10-151-008R]Ev(SION- ely, 1) EXTEND BOTTOM BARS 8' PAST ALL OPENINGS GREATER THAN Y-O" ON BOTH SIDES. 2) TIE BEAMS SHALL BE CONTINUOUS REINFORCEMENT, PROVIDED BY LAPPING SPLICES NOT LESS THAN 30". CONTINUITY SHALL BE PROVIDED AT ALL CORNERS BY BENDING 2 BARS FROM EACH DIRECTION AROUND THE CORNER 30" OR BY ADDING 20 5 BENT 30' EACH LEG. 3) CONTINUITY AT COLUMNS SHALL BE PROVIDED BY CONTINUING HORIZONTAL REBARS THRU COLUMNS OR BY BENDING HORIZONTAL REW. INTO COLUMNS A DISTANCE OF 30". 4) HOOK TOP OF VERTICAL BARS N ALL TERMINATING COLUMNS 2' BELOW TOP OF SLAB AND 3' BELOW TOP OF THE TIE BEAM. 1) STRUCTURAL CONCRETE SHALL CONFORI'i w/ ACI-301 IT SHALL REACH A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI IN 28 DAYS FOR SLABS t FOOTING. 2) AGGREGATES SHALL BE CLEAN AND GRADED MAXIMUM SIZES 3/4" CONCRETE ASTM C-33 SHALL CONFORM TO ASTM C-94 3) CONCRETE TESTING IS REQUIRED AS FOLLOWS: I SET OF 5 CYLINDERS FOR EVERY 50 CU, YES. OF CONCRETE AS PER ASTM C-94 4) MAX" PERMISSIBLE SLUMP IS 5-6' IN STRUCTURAL CONCRETE w/ THE EXCEPTION BEING SAND CEMENT GROUT 5) REINFORCING STEEL SHALL CONFORM TO ASTM A-615 GRADE 60. REINFORCING STEEL SHALL BE DETAILED AND FABRICATED ACCORDING TO THE " MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES'. HOOK ALL DISCONTINUOUS TOP RENFORCNG. PROVIDE CORNERS w/ 2.5 X 4'-0' BARS. CLEAR COVER FOR RENFORCNG BARS SHALL BE: FOOTINGS 3' UNFORMED FACES — 3' SLABS 3/4' FORMED FACES N BEAMS/COLUMNS _ 1 Vl" CONTACT w/ EART14— 2" Watlaftwl • APPLICABLE CODES: A: FJ3L 20M EDITION. B: ALJ. 318-05 REINFORCED CONCRETE C•. REINFORCED MASONRY BY AC-1 530-05 AND THE MASONRY DESIGNERS GUIDE BY AL.I, TM, AS.C.E. E: WND ANALYSIS AND DESIGN PER A S.CE7-05. REINFORCING STEEL fy ■ 600M PS.L fa - 240M PSJ. Es - 29OW l00 PSJ. Em ■ 1,350,000 P.S.I. N - Ee/Em - 2L48 ALL BLOCK 8' ASTM C-90 HOLLOW UNIT MASONRY DESIGN fht ■ i,52i0 P.S.I. t F'a - 1,900 PSJ. (PER TABLE 2 ACI 530.1) GROUT SHALL COMPLY w/ ASTM C416, 28 DAYS MR COMP. STRENGTH - 30M P.S.I. GROUT SLUMP REQUIRED ----- 8' TO 11" PROVIDE CLEANOUT HOLES AT TOPMIDDLE AND BOTTOM OF FILLED CELL MORTAR SHALL COMPLY w/ ASTM 210 MORTAR SLUMP REQUIRED ----- 5" TO 8' CONTRACTOR TO CONSOLIDATE GROUT LIFTS w/ 3/4" VIBRATOR PLYWOOD ROOF DIAPHRAGM L ROOF DIAPHRAGM SHALL COMPLY w/ THE DES194 REC 1 ENDATIONS OF 'APA DESIGN / CONSTRUCTION GUIDE - DIAPHRAGMS' AND THE LOCAL BUILDING CODE. 2. PLYWOOD ROOF DECKING SHALL BE 1952" MINIMUM THICKNESS, AND SHALL BE CONTINUOUS OVER TWO OR MORE SPANS, w/ FACE GRAN PERPENDICULAR TO T14E SUPPORTS. 3. CONNECT PLYWOOD DIAPHRAGM TO STRUCTURE w/ Bd RING SHANK NAILS, SPACED AT 6'oc, MAX. AT EDGES AND AT 6"or- ALONG INTERMEDIATE SUPPORTS. 4" or- * DIAPHRAM BOUNDARY AND 8d RING SHANK NAILS s 4" or- 0 GABLE ENDS. 4. INSPECTIONS: SHALL COMPLY w/ THE LOCAL BUILDING CODE RECIAREMENITS FOR INSPECTIONS (BY THE MUNICIPALITY, ARCHITECT OR ENGINEER) OF SPECIFIED COMPONENTS OF THE ROOF STRUCTURE REQUIRING INSPECTIONS. SOIL COMPACTION NOTES L REMOVE ALL VEGETATION, TOPSOIL, AND ORGANIC MATERIAL w/ N THE BUILDING AREA PLUS FIVE (5) FEET OUTSIDE THE BUILDING FOOTPRINT. THE AREA UNDER FOOTINGS, FOUNDATIONS, AND CONCRETE SLABS ON GRADE SHALL HAVE ALL VEGETATION, STUMPS, ROOTS, AND FOREIGN MATERIALS REMOVED PRIOR TO PLACEMENT OF FILL- 2. COMPACT THE CLEARED AREA TO A MINIMUM COMPACTION OF 95 PERCENT OF THE DRY SOIL DENSITY AS DETERMINED BY THE MODIFIED PROCTOR TEST-ASTM D-B51 PRIOR TO KXZ ETNT OF ANY ADDITIONAL FILL REQUIRED. 3. FILL AND COMPACT THE CLEARED AREAS N LIFTS NOT GREATER THAN 12 NC -ES OF LOOSE THICKNESS TO ELEVATE TO THE REQUIRED GRADE FILL MATERIAL FOR AREAS N SUPPORT OF FOOTINGS IS TO BE A MIXTURE OF LIMEROCK AND SAND, FREE OF VEGETATION, ORGANIC MATERIAL, CONSTRUCTION DEBRIS, AND LARGE ROCKS. F SUFFICIENT CO'IPACTIBILITIES EXIST, SOILS MAY BE PLACED AND COMPACTED N GREATER LIFT THICKNESSES. FILL MATERIAL FOR SLAB ON GRADE AREAS MAY BE CLEAN SAND, FILLED AND COMPACTED IN LIFTS NOT GREATER THAN 12 INCHES OF LOOSE MATERIAL 4. COMPACT EACH LIFT TO A MINIMUM COMPACTION OF W PERCENT OF THE DRY SOIL DENSITY AS DETERMINED BY THE MODIFIED PROCTOR TEST - ASTM 0-1551 PRIOR TO PLACEMENT OF ANY ADDITIONAL FILL REQUIRED, PRIOR TO COMPACTION, THE MOISTURE CONTENT OF EACH LIFT OF FILL MATERIAL SHALL BE ADJUSTED TO w/N PLUS/MNUS 2 PERCENT OF THE OPTIMUM MOISTURE AS DETEI;MNED BY THE MODIFIED PROCTOR TEST - ASTM D-1551. 5. COMPACTION OF BUILDING SITE SHALL BE VERIFIED BY MEANS OF ONE FIELD DENSITY TEST FOR EACH 25M SQUARE FEET OR FRACTION THEREOF FOR EACH LIFT OF COMPACTED SOIL FOR BUILDING PAD OR SLAB AREA - ONE FIELD DENSITY TEST WILL ALSO BE REQUIRED FOR EVERY 50 LINEAL FEET OF EXCAVATED SPREAD FOOTING, AND EVERY ISOLATED FOOTING EXCAVATION. FIELD DENSITY TESTS SHALL BE PERFORMED AS PER ASTM D-2922. STRUCTURAL STEEL n mom- rt L STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING: GRADES: A ALL UUF, ANGLE, BASE PLATES, CONN. PLATES NON)---ASTM (A% -36 KSU C, STEEL PTRUCIPE------------------ASTM A53A, iW EE BSM GRADE(FT-35- KSI) I} 2. GROUT SUCH AASMAMASTEER F OWOW 113, ASW MARFACTUD B MASTER BUILDERS OR APRROVED EQUALC. 3. ALL WELDING SHALL CONFORM TO THE REQUIREMENTS OF "THE STANDARD CODE FOR WELDING IN BUILDING CONSTRUCTION" OF THE AMERICAN WELDING SOCIETY. ALL WELDING SHALL BE PERFORMED BY CERTIFIED WELDERS USING E10-XX ELECTRDDES. GENERAL NOTES 0h \ U ALL POURED N PLACE GROUT FILL CELLS AND TIE BEAMS AND COLUMNS TO BE 3000 PSI AT 28 DAYS MN f lcw 2) ALL CONCRETE WORK IN ACCORDANCE w/ "SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDING" (ACI-301-%). _.......__ �.,. 3) NO ADMIXTURES PERMITTED w/OUT WRITTEN APPROVAL OF ENGINEER � 4) COMPACT INTEIRJOR FILL TO St OF MODIFIED PROCTOR MAX" DRY DENSITY AS PER ASTM D - 1551 AT OPT1h1UM MOISTURE COJ'tENt. 0 5) PRIOR TO CONSTRUCTION PROVIDE TERMITE PROTECTION TREATMENT TO SOIL N ACCORDANCE w/ NATIONAL PEST CONTROL ASSOCIATION' STANDARDS. SUBMIT TERMITE INSPECTION REPORT PRIOR TO CONSTRUCTION. 6) PROVIDE C.EANOItT OPENING AT THE BOTTOM OF REINFORCED MASONRY CELLS THAT ARE BEING FILLED TO ENSURE THAT THE CELL IS FILLED. PROVIDE DEEP HOLES AT I/3 AND 2/3 OF SPAN. j 1) ALL REIN. STEEL SHALL CONFORM TO ASTM. A-615 GRADE 60 REINFORCNG STEEL SHALL BE DETAILED �% % /4" AND FABRICATED ACCORDING TO THE'MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRICTURES' LAP CONTINUOUS REINFORCING A MIN. OF 30" N BEAMS 36 BAR DIAMETERS IN � ,, f. 1/01 SLABS. HOOK ALL DISCOdTINOUS TOP RENFORCING. PROVIDE AT ALL CORNERS 25 60" LONG BENT. j !% j ru 8) CLEAR COVER FOR REINFORCING SHALL BE: SLABS: T w/3/4' FOR-W FACES IN C—O EARTH _ 2" INFORMED FACES 9) ALL BLOCK MASONRY WALLS SHALL HAVE HORIZONTAL REINFORCEMENT " PA-0-WALL LADDER TYPE j SPACED Ib" ON CENTER USE PREFABRICATED CORNERS AND TEES BY "DUR-O-WALL AT CORNERS AND JUNCTIONS OF WALLS MASONRY WITS SHALL BE 2 CELL HOLLOW WITS CONFOFMINCs TO ASTM C-90 w/ COMPRESSIVE STRENGTH OF P" PSJ. ON THE NET CROSS -SECTIONAL AREA AND SHALL BE LAID 15790 SW 8 8 T H AVE N RUANNG BOND. MORTAR SHALL BE TYPE "S" w/ M - 1500 PSI. 10) THE USE OF A SCALE TO OBTAIN DIMENSIONS NOT 0-4-M ON THE PLANS IS STRICTLY FORBIDDEN. MIAMI, FL 33157 THE ENGINEER WILL NOT BE RESPONSIBLE FOR ERRORS RESULTING FROM SUCH ACTIONS. AR 0017521 11) CONTRACTOR TO LOCATE ALL EXISTING UTILITIES PRIOR TO EXCAVATION. NOTE: ALL DRAWINGS FOR THIS PROJECT ARE 12) USE CONCRETE MASONRY WITS C NIFORMING TO ASTM C90: DESIGN Pc-1900 PSJ. WHERE ANCHOR BOLTS TO BE READ IN CONJUNCTION WITH AIRE SET N MASONRY WALL, FILL BLOCK CELLS w/ GROUT FOR BOLTED COURSE ADD ONE GROUTED CELL EACH OTHER. THESE INCLUDE, BUT ABOVE AND TWO GROUTED CELLS BELOW ANCHOR ELEVATION. ARE NOT LIMITED TO: ARCHITECTURAL, SURVEYING, STRUCTURAL, CIVIL, 13) GROUT USED IN THE WORK SHALL CONFORM TO ASTM C416 w/ A SLUMP MINX OF 8' TO 117, PROVIDE C.EANOUT MECHANICAL, ELECTRICAL, SPECIALTY AND INSPECTION HOLES AT FILLED CELLS AT BOTTOM COURSE. ALL MORTAR SHALL CONFORM w/ ASTM C210. DRAWINGS, & WRITTEN SPECIFICATIONS. CONTRACTOR TO VERIFY ALL EXISTING 14) POUR GROUT N LIFTS NOT TO EXCEED 4'. SITE CONDITIONS AND THOROUGHLY CHECK ELEVATIONS AND DIMENSIONS 15) GROUT USED N THE WORK SHALL OBTAN A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI IN 28 DAYS. GROUT BEFORE COMMENCING WORK. SLUMP REQUIRED ----- 8' To II" PROVIDE CLEANOUT HOLES AT TOP, MIDDLE. REPORT TO THE ARCHITECT ENGINEER ANY DISCREPANCIES, ERRORS OR 16) A SPECIAL INSPECTION BY A FL CERTIFIED ENGINEER OR SPECIAL INSPECTOR, WILL BE REQUIRED FOR ALL CONDITIONS THAT WILL ALTER ENGINEERED MASONRY CONSTRUCTION, SOIL COMPACTION AND ROOF TRUSSES OVER 35' LONG OR 6'-0' HIGH. CONSTRUCTION AS INTENDED BY THESE DRAWINGS. ARCHITECT IS rT) ALL SPECIFIED MATERIALS AND CONNECTORS CAN BE SUBSTITUTED w/ EQUAL OR BETTER, w/ THE NOT RESPONSIBLE FOR ANY WORK APPROVAL OF ENGINEER OF RECORD AND/OR MATERIALS FURNISHED ON THE JOB. 18) ALL STRUCTURAL LUMBER TO BE SOUTHERN PINE No. 2 OR BETTER All graphic material appearing herein, MINIMUM BENDING STRESS, Flo - 1;00 PSL YOUNG'S MODULES, E-IW,000 PSI. unless indicated otherwise, are the property of the Architect as instruments of service for use solely on this project, and may not be duplicated, used or disclosed without the written consent of Mark E. Reardon, R.A. The architect retains all common law, statutory and other reserved rights. -�• jtp WIND DESIGN FER ASCE 1-05 MEAN ROOF HEIGHT 4I3'-0" WIND DESIGN SPEED W6 MPH EXPOSURE C STRUCTL AL CATEGORY II Kel 1.0 SHOP DRAWING NOTES PRIOR TO ANY FABRICATION, SHOP DRAWINGS SHALL BE SUBMITTED TO THE STRUCTURAL ENGNEER FOR REVIEW AND APPROVAL w + q 4 b° ,\ e YA 0 o� LL V. Z W 0 L' - a J `Q U Z � 4 Z Ca a�N= Innnm In- 0� Cl 0 o �0 0 MER DATE: 2/21/10 AS NOTED SHEET NO.: S-0