17-483-04
No EXIST PANEL "A" TYPE: SO. D. MAIN SUS: 200 A. NOTES: (53 C5 RATED FOR 15- C SERVICE: IPH-3W, NEUTRAL: 200 A. IOCOOLING NON-COINC, CONDUCTORS VOLTAGE: 120/240 MAINS: MLO 120 10KW HEAT= COOLING NON-COINC. ® 2212 5R ®3W/SF.= (003(0 MOUNTING: SURFACE .1KW FAN CKT + LOAD SERVED 0 OF POLES TRIP TOTAL VA VOLTS WIRE NOTE C1Ct + LOAD SERVED OF ES POLES TRIP V � TOT AL VOLTS WIRE NOTE I EXIST AHU-I 2 40 10;10 240 2% 2 EXIST CU-1 2 30 3012) 240 2*6 I 3 3 NEW REF 1 20 1500 120 *12 4 5 NEW DISHWASHER 1 20 1200 120 012 6 NEW OVEN 2 50 12000 12/0�g0 3% 1 EXIST WASHER 1 20 1500 120 I 012 8 g NEW MICROWAVE 1 20 1500 120 012 10 EXIST DRYER 2 30 5000 139-14" 3MO 11 NEW GARB. DISP. 1 20 1200 120 M2 12 13 NEW HOOD EXHAUST 1 20 1200 120 012 14 SPRINKLER PUMP 2 20 2300 240 1012 15 GEN LIGHTING 1 15 6636 120 014 ® 16 n GEN LIGHTING 1 15 120 *14 18 SM. APPL. I 20 1500 120 012 19 GEN LIGHTING 1 15 120 *14 20 SM, APPL. 1 20 1500 012 21 GEN LIGHTING 1 15 120 014 22 GEN LIGHTING 1 15 1 120 014 23 GEN LIGHTING 1 I5 120 +14 24 EXIST LIGHTING 1 15 120 *14 25 EXIST LIGHTING 1 15 120 014 26 EX15T LIGHTING 1 15 120 014 21 EXIST LIGHTING 1 15 120 014 28 EXIST LIGHTING 1 15 120 014 29 EXIST LIGHTING 1 15 120 014 30 EXIST LIGHTING 1 15 120 *14 31 EXIST LIGHTING 1 15 120 *14 32 EXIST LIGHTING 1 15 120 *14 33 EXIST LIGHTING 1 15 120 014 34 1 EXIST LIGHTING 1 15 120 *14 35 EXIST LIGHTING 1 15 120 *14 36 1 EX15T LIGHTING 1 15 120 014 31 EX15T LIGHTING 1 15 120 M4 38 EXIST LIGHTING 1 15 120 014 39 EXIST LIGHTING 1 1 15 1 120 +14 40 CONNECTED LOAD 41,136 DEMAND LOAD: SYMBOL LEGEND CEILING OUTLET. "2" = CIRCUIT NO., "a" SWITCH LEG. 02a SHADING INDICATES EMERGENCY LIGHTING 0--d WALL -MOUNTED FIXTURE QO RECESSED DOWNLIGHT- LED • RECESSED MINI DOWNLIGHT- LED 4,A SECURITY FLOODLIGHTS. MOUNTED UNDER ROOF OVERHANG SINGLE -POLE TOGGLE SWITCH $3 THREE-WAY TOGGLE SWITCH © LUTRON WALL DIMMER 1__ - UNDER CABINET FLUORESCENT LIGHTING ❑j SAFETY SWITCH: "3" - NO. OF POLES, "6 0" = SWITCH SIZE, "SO" _ 2 FUSE SIZE* "600" - VOLTAGE IF OTHER THAN 250 VOLT. O CEILING -MOUNTED JUNCTION SOX WALL -MOUNTED JUNCTION BOX (EH 125/250 VOLT OUTLET. TYPE AS INDICATED DUPLEX CONVENIENCE RECEPTACLEt NEMA CONFiG. *5-15R —® SINGLE RECEPTACLEt NEMA CONFIG. *5-20R a® DUPLEX RECEPTACLE MOUNTED HIGHER THAN STANDARD MTG. HT., VERIFY EXACT HEIGHT AT CONSTRUCTION UNLESS HEIGHT 15 NOTED. TELEPHONE/DATA OUTLET- CAT 5 CABLE HD TV RECEPTACLE- RG/6 GABLE, PHONE CABLE t AUDIO CABLES 0 MOTOR SIZE AS NOTED U1P INDICATES WEATHERPROOF NEMA 04 OR *3R ,4,F,F. INDICATES ABOVE FINISHED FLOOR C.F.I. INDICATES GROUND FAULT INTERRUPTOR INDICATES EXISTING FIXTURE TO REMAIN S SELF -CONTAINED -TYPE SMOKE DETECTOR ® SELF -CONTAINED -TYPE SMOKE E CARBON MONOXIDE DETECTOR DOORBELL CHIME Q DOORBELL PUSHBUTTON ® AUD 10 SPEAKER IN CLG, COORDINATE ALL AUD 10/VISUAL INSTALLATIONS WITH OWNER BEFORE COMMENCING WORK 23 52" FAN PER OWNER'S SPECIFICATIONS W/ LUTRON ADJUSTABLE SPEED SWITCH ALL SMOKE DETECTORS TO BE INTERCONNECTED. ALL LIGHTING AND GENERAL RECEPTACLES TO BE "AFCI" INDICATES ARC FAULT CIRCUIT INTERRUPT. ALL IDA AND 20 A RECEPTACLES TO BE LISTED TAMPER RESISTANT RECEPTACLES. '15% OF LIGHTING TO BE RATED ENERGY EFFICIENT AS PER 2014 F5C E 404. EXIST MAIN 1 OF 1: 2P-200A. MAIN C.B. IN NEMA 3R U.L.S.E. ENCL., RATED 22,000 A.I.C. EXIST 200A., 1P1-1,3W ' 120/24OV. METER/MAIN EXIST COM50 3 *2/0 414 2-1/2"C e EXIST FPL UNDER3ND 3"C EXIST 102 SERVICE GROUND CLAMPED I TO BUILDING FOUN. REINF. BARS, COLD WATER PIPING AND 5/6" x IO' GRD ROD INTERIOR 10,000 A.I.C. EXIST PNL. ELECTRICAL RISER DIAGRAM NT.S LOAS ANAL�,515. BASED ON 120/ 240W, 17, 3W A. PNL "A" (SERVICE DEMAND LOAD) LOADSi 41,136 VA HEATING LOAD ® 65%: 6500 VA NEXT 10000 vA * 100 6: 10000 VA REMAINDER 21,136 VA a 4M-: 11OS4 VA TOTAL: 21AI34 VA / 240 v = 115 A. A15 GFI/U1P GE E �A15 AID- 15 EXIST A15 BEDRM 2 SEE NOTE® A15 FOR RECEPT'S A15 E s vp� AID )AID 9 AID EX15T LE ® BEDRM 3 E A15 SEE NOTE® A15 FOR RECEPT'S GENERAL NOTES: (3 ALL WORK SHALL COMPLY WITH LOCAL LAWS, THE FLORIDA BUILDING CODE 2014, CURRENT NEC & WITH THE RULES AND REGULATIONS OF THE LOCAL UTILITY COMPANIES. (2) ELECTRICAIN TO VERIFY ALL EXISTING CONDITIONS PRIOR TO COMMENCING WORK. NOTIFY ARCHITECT OF ANY DISCREPANCIES BETWEEN THE PLANS AND FIELD CONDITIONS. 03 ALL WIRING SHALL BE UNIFORMLY COLOR —CODED THROUGHOUT THE ENTIRE PROJECT. COLORED INSULATION SHALL BE USED FOR SIZES #10 AND SMALLER, AND APPROVED COLOR TAPES SHALL BE USED FOR SIZES #8 AND LARGER. ® ALL POWER WIRING SHALL BE IN RACEWAY, AS FOLLOWS: A) UNDERGROUND OR IN GROUND FLOOR SLAB — PVC SCHEDULE 40 WITH GREEN BOND WIRE, OR ASPHALT —COATED RIGID GALVANIZED STEEL. B INTERIOR WORK — EMT, ENT, OR NON—METALLIC SHEATED CABLE. C EXPOSED OUTSIDE — RIGID GALVANIZED STEEL. D CONNECTIONS TO EQUIPMENT — FLEXIBLE CONDUIT, LIQUID —TIGHT IN 'SET LOCATIONS. (3) VERIFY ACTUAL METHOD AND LOCATION OF SERVICES TO ELECTRIC APPLIANCES AND MECHANICAL EQUIPMENT PRIOR TO ROUGHING —IN. © VERIFY BRANCH CIRCUIT REQUIREMENTS OF APPLIANCES AND MECHANICAL EQUIPMENT AGAINST NAMEPLATES OF ACTUAL EQUIPMENT BEING INSTALLED. 7Q WIRING DEVICE PLATES IN FINISHED AREAS SHALL BE OF PHENOLIC COMPOUND WITH POLISHED FINISH. WIRING DEVICES SHALL BE LEVITON "DECORA", OR EQUAL. FINISH SHALL BE WHITE OR AS SELECTED BY ARCHITECT. ® EXISTING ELECTRICAL WORK IN AREAS NOT AFFECTED BY THIS REMODELING SHALL REMAIN ENERGIZED FROM EXISTING BRANCH CIRCUITS. PROVIDE SMOKE DETECTORS ON AFCI CIRCUIT WHERE SHOWN IN EXIST ROOMS. �E �E �E A3 EXIST E E >< KITCHEN ® E SEE NOTE® AI9 A15 FOR iRECEPT'S O A19 A18 O Ai9 A19 O O A23 A23 O I Al 3 GF A19 EX15T ' s AID A23 B�4TH g 0�� A11 E � O A19 SEE NOTERWEI' I FOR R',ECEPT'S EXIST Aft I Al9 EXIST MA6TER BED All To ALL I LIVING RM UNDER I A423 gA23 A23 GAB Li I Ai9 Ai9 A19 A19 A19 RELOCATE TCONN O ExiS�t cKt AZ I ' IRE� All 4® \ A19 Ai9 I A17 All — — Al I O I I I I � P�NTAll E i R1' i L--------J EXISTIF GFIALIP o AHU T Ali EXIST ELEC SERV SEE NOTE EX15T L,4UNDR t EXIST G,4R GE SEE NOTE A26 CLO 6 — A20 1ti All E O All POWDER All I RM O O A21 A21 A2E A22 A21 A21 REMODELED CLO i� A22 ►W 21 EX15T PINING A22 IN GFI A26 (9 A22 v A21 R MODELED A22 B THRM 0�0�111111111110�U SCOPE OF WORK- P4eW LIGHTING THROUC44OUt AS SHOWN AND NEW RECEPTAI:LES IN REMODELED AREAS. ALL ELEC SERVICE EQUIPMENT AND BRANCH PANEL ARE EXISTNG TO REMAN PAF!TIAL ELECTRICAL PLAN SCALE: 1/4" = 1'-0" E E REVISION BY a0606LL InCo MER 4/4/17 .E: AS NOTED T NO. E-1