10-151-016FLUM51NG NOTES:
SCOPE OF WORK- THE WORK SHALL INCLUDE ALL PLUMBING NECASSARY
SHOWN ON THE DRAWINGS AND/OR NEEDED FOR A COMPLETE SYSTEM,
INCLUDED BUT NOT NECASSARILY LIMITED TO:
DOMESTIC COLD AND HOT WATER PIPING SYSTEM
SANITARY DRAIN AND VENT SYSTEM
PLUMBING FIXTURES AND TRIM
AIR CONDITIONING CONDENSATE DRAINS, SEE MECH. SHEETS.
PRESSURE AND TEMPERATURE RELEIF AS NEEDED FOR WATER HEATERS.
PIPING INSULATION.
SUPPORTS AND HANGERS.
ALL PLUMBING WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE
LATEST EDITION OF THE FLORIDA BUILDING CODE, LOCAL ORDINANCES.
CONTRACTOR TO FIELD VERIFY THE LOCATION, ELEVATION FOR SLOPES
AND SIZE ALL LINES, EXISTING OR NEW BEFORE BEGINNING INSTALLATIONS.
UNDERGROUND METAL PIPING SHALL BE COATED WITH BITUMINOUS COMPOUND
BEFORE COVERING.
WASTE LINES 3"0 OR LARGER TO HAVE MIN SLOPE OF 1/8"/FT, AND WASTE
LINES 2"0 OR SMALLER TO HAVE MIN SLOPE OF 1/4"/FT.
ALL PIPING TO BE SEPARATED FROM THE STRUCTURE OR PARTITIONS IN A
MANNER TO ELIMINATE VIBRATION.
PROVIDE SLEEVES FOR ALL PIPING PASSING THROUGH SLABS OR MASONRY
WALLS. CAULK GAPS BETWWEN PIPING AND SLEEVES.
WHERE EXPOSED PIPES PASS THROUGH SLABS OR WALLS, PROVIDE
ESCUTCHEON COVERS TO CONCEAL PENATRATIONS.
FDa URE CO►NNECrM 9CEM DULE
ITEM
WASTE d
SOIL
FIXTURE
UNITS.
KATER
COLD
HOT
WATER CLOSET
55
4
1/2'
TUB
2"
2
1/2 "
1/2 '
WHIRLPOOL
2"
2
1/2 "
1/2 "
LAVATORY
1-1/4"
1
1/2 "
1/2 "
HOSE 5155
1/2,
SHOWER
2"
2
1/2 "
1/2 "
KIT SINK
2"
2
1/2 "
1/2 "
WASHER
3"
4
1/2 "
1/2 "
LAUNDRY SINK
2"
2
1/2 "
1/2 "
PLUMBINS NOTES:
I. WG = 15 SALLON PER FLUSH
2. ALL SANITARY LINES SHALL BE SLOPED AS FOLLOWS-
- 2' OR SMALLER SHALL BE SLOPED AT 1/4' PER FT.
- 3" OR LARSER SHALL BE SLOPED AT 1/8' PER FT.
S. PROVIDE ANTI SCALD VALVES AT ALL 5140101ERS.
VB
WATER PLAN
SCALE: 1/4" = 1'-0"
t
+: AIL ii �� ��`i �I�j�J
SCALE: 1/4" = l'-O"
W
-; ;
IN