Loading...
17-483-02REVISION BY EXISTING TIE -BEAM EXISTING MASONRY ik T.O. SL A IRV EXISTING FOOTING NEW 8" CMU INFILL TO ENCLOSE EXIST WINDOW OPENINGS. PROVIDE 9 GA. TRUSS TYPE REINF ® 16" O.C. VERT, AND CMU WALL OPENING ENCLOSURE SCALE: 1/2" = 1'-0" EXISTING TIE -BEAM DRILL AND El #5 DOWEL. F 8" MIN EMBE AND 30" SPL (AT TIE -BM. FOOTING) NEW #5 TIE NEW OPENINC CONC FILLED SIDE EXISTING MASONRY WAI LINE OF COl` FLOOR SLAB EXISTING C FOOTING NEW WiNDOW OPENING IN EXIST CMU WALL SCALE: 1/2" = V-0" REINFORCED MASONRY NOTES I CODE REFERENCE- 2014 FLORIDA BUILDING CODE 1) MASONRY UNITS SHALL 5E 2 CELL HOLLOW UNITS CONF-ORMING TO AS.TM C-W WITH COMPRESSIVE STRENGTH OF F'c=IWV PSI ON THE NET CROSS SECTIONAL AREA AND SHALL 5E LAID IN RUNNING BOND. ASCE 1-10 WIND CODE 2) MORTAR SHALL COMPLY WITH A.S.T.M. 210. MORTAR TYPE S. F'm=1500 PSI EXPOSURE- "C„ WIND VELOCITY- 1-15 MPH 3) ANY GROUT USED IN THE WORK SHALL CONFORRM TO A.S.T.M. C416 WITH A SLUMP MIX OF 8" TO II", PROVIDE CLEANOUT AND INSPECTION HOLES AT FILLED CELLS AT BOTTOM COURSE. RISK CATAGORY 11 4) POUR GROUT IN LIFTS NOT TO EXCEED 4'-011. Kd = 0.55 5) GROUT USED IN THE WORK SHALL OBTAIN A MINIMUM COMPRSSIVE STRENGTH OF 3000 PSI IN 28 SCOPE OF WORK- PROVIDE NEW WINDOWS AND DOORS DAYS. GROUT SHALL COMPLY WITH AS.TM. C416 AS PER SCHEDULE IN EXISTING AND NEW OPENINGS. REINFORCED CONCRETE NOTES WINDOW SUPPLIER AND INSTALLER TO VERIFY ALL 1) CONCRETE SHALL C 1FOIRM WITH ACI-318 IT SHALL REACH A MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI • 26 DAYS FOR FOOTINGS, SLA56 t 3000 PSi BEAMS t COLUMNS. EXISTING ROUGH WINDOW OPENINGS 2) MAXIMUM PERMISSIBLE SLUMP IS 54" IN STRUCTURAL CONCRETE WITH THE EXCEPTION 5ENG SAND CEMENT GROUT 3) AGGREGATES SHALL 5E CLEAN AND GRADED MAX" SIZES 3/4" CONCRETE ASTM C-33 SHALL CONFORM TO ASTM C-S4 4) NO ADMIXTURES PERMITTED WITHOUT WRITTEN APPROVAL OF ENGINEER 8"x8" GONG FILLED CMU, CELL WITH 1"5 REINF BAR 5) CONCRETE TESTING IS REQUIRED AS FOLLOWS: I SET OF 5 CYLINDERS FOR EVERY 50 CU. YOS. OF CONCRETE AS PER DETAILS AS PER ASTM C-S4 6) CLEAR COVER FOR REWCI;r-NG EARS SHALL BE: FOOTINGS 3" BEAMS/COLUMNS/ELEVATED SLABS—1-i/2" FORMED FACES IN CONTACT W/ EARTH_ _2" UNFORMED FACES _ 3" REINFORCING STEEL NOTES 1) REINFORCING STEEL fy = 60OW FAI. fa = 24)WO P.S.I. Es - 2SOW000 P.S.I. Em - 1,350OW P.S.I. N - Es/Em = 21.48 2) REINFORCING STEEL SHALL CONFORM TO A',. -TM A-615 GRADE 60. REINFORCNG STEEL SHALL 5E DETAILED AND FABRICATED ACCORDING TO THE " MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES". HOOK ALL DISCONTINUOUS TOP IENFORCNG. EPDXY NOTES 1) EPDXY USED IN THE WORK SHALL BE HILTI HIT HY 150. SOIL STATEMENT AS PER VISUAL INSPECTION SOIL CONDITIONS AT THIS SITE ARE SAND +f ROCK WITH A MIN BEARING CAPACITY OF 2000 PSF SHOULD OTHER CONDITIONS OR MATERIALS 5E ENCOUNTERED, THE ARCHITECT SHALL 5E NOTIFIED. PRIOR TO PROCEEDING WITH THE WORK THE ARCHITECT OR ENGINEER SHALL SUPPLY A LETTER ATTESTING THAT THE SITE HAS BEEN OBSERVED AND THE FOUNDATION CONDITIONS ARE SIMILAR TO THOSE UPON WHICH THE DESIGN IS BASED ON. SEE F.B.G. 2014 MIN 5/6" GYP 5D__- W/ 1-1/4" SCREWS 6 6" O.0 AT EDGES 0 12" O.G. FIELD PROVID E 2 "x6" BLOCKING i 20 GA MTL STUDS m 16" _ O.C. ATALL WALL HUNG — FIXTURE / ITEMS CONT 25 GA TOP RUNNER SECURED WITH 1-1/4" SCREWS m 24"O.C. TO FURRING. 25 GA MTL STUDS Q 24" O.C. MAX CONT 25 GA 50TTOM RUNNER SECURED WITH POWDER DRIVEN PINS 9 24"O.C. NEW INTERIOR PARTITION DETAIL EXIST CU KEYNOTES Repair existing ceiling due to scope of work w/ new 1/2" drywall on 10 1"x3" metal or wood furring at 16" on center. Tgpica I UON repair existing exterior wall finishes due to this scope of work w/ O5/5" drywall on 3/4" P.T. furring strips at 24" on center with R-4.1 foil insulation. OFor new interior partitions as shown on plan provide 5/6" gypsum 3 drywall each side on 3-5/8" 25 ga. metal studs at 24" O.C. max ONew built in cabinets as per owner O At showers and tubs, provide non absorbant, water resistant the up to min -12" a.f.f. OAll glass at showers and tuba to be CAT I or II rated as per 6 door and window schedules OExist 22"x 30" attic access panel OAll cabinets selected by owner and g c. O Provide new Tile floor, plaint and moldingd throughout. Owner to select all finishes. Window or door to have CAT I or CAT II glazing as specified at window and door schedules CODE REFERENCE- 2014 FLORIDA BUILDING CODE INTERIOR ALTERATIONS WITHIN THIS SCOPE OF WORK ARE CLASSIFIED AS "LEVEL 2" AS PER 2014 F5C EXIST 5LDGS ALL CEILING AND WALL FINISHES TO HAVE FLAME SPREAD CLASSIFICATION NOT GREATER THAN 200, AND AS PER F5C 2014 R302.9.1 ANY NEW INSULATION MATERIALS TO HAVE FLAME SPREAD INDEX OF NO MORE THEN 25, AND A SMOKE- DEVELOPED INDEX OF NO MORE THEN 450, AT ALL WALL HUNG ITEMS PROVIDE 20 GA STUDS 61 16" O.G. W/ 2" X 6" WOOD BLOCKING. SEE TYPICAL INTERIOR PARTITION DETAIL ON THIS SHEET SCOPE OF WORK- INSTALL NEW FINISH FLOORING THROUGHOUT. REMODEL MASTER BATHROOM AND KITCHEN AS SHOWN, PROVIDE NEW CABINETS THROUGHOUT. BASED 50ARDS AND CASING THROUGHOUT LEGEND: EXIST. 8" CMU WALL TO REMAIN 0 EXISTING INTERIOR PARTITION TO REMAIN. NEW INTERIOR PARTITION WITH 25 GA 3-5/S" METAL STUDS a 24" O.C. W/ 5/6" GYP 5D EA SIDE. PROVIDE MIN 3-1/2" SOUND ATTENUATING INSULATION AT ALL PLUM151NG WALLS. NOTES: DIMENSIONS INCLUDING CMU WALLS ARE TAKEN FROM THE APPLICABLE FACE OF THE CMU WALL. ALL PLUMBING AND ELECTRICAL FIXTURES TO 5E SELECTED 5Y OWNER 4 G.C. ALL MILLWORK TO 5E SELECTED 5Y OWNER # G.C. A55REVIATIONS(APPLICA5LE TO ALL SHEETS) O.G. ON CENTER AFF, A50VE FINISHED FLOOR V.IF. VERIFY IN FIELD AF:G. A50VE FINISHED GRADE U.ON, UNLESS OTHERWISE NOTED TYP TYPICAL CONT. CONTINUOUS E EXISTING TO REMAIN FLOOR PLAN SCALE: 1/4" = 1'-0" O ,OUTH MIAM NG DEPT.. RAL 710 T1 f t 15790 SW 88TH AVE MIAMI, FL 33157 AR 0017521 NOTE: ALL DRAWINGS FOR THIS PROJECT ARE TO BE READ IN CONJUNCTION WITH EACH OTHER. THESE INCLUDE, BUT ARE NOT LIMITED TO: ARCHITECTURAL, SURVEYING, STRUCTURAL, CIVIL, MECHANICAL, ELECTRICAL, SPECIALTY DRAWINGS, & WRITTEN SPECIFICATIONS. CONTRACTOR TO VERIFY ALL EXISTING SITE CONDITIONS AND THOROUGHLY CHECK ELEVATIONS AND DIMENSIONS BEFORE COMMENCING WORK. REPORT TO THE ARCHITECT ENGINEER ANY DISCREPANCIES, ERRORS OR CONDITIONS THAT WILL ALTER CONSTRUCTION AS INTENDED BY THESE DRAWINGS. ARCHITECT IS NOT RESPONSIBLE FOR ANY WORK AND/OR MATERIALS FURNISHED ON THE JOB. All graphic material appearing herein, unless indicated otherwise, are the property of the Architect as instruments of service for use solely on this project, and may not be duplicated, used or disclosed without the written consent of Mark E. Reardon, RA, Th architect retains all common law, s t�atory and other reserved rights. ,ORI DA ,�� • • a`d Reardo)Ai SEAL: Q' �GISTEa Z_ J W co 03 0 0 w 2 Z U W - Z 3 W O J J U. o� 0 w a w X (9 L 5� Z X Q Q J W Q30 J N= Pw0o� QZaX000 o. 06 06 w LID co MER DATE: 4/4/17 SCALE: AS NOTED SHEET NO.: A-1 SCALE: NTS