10-151-004ALL CEILING AND WALL FINISHES TO HAVE FLAME SPREAD
CLASSIFICATION NOT GREATER THAN 200, AND AS PER
FBC 200-1 R315.1.
INTERIOR ALTERATIONS WITHIN THiS SCOPE OF WORK ARE
CLASSIFIED AS "LEVEL 2" AS PER 200"1 FBC SECTION 304.
CODE REFERENCE- 200-1 FLORIDA BUILDING CODE
AT ALL WALL HUNG ITEMS PROVIDE 20 GA STUDS 0
16" O.C. W/ 2" X 6" WOOD BLOCKING. SEE TYPICAL
INTERIOR PARTITION DETAIL ON A-5
LEGEND:
EXIST. 8" CMU WALL TO REMAIN
0 EXISTING INTERIOR PARTITION
TO REMAIN.
NEW INTERIOR PARTITION WiTH 25 GA 3-5/8" METAL
® STUDS 0 24" O.C. W/ 1/2" GYP BD EA SiDE.
® NEW DOOR, SEE DOOR SCHEDULE.
0 NEW DOOR, SEE DOOR SCHEDULE.
INDICATES LEVEL FLOOR ON BOTH SIDES OF OPENING.
NOTES:
DIMENSIONS INCLUDING CMU WALLS ARE TAKEN FROM
THE APPLICABLE FACE OF THE CMU WALL.
ALL PLUMBING AND ELECTRICAL FIXTURES
TO BE SELECTED BY OWNER t G.C.
ALL MILLWORK TO BE SELECTED BY OWNER
t G.G.
ABBREVIATiONS(APPLICABLE TO ALL SHEETS)
O.C. ON CENTER
AFF. ABOVE FINISHED FLOOR
VJF. VERIFY IN FIELD
A.F.G. ABOVE FINISHED GRADE
U.OX UNLESS OTHERWISE NOTED
TYP TYPICAL
CONT. CONTINUOUS
KEY NOTES
O Ceiling: new 1/2" drywall on 1"x3" metal hi -hats at I6" on
center. Typical unless otherwise noted.
5/8" drywall on 3/4" P.T. furring strips at 24" on
O center with R-4.1 foil insulation. Typical on new perimeter
concrete block walls unless otherwise noted.
�, 5/8" drywall on 3-5/8" 25 ga. metal studs at 24" O.C. w/ 5/8" gyp bd
<;/ ea. side. Typical for new interior partitions. See detail 2/A-5.
Infill existing window opening w/ all cmu. See typical infill details
on struct dwg's.
At showers and tubs, provide non absorbant, water resistant
O the up to min 12" a.ff.
Qall glass at showers and tubs to be CAT II rated.
OCloset shelving- "ELFA" platinum reach in shelving system, or
apporved equal by owner.
TYP WALL
SECTION
EXIST DOOR
TO REMAIN
EXIST WINDOW
TO REMAIN
EXIST WINDOW
TO REMAIN
FLOOR PLAN
SCALE: 1/4" = V-4"
tAIaµ%
i%oN
6
,pRpVE08� C10D
�a
CITY OF •
BUILDING DEPT.
STRUCTURAL SECTION
0, .xy