BCP18-1243-02PLUMBING GENERAL NOTES A. UNLESS OTHERWISE SPECIFIED ON THIS DRAWING CONTRACTOR SHALL REFER TO ORIGINAL LANDLORD SPECIFICATIONS FOR ALL APPLICABLE REQUIREMENTS, NOTES, DETAILS, CONSTRUCTION'S STANDARDS, ETC., COORDINATE WITH LANDLORD REQUIREMENTS PRIOR TO ORDERING AND/OR INSTALLATION OF ANY EQUIPMENT AND ACCESSORIES SHOWN. B. ALL WORK SHALL BE DONE IN ACCORDANCE WITH FLORIDA PLUMBING CODE 2017 EDITION 1. SITE INVESTIGATION: EXAMINATION OF CONTRACT DOCUMENTS AND SITE OF WORK; THE BIDDER IS REQUIRED, BEFORE SUBMITTING HIS PROPOSAL, TO VISIT THE SITE OF THE PROPOSED WORK AND FAMILIARIZE HIMSELF/HERSELF WITH THE NATURE AND EXTEND OF THE WORK AND ANY LOCAL CONDITIONS THAT MAY IN ANY MANNER AFFECT THE WORK TO BE DONE AND EQUIPMENT, MATERIALS AND LABOR REQUIRED THEREFORE. SINCE THE WORK INVOLVES EXISTING BUILDINGS, SYSTEM AND FACILITIES, SPECIAL CONSIDERATION SHALL BE GIVEN TO EXAMINATION OF WORKING CONDITIONS, EXISTING FACILITIES AND ALL BUILDING STRUCTURES TO FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITIONS. VARIATIONS IN ROUTING AND/OR CONSTRUCTION SHOULD BE ANTICIPATED BY THIS CONTRACTOR AND ARE EXPRESSLY INCLUDED AS PART OF THE WORK WHENEVER REQUIRED AT NO ADDITIONAL COST TO THE OWNER. IGNORANCE ON THE PART OF THE CONTRACTOR WILL IN NO WAY RELIEVE HIM OF THE OBLIGATION AND RESPONSIBILITIES ASSUMED UNDER THIS CONTRACT. 2. THE NATURE OF THE REMODEL TYPE CONSTRUCTION POSES SPECIAL PROBLEMS FOR THE DESIGN ENGINEERS AS WELL AS THE PLUMBING CONTRACTOR. EVERY EFFORT HAS BEEN MADE BY THE ENGINEERS TO SHOW AND IDENTIFY THE LOCATIONS AND TYPES OF EXISTING PLUMBING SYSTEMS. THE MAJOR PORTION OF THE PLUMBING SYSTEMS ARE AS SHOWN ON THE DRAWINGS HOWEVER DEVIATIONS MAY BECOME EVIDENT AS THE JOB PROGRESSES. PLUMBING CONTRACTOR SHALL PERFORM A FIELD VERIFICATION BEFORE BIDDING THIS PROJECT. 3. CONTRACTOR WILL BE RESPONSIBLE FOR COODINATING HIS DEMOLITION WORK WITH OTHER TRADES, AND TO PROTECT FROM DAMAGE EXISTING SYSTEMS TO REMAIN. 4. CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF EXISTING PIPES BEFORE COMMENCING TO WORK AND MAKE MODIFICATIONS AS REQUIRED WITHOUT ADDITIONAL COST TO THE OWNER. 5. ALL PIPING SHALL BE INSTALLED RECESSED IN BLOCK WALLS, CHASES OR PARTITIONS. 6. EXISTING PIPES SERVING AREAS NOT COVERED BY THIS CONTRACT BUT IN SERVICE AT THIS TIME SHALL NOT BE INTERRUPTED EXCEPT AS A TEMPORARY INTERRUPTION COORDINATED WITH THE OWNER AND LANDLORD. 7. PLUMBING CONTRACTOR SHALL PAY ALL FEES, INSPECTION AND CONNECTION CHARGES REQUIRED. 8. SHALL VERIFY ALLDIMENSIONSNI AT JOB STEOACE PRIOR TO FABRICATION CONDITIONSPAND INSTALLATION OF MATERIALS AND EQUIPMENT. 9. COORDINATE ALL WORK WITH OTHER TRADES. 10. MATERIALS TAND WORKMANSHIP NG CONTRACTOR HFOR AALL UPER PERIOD ONE ALL OYEARREE OF DEFECTS IN FROM DATE OF ACCEPTANCE. 11. PROVIDE SHOCK ABSORBERS SIZE, QUANTITY AND LOCATION AS PER P.D.I. STANDARDS. 12. PROVIDE SHUT-OFF VALVE FOR EACH GROUP OF FIXTURE AND EACH FIXTURE SUPPLY. 13. WHEREVER DISSIMILAR METALS ARE TO BE JOINED, A DIELECTRIC FITTING SHALL BE PROVIDED TO CONNECT BOTH TYPES OF PIPES. 14. CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE ALL ROUGH -INS WITH THE MANUFACTURER BEFORE MAKING ANY INSTALLATION. 15. POTABLE HOT AND COLD WATER SYSTEMS SHALL BE "LEAD FREE" WITH LEAD CONTENT NOT EXCEEDING 0.2 PERCENT FOR SOLDER AND FLUXES AND 8 PERCENT FOR PIPE FITTINGS, FIXTURES AND TRIM. CONTRACTOR SHALL VERIFY MANUFACTURER'S COMPLIANCE. 16. ALL POTABLE HOT AND COLD WATER SYSTEMS SHALL BE FLUSHED CLEAR, STERILIZED WITH AN APPROVED SOLUTION AND THROUGHLY FLUSHED OF ALL RESIDUAL SOLUTION AFTER FINAL PRESSURE TESTS AND WITH ALL TRIM AND CONNECTIONS INSTALLED. 17. PROVIDE SHUT-OFF AND VACUUM BREAKER TO ALL HOSE BIBBS AND FAUCETS WITH HOSE -END CONNECTIONS. 18. ALL, FLOOR DRANS SHALL 0AVE TRAP PRIMERS TO PROTECT THE SEAL OF THE TRAP. 19. PVC PIPING IS NOT ALLOWED IN RETURN AIR PLENUMS. IF RETURN AIR PLENUMS ARE USED, CONTRACTOR SHALL REPLACE ALL EXISTING PVC PIPING WITH CAST IRON OR COPPER PIPING. 20. DRAINAGE SYSTEM DESIGN IS BASED ON 1/8" PER FOOT MINIMUM FALL FOR PIPES 3" OR LARGER AND 1/4" PER FOOT MINIMUM FALL FOR PIPES 2" OR SMALLER, ANY DEVIATIONS SHALL BE APPROVED BY ARCHITECT/ENGINEER. 21. ALL VENT THROUGH ROOF OPENINGS SHALL BE OFFSETED TO A MINIMUM DISTANCE OF T-O" RAWNGSFOR ROOF FFLASHING. LEAD ROM PARRAPET WFLASHING ALL OR RWILL NOT OOF EBE ACCEPTED. C��L 22. DRAIN PIPES UNDER LAVATORIES SHALL BE INSULATED WITH PRE -MANUFACTURED SHALLEIN BE NOCSHARPOR ABRASIVEFLORIDA SURF SURFING ACESUNDER DAVATTORIES. THERE TEST TEE THREADED CLEANOUT k WALL C LEAN 0 UT N.T.S. ACCESS COVER AND FRAME FINISHED WALL SURFACE PLUMBING SPECIFICATION 1. GENERAL: MATERIAL SHALL BE NEW, UNUSED, BEST OF THEIR RESPECTIVE KINDS AND FREE FROM DEFECTS IN WORKMANSHIP; IN CONFORMANCE WITH THE LATEST PUBLICATIONS IN FORCE AT TIME OF BIDDING. 2. PIPE AND FITTINGS: A. DRAINAGE WASTE AND VENT PIPING INCLUDING: PVC DRAINAGE WASTE AND PIPING (DWV) CONFORMING TO ASTM D-2665 UNDERGROUND NO HHUB CAST IRON CISPI STANDARD 301 ABOVE GROUNb AND CAST IRON HUB, PLAIN END ((ASTM A-74 WITH NEO- ITSEAPPROVED BY ILOCALRAUTHORITIESAAND NOT TC3PBE)USEDSIN AIR WHEN RETURN PLENUM. B. DOMESTIC WATER SUPPLY PIPING: COPPER PIPE TYPE 'L' WITH BRONZE OR WROUGHT COPPER SOLDER JOINT FITTINGS, ASTM.B88-78. C. NOT USED D. STORM DRAIN PIPING: AS HEREIN BEFORE SPECIFIED FOR SANITARY SOIL, WASTE AND VENT PIPING. 3. JOINTS AND METHODS OF CONNECTION: A. DWV COPPER PIPE: JOINT WITH 95-5 TIN -ANTIMONY SOLDER, INSTALL PER MANUFACTURER'S RECOMMI-NDATIONS. B. TYPE 'L' COPPER TUBE: JOIN WITH 95-5 TIN -ANTIMONY SOLDER, INSTALL PER MANUFACTURER'S RECOMMENDATIONS. C. STEEL PIPE: a. THREADED JOINTS: AFTER CUTTING AND BEFORE THREADING, REAM ALL PIPE AND REMOVE BURRS. MAKE JOINTS WITH JOINT COMPOUND APPLIED TO MALE THREADS ONLY. b. FLANGED JOINTS: STANDARD WEIGHT, 150 P.S.I. STEEL, WITH APPROVED RED RUBBER GASKET OR NEOPRENE RUBBER GASKET, INSTALL AS PER MANUFACTURER'S RECOMMENDATIONS. 4. UNIONS AND FLANGES: A. COPPER PIPE: BRONZE UNIONS FOR 2 INCHES AND SMALLER. FOR 2-1/2 INCHES AND LARGER USE BRONZE FLANGED CONNECTIONS 150 POUND CLASS. B. DIELECTRIC UNIONS OR FLANGES: UNIONS SHALL MEET DIMENSIONAL REQUIREMENTS AND TENSILE STRENGTH OF PIPE UNIONS IN ACCORDANCE WITH FED. SPEC. WW-U-531 E. UNIONS OR FLANGES SHALL BE SUITABLE FOR REQUIRED OPERATING PRESSURES AND TEMPERATURE CONDITIONS. UNIONS SHALL HAVE METAL CONNECTIONS ON BOTH ENDS. ENDS SHALL BE THREADED OR SOLDERED TO MATCH ADJACENT PIPING. METAL PARTS OF UNION OR FLANGED SHALL BE SEPAREATED TO PREVENT CURRENT FLOW BETWEEN DISSIMILAR METALS. EPCO DIELECTRIC PIPE FITTINGS OR EQUIVALENT. 5. ESCUTCHEONS: CHROME PLATED OR STAINLESS STEEL WITH SET SCREWS FOR HOLDING SECURELY IN PLACE. USE ESCUTCHEONS ON PIPES PASSING THROUGH WALLS, FLOORS AND CEILINGS OF FINISHED AREAS. 6. PIPE INSULATION: A. ALL CONDENSATE LINES SHALL BE INSULATED WITH 3/4" FIRE RETARDANT ARMAFLEX INSULATION WITH A MAXIMUM OF 25/50 FLAME SPREAD AND SMOKE DEVELOPED RESPECTIVELY. B. ALL HOT WATER AND RECIRCULATING WATER LINES SHALL BE INSULATED WITH 1" FIRE RETARDANT AP,MAFLEX !NSULATION WITH A MAXIMUM OF 25/50 FLAME SPREAD AND SMOKE DEVELOPED RESPECTIVELY. 7. INSTANT -FLOW WATER HEATERS SHALL BE OF THE CAPACITY AND ELECTRICAL CHARACTERISTICS INDICATED ON PLANS AS MANUFACTURED BY CHRONOMITE LABORATORIES,INC. 8. TRAP PRIMER SHALL BE SELF PRIMING TYPE ON COLD WATER SUPPLY LINE AS MANUFACTURED BY PRECISION PLUMBING PRODUCTS, INC. "PRIME -RITE" #PR-500. WHEN TWO OR MORE TRAPS REQUIRE PRIMING PROVIDE WITH DISTRIBUTION UNIT #DU-2, 3 OR 4 AND SUPPLY TUBE SS-8 ASSEMBLY. PROVIDE ACCESS PANEL AND INSTALL AS PER MANUFACTURER'S RECOMMENDATION. 9. FLOOR DRAINS: AS MANUFACTURED BY JOSAM. A. FD-1: JOSAM 30000-A SERIES WITH 6"x6" SQUARE NIKALOY TOP AND 1/2" TRAP PRIMER CONNECTION. NUT _VIS HAN PIPE 0.1 U'La,TION PIPE I& LATIC �- sADULt PIPE GALV. SH!ELD PIPE W/ INSULATION W/OUT INSULATION PIPE HANGERS-CLEVIS TYPE DETAIL N.T.S. FINISH FLOOR EXTENSION - SAME SIZE AS SEWER UP TO 4" DIA. --� `-DIRECTION OF FLOW INTERIOR F OCR CLEAN 0 UT 4X4X3X3-inch Double Sanitary Tee (support Is �Cleanout Cover required) 3-inch Grease Waste line 6-inch Min. NOTE: 4-inch Cap -/ SAMPLING PORT SHALL BE ACCESSIBLE AT ALL TIMES WITHOUT HAVING TO REMOVE ANY MERCHANDISE AND WITHOUT STANDING WATER ON GROUND SURFACE; WITH A MINIMUM 36 INCHES HORIZONTAL CLARENCE FROM ANY WALL, FIXED EQUIPMENT OR STORED MATERIALS AND MINIMUM 48 INCHES VERTICAL CLEARANCE FROM ANY FIXED EQUIPMENT OR STORED MATERIALS. SAMPLING POINT DETAIL N.T.S. PLUMBING LEGEND SYMBOL DESCRIPTION - - COLD WATER LINE (CW) HOT WATER RECIRC. (HWR) CONDENSATE DRAIN LINE CD - - HOT WATER LINE (HW) SANITARY WASTE LINE (SAN) SANITARY VENT LINE (V) - - -{��- - - CHECK VALVE -� FCO FLOOR CLEAN OUT -Hi CO WALL CLEAN OUT - - ---D4- - - GATE VALVE �--� HB HOSE BIBB - - -®- - - VALVE IN BOX _ ___� VIV GATE VALVE IN VERTICAL oc- "P" TRAP WATER HAMMER ARRESTOR ABV. ABOVE BLW BELOW CEIL., CLG. CEILING FL. FLOOR F.U. FIXTURE UNIT (UG) UNDERGROUND V.T.R. VENT THRU ROOF VB VACUUM BREAKER TP TRAP PRIMER CONNECTION (NEW TO EXISTING) NOTE: SYMBOLS INDICATED MAY NOT BE USED ON DRAWINGS GREASE TRAP FLOW CALCULATION: BASED ON FPC PDI-G101 FIXTURE VOLUME (CU. INCHES) LOADING GPM FACTOR HAND SINK (GROUND) 9"X9"X4" = 324 0.75 1.05 3-COMP SINK 3(18"X18"X12") = 11664 0.75 37.87 38.92 DRAINAGE PERIOD = 2 MINUTES SINK FLOW RATED = 38.92 GPM /2 19.46 19.46 PUMP OUT FREQUENCY CALCULATION: COFFEE SHOP. GREASE PROFDUCTION FACTOR = 0.025 LB/MEAL # OF TAKE OUT MEALS/DAY = 50 LB GREASE PER DAY = 50 MEALS /DAY X 1 MEALS/DAY X 0.025 = 1.25 LBS. LB GREASE PER MONTH = 1.25 LBS./DAY X 30 = 37.5 LBS. POF = 30 DAYS PLUMBING SCHEDULE ITEM DESCRIPTION WATER WASTE WASTE GAS 0 0 IV m o z � � 1- HAND SINK 1 /2" 1 /2" 1 1 /2" - - - 2 3-COMPARTMENT SINK 1 /2" 1 /2" - 1 1 /2" - - 2" VENT PORT FCQ SANITARY PIPING ISOMETRIC N.T.S. j/2" HAND 3/4" SINK z�� < WATER HAMMER IO �� ARRESTOR / /2" 1/2" 3-COMPARTMENT SINK DOMESTIC WATER PIPING ISOMETRIC N.T.S. FOG 2.0 ER -DER FOG Control Device (FCD) Installation Inspection Approval Date: Inspector: DERM's FCD Installation Inspection Required Prior to Plumbing Final for all Municipal projects. Failure to secure DERM's FCD Installation Inspection will result in disapproval of Final Inspection by the Municipal Building Official, pursuant to Section 24.42-6, MDC Code. To schedule DERM's FCD Installation inspection for Municipal projects please send an email to iFOG2t?a miamidade.gov, 24 hours prior to desired date. Provide DERM plans process M-number, complete address of the site, folio number, and contact person name and phone number. upoa[ w"./..." 2 0 EXISTING BATHROOM 3" SAN. 1 W iiYW- iY• W Y WYrrr -YWW W Y W V W Y 6r W W W W Y w Y W W W W W w W W W WWWIJY W W W. W Y W W d r r r Y Y W V WVW r ® • Y.Y YY � - Y Y. r •-r b r r Y- Y •. .r • b' r r Y Y Y W W b Y Er W Y iv W W W W Y W W W u u u ar W v� Y W u W W- ., ue W W W dW.. II I ,1 3/4"CW SAMPLING PORT 1/2"HW WORK AREA1 x f -HUB ORAIN REFERENCED NOTE: 1O SOLID INTERCEPTOR. AARDVARK MODEL O AA-M-35. O2 GREASE INTERCEPTOR SCHIER MODEL JGB2-2, 180 LB GREASE CAP. H P'LUMBING FLOOR PLAN SCALE ...=1.0" R Cy o o m z J O° �_ J = R5 � Of .2 Ali li z W Q1 ica ��`j 00 Ua °�wCD Z C co FF DTI Up0 •� 0 x w aQN IW A a: N wow p�2 N < <Z,- ws z ooo z Cd .�.a z < J N, �J y .� �z�JaV {ID YF-U 'z ' J W A M r�iZ WOU V7 Oa=zz= h m J- L" NUmWD z:, W J N U U m�<oo _ U U O In °wa�w� Q2 �_<'KU o c v 7 N C 0 U Z O � Q N_ J Z J L Q L _J V J a UJ Co co WV 0 a) a� '� 0 c 3 0_ O 9 ,�0/111 tl//tl @ 0�'t^V mmmmm���P4O�o ®�\CEQm� '< .560 • O - ®.l STATE OF On � ®mmmmm® G NO. I REVISIONS I DATE COMMISSION NO.: 1 dx 1..... oiw .:.,/,AK._