10-151-013AIR DEFLECTOR EXTRACTOR I�:i11�1:�Z�IIr Do AIR FLOW ( I 1 AIR FLOW 'SPACER REQUIRED ON INSULATED DUCTS SET SCREW CLINCH EDGES GALV. STEEL ROD BRANCH DUCT .3 Q 1 U- Q TYPICAL DETAIL OF A 90"" DUCT TAP WITH AIR DEFLECTOR n.t.s. D W/S= NO. OF SPACES R= 1 1/4 8 L= 3/4 8 BLADES IN TRANSITION ELBOWS SHALL BE DETERMINED ACCORDING TO SMALLEST WIDTH OF ELBOW. SINCsLE VANE SCH. R IS IGA SMALL 51 138 24 LARGE 114 183 22 BOLT, SCREW OR WELD TO DUCT SCREW EVERT` 81XTH VANE L RECTANGULAR DUCT ELBOW DETAIL n.t.s. FLOOR/ CEILING STRUCTURE MIN .145 DIA POWER DRIVEN PINS, OR 3/160-314" T.CONS AT CONC., OR #8x1-1/2 WOOD SCREW AT WOOD(TYP) FLEX DUCT /EQ: FIBERGLASS DUCT AS PER PLAN MIN 26 GA 1-1/2" WIDE________ FLAT MTL STRAP HANGERS Lu SECURED TO STRUCTURE MIN 12 GA WIRE HANGER (OR MIN 1"-22 GA STRAP) WJ' 22 GA CHANNEL SUPPORTS FOR DUCT 18 W do SMALLER, OR 18 GA CHANNEL SUPPORT FOR DUCT MORE THAN 18" W. DUCT SUPPORT HANGER DETAIL GALV MTL W.P. ROOF CAP. GALV MTL SCREEN CLOSURE OVER ROOF CAP OPENING. OMIT SCREEN FOR DRYER VENT CAPS SECURE ROOF CAP --- AS PER MANUF. SPEC'S DAMPER FLASHING BY ROOFING CONTRACTOR 0 f/ 3 GFM CLOSURE \ NOTE: SHEET METAL CONNECTIONS MUST BE MADE USING GLASS FABRIC AND MASTIC(GFM) #10 x 1-1/4. SHEET MTL �� \ \ FLANGE SCREWS 0 12 O.C. MAX MIN 2 PER SIDE FIBROUS GLASS DUCT 22 GAUGE SHEET METAL, 1"x1"x1" CHANNEL FASTENED TO METAL FLANGE SHEET METAL & EQUIP CONN. HVAC SYMBOLS GENERAL INSULATED SUPPLY DUCT AS PER PLAN — _ — _ _ — — INSULATED RETURN DUCT AS PER PLAN 44 DIRECTION OF AIR FLOW 'ViVVVVlr INSULATED FLEXIBLE DUCT AS PER PLAN Rl SUPPLY AIR DIFFUSER FZ RETURN AIR DIFFUSER " IL�II EXHAUST FAN AA PER PLAN -F9J MANUAL DAMPER ROOF TRUSS I DUCT DIA. AS PER PLAN ROUTED UP THRU CEILING SPACE NOTE: ROOF CAP MANUFACTURER TO BE "NUTONE" OR APPROVED EQUAL. ROOF CAP DETAIL 26 GA 4" DIA EXHAUST DUCT A/C EQUIPMENT SCHEDULE UNIT DESIGNATION NEW AHU-1 CU-1 AREA SERVED SEE PLAN TOTAL COOLING CAPACITY, MBH 47.5 SENSIBLE COOLING CAPACITY, MBH 35.6 AIR SUPPLY (CFM) 1600 Q OUTSIDE AIR, CFM MINIMUM N/A = No. OF MOTORS — HP NON — OVERLOAD 1— 1 4 ELECTRIC HEATER KW STAGES 10-1 Q ELECTRICAL SERVICE AVAILABLE 240-1-60 F.L. AMPS 2.0 of No. OF MOTORS — HP 1 — 1 /8 w z F.L. AMPS 19.2 uJ 0 MINIMUM CIRCUIT AMP / MAXIMUM FUSE 45/45 o SEER 16 REFRIGERANT LINES SUCTION IN — LIQUID IN 3/4" — 5 16" DESIGN MANUFACTURER RHEEM AIR HANDLER MODEL NO. RBHM-25J 11 SMS CONDENSING UNIT MODEL NO. RARL-048JEZ NOTES Q ACCESSORIES 10 PROVIDE FACTORY FURNISHED ELECTRIC HEATER WITH SINGLE POINT CONNECTION. NOTE: UNIT TO BE INSTALLED ABOVE FLOOD ELEVATION BOLT CONDENSING UNIT TO SUPPORTS TO WITHSTAND 146 1" iPH HURRICANE FORGE WINDS / [><715 FAN SCHEDULE FAN NO. ALL BATH EXHAUST FANS AREA SERVED EF-1 - LOCATION CEILING MOTOR TYPE CONDENSER FAN RPM 1200 C F M 110 STATIC PRESS. 0.125 TYPE DRIVE DIRECT H.P. MOTOR 60 WATTS ELECT. CHARACT, 120 1 60 MANUFACTURER PANASONIC MODEL NO. FV-11VQ3 DUCT DIA. 4" DIA STEEL CABLES. ATTACHED TO MIN 1/24 ST. ASTL. A.B. W/ CLOSED EYE BOLT. CABLE TO BE INSTALLED TIGHT AND LOOPED THRU EYE BOLT AND CRIMPED AT BOTH ENDS. \ LIQUID t SUCTION LINE • • • • • / W/ INSULATION MIN 3/32" TH. 2"x2"xl" WIDE CLIPS SEAL W/ U.L. LABEL AT EA CORNER SECURE W/ C2J012 TEK SILICONE SEALANT " SCREWS AT UNIT t (2)1/4 xl-3/4 TAPGON TO CONC SLAB. 4" TH CONC BASE 6" MIN. 6 X 6 - JOAO UUF SCH. 40 PVC CONDUIT W/ SOLVENT WELDED JOINTS RUN UNDER SLAB. USE 4" OR Co" DIA. AS RECL COND. UNIT FASTENING DETAIL/ REFRIGERANT PIPING N.T.S. 26 GA MTL EXHAUST WEATHER CAP WITH BACK DRAFT DAMPER SECURED TO WALL WITH TAPCON ANCHORS EXHAUST WEATHER CAP LOW VELOCITY AIR FLOW SUPPLY AIR DUCT (SEE PLAN VIEW) SEAL JOINT WITH DUCT SEALER AND TAPE. `— INSULATED FLEX DUCT (8'-0" MAX.) THERMOFIN OR EQUAL SEAL JOINT WITH DUCT SEALER AND TAPE. LOUVERED �— DIFFUSER FLEXIBLE DUCT CONN. DETAIL n.t.s. GENERAL NOTES. 1.— THIS JOB REQUIRES A VERY THOROUGH COORDINATION BETWEEN ALL TRADES AND THE CONTRACTOR SHALL COORDINATE THE INSTALLATIONS OF THE DIFFERENT TRADES AND NOTIFY THE ARCHITECT IF ANY CONFLICTS OCCUR BEFORE INSTALLATIONS BEGIN. 2.— THE CONTRACTOR SHALL NOT FABRICATE ANY DUCTWORK PRIOR TO VERIFICATION OF ROUTING, SIZES AND AVAILABLE SPACE. 3.— CONTRACTOR SHALL FURNISH WRITTEN GUARANTEE THAT ALL WORK SHALL BE FREE FROM DEFECTS OF MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM DATE OF FINAL ACCEPTANCE. 4.— ALL WORK SHALL BE IN ACCORDANCE WITH THE 2004 FLORIDA BUILDING CODE AND ALL LOCAL CODES HAVING JURISDICTION; NFPA 90 A & B, ASHRAE GUIDE AND SMACNAS DUCT CONSTRUCTION STANDARDS. 5.— ALL SUPPLY & RETURN FIBROUS GLASS DUCTWORK TO BE CONSTRUCTED IN ACCORDANCE WITH SMACNA'S STANDARDS FOR LOW PRESSURE DUCTS. ALL JOINTS AND SEAMS TO BE SEALED WITH 4" TAPE (PERMACELL #691AF) 6.— ALL DUCTS TO HAVE MIN R-6 INSULATION VALUE. 7.— ALL FLEXIBLE DUCT RUNOUTS SHALL BE FLEXIBLE INSULATED DUCTWORK REINFORCED WITH A WIRE HELIX, PERMANENTLY BONDED WITHIN FABRIC, INSULATED, AND WITH A VAPOR BARRIER OF ALUMINUM METALIZED POLYESTER FILM LAMINATED TO GLASS MESH. WIREMOLD COMPANY OR APPROVED EQUAL. 8.— AIR DISTRIBUTION DEVICES ALL ALUMINUM CONSTRUCTION WITH OPPOSED BLADE DAMPERS AND EQUALIZING GRID. BARBER COLMAN, TITUS, CARNES, TUTTLE AND BAYLEY. 9.— N/A 10.— EXHAUST FANS — CAPACITIES AS CALLED FOR ON SCHEDULE. ALUMINUM CONSTRUC— TION, DIRECT DRIVE, BACK DRAFT DAMPER. ALUMINUM BIRD SCREEN, SAFETY SWITCH. ALL REFRIGERATION PIPING TO BE COPPER TYPE "K" HARD DRAWN WITH SWEAT AND WROUGHT COPPER FITTINGS. 12.— SUCTION REFRIGERATION LINES SHALL BE INSULATED WITH 3/4" ARMAFLEX. 13•— PROVIDE ALL NECESSARY CONTROLS FOR THE OPERATION OF THE A/C SYSTEM. 14.— VOLTAGES SHOULD BE VERIFIED PRIOR TO ANY INSTALLATION. 15.— TEST & BALANCE TO BE PERFORMED BY AN INDEPENDENT TEST AND BALANCE AGENCY. ADJUST DAMPERS AND FANS TO OBTAIN AIR QUANTITIES WITHIN 5% OF THOSE INDICATED ON THESE DRAWINGS. OBTAIN FULL LOAD AMPS READINGS FOR ALL MOTORS AT BALANCED CONDITIONS. RECORD OUTDOOR AND INDOOR DRY AND WET BULB TEMPERATURES AT BALANCED. SUBMIT ALL TEST AND BALANCE REPORTS TO OWNER FOR APPROVAL. HVAC DESIGN REQUIRES: YES NO DUCT SMOKE DETECTOR FIRE DAMPER(S) SMOKE DAMPERS �/ FIRE RATED ENCLOSURE V FIRE RATED ROOF/FLOOR CEILING ASSEMBLY , f FIRE STOPPING SMOKE CONTROL PERFORATED VENT CAP C.O. PLUG SLOPE 1 /8"/FT. i DRAIN OUTLET \I STRUCTURE MIN 26 GA FLAT MTL STRAP HANGERS SECURED TO STRUCTURE REFRIGERANT LIQUID UNE. CONN. TO INSULATION W/ PLASTIC STRAP. REFRIGERANT SUCTION LINE CONTINUOUS INSULATION o REFRIGERANT LIQUID LINE. FLOOR/ CEIUNG _--CONN. TO INSULATION W/ STRUCTURE ��_____ PLASTIC STRAP' MIN 26 GA FLAT CL REFRIGERANT SUCTION LINE MTL STRAP HANGERS CONTINUOUS INSULATION SECURED TO STRUCTURE SADDLE REFRIGERANT PIPING HANGER INSTALL SECONDARY GALV MTL DRAIN PAN MIN 1-1 /2"H W/ FLOAT SWITCH AT THE PAN OUTLET TO AUTOMATICALLY SHUT DOWN EQUIPMENT. CONDENSATE TRAP DETAIL N.T.S. SUPPLY AIR DUCT A/C UNIT UNIT -"—REFRIGERANT—PIPING ACCESS PANELS FACING DOORWAY RUBBER PADS (4) T/1 18 r FINISHED FLOOR \1 1 /2"x1 1 /2"x1 /4" ANGLE WELDED _'STEEL STAND W/PLATES ANCHORED TO SLAB. ALTERNATE CAN BE 2"x4" WOOD VERTICAL AND HORIZONTAL SUPPORTS. TYPICAL UNIT INSTALLATION