Loading...
17-548-02ATTIC ATTIC FLAT ROOF ®" ELEV ST. OPEN TO BELOW OPEN TO BELOW MEZZ. STAGE AUDITORIUM o = wy f�~ O om CORRIDOR BELOW ATTIC OPEN TO BELOW FIRE ALARM THIRD FLOOR PLAN (NO WORK ON THIS FLOOR) scale: 1/8" = V - 0" \ �IEnm Rm{ pi O KnSIC R�1 \ \ 15 1 W \yNl V SIPPLff TEACHER'S TEACHER'S TEACHER'S OFFICE OFFICE/ OFFICE OPEN CORRIDOR R. / "Cl RES REST TEACHER'S TEACHER'S TEACHER'S OFFICE OFFICE OFFICE DRESSING AREA STUDENT LOUNGE r •. I STORAGE �I .� � r- I � I FLOOR LEVEL STAGE ®a 1 CLOSET U VEST. Hj WOMEN ALL -0 LOBBY CLASSROOM ' STORAGE MEN ® ') (+g' OPEN CORRIDOR ` ON •v y,� / SCOPE OF WORK FIRE ALARM SECOND FLOOR PLAN scale: 1 /8" = V - 0" TFffflTW_ j. Axtroa 6 Hn ! CLASSROOM I / Z. i I I OPEN CORRI R CLASS�OOM / 0. r••straa CLASSROOM CLASSROOM CLASSROOM CLASSROOM �. WtlwNcnW' V. TOILET p i®®®®® e®I Cu / DRESS. DANCE CLASSROOM DANCE CLASSROOM I e BELL •1 OFFICE ( CLASSROOM OPEN CORRIDOR FACP POC SCOPE OF WORK U FIRE ALARM FIRST FLOOR PLAN scale: 1 /8" = 1' - 0" PIV AND B.F.P. VALVES (N.T.S.) BATTERY CALCULATION - FACP - FIRE LITE M59200 Device Type Qty Standby / Device (Amp) Alarm / Device (Amp) Total Standby Current (Amp) Total Alarm Current (Amp) Main Board 1 0,08000 0.16800 01080000 0,168000 LIDACT-F 1 0.04000 0.07500 0,040000 0.075000 5D350 Smoke Detector 3 0.00030 0.000900 BG- 12LX Pull Station 19 0.00020 0,003800 CRF-300 Control Relay 7 0.00027 0.001890 MMF-301 Mmitor Module 13 1 0,00038 0.004940 D 1 0,00000 0.000000 SD355 Smoke Detector 1 0,00030 0.000300 0 0100000 0.000000 ALL Addressable devices 1 0.20000 0.20000 NAC # 1 1 0,0000 0.000000 NAC # 2 1 0.0000 0.000000 NAC # 3 1 0.0000 0,000000 NAC # 4 1 1 0.0000 0,000000 Totals 0.131830 0,443000 A/H Required Standby Time (24 Hours) 3.163920 A/H Required Alarm Time (5 Minutes) 0.037212 Sub Total Standby / Alarm (Amp/ Mrs) 3,201132 Multiply by the deratmg Factor (I.2) 3.84 USE BATTERY SIZE 4.0 A/H BATTERY CALCULATION - FIRE LITE FCP5-24F58 - POWER SUPPLY # I Device Type Qty. Standby/ Device (Amp) Alarm / Device (Amp) Total Standby Current (Amp) Total Alarm Current (Amp) Main board 1 0.065 0.145 0,065000 0.145000 Power Supervision Relay 0 0.025 0.025 0.0000 0.000000 S 1 224MC (75) Strobe 6 0.160 0,960000 P 1224MC (75) Horn Strobe 25 0,217 5,425000 P 1224MC (I 1 O) Horn Strobe 2 0.266 0,532000 Totals 0.065000 7.062000 A/H required Standby Time (24 Hours) 1,560000 A/H required Alarm Time (5 Minutes) 0,593208 Sub Total Standby / Alarm (Amp / Hrs) 2,1532 Multiply by the Derating factor (1.2) 2 58 USE BATTERY SIZE 4.0 A/H r • • ••• ••• ••• • BATTERY CALCULATION - FIRE LITE FCPS-241`58 - POWER SUPPLY #2 Device Type oty. Standby / Device (Amp) Alarm / Device (Amp) Total Standby Current (Amp) Total Alarm Current (Amp) Main Board 1 0,065 0,145 0,065000 0.145000 Power Supervision Relay 0 0.025 0.025 010000 0.000000 S 1 224MC (75) Strobe 1 0.160 0160000 PI 224MC (75) Horn Strobe 16 0.217 3.472000 Totals 0.065000 3,777000 A/H required Standby Time (24 Hours) 1,560000 A/H required Alarm Time (5 Minutes) 0,317268 Sub Total Standby / Alarm (Amp/ hrs) 1,8773 Multiply by the Deratmg factor (1.2) 2.25 USE BATTERY SIZE 4.0 A/H BATTERY CALCULATION - FIRE LITE FCP5-24F58 - POWER SUPPLY #3 Device Type Qty. Standby/ Device (Amp) Alarm / Device (Amp) Total Standby Current (Amp) Total Alarm Current (Amp) Main Board 1 0.065 0.145 0.065000 0,145000 Power 5upervi5ion Relay 0 0.025 0,025 010000 0.000000 SR (15) Strobe 5 0.066 0.330000 SR (75) Strobe 7 0,158 11106000 PR/ P2RK (75) Horn Strobe 6 0.176 1.056000 Totals 0.065000 2.637000 A/H required Standby Time (24 Hours) 1,560000 A/H required Alarm Time (5 Minutes) 0.221508 Sub Total Standby / Alarm (Amp / Hrs) 1J815 Multiply by the Deratmg factor (1.2) 2,14 USE BATTERY SIZE 4.0 A/H PS- I - VOLTAGE DROP CALCULATION - FIRE LITE - FCP5-241`S8 Vd= 2 x D(Ft) x DC Re515t(Ohm/ft) x I(Amp) DeCircuit 5cr ptlon NAC I MaximumLoad Current 2.425 Volt(Voll 5) nge -7-6- 33 (AWG)e 14 DC(Ohsm/Ft� ce 0.00307 DI(tFat)ce 220 �oatalge 20.4 Voltage Drop 3.275690 IznVoltage 17. NAC 2 3.0 2,539 16 - 33 14 0.00307 240 20.4 3,741470 16,66 NAC 3 3.0 1,953 16 - 33 14 0.00307 270 20,4 3,237683 17.16 -20,40 NAC 4 3.0 0.000 16 - 33 14 0,00307 0 e.U.4 0,0000 0 TOTALS 8.0 6,917 P5-2 - VOLTAGE DROP CALCULATION - FIRE LITE - FCP5-24F58 Vd= 2 x D(Pt) x DC Re5i5t(Ohm/ft) x I(Amp) Circuit De5cr ption NAC I Maximum mpLoad 3.0 Cur(Amp) ad 1,736 Volt(VOlt5) 6 - 3 (AWG)e 14 DC(Ohsr /Ft) ce OA0307 D1 �Ft)ce 160 Voltage rtincj 2014 Voltage Drop 1. 05446 Voltage .69 NAC 2 3.0 1,896 16 - 33 14 0,00307 170 20,4 1979045 18,42 NAC 3 3.0 01000 16 - 33 14 0,00307 0 20,4 0.000000 20.40 NAC 4 3.0 0.000 16 - 33 14 0.00307 0 N.4 0,00 000 20,40 TOTALS 810 3,632 P5-3 - VOLTAGE DROP CALCULATION - FIRE LITE - FCPS-241`58 Vd= 2 x D(Ft) x DC Re515t(Ohm/ft) x I(Amp) Circuit De5cr ptlon NAC 1 Maxl(AmmpLoad 3.0 Current 0.624 Volt(Volt5)cje 1 - 33 (AAWG)e 1 DC(Ohsm/Ft� ce . 0307 DI(tFat)ce 130 StartVoltalng ge 4 Voltage Drop 0, 80 7 iricj Voltage 19.90 NAC 2 3.0 01400 16 - 33 14 0.00307 80 20.4 OS 6480 20.20 NAC 3 3,0 0A24 16 - 33 4 ,00307 130 20.4 0.498077 19.90 NAC 4 3.0 0.844 16 - 33 14 0,00307 160 20.4 0,829146 19,57 TOTALS 8,0 492 SCOPE OF WORK SCOPE OF WORK APPROVED MIAMI-DADE COUNTY FIRE DEPARTMENT % BLDG. PERMIT FIREALARM - / FIRE SUPPRESSION_ WATER MAIN DO. FIRE ALARM SYSTEM TO BE INSTALLED IN ACCORDANCE WITH NFPA 72: 70; 101 II = S SECURITY SYSTEMS 7963 N.W. 14th STREET DORAL, FLORIDA 33126 TEL : 305.477.9640 FAX: 305.477.1083 w .WSEFS.com LICENSE #: EC-0001652 NOTIFIFFe by Honeywell+ no FM APPROVED ENGINEERING: Carlos Rodriguez, P.E. LIC. #65687 8101 S.W. 104th STREET MIAMI, FLORIDA 33156 PHONE: (786) 390-8213 Z OA cri O O Wz�x Q N cci z U N 'o a Revisions: A A ZL drawing by: L.C. design by: WSE date: 01.05.2017 project k 17-0105 scale: as shown FIRE ALARM SYSTEM FA=2 sheet 2 of 4