17-548-04ELEVATOR RECALL WIRING Elevator Machine Room Smoke Detector and Heat Detectors on Elevator Lobbies connected to activate Fire Fighter's Service Recall ThirdII Blil FlaLwtWBY II O / SO Second Floor Lobby 1 Elevator Cabinet First] Floor Lobby 11 Note: Heat Detectors or Smoke Detectors are not allowed in elevator pit area ELEVATOR RECALL fiYS1Bd 1"QL� Existing Smoke Detector located at F.A.C.P. Elevator Fire Fighters' Service Recall Wiring and Control Relays QQ Elevator Machine Room Smoke Detector connected to activate Fire Fighters' Service Recall ® Elevator Lobby Heat Detectors connected to activate Fire Fighters' Service Recall Addressable FACE. ELEVATOR RECALL - SEQUENCE OF OPERATIONS \ A. Heat Detectors on elevator lobbies and Smoke Detector in elevator mach ne room shall: I . Initiate and alarm condition at the fire Alarm System. 2. Initiate the recall of the elevator cars as follows in accordance with NFPA 72 Chapter 2 1 .3. 1 2 (20 10 Edition) B. PHASE I RECALL: Activation of any elevator hobby heat detector located on 2nd floor or 3rd floor shall initiate phase I recall which bring the elevator car to the I st floor and lock the doors in the open position. C. PHASE II RECALL: Activation of the heat detector located on the I sit floor elevator lobby and / or activation of the Smoke Detector located in the Elevator Room shall initiate phase II recall which will bring the elevator car to the 2nd floor and lock the doors in the open position. D. ELEVATOR WARNING SIGNAL: Activation of the elevator machine room smoke detector detector shall also initiate the elevator warning signal to alert emergency personnel that the elevators are not safe for use,as required by NFPA 72 Chapter 21 ..3. 1 2.3 (20 1O Edition). E. SHUNT -TRIP HEAT DETECTOR: N/A FLOW BFILL NOTE5: FLOW BELL SHALL SOUND UPON ACTIVATION OF FLOW SWITCH. FLOW BELL SHALL SOUND AS LONG AS WATER 15 FLOWING. FLOW BELL SHALL NOT BE CAPABLE OF BEING SILENCED FROM F.A.C.P. ,,--(D s NOTES: A. CEILING HEIGHT: +/ 10, - 0". (SMOOTH CEILING) . B. TH15 15 AN EXISTING'iREMOTE 5UFERVr51NG'"STATION-Fitz€ ALARM SYSTEM' AND SHALL BE PROVIDED WITH 24 MRS. OF SECONDARY POWER SUPPLY. METHOD OF COMMUNICATION: TELEPHONE LINES. C. BUILDING 15 FULLY SPRINKLfD,'(q ELEVATOR SHAFT AND ELEVATOR MACHINE ROOM). D. THIS 15 AN EXISTING 3 STORY BUILDING WITH 3,345 5QFT. TO BE ADDED (SCOPE OF WOR- E. ALL NACs SHALL BE CLA55 B. F. THE 5LC SHALL BE CLA55 B. SEQUENCE OF OPERATION: SMOKE DEFECTOR Activation of Smoke Detector shall initiate the following functions: - Generate an audible signal at the Fire Alarm Control Panel - Generate an audible signal simultaneously on all areas of the building by means of Horn devices. Generate a visual alarm signal simultaneously on all areas of the building by the use of Strobe devices or combination Horn/Strobe notification device. - Indicate the location of the Smoke Detector by displaying the alarmed device and its location on the Fire Alarm Control Panel. - Transmits a Fire Alarm Signal to the designated Central Station. HEAT DETECTOR Activation of Heat Detector shall initiate the following functions: - Generate an audible signal at the Fire Alarm Control Panel - Generate an audible signal simultaneously on all areas of the buildincg by means of Horn devices. Generate a visual alarm signal simultaneously on all areas of the building by the use of Strobe devices or combination Horn/Strobe notification device. - Indicate the location of the Heat Detector by displaying the alarmed device and its location on the Fire Alarm Control Panel. - Transmits a Fire Alarm Signal to the designated Central Station. MANUAL PULL STATION Activation of Pull Station shall initiate the following functions: - Generate an audible signal at the Fire Alarm Control Panel - Generate an audible signal simultaneously on all areas of the buildmg by means of Horn devices. Generate a visual alarm signal simultaneously on all areas of the buildmg by the use of Strobe devices or combination Horn/5trobe notification device. - Indicate the location of the Pull Station by displaying the alarmed device and its location on the Fire Alarm Control Panel. - Transmits a Fire Alarm Signal to the designated Central Station. DUCT DETECTOR Activation of Duct Detector shall initiate the following functions: - Generate an audible supervisory signal at the Fire Alarm Control Panel. - Indicate the location of the Duct Detector by displaying the activated device and its location on the F.A.C.P. - Shut Down the AHU. - Transmits a Supervisory Signal to the designated Central Station. WATERFLOW DEFECTOR Activation of Waterflow shall initiate the following functions: - Generate an audible signal at the Fire Alarm Control Panel - Generate an audible signal simultaneously on all areas of the building by means of Horn devices. Generate a visual alarm signal simultaneously on all areas of the building by the use of Strobe devices or combination Horn/5trobe notification device. - Indicate the location of the Waterflow by displaying the alarmed device and its location on the Fire Alarm Control Panel. - Activate the outdoor Flow Bell. - Transmits a Fire Alarm Signal to the designated Central Station. TAMPER SWITCH Activation of Tamper Switch shall initiate the following functions: - Generate an audible supervisory signal at the fire Alarm Control Panel. - Indicate the location of the Tamper Switch by displaymg the activated device and its location on the F.A.C.P. - Transmits a Supervisory Signal to the designated Central Station. TROUBLE Any abnormal condition in the System shall initiate the following functions: - Generate an audible Trouble Signal at the Fire Alarm Control Panel. - Indicate the cause of the trouble by displaying the abnormal condition on the Fire Alarm Control Panel. - Transmits a Trouble Signal to the designated Central Station. FIRE ALARM COMMUNICATOR - All signals shall be reported directly to the designated Central Station via Telephone line. LEGEND 0 - FIRE LITE MS9200 W/UDAT ADDRESSABLE FIRE CONTROL PANEL - FIRE LITE FCPS-24FSB POWER SUPPLY ® - FIRE UTE SD350 INTELLIGENT PHOTO SMOKE DETECTOR ❑* - FIRE LITE BG-12LX ADDRESSABLE PULL STATION 51 - FIRE LITE BG-12LOB (WP) PULL STATION W/MODULE ® - EDWARDS 281B HEAT DETECTOR -® - SYSTEM SENSOR DH 100 ACDC DUCT DETECTOR M❑ - FIRE LTTE Mimmol ADDRESSABLE MONITOR MODULE ® - FIRE LITE CRF300 ADDRESSABLE RELAY MODULE ® - SYSTEM SENSOR S1224MC STROBE LIGHT wp ® - SYSTEM SENSOR S1224MCK (WP) STROBE EIGHT I0g - SYSTEM SENSOR P1224MC 75 CD HORN STROBE ++ - SYSTEM SENSOR P1224MC 110 CD HORN STROBE IF 90 - SYSTEM SENSOR P1224MCK (WP) 75 CD HORN STROBE TD - TAMPER SWITCH BY OTHERS [j] - WATERFLOW DETECTOR BY OTHERS E - EXISTING DEVICE WP - OUTDOOR LISTED DEVICE NEW DEVICES wp I - SYSTEM SENSOR P2RK (WP) MULTICANDELA HORN STROBE SYSTEM SENSOR SR/SCR MULTICANDELA STROBE LIGHT Q - SYSTEM SENSOR SR/SCR MULTICANDELA STROBE EIGHT 0 - FIRE LITE BG-12LOB (WP) PULL STATION W/MODULE NEW - NEW DEVICE M System No. W-L-1413 February 07, 2007 3 F-Rating - 1 and 2 Hr (See Item 1) T-Rating - 0 Hr A 1 3 3 2 2 iC 1B A Section A A 1.Wall Assembly -- The 1 or 2 hr Hire -rated gypsum wallboard/stud wall assembly shall be constructed of the materials and in the manner specified in the individual U400 or V400 Series Wall and Partition Design in the UL Fire Resistance Directory and shall incorporate the following construction features: A. Steel Studs - "C-H" or 'C-T" shaped studs, min 2-1/2 in (64 mm) wide by 1-1/2 in (38 mm) deep, fabricated from min No. 25 gauge (0.6 mm thick) galy steel, spaced max 24 in (610 mm) OC. B. Gypsum Board* - 1 in. (25 ram) thick, 24 in. (610 mm) wide gypsum liner panels installed vertically. Max. diam of circular cutout in gypsum liner panel is 10 in.(254mm) C. Gypsum Board* - 1/2 in. or 5/8 in. (13 or 16 mm) thick, 48 in. (1.2 m) wide gypsum boards. The gypsum board type, thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual Wall and Partition Design. Max diam of circular cutout in gypsum board is 10 in.(254mm). The hourly F Rating of the ftrestop system is equal to the hourly fire rating of the wall assembly in which is installed. 2.Through-Penetrants -- One metallic pipe, conduit or tubing to be installed either concentrically or eccentrically within the fiirestop system. The annular space between pipe, conduit or tubing and periphery of opening shall be minimum 0 in. (0 ram, point contact) to max 2 in. (51 ram). Pipe, conduit or tubing to be rigidly supported on both sides of wall assembly. The following types and sizes of metallic pipes, conduits or tubing may be used: A Steel Pipe - Nom 8 in (203 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe B. Iron Pipe - Nom 8 in. (203 mm) diam (or smaller) service weight (or heavier) cast iron soil pipe, nom 8 in. (203 mm) diam (or smaller) or Class 50 (or heavier) ductile iron pressure pipe. C. Conduit - Nom 6 in diam (152 mm) diam (or smaller) steel conduit or nom 4 in. (102 mm) diam (or smaller) steel electrical metallic tubing. D. Copper Tubing - Nom 6 in. (152 mm)diam (or smaller) Type L (or heavier) copper tubing E. Copper Pipe - Nom 6 in. (152 mm) diam (or smaller) Regular (or heavier) copper pipe 3. Fill, Void or Cavity Material* Caulk as sealant - Min 1 in. (25 mm) thickness of Hill material applied within the gypsum board liner panel flush with the faces of the liner panel. Min 5/8 in. (16 mm) thickness of fill material applied within the gypsum board annulus, flush with the finished side of the wall. Min 1/2 in. (13 mm) diam beadof caulk applied to penetrant/gypsum board interface at the point contact location on the finished side of the wall 3M COMPANY - CP25WB+ Caulk or FB-3000 Wr Sealant *Bearing the UL Classification Mark GENERAL NOTES I . THESE UNITS OR DEVICES SHALL BE INSTALLED USING APPROVED MATERIALS AND WIRING PRACTICES IN ACCORDANCE WITH THE N.E.C. # 70 AND THE NATIONAL FIRE PROTECTION ASSOCIATION ARTICLE # 7GO POWER LIMITED SECTION AND ALL APPUCA13LE LOCAL WIRING ORDINANCES. 2. CONDUCTORS AND CABLES FOR USE WITH THIS POWER LIMITED FIRE ALARM SYSTEM SHALL BE INSTALLED IN ACCORDANCE TO THE NATIONAL FIRE PROTECTION ASSOCIATION ARTICLE # 7GO POWER LIMITED SECTION AND SHALL BE LISTED POP THIS USE. CONDUCTORS SHALL HAVE A MINIMUM RATING OF 300 VOLT5 AND SHALL BE OF SOLID COPPER OR BUNCH -TINNED 5TRANDED COPPER CONDUCTOP.5. 3. ALL NEW WIRING INSTALLED IN DUCTS, PLENUMS AND OTHER SPACES USED POP ENVIRONMENTAL AIR SHALL BE TYPE FPLP, AS PER N.E.C. ARTICLE # 7GO-G I . 4. FPLP OR FPLP SIGNAL CABLE FOR USE IN ACCORDANCE WITH N.E.C. ARTICLE 7GO AND N.E.C. ARTICLE 725 CLA55 2 OR 3 CIIRCUIT. 5. MINIMUM CABLE 51ZE: - # I G AWG COPPER (# 18 FPL OR FPLP) FOR INITIATING CIRCUITS - # I G AWG COPPER (# I G FPL OR FPLP) FOR NAC5. G. CONDUCTORS USED IN DUCTS OR PLENUM CEILINGS FOR ENVIRONMENTAL AIR SHALL EMPLOY THE USE OF ELECTRICAL METALLIC TUBING OR PLENUM TYPE CABLE WHICH MEETS THE REQUIREMENTS OF THE NATIONAL PROTECTION ASSOCIATION AND ARE U.L. LISTED OR COMPATIBLE FOR THI5 USE. 7. CONDUIT FILL: 41 % OR LESS. 8. PENETRATIONS: AS NOTED ON DETAIL 9. THE LOCATION OF AUDIBLE DEVICES SHALL BE DESIGNED TO BE EFFECTIVELY HEARD 15 dB. ABOVE AMBIENT N015E LEVEL OBTAINED UNDER NORMAL CONDITION OF OCCUPANCY AS PER ARTICLE 7.4.2 OF THE NFPA 72 (2007 EDITION). 10. PULL STATIONS SHALL BE INSTALLED AY 48" (CENTER) A.F.F. AS PER ARTICLE 4.2.5 OF THE FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION 2007 EDITION. I I . ALL SMOKE DETECTORS SHALL BE MOUNTED MORE THAN 3'-0" FROM A/C DIFFUSERS. System No. C-AJ-1044 March 15, 2007. F-Rating-2,3 and 4 Hr (See Items 2A and 4) T-Rating - 0 Hr L-Rating at Ambient - Less than 2 CFM/sq ft L-Rating at 400 F - Less than 1 CFM sq ft W-Rating - Class 1 (See Item 4) 1. Floor or wall Assemby - Lightweight or normal weight(100-150 pef or 1600-2400 Kg/m3) concrete. Except as noted in table under item 4, min thickness of solid concrete floor or wall assembly is 4-1/2 in. (114mm). Floor may also be, constructed of any min 6 in.(152mm) thick UL Classified hollow core Precast cconcrete UP*. when (Ioor 1s, co istucted 4f hollow core recast concrete inits, packin mate at (Item 3) and caulk fill molar al (item 4/ to be installed mmetricaI on both sides of floor, flush with tlor surface. Wall assembly may also be constucted of any UJ7 CI ssifi ncrete Blocks*. Max diam of opening in solid lightweight or normal weight concrete floor is 32 in a(813mm . x diam of opening in floor constructed of See Concrete Blocks (CA2D and Precast Concrete Units (C categories in the Fire Resistance Directory for names of manufacturers. 1ASteel Sleeve -(Optional, Not Shown)-Nom 16 in (406mm) diam (or smaller) Schedule 10 (or heavier) steel sleev cast or grouts c( int floor or wall assembly. Sleeve may extend a max of 2 in (51mm� above top of floor or beyond either surface of wallAs an aRemate, nom 16 in (406mm) diam (or smaller) min 0.028(0.71mm) thick galvanized sheet sleeve cast or grouted into floor or wall assembly flush with floor or wall surfaces. 2. Througyh Penetrants -One metallic pipe, conduit or tubing to be installed either concentrically or eccntrically within Ore fire stop system.Mox annular space be between pipe, conduit or tubing and sit a oT through opening or skieve is depeglmt on the parameters shown in item 4.Min annular space between pipe or conduit and edge of through opening is 0 m M contact). Max annular space to be as shown in the table in item 4.15 l , conduit car tubing to be rigidly supported on both sides of floor or wall assembly. The following types and sizes of metalilicc pipes, conduits or tubing may be used: A. Steel Pipe-Nom 30in.(762mm) diam (or amaller) Schedule 10 (or heavier) steel pipe. t B. Iron Pipe-Nom 30in.(762mm) diam (or smaller) cast or ductile iron pipe. C. Conduit-Nom 6 in.(152mm) diaor smaller) rigid steel conduit.. D. Conduim -Nom 4 in.(102mm) diam (or smaller) steel electrical metallic tube. E. Copper Tubing -Nam 6in.(152mm) diam (or smaller) Type L (or heavier) copper tube. F. Copper Pipe-Nom 6 in.(152mm) diam (or smaller) Regular (or heavier) copper pipe. 3. Packing Material-Polyethlene backer rod or nom 1 in.(25mm) thickness of thighly-packed mineral wool halt or glass bb{r innrlafian firm) paced iMo opgnn gs permanent fa�m.Poclang mot�al tt lie recessed from Op IMoce of,icaat or fro o h surfaces o war( requi o ocoommo ate the required hickness of call fi motena )item 4 3AFormin Material* -As an alternate to the packingg material in Item 3, nom 4 in.(102mm) wide strips of min 1/2 in 113mm) thick compressible mat to be stacked to a thi kn� greater than the width ad the annula and compresson-filled edge -first, to 111 the annular space to a min 4 in.�102m rl As an option, the i psi of mithn e1 f 2 in 13mm) thin corn re3nble t a e diod fi11�� 'Rnu i hwise, girl stgdep)d, to by th�p grater t an the of annular s ce an comp on-ff space a mm in (1mm op of smog I to recessed rom top surface of floor or rom both surfaces of wall as necessary to accommodate the required thickness of caulk fit material. 3M COMPANY -Fire Barrier Packing Material 4. RII, Void or C�Material-Caulk, Sealard-Applied to fill annular space flush with the top surface of floor. In wall assembly requred caulk to be installed symmdricalp on both sides of wa ,flush with all surface. At int contact location between penetrant and skeve or betwween penetrant and concretes a min 1%4 in.(6m� diam bead of caulk shall be applied ast top surface of fiber and at both surfaces of wall. The handy F ratings and the min requ caulk thiclalesses are dependent upon a number of parameters as shown in the following table: Min Floor (r ) II Nom Pipe TubeorMax Annular ) in out ) RaF Hr Thkm In min Conduit Diann In min Space In. min Th s n ram 2-1 /2 64 1 /2-12(13-305 1-3/8 35 1 /2 13) 2 2-1/2 643 1/2-12(13-3053 3-1/4 83 1 2) 2 4-1 12 114 1/2-6(13-152� 1-3/8 35 1� {g) Q) 2 4-1/2 114 1/2-1 13-30 1-1 4 32 ( 1 3 4-1/2 114 1/2-20 13-508 2 51 25 3 4-1/2 114 1/2-20(7r(13-508 2 51 1 25 3 4-1/2 114 1 2-0 558-305 3-1/4 83) 1 5 3 4-1 2 114 2 3 (2 ) ( 22$�j 5-1/2 140 1//2-6(13-152� 1-3�81 35) 1(2�(b) 4 Da;Min 2 in.(51mm) thickness of mineral wool bait insulation of forming material (Rem3A) required in annular space Min 1 in.(25mm) thickness of mineral wool bolt Insulation required in annular space of both sides of floor or wall assembly c)Min 1 in.(25mm) thickness of caulk) to be installed flush with each surface of floor or wall assembly 3M COMPANY-CP25WB+ or FB-3000 WT (Note: W Rating applies only when FB-30OWT is used) *Bearing the UL Classification Marking This material was extracted and drawn by 3M Fire Protection Products from the 2007 edition of the UL Fire Resistance Directory APPROVED MIAMWADE COUNTY FIRE DEPARTMENT / BLDG.PERMIT_ FIRE ALARM 'y FIRE SUPPRESSION_ WATER MAIN EXr. 12. WALL MOUNTED V15UAL DEVICES SHALL BE INSTALLED 80" A.F.F., CEILING MOUNTED VISUAL DEVICES SHALL BE INSTALLED AT A FIRE AL MAXIMUM HEIGHT OF 30' - 0" A.F.F. INSTAL( 13. ALL EQUIPMENT TO BE INSTALLED SHALL BE COMPATIBLE, NEW AND U. WITH LISTED FOR USE IN FIRE ALARM SYSTEMS. 14. THI5 SYSTEM SHALL BE POWER LIMITED AND ALL EQUIPMENT SHALL BE LISTED POWER LIMITED. 15. THE INSTALLATION OF THIS FIRE ALARM SYSTEM SHALL COMPLY WITH: FLORIDA FIRE PREVENTION CODE (FFPC) 5TH EDITION. PLORIDA BUILDING CODE (FBC) 2014 EDITION, NFPA I "FIRE CODE" 201 2 EDITION. NFPA 101 "LIFE SAFETY CODE' 20 12 EDITION. NFPA 72 "NATIONAL FIRE CODE' 2010 EDITION. NFPA 70 " NATIONAL ELECTRICAL CODE' 201 1 EDITION. I G. THI5 FIRE ALARM SYSTEM SHALL BE TOTALLY SUPERVISED. 17. CONNECTIONS (1 20 VOLTS) TO FIRE ALARM CONTROL PANEL SHALL BE ON A DEDICATED BRANCH CIRCUIT(5). THE CIRCUITS AND CONNECTIONS SHALL BE MECHANICALLY PROTECTED. CIRCUIT DISCONNECTING MEANS SHALL HAVE A RED MARKING. SHALL BE ACCESSIBLE ONLY TO AUTHORIZED PERSONAL AND SHALL BE IDENTIFIED AS "FIRE ALARM CIRCUIT". THE LOCATION OF CIRCUIT DISCONNECTING MEANS SHALL BE PERMANENTLY IDENTIFIED AT THE FIRE ALARM PANEL. 18. CONTROL PANEL AND POWER SUPPLIES, SHALL BE LOCATED IN A MECHANICALLY VENTILED ROOM. 15. THE MAXIMUM HEIGHT TO THE TOP OF THE CONTROL PANEL AND ANY INSTALLED POWER SUPPLY SHALL NOT EXCEED G' - O" A.F.F. 20. RECORD OF COMPLETION WILL BE PREPARED BY WORLD SECURITY 4 ELECTRIC, INC. AND COPY WILL BE PROVIDED TO THE OWNER AND TO THE CITY FIRE RESCUE DEPARTMENT. 2 1. THE FOLLOWING DOCUMENTATION WILL BE ON SITE UPON THE FINAL ACCEPTANCE TEST OF THE SYSTEM: - OWNER'S MANUAL AND INSTALLATION INSTRUCTIONS COVERING ALL SYSTEM EQUIPMENT. - RECORDED DRAWINGS. M SYSTEM TO BE IN ACCORDANCE PA 72: 70; 101 FIRE 8: SECURITY SYSTEMS 7963 N.W. 14th STREET DORM., FLORIDA 33126 TEL : 305.477.9640 FAX: 305.477.1083 vv w.WSEFS.com LICENSE #: EC-0001652 (J NornmER* by lh..yw"11 FnA erPrvr® ENGINEERING: Carlos Rodriguez, P.E. LIC. #65687 8101 S.W. 104th STREET MIAMI, FLORIDA 33156 Plat@NE: (786) 390-8213 O~ O A � x �D M W �zWa C aC F W Ao z M 610 F . . tN ~ O 7:11 A Z., U O t' Revisions: drawing by: L.C. design by: WSE date: 01.05.2017 project #: 17-0105 scale: as shown FIRE ALARM SYSTEM FA=4 sheet 4 of 4