17-483-05sees ses �. 1 I_ I REVISION BY FAN SCHEDULE FAN NO. ALL BATH EXHAUST FANS AREA SERVED EF-1 EF-2 LOCATION CEILING CEILING MOTOR TYPE CONDENSER CONDENSER FAN RPM 1200 1200 C F M 50 100 STATIC PRESS. 0.125 0.125 TYPE DRIVE DIRECT DIRECT H.P. MOTOR 60 WATTS 160 WATTS ELECT. CHARACT. 120 1 60 120/1/60 MANUFACTURER PANASONIC PANASONIC MODEL NO. FV-05VQ5 FV-10VQ5 DUCT DIA. 4" DIA 4" DIA EXIST CU EXIST BEDRM 2 FL ST MIN 26 GA. 1-1/2" WIDE FLAT MTL STRAP HANGERS SECURED TO STRUCTURE 6 MIN .145 DIA. POWER DRIVEN PINS, OR 3/16x1-3/4" T.CONS AT CONC., OR #8x1-1/2" WOOD SCREW AT WOOD(TYP) FIBERGLASS DUCT AS PER PLAN ji E�------------------------ wIN I2 CA WIRE HANGER (OR MIN 1 "-22 GA STRAP) W/ 22 GA CHANNEL SUPPORTS FOR DUCT 18" W & SMALLER, OR 18 GA CHANNEL SUPPORT FOR DUCT MORE THAN 18" W. DUCT SUPPORT HANGER DETAIL EXIST KITCHEN 8"41 26 G RANGE E HAUST TO EXIST ROOF ---, EXHAUST I 1 (NO GRA ITY APPLIAN E-5 METAL CONNECT REMOVE EXIST S/A DIFFUSER AND 84 FLEX DUCT FROM OLD DINING ROOM LOW VELOCITY AIR FLOW SUPPLY AIR DUCT (SEE PLAN VIEW) SEAL JOINT WITH DUCT SEALER AND TAPE. INSULATED FLEX DUCT (8'-0" MAX.) THERMOFIN OR EQUAL �--- SEAL JOINT WITH DUCT SEALER AND TAPE. LOUVERED ��— DIFFUSER FLEXIBLE DUCT CONN. DETAIL EXIST EXIST MASTER SEDRM LIVING RM REMOVE EXIST S/A DIFFUSERS FROM OLD CLOSETS AND INSTALL NEW DIFFUSER AS SHOWN 44 EXIST 1>; PANTRY �---------- 8x4 BEDRM 3 CONNECT NEW 44 FLEX CFM REMODELED I DUCT TO EXIST ANU I �LO CONNECT NEW 4"0 E>4 �� 1-t I� S/A PLENUM DUCT TO EXIST A I $/A PLENUM L - -- EXIS ° AHU CLO CONNECT NEW 4"0 FLEX REMODEL �� DUCT TO EXIST ANU 1 EXIST $/A 40 CFM S/A PLENUM DIFFf100 CFM) 5ATH ------------------------- '-------- ----- o—— — — — — — — � NEW EXIST POWDER > 1 EXIST �_2 LAUNDRY v. RM DINING PROVID 12"x12" MAKE UP AIR GRILLE IN WALL 4"0 26 G.A. FLEX EXHAUST DUCT TO SOFFIT CAP d B.D. DAMPER PROVIDE CORROSION RESIST SCREEN AT OPENING W/ MIN 1/4" 4 MAX 1/2" OPENINGS. TYPICAL ALL NEW BATHRM EXH. FANS THIS FL. SEE WALL CAP DETAIL EXIST GARAGE 110P-m wr-w� PARTIAL MECHANICAL PLAN SCALE: 1/4" = 1'-0" n.t.s. � y me N Q� 8 NOTE: ALL DRAWINGS FOR THIS PROJECT ARE TO BE READ IN CONJUNCTION WITH EACH OTHER. THESE INCLUDE, BUT ARE NOT LIMITED TO: ARCHITECTURAL, SURVEYING, STRUCTURAL, CIVIL, MECHANICAL, ELECTRICAL, SPECIALTY DRAWINGS, & WRITTEN SPECIFICATIONS. CONTRACTOR TO VERIFY ALL EXISTING SITE CONDITIONS AND THOROUGHLY CHECK ELEVATIONS AND DIMENSIONS BEFORE COMMENCING WORK. REPORT TO THE ARCHITECT ENGINEER ANY DISCREPANCIES, ERRORS OR CONDITIONS THAT WILL ALTER CONSTRUCTION AS INTENDED BY THESE DRAWINGS. ARCHITECT IS NOT RESPONSIBLE FOR ANY WORK AND/OR MATERIALS FURNISHED ON THE JOB. All graphic material appearing herein, unless indicated otherwise, are the property of the Architect as instruments of service for use solely on this project, and may not be duplicated, used or disclosed without the written consent of Mark E. Reardon, R.A. The architect retains all common aw, statutory and other reserved riahts. lW .. Dq ,`ki • d Reardon . , SEAL: �' 4, FGISTER� J IU) ° 0 0 W LU Z W 0— Z 3 W 0 co J J W � 0 W d W C C� N � L Z X � Q J W U) Q30J NI �w0o? aZ°� 0 00 10606LL InU) MER DATE: 4/4/17 Qf%A1 C. AS NOTED SHEET NO.: M-1