Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
17-548-03
AUDIO 75 SHUT -DOWN • R CONTROL AV50 CONTROL BOOTH 31 32 — — — — — — — — — — — — — — — — — — — — — — — — — — BOOTH — — — — — — — — — — — — — — — — — — — — AN �Ya �Ya V mzo4msm�,�, DD DO DD HD • • M M M SD M THIRD FLOOR 25 26 27 28 29 30 37 THIRD FLOOR - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 75 wp 75 wP 110 75 75 75 75 Imp75 75 wP 75 75 75 N.A.C. # 2 (PS1) AV41 AV40 AV39 AV38 V37 V36 AV35 AV34 AV33 AV32 AV31 AV30 I Me 000 ��I IN . n I WP (75) wP 75 75 75 75 7575 77 V25 V24 AV23 V22 AV21 AV20 AV19 AV18 N.A.C. # 1 (PS1) •�•�• ����„ m�M 20 21 22 23 24 36 42 75 wP 75 wP 75 0.844 A / 3.0 MAX 75 75 N.A.C. # 4 (PS3) AV60 AV59 V58 V57 AV56 176mA 176mA 158mA 158mA 176mA #14/2 FPL CABLE _ — — — — — — — — — — — ------ or #14 THHN I75 wP 0.624 A / 3.0 MAX 75 15 15 75 N.A.C. # 3 (PSI) V68 V67 V66 AV65 V64 SECOND FLOOR 66mA 66mA 176mA 158mA - - - - -158mA SECOND FLOOR SCOPE OF WORK N.A.C. # 2 PS2 75 75 wP 75 - - 75 wP - 75 - - - 75 - - - - - - - - - - - - - - - - - - - 75 75)wp - - - - - - - - - - - - - - — — — — — r I�vvvvl PS-3 75 AV9 V10 AV11 AV12 AV13 AV14 AV15 AV16 AV17 0.400 A / 3.0 MAX 75 15 wP N.A.C. # 2 (PS3) I M SD • • I 2 75 75 WP 75 WP 75 75 75 75 WP 75 WP 41 40 45 44 158mA 66 1AVm1A N.A.C. # 1 (PS2) L — — — — I ---------------------- J #14/2 FPL CABLE AV1 AV2 AV3 AV4 AV5 AV6 AV7 AV8 or #14 THHN El 1W1T T 0.624 A 3.0 MAX WP 15 75 75 15 N.A.C. # 1 (PS3) #14/2 FPL CABLE/ WATERFLOW • SD • • • M M "—a]— or #14 THHN M M AV55 V54 V53 V52 V51 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 35 176mA 66mA 158mA 158mA 66mA E SLC INTELIGENT LOOP F.A.P.S. PS#3 F.A.P.S. PS#1 F.A.P.S. pS#2 I #18/2 F.P.L.P. (POWER LIMITED) FIRE CABLE. FIRE LITE FIRE LITE FIRE LITE FCPS-24FS8 FCPS-24FS8 FCPS-24FS8 FIRST FLOOR ± 2a we ± 2a we ± 2a we FP1 TELEPHONE LINES FIRST FLOOR #12 THHN - 1/2" C CAPACITY : 8.0 AMP NAC LOAD : 1.613 AMP 20 A DEDICATED CIRCUIT BREAKER W/LOCK 120 V 20 A 20 A 20 A DEDICATED CIRCUIT DEDICATED CIRCUIT DEDICATED CIRCUIT BREAKER W/LOCK BREAKER W/LOCK BREAKER W/LOCK 120 V 120 V 120 V CAPACITY : 8.0 AMP CAPACITY : 8.0 AMP NAC LOAD : 7.062 AMP I NAC LOAD : 3.777 AMP FIRE ALARM RISER DIAGRAM MAX. DETECTOR PER LOOP 99 MAX. MONITOR PER LOOP 99 SCOPE OF WORK CABLE USES AND PERMITTED SUBSTITUTIONS FOR POWER -LIMITED FIRE ALARM CABLES CABLE TYPE USE REFERENCES PERMITTED SUBSTITUTIONS FPLP POWER -LIMITED FIRE ALARM PLENUM CABLE 760.61 (A) CMP FPLR POWER-UMITED FIRE ALARM RISER CABLE 760.61 (B) CMP, FPLP, CMR FPL POWER-UMITED FIRE ALARM CABLE 760.61 (C) CMP, FPLP, CMR, FPLR, CMG, CM APPROVED MIAMI-DADE COUNTY FIRE DEPARTMENT BLDG.PERMIT__ RREALARNI✓/ FIRE SUPPRESSION_— WATER MAIN EXT. nATP. yl 21,7 - n m FORE & SECURITY SYSTEMS 7963 N.W. 14th STREET DORAL, FLORIDA 33126 TEL : 305.477.9640 FAX: 305.477.1083 www.WSF-FS.com LICENSE #: EC-0001652 @N®TIFIER' by ❑oc Ywell FM APPROM ENGINEERING: Carlos Rodriguez, P.E. LIC. #65687 8 10 1 S.W. 104th STREET MIAMI, FLORIDA 33156 PHONE: (786) 390-8213 61 � z OH O A � M r 1 V �zWa L r H Az°x F 0 z V V O s, a Revisions: ZL ZL drawing by: L.C. design by: WSE date: 01.05.2017 project #: 17-0105 scale: as shown FIRE ALARM SYSTEM FA=3 sheet 3 of 4