TrIlIrcer (2) minimum Side View ySr MODE`11 LNUMBER: LAYOUT DETAIL: 900 0123-01 SCHIER PRODUCTS WL G62-2-Series DESCRIPTION: PIO Ing Drm„ Lm PBmy MULTIPLE UNIT GREASE INTERCEPTOR SYSTEM 9500 Woodend Road LAYOUT DETAIL FOR 99% GREASE RATING Edwardsville, KS 66111 PROPRIETARY AND CONFIDENTIAL EFFICIENCY FOR MIAMI DERM FOG 2.0 Tel: 800-827.7119 THE INFORMATION CONTAINED IN THIS Dw.WNO 15 - Fax: 8CO-827-9664 THESOL PROPERTYOF SCHIER PRODUCTS ANY HE W"TTENP RMISSION°?s`"E"""°"°`T DWG BY: TEU DATE. 4/19/2018 REV: www.schierproducts.com PROHIBITED, ECO: - 1. FOG 2.0 RERNADERM DERM's FOG Control Device (FCD) Installation Inspection Required Prior to Plumbing Final for all Municipal projects. Failure to secure DERM's FCD Installation Inspection will result in disapproval of Final Inspection by the Municipal Building Official, pursuant to Section 24.42-6, MDC Code. To schedule DERM's FCD Installation Inspection for Municipal projects please send an email to 1FOG2@mlamidade.gov, 24 hours prior to desired date. Provide DERM plans process M-number, complete address of the site, folio number, and contact person name and phone number. AP RT pOCl1 Ec.4.l Philadelphia Sheet ii Orilririo, Coh"O nia - USA 91761.281 d ® Ph: Q09.472.4100 I Fox: 909.472.4243 httP:!`1�';csH.s;�l?nc+rtLe�rS Report Number: 1757-18018 Project Number: 29770 Report Issued: March 30", 2018 Client: Schier Products 9500 Woodend Rd. Edwardsville, KS 66111 Contact: Charlie Ismert of Samples: Samples were manufactured at the client's facility in Edwardsville KS. Source p Sa p y The sample was witnessed tested by Dale E. Holloway of IAPMO R&T Lab on 3/6/18. Samples are manufactured in good condition. Date of Testing: March 5th, 2018 through March 28th, 2018 Sample Description: HDPE Grease Interceptor. Model: GB2-2 (35 gpm) Refer to the manufacturer's drawings and installation instructions for more detailed measurements and information. Scope of Testing: The above grease interceptor was witnessed tested to meet the requirements of ASME Al12.14.3-2000 (Reaffirmed 2004) "Grease Interceptors", and CSA B481.1-12 "Testing and rating of grease interceptors using lard". Conclusion: The GB2-2 (35 gpm) Grease Interceptor DID COMPLY with the requirements of ASME All 12.14.3-2000 (Reaffirmed 2004) for "Grease Interceptors" and CSA 13481.1-12 "Testing and rating of grease interceptors using lard". By the signature below, I certify that all the testing and preparation for this report was performed under direct supervision of IAPMO R&T Lab, unless otherwise stated. Witness tested and reported by, (" zZ 0.,:� Dale E. Holloway, Regional Technical Manager IAPMO R&T Lab All testing and sample preparation for this report was performed under the continuous, direct supervision of lAPMO R&T Lab, unless otherwise stated. The observations, test results and conclusions in this report apply only to the specific samples tested and are not indicative of the quality or performance of similar or identical products. Only the Client shown above is authorized to copy or distribute the report, and then only in its entirety. Any use of the /APMO R&T Lab name for the sale or advertisement of the tested material, product or service must first be approved in writing by 1APM0 R&T Lab. Installation Instructions Installation instructions and additional components are located inside the interceptor. Read all instructions prior to installation. hhls interceptor is intended to be installed by a licensed plumber in conformance with all local codes. r � r it INSTALLATO / %= 0 9 o a INST1110 : When Installing Interceptor Inside If your dishwashing sink(s) discharges into a floor drain/sink (drain), you must regulate the flow into the drain to avoid an overflow of water, onto the kitchen floor. This can be done by installing a valve or flow restriction r, < I that discharges i i w ca on the slnf I n into the drain wee drawing bolo P pipingg for guidance. For, detailed guidance on indirect connections, go to Hydrostatic Slabs (or Pressure Slabs) When installed under, a hydrostatic slab (slab designed to withstand upward lift, usually caused by hydrostatic pressure) interceptor must be enclosed in a watertight concrete vault. Failure to follow this guidance voids your warranty. __ ....... i�l concrete slab (_In I� subject to _ I terceptor hydrostatic pressure I °I Y �i watertight concrete vault High Temperature Kitchen Water If water is entering the interceptor at excessive temperature (over 140' F), a drain water' tempering valve (DTV) must be installed. Most state and local plumbing codes prohibit water above 140° F being discharged into r, � the sanitary sewer. r Water above 1400 F will weaken or deform PVC Schedule 40 pipe, poly drainage fixtures like if and erode the coating of cast iron (leading to eventual failure) Failure to follow this guidance voids your warranty, high temperature drain water effluent (> 140° F) Compering valve (DTV) I_ l' cold water supply lineEI-Itercelptor High Water Table Installations Interceptors and risers are not designed to withstand water table height in excess of the top of the unit when buried (see figure). If it is possible for this to occtr, install the interceptor, and risers i a water, Light concrete vault or , baC kfill with concrete or flowable fill ( wet concrete and flowable backfill should be poured in stages to avoid crushing the Interceptor). At risk areas include but are not limited to tidal surge areas, fI adal Ins and areas l at receive storm water. Failure to follow this guidance voids your warranty, Models GB-50, GB-75, and GB-250 that are direct buried in high water - table scenarios must be installed with model AM anchor kit or warranty is void. page 2 of 3 TABLE 1 - Test Results Der ASME Al 12.14.3-2000 (Reaffirmed 200411 "GB2-2" Grease Interceptor INCREMENTAL ACCUMULATED Test No. Grease Sink Water Sink Drop Time sec Flow Rate (GPM) Lbs added Lbs skimmed Lbs retained Efficiency N Lbs added Lbs skimmed Lbs retained Efficiency N 1 1 2 111 35.9 7 0.00 7.00 100 7 0.00 7.00 100 2 2 1 112 35.6 7 0.00 7.00 100 14 0.00 14.00 100 3 1 1 2 110 1 36.3 7 0.02 6.98 99.7 21 0.02 20.98 99.9 4 2 1 112 35.6 7 0.04 6.96 99.4 28 0.06 27.94 99.8 5 1 2 111 35.9 7 0.05 6.95 99.3 35 0.11 34.89 99.7 6 2 1 112 35.6 7 0.05 6.95 99.3 42 1 0.16 41.84 996 7 1 2 111 35.9 7 0.05 6.95 99.3 49 0.21 48.79 99.6 8 2 1 112 35.6 7 0.06 6.94 99.1 56 0.27 55.73 99.5 9 1 2 111 35.9 7 0.05 6.95 99.3 63 0.32 62.70 99.5 10 2 1 111 35.9 7 0.04 6.96 99.4 70 0.36 69.64 99.5 11 1 2 112 35.6 7 0.07 6.93 99.0 77 0.43 76.57 99.4 12 2 1 112 35.6 7 0.05 6.95 99.3 84 0.48 83.52 99.4 13 1 2 112 35.6 7 0.06 6.94 99.1 91 0.54 90.46 99.4 14 2 1 112 35.6 7 0.06 6.94 99.1 98 0.60 97.40 99.4 15 1 2 112 1 35.6 7 0.05 6.95 99.3 105 0.65 104.35 99.4 16 2 1 112 35.6 7 0.07 6.93 99.0 112 0.72 111.28 99.4 17 1 2 112 35.6 7 0.07 6.93 99.0 119 0.79 118.21 99.3 18 2 1 112 35.6 7 0.08 6.92 98.9 126 0.87 125.13 99.3 19 1 2 111 35.9 1 7 0.10 6.90 98.6 133 0.97 132.03 99.3 20 2 1 112 35.6 7 0.10 6.90 98.6 140 1.07 138.93 1 99.2 21 1 2 112 35.6 7 0.11 6.89 98.4 147 1.18 145.82 99.2 22 2 1 112 35.6 7 0.14 6.86 98.0 154 1.32 152.68 99.1 23 1 2 113 35.3 7 0.12 6.88 98.3 161 1.44 159.56 99.1 24 2 1 113 35.3 7 0.16 6.84 97.7 168 1.60 166.40 9 ;.0 25 1 2 113 35.3 7 0.16 6.84 97.7 175 1.76 173.24 99.0 26 27 2 1 1 2 113 112 35.3 35.6 7 7 0.13 0.16 6.87 6.84 981 97.7 182 189 1.89: 2.05 .180.11 186.95 99.01 98.9 28 1 2 1 1 112 35.6 1 7 0.15 6.85 97.9 196 2.20 193.80 98.9 Performance Requirement Rating Report No. 1757-18018 Page 10 of 11 SPECIFICATION Notes 1. 4" FPT inlet/outlet with 4"x3" FPT fittings. 2. Unit. weighs: 49 lbs. (wet weight 216 lbs.) each 3. Capacities 1_iquid: 20 gal. each @35 GPM- Grease: 180 lbs. (24.6 gal.) 4. Built in flow control. S. For gravity drainage applications only. 6. Do not use for pressure applications, 7. Cover placement allows full access to tank for proper maintenance. 8. Vent not required unless per local code. 9. Engineered inlet and outlet diffusers are removable to Inspect/clean piping. 10.Integral air relief/ anti -siphon. Engineer Specification Guide Schier Great BasinT" grease interceptor model #GB2 shall be lifetime guaranteed and made in USA of seamless, rotationally -molded polyethylene. Interceptor shall be furnished for above or below grace installation. Interceptor shall be certified to ASME A112.14.3 (type C) and CSA B481.1, with field cut riser system, built-in flow control, built in test caps and three outlet options. Interceptor flow rate shall be 35 GPM. Interceptor grease capacity shall be 180 lbs. @ 35 GPM. Cover shall provide water/gas-tight seal and have minimum 450 lbs. load capacity. Certified Performance Great Basin'" hydromechanical grease interceptors are third party Iaerfornance tc d and listed � IAPM O #All214.3 and CSA B4 11 r r S B ease interceptor tier standards and 9 p greatly exceed requirements fo r grease separation and storage I hey are compliant to the Uniform Plumbing Code, the National Standard Plumbing Code, the National Plumbing Code of Canada, and the International Plumbing Code. UPC No R 35" • Outlet "A" (Options]) ... __..__.._._._._ Shown with optional ....✓.................. °000°°oo pumpout port kit A o000 _......... ,04o ............... '...... o00o a A 23° .:::::::::.-.. Inlet �o°o°o°o =_ q°O°OOgOq ._..---......__.._....... O O O o __:^ �,Outlet , _.. .. 0 O°O °O O O O ............... "B„ (Standard) 04040i O 00-�- Outlet foot. oeoo oaoaoeoe - o 00 o eo must face this _....... _..... Outlet , C, direction in all configurations (Optional) _ 12-7/16" CL of plain end inlet and outlet {� 5 ... - ........... . _.... 13-9/4" - 8-3/4" 0 21-1/2" Cover -j ""See Note #10 U1!1NEII& " ( 6-3/4°invert ........... dinlet -..... Static water diffuser line "7-1/4" invert when using 4"xT fittings page 3 of 3 � o rn ;a o m Z oN J = o CO C� mu '0 Zw oQ to �a Ccc Z',M o°-°a C � "ta U WO d O •� 0Z.LUX�!C �a Jzw In < D W Ww <F:.Z C co w rn¢-z� M a W C In 0 C� as L'� _C � b F-Z0a J rt•• • a% 0 �ZzJ M _ _NNN_ W ­4Z0 0ZOz U U U -w -0 A -,0 all Z wJ�� UF .d Ud�ZZj •�„y FOm J_N w U w 0 Z0 _,E) UU m m � 0 O w UU � .H _1� DO L WV m pE, � F-2Q?X0 O .2 4. c v C 0 0 _O IH N � I J ILL. W J V J aa� � yco W A = ti .Fi 0 L N N 0 N,eyPP PPFI BFiF a° v o ° 18 ° e ° STATE OF o/�, Z O f NO. I REVISIONS DATE COMMISSION NO. CADD FILE NAME: ISSUED DATE: SCALE: DRAWN BY: DRAWING TITLE: SHEET NO. PLUMBING FLOOR PLAN OF P-02 SHEET iiJ