17-483-06REVISION BY SO .g LOW PRESS. 1 REGULATOR _ T I 3/4" GAL V j GAS UP T I CLG l I I I 14' I 3/4" GALV GAS ALONG WALL TO WATER HEATER I I S.O.V. W/ DRIP LEG T LOW PRESS. S.O.V. REGULATOR Y' NORITZ TANKLESS LP WATER HEATER MODEL- NRC 1111 EF-.91 159 M5TU/HR SEE DETAIL ON THIS SHT WITH 3/4" CW DOWN TO EWH E 1/2" HW EXITING EWH FLUM51NG NOTES: SCOPE OF WORK- THE WORK SHALL INCLUDE ALL PLUMBING NECASSARY SHOWN ON THE DRAWINGS AND/OR NEEDED FOR A COMPLETE SYSTEM, INCLUDED BUT NOT NECASSARILY LIMITED TO: DOMESTIC COLD AND HOT WATER PIPING SYSTEM SANITARY DRAIN AND VENT SYSTEM PLUMBING FIXTURES AND TRIM AIR CONDITIONING CONDENSATE DRAINS, SEE MECH. SHEETS. PRESSURE AND TEMPERATURE RELEIF AS NEEDED FOR WATER HEATERS. PIPING INSULATION. SUPPORTS AND HANGERS. ALL PLUMBING WORK SHALL 5E PERFORMED IN ACCORDANCE WITH THE 2014 FLORIDA BUILDING CODE, LOCAL ORDINANCES. CONTRACTOR TO FIELD VERIFY THE LOCATION, ELEVATION FOR SLOPES AND SIZE ALL LINES, EXISTING OR NEW BEFORE BEGINNING INSTALLATIONS. G.C. TO COORDINATE EXISTING AND/OR NEW STRUCTURAL ELEMENTS WITH SANITARY AND WATER LINE LAYOUT FOR ANY OBSTRUCTIONS. NOTIFY ARCHITECT IF ANY PROBLEMS OCCUR ALL A50VE GROUND AND 5ELOW GROUND SANITARY LINES TO 5E SCHED 40 PVC. 5ELOW GROUND WATER SERVICE LINE TO 5E SCHED 40 PVC. ALL A50VE GROUND WATER DISTRIBUTION LINES TO 5E TYPE M COPPER OR CPVC, AND ANY BELOW GROUND WATER DISTRI5UTION LINES TO 5E CPVC AS PER F5C 2014 PLUM5 605.4 SUPPORT ALL 4"0 OR SMALLER PVC PIPING MAX 4' O.C. HORIZANTAL E MAX 10' O.C. VERTICAL. SUPPORT ALL 4"0 OR SMALLER COPPER LINES MAX 12' O.C. HORIZONTAL E 10' O.C. VERTICAL WITH APPROVED MATERIAL THAT WILL NOT PROMOTE GALVANIC ACTION. WASTE LINES 3",P OR LARGER TO HAVE MIN SLOPE OF 1/5"/FT, AND WASTE LINES 2"0 OR SMALLER TO HAVE MIN SLOPE OF 1/4"/FT. ALL PIPING TO 5E SEPARATED FROM THE STRUCTURE OR PARTITIONS IN A MANNER TO ELIMINATE VIBRATION. PROVIDE SLEEVES FOR ALL PIPING PASSING THROUGH SLA58 OR MASONRY WALLS. CAULK GAPS 5ETWWEN PIPING AND SLEEVES. WHERE EXPOSED PIPES PASS THROUGH SLA58 OR WALLS, PROVIDE ESCUTCHEON COVERS TO CONCEAL PENATRATIONS. VERIFY LOCATIONS OF ALL EXISTING SANITARY AND WATER LINES BEFORE STARTING WORK, NOTIFY ARCHITECT OF ANY DESCREPANCIES. REPAIR EXIST CONC SLAB AS PER ATTACHED DETAIL AS REQUIRED DUE TO NEW PIPING FIXTURE CONNE nON SCHEDULE (AS PER MIAMI DACE COUNTY CODE 6-51.5) WASTE d WATER FIXTURE WATER COLD HOT ITEM 501L Okq RATEE UNITS. WATER CLOSET 5" 1.1 61*F 4 1/2" TUB 2" 1.5 6PM 2 112.. 1/2 " WHIRLPOOL 2" 1.5 6PM 2 1/2 " 14211 LAVATORY I-1/4" 1.5 6PM I 1/2 " 1/2 " URINAL 2" 0.5 6PF 2 1/2 " 14211 SHOWER 2" 1.5 6PM 2 14211 1/2 " KIT SINK 2" 1.5 6PM 2 1/2 " 1/2 " WASH MACHINE 5" W.F. < & 4 1/2 " 14211 LAUNDRY SINK 2" 1.5 6PM 2 1/2 " 1/2 " HOSE 515E 1/2" DISH WASHER 6.5 6PC 1/2 " 142 11 PARTIAL WATER SCALE: 1/4" = 1'-0" 1 3/4" GALV GAS DN / / 1 3/4" GALV GAS 8' <� IN CLG- 11' IN I / r 1 3/4" GALV GAS RANGE e- - i GAS UP (110 M5TU/HR) REG. 1 I I S.O.V. I 12 3/4" GALV I GAS ALONG WALL ` S.O.V. W/ DRIP LEG 100 G. PROPANE �� LP GAS TANKLESS GAS TANK WATER HEATER SOY (lg9 M5TU/HR) LOW PRESS. REG EXIST 145 W/ J V5 E S.O.Y. EXIST 1" CW FROM EXIST W/M RTgFR 1ST SYSTEM TO WATER HEATER MAX LOAD- 15S MBTU/HR TOTAL RUN (LOW PRESS)-16' GAS TYPE- LP 2ND SYSTEM TO GAS RANGE MAX LOAD- 110 MBTU/HR TOTA RUN (LOW PRESS)- 33' LONGEST LOW PRESSURE RUN- 2' GAS TYPE- LP *4x16" LONG DOWELS EA SIDE * 24"o c. EMBEDDED 4" INTO EXISTING SLAB w/ 14ILT1 HIT HY-150 EPDXY SYSTEM NEW CONC. SLAB W/ 6x6 WIA/WIA W.W.F. F5C LP GAS TA5LES GALV PIPE- TA5LE 402.4 (26) TOTAL LOAD- 305 M5TU/HR LONGEST RUN- 33 FT l li li it l l i I li iLI-1 � �l l 11 lL--11f111 l 11 l &-I� VAPOR BARRIER EXIST CONIC SLAB REPAIR DETAIL SCALE: NTS G.O. UA-iEFft EXIST SAN LINE 0-,l &-^'v 1 t vrwt Sri ru EXITS HOUSE, IF NOT EXISTING. TO EXIST SEWER LAT 'AID PARTIAL SANITARY SCALE: 1/4" = 1'-0" NEW 2" VENT UP. CONNECT TO EXIST 2 ROOF CAP i NOTE: ALL DRAWINGS FOR THIS PROJECT ARE TO BE READ IN CONJUNCTION WITH EACH OTHER. THESE INCLUDE, BUT ARE NOT LIMITED TO: ARCHITECTURAL, SURVEYING, STRUCTURAL, CIVIL, MECHANICAL, ELECTRICAL, SPECIALTY DRAWINGS, & WRITTEN SPECIFICATIONS. CONTRACTOR TO VERIFY ALL EXISTING SITE CONDITIONS AND THOROUGHLY CHECK ELEVATIONS AND DIMENSIONS BEFORE COMMENCING WORK. REPORT TO THE ARCHITECT ENGINEER ANY DISCREPANCIES, ERRORS OR CONDITIONS THAT WILL ALTER CONSTRUCTION AS INTENDED BY THESE DRAWINGS. ARCHITECT IS NOT RESPONSIBLE FOR ANY WORK w AND/OR MATERIALS FURNISHED ON THE JOB. All graphic material appearing herein, unless indicated otherwise, are the property of the Architect as y instruments of service for use solely on this project, and may not be duplicated, used or disclosed without the written consent of Mark E. Reardon, R.A. The architect retains all common law, statutory and other reserved rights. A� , d Reardon 117, a4 0; � i -P •REGIST'E'¢�O Z J coLU o� 0 2 � W U W Z - Z 0 Q N W J LL W d H Z W Q Q J W a30 Ix J N= TWO 0� QZ0000 a 06 06 W to 0 MER UAIt' 4/4/17 AS NOTED i14:111111z ME P-1