10-151-014GENERAL NOTES: Q ALL WORK SHALL COMPLY WITH LOCAL LAWS, THE FLORIDA BUILDING CODE Q VERIFY ACTUAL METHOD AND LOCATION OF SERVICES TO ELECTRIC 2007, AND WITH THE RULES AND REGULATIONS OF THE LOCAL UTILITY APPLIANCES AND MECHANICAL EQUIPMENT PRIOR TO ROUGHING -IN. COMPANIES. (2 ELECTRICAIN TO VERIFY ALL EXISTING CONDITIONS PRIOR TO COMMENCING Q VERIFY BRANCH CIRCUIT REQUIREMENTS OF APPLIANCES AND MECHANICAL WORK. NOTIFY ARCHITECT OF ANY DISCREPANCIES BETWEEN THE PLANS EQUIPMENT AGAINST NAMEPLATES OF ACTUAL EQUIPMENT BEING INSTALLED. AND FIELD CONDITIONS. (3 ALL WIRING SHALL BE UNIFORMLY COLOR -CODED THROUGHOUT THE ENTIRE 7Q WIRING DEVICE PLATES IN FINISHED AREAS SHALL BE OF PHENOLIC PROJECT. COLORED INSULATION SHALL BE USED FOR SIZES #10 AND COMPOUND WITH POLISHED FINISH. WIRING DEVICES SHALL BE LEVITON SMALLER, AND APPROVED COLOR TAPES SHALL BE USED FOR SIZES #8 AND "DECORA', OR EQUAL. FINISH SHALL BE WHITE OR AS SELECTED BY LARGER. ARCHITECT. (4 ALL POWER WIRING SHALL BE IN RACEWAY, AS FOLLOWS: A) UNDERGROUND OR IN GROUND FLOOR SLAB - PVC SCHEDULE 40 WITH ® EXISTING ELECTRICAL WORK IN AREAS NOT AFFECTED BY THIS REMODELING GREEN BOND WIRE, OR ASPHALT -COATED RIGID GALVANIZED STEEL. SHALL REMAIN ENERGIZED FROM EXISTING BRANCH CIRCUITS. PROVIDE B INTERIOR WORK - EMT, ENT, OR NON-METAWC SHEATED CABLE. SMOKE DETECTORS ON AFCI CIRCUIT WHERE SHOWN IN EXIST ROOMS. C EXPOSED OUTSIDE - RIGID GALVANIZED STEEL. D CONNECTIONS TO EQUIPMENT - FLEXIBLE CONDUIT, LIQUID -TIGHT IN WET LOCATIONS. SYMBOL LEGEND CEILING OUTLET. "2" ■ CIRCUIT NO., "a" - SWITCH LEG. 02a SHADINGS INDICATES EMERGENCY LIGHTING ()--i WALL -MOUNTED FIXTURE @ RECESSED DOWNLIGHT- INCANDESCENT 4t4l SECURITY FLOODLIGHTS. MOUNTED UNDER ROOF OVERHANG SINGLE -POLE TOGGLE SWITCH $3 THREE-WAY TOGGLE SWITCH 02 WALL DIMMER I—o—I UNDER CABINET FLUORESCENT LIGHTING ❑J SAFETY SWITCH: "3" - NO. OF POLES, "60" - SWITCH SIZE,'"5v" 2 + FUSE SIZEt "600" - VOLTAGE IF OTHEIWTHAN 250 VOLT. O CEILING -MOUNTED JUNCTION BOX WALL -MOUNTED JUNCTION SOX (� 125/250 VOLT OUTLET. TYPE AS INDICATED DUPLEX CONVENIENCE RECEPTACLEt NEMA CONFIG. 09-ISR SINGLE RECEPTACLEt NEMA CONFIG. 05-20R DUPLEX RECEPTACLE MOUNTED HIGHER THAN STANDARD MTG. HT., VERIFY EXACT HEIGHT AT CONSTRUCTION UNLESS HEIGHT IS NOTED. TELEPHONE OUTLET- CAT 5 CABLE TECH PORT RECEPTACLE- 2 CAT 5 CABLES t R3/6 GABLE AND AUDIO CA13LING. COORDINATE HOME RUNS W/ OWNER MOTOR. SIZE AS NOTED UJP INDICATES WEATHERPROOF NEMA 04 OR 03R ,41=.1=. INDICATES ABOVE FINISHED FLOOR CaP.I. INDICATES GROUND FAULT INTERRUPTOR VP INDICATES VAPOR PROOF FIXTURE ® SELF -CONTAINED -TYPE SMOKE DETECTOR @H DOORBELL CHIME Q DOORBELL PUSHBUTTON 23 52" FAN PER OWNER'S SPECIFICATIONS NOTE: ALL SMOKE DETECTORS TO BE INTERCONNECTED. ALL NEW 15A AND 20A RECEPTACLES ARE TO BE TAMPER PROOF. ALL NEW GENERAL LIGHTING TO BE "AFCI", INDICATES ARC FAULT CIRCUIT INTERRUPT. REMOVED EXIST IWA,, 12 SPACE PNL B AND INSTALL NEW PANEL IN SAME LOCATION REPLACED PNL 'B' EXIST LAUNDRY i T Fmys ER MII EXIST BEDRM 1 SEE NOTE (8)-� EXIST EXIST —j_j BEDRM I BATNRM SEE NOTE Q NOTE 0 0 0 SE IRV ST 4 LEG lu o EXIST PNL A 51 5 AFCII AFcI 00 00 AFCI Bli 1523 EXIST BEDRM 1 SEE NOTE a -� 4 PR1OME SMOKE DE I CTOF AT ALL BEDROOMS AND ADJACENT MALLS. CONNECT TO AFCI CIRCUIT(TYP) X) © ®525 EXIST 525 I AFGI BEDRM I ANC— z '" SEE NOTE © -� Bn AFCI AFCI B19E STUDY AFct 519 ®AlFCI AFCI B1% 1519 E Al AFCI BI1 131'3I EXIST SEE AFGI AFM `. O 525 O ( O 44 E].I ®AMI ,451 4 I AfCIcc�flrt`• SgC. ��`3.�� •' I B29 52S8 W a o 3 521 521 AFGI AI=G1 1 A B25 B25FC[ 1325 ' 525 �25 -acaSs N I k �. 5 AFGI AFGI NEW ® ® AI FG s25 AFGI AFCI AFCI BATHRM AFCI B2S AFGI fu 15Z7 AFGt AFGI �) 1521 AFGt AFCI 1325 AFCI 1325 CIS I AFCI AFCI O B21 525 B25 0 B I NEW 13 I B t NEW 5221 BEDRM 3 vP BEDRM 2 v 1521 - J a 1 o 8 GRAUP 2 NEW CU 2 III 521 FWOVIDE J-90X IN NEW NEMA 3R' A2,4 SOFFIT FOR FLMJM SEC, LIGFlTS. RN EMPI T CONDUIT TO FONT IN AGCE861115LE ATTIC FOR FUTURE WIRING. ELECTRICAL PLAN SCALE: 1/4" = 1'-0"