02-509-1874= 12 5702 -12P -12H TORO ADJ. POP-UP SPRAY <12) 7
GEST 570Z-12P-4EST TORO ADJ, POP-UP SPRAY (12') 8
E5 SST 570Z-12P-4SST TORO ADJ. POP-UP SPRAY (12') 14
®ST 570Z-12P-4SSST TORO ADJ, POP-UP SPRAY (12') 21
• P220-26-06 TORO 1 1/2' SOLENOID VALVE 9
q 'A' ESP-12LX RAIN BIRD AUTO CONTROLLER 1
NOT SHOWN 502C HILTON RAIN SENSOR 1
v 825Y (2') FEBCO REDUCED PRESSURE ASSEMBLY 1
NOT SHOWN #14 AWG PAIGE OF WIRE AS REQUIRED
#14 AWG VALVE CONTROL
#12 AWG VALVE COMMON
NOT SHOWN SCH 40 GALVANIZED STEEL AS REQUIRED
SCH 40 PVC AS REQUIRED
—"' — MAIN
_ — — SLEEVES
❑ SHRUB RISERS
NOT SHOWN PVC FITTINGS
X — WIRE CONDUIT
TYPE 1120 PVC LATERALS AS REQUIRED
SDR 26, CLASS 160 (1' & LARGER)
SDR 21, CLASS 200 <3/4')
-►�- GATE VALVES (TO LINE SIZE) 3
•►� VALVE BOX/COVER 12
NOT SHOWN GROUNDING LOCATION 1
® CITY WATER METER 1
NOTE+ ABOVE QUANTITIES ARE FOR COMPARISON ONLY.
CONTRACTOR SHALL VERIFY PRIOR TO SUBMITTING BID.
ZONE SUMMARY CHART
STA SPRINKLER VALVE WATER RUN WEEKLY
NO. TYPE SIZE DEMAND W TIME USAGE
CONTROLLER 'A'
1 SPRAY - 1 1/2' 47 GPM 60 MIN/WK 2,820 GAL/WK
2 SPRAY 1 1/2' 49 GPM 60 MIN/WK 2,940 GAL/WK
3 SPRAY 1 1/2' 61 GPM 60 MIN/WK 3,660 GAL/WK
4 SPRAY 1 1/2' 65 GPM 60 MIN/WK 3,900 GAL/WK
5 SPRAY 1 1/2' 61 GPM 60 MIN/WK 3,660 GAL/WK
6 SPRAY 1 1/2' 62 GPM 60 MIN/WK 3,720 GAL/WK
7 SPRAY 1 1/2' 59 GPM 60 MIN/WK 3,540 GAL/WK
8 SPRAY 1 1/2' 46 GPM 60 MIN/WK 2,760 GAL/WK
9 SPRAY 1 1/2' 51 GPM 60 MIN/WK 3,060 GAL/WK
10-12 SPARE
30,060 GAL/WK
W TO APPLY 1.5 IN/WK
IRRIGATI❑N NOTES & SPECIFICATI❑NS
AUTOMATIC IRRIGATION SYSTEM
WATER DEMAND / ZONE REFER TO PLAN
WATER SOURCE 2' CITY WATER METER
PRESSURE REQUIRED 60 PSI
GENERAL
IRRIGATION SHALL BE INSTALLED IN ACCORDANCE WITH LOCAL CODES,
CONTRACT DRAWINGS, AND CONTRACT SPECIFICATIONS.
IRRIGATION DESIGN BASED ON FUSTER 'LANDSCAPING PLAN' DATED
MAY 16, 2002. CONTRACTOR SHALL REFER TO THIS PLAN TO COORDINATE
SPRINKLER LOCATIONS AND PIPE ROUTING WITH NEW AND EXISTING PLANT
L❑CATIONS.
THIS IRRIGATION PLAN SHALL BE USED AS A GUIDE ONLY. CONTRACTOR
SHALL INSTALL IRRIGATION TO MATCH ON SITE CONDITIONS AND TO
OVERCOME THE INHERENT INACCURACIES THAT RESULT WHEN DESIGNING
FROM BASE PLANS SCALED AT 1' = 8' AND 1' = 16'.
THIS IRRIGATION HAS BEEN DESIGNED AS A TYPICAL BLOCK VALVE TYPE USING
TORO SPRINKLERS AND IN-LINE VALVES AND A RAIN BIRD CONTROL SYSTEM. A
RAIN SENSOR SHALL BE INCLUDED TO CONSERVE WATER.
GATE VALVES SHALL BE INSTALLED FOR ISOLATION. EACH VALVE SHALL
BE TO LINE SIZE AND INSTALLED IN A VALVE BOX, POROUS MATERIAL SHALL
BE INSTALLED PER BOX TO PROMOTE DRAINAGE.
SPRINKLERS
SPRINKLER LOCATIONS ARE SCHEMATIC ONLY AND SHALL BE ADJUSTED
FOR LANDSCAPING, SITE LIGHTING, PREVAILING WIND, MOUNDING, ETC. TO
INSURE PROPER COVERAGE WITH MINIMAL UNDESIRABLE OVERTHROW,
SPRAY HEADS SHALL BE TORO 570 SERIES, SIX INCH POP-UP TYPE SHALL BE
INSTALLED IN AREAS LANDSCAPED WITH SOD AND MULCH, TWELVE INCH
POP-UP TYPE SHALL BE INSTALLED IN AREAS LANDSCAPED WITH GROUND
COVER AND LOW SHRUBS, AND SHRUB HEADS AND BUBBLERS SHALL BE
INSTALLED IN AREAS LANDSCAPED WITH TALL SHRUBS AND PALMS.
POP-UP TYPE SHALL BE INSTALLED ON FLEXIBLE SWING JOINTS CONSISTING OF
THICK WALLED POLY PIPE AND 1/2' INSERT ELBOWS.
SHRUB TYPE AND BUBBLERS SHALL BE INSTALLED ON 1/2' SCH 40 PVC RISERS.
SHRUB HEADS SHALL BE INSTALLED A STANDARD HEIGHT OF 6' ABOVE PLANTS
AND SHALL BE INSTALLED WITHIN PLANTS TO BE CONCEALED FROM VIEW.
BUBBLERS SHALL BE INSTALLED AT THE BASE OF TALL SHRUBS FOR LOW LEVEL
WATERING. RISERS SHALL BE PAINTED FLAT BLACK TO BE LESS VISIBLE.
EACH SPRAY HEAD SHALL BE EQUIPPED WITH THE APPROPRIATE MPR NOZZLE .
ADJUSTMENT FEATURES OF SPRINKLERS SPECIFIED SHALL BE UTILIZED TO
INSURE PROPER COVERAGE WITH MINIMAL UNDESIRABLE OVERTHROW. LOW
ANGLE, FLAT SPRAY, AND ADJUSTABLE ARC NOZZLES SHALL BE USED TO
MINIMIZE OVERTHROW;
SPRINKLERS LOCATED ADJACENT TO HARDSCAPED AREAS SHALL BE INSTALLED
AWAY FROM HARDSCAPED AREAS TO MINIMIZE OVERTHROW AND THE CHANCE
OF DAMAGE BY VEHICLES, PEDESTRIANS, AND LAWN MAINTENANCE
PERSONNEL. AS A GENERAL RULE, 6- POP—UP SPRAY HEADS SHALL BE
INSTALLED IN 4', SHRUB HEADS AND 12' POP—UP SPRAY HEADS SHALL BE
INSTALLED IN 12'.
CONTROL SYSTEM
A RAIN BIRD ESP SERIES ELECTRIC CONTROL SYSTEM SHALL BE INSTALLED•
ONE 12 STATION CONTROLLER SHALL ACTIVATE 9 IN-LINE VALVES. ONE
VALVE SHALL BE CONTROLLED PER STATION EXCEPT AS NOTED. A RAIN
SENSOR SHALL BE INSTALLED TO CONSERVE WATER.
CONTROLLER SHALL BE INSTALLED IN ACCORDANCE WITH LOCAL CODES
AND MANUFACTURER'S INSTRUCTIONS. PROPER GROUNDING EQUIPMENT
SHALL BE PROVIDED.
CONTROLLER LOCATION SHALL BE APPROVED BY THE OWNER'S
REPRESENTATIVE. A 110 VAC ELECTRIC SOURCE IS REQUIRED PER
LOCATION.
CONTROL LINES FROM AUTOMATIC CONTROLLER TO IN-LINE AUTOMATIC
VALVES SHALL BE #14 AWG UNDERGROUND FEED TYPE WHICH SHALL BEI (1)
INSTALLED IN ACCORDANCE WITH LOCAL CODES, (2) ROUTED IN V WIRE
CONDUIT THROUGHOUT, (3) BURIED TO A MINIMUM DEPTH OF 15', (4) COLOR
CODED TO FACILITATE TROUBLESHO❑TING, AND (5) SPLICED MOSTLY AT VALVE
LOCATIONS, SPLICES SHALL BE MADE WATERPROOF USING APPROVED
METHODS. SPARE WIRES SHALL BE ROUTED FROM THE CONTROLLER IN ALL
DIRECTI❑NS TO THE FARTHEST VALVES CONTROLLED.
AN INDIVIDUAL CONTROL WIRE SHALL BE ROUTED TO EACH VALVE AND
VALVES WHICH OPERATE SIMULTANEOUSLY SHALL BE TEED TOGETHER AT,
THE CONTROLLER.
AUTOMATIC VALVE LOCATIONS ARE SCHEMATIC ONLY AND SHALL BE
ADJUSTED FOR ON SITE CONDITIONS. EACH VALVE SHALL BE INSTALLED IN
A VALVE BOX. A MINIMUM OF ONE CUBIC FOOT OF GRAVEL SHALL BE
PROVIDED PER BOX TO PROMOTE DRAINAGE.
WATER CONSERVATION EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE
WITH MANUFACTURER'S INSTRUCTIONS, EACH RAIN SENSOR SHALL BE PLACED
ON A STATIONARY STRUCTURE, MINIMUM OF 5' CLEARANCE FROM OTHER
OUTDOOR EQUIPMENT, FREE AND CLEAR OF ANY TREE CANOPY OR OTHER
OVERHEAD OBSTRUCTION, AND ABOVE THE HEIGHT OF SPRINKLER COVERAGE.
TIMING AND PRECIPITATION
TIMING OF EACH STATION SHALL BE SET IN THE FIELD TO MATCH LOCAL
REQUIREMENTS. REFER TO ZONE SUMMARY CHART FOR RECOMMENDED RUN
TIMES TO APPLY 1,5 INCHES/WEEK,
MPR PLUS NOZZLES
(SIZE PER PLAN)
SHRUB ADAPTER
�t� W
0
APPROVED BACKFILL
APPROVED RISER
LATERAL TEE
LATERAL PIPE
SHRUB/BUBBLER SPRINKLER
NOT TO SCALE
WALK OR ROA
••
�p.new
LATERAL —�
SHRUB HEAD.
SHRUB MASS.
SHRUB RISER.
21/ POP-UP
/ \ \ HEAD.—�
iu POLV. PIPE
'" SWING RISER
4' or8'
SPRINKLER L❑CATI❑N DETAIL
NOT TO SCALE
COVER
5/8- DIAMETER
COPPER CLAD ROD.
' RESISTANCE TO EARTH
'"--• SHALL BE WITHIN LIMITS
t• SET BY CONTROLLER
MANUFACTURER.
GROUNDING ROD INSTALLATION
NOT TO SCALE
4" MAX.—,
PLASTIC VALVE BOX
WITH COVER MARKED
"IRRIGATION"
112- IN TURF AND
2 IN GROUND
COVER AREAS
FINISH GRADE
MPR PLUS NOZZLES
(SIZE PER PLAN)
NOTE: INSTALL SPRINKLER
AT FINISHED GRADE
=T71� I� I I U►— APPROVED BACKFILL
SPRAY SPRINKLER
BARBED MALE ELL
FUNNY PIPE
LATERAL PIPE
LATERAL TEE
POP-UP SPRINKLER ON
POLY PIPE SWING J❑INT
NOT TO SCALE
MPR PLUS NOZZLES
(SIZE PER PLAN)
-J1�i1-jL- I i I NOTE: INSTALL SPRINKLER
AT FINISHED GRADE
I I -III -III -III -I I L- I I I -I I I I I f
STI=�J I f-1 fL=1 I I I APPROVED BACKFILL
NOTE: CONTRACTOR MAY
INSTALL PIPE TO SIDE
INLET
SPRAY SPRINKLER
BARBED MALE ELL
FUNNY PIPE
LATERAL PIPE
LATERAL TEE
12" POP-UP SPRINKLER ON
POLY PIPE SWING J❑INT
NOT TO SCALE
FINISH GRADE.
�—
REMOTE CONTROL VALVE
TOP SOIL
BLACK
VALVES AND TWO GALV.
AOVIDE
W
3 , 13
NIPPLES
A 2' CITY ER ERHALL
ER O
THE SHALL
TT TABOVET60 SYSTEM
TO -
BUNDLE IRRIGATION
ORANGE
NIPPLE
LEGEND
CONTROL WIRES AT
BROWN
NOTED IN
VERIFY AT IT YE PRESSU EE IS MAINTAINED PSI W ENC T❑HE
10' INTERVALS AND
WIRES (PROVIDE 24 OF
10 . 20
o
PROVIDE 1' EXPANSION
WHITE
SCH 80 PVC NIPPLE
Z
LOOP AT 50' INTERVALS.
IS PROGRAMMED TO OPERATE,
'
SYMBOL
M❑DEL NO,
DESCRIPTION
W
PVC MALE ADAPTER
EST,
QUANTITY
BACKFILL WITH PREVIOUSLY
A
570S–FBIOO–PC
TORO
ADJ,
SHRUB
BUBBLER
7
BACKFLOW PREVENTION SHALL BE INSTALLED TO MEET LOCAL CODE
A
570S-SB90
TORO
ADJ.
SHRUB
BUBBLER
4
REQUIREMENTS FOR CROSS CONNECTION CONTROL. A REDUCED PRESSURE
A
570S-SB180
TORO
ADJ,
SHRUB
BUBBLER
122
ASSEMBLY HAS BEEN SPECIFIED.
N 6' FOR PIPE 2' AND SMALLER
570S-SB360
TORO
ADJ.
SHRUB
BUBBLER
3
LARGER WHERE CONTROL WIRE
m
570S-2SB180
2SB18
TORO
ADJ,
SHRUB
BUBBLER
177
1
CONTRACTOR IS ADVISED TO STUDY THE PLANS FOR ADDITIONAL
5' TO TRENCH WALL.
4' FOR PIPE OR CONDUIT 2'
INFORMATION AND TO VISIT THE SITE TO BECOME FAMILIAR WITH EXISTING
FOR
p 6a
570S -MJ
TORO
ADJ.
SHRUB
SPRAY
CONDITIONS,
p 80
570S -8Q
TORO
ADJ,
SHRUB
SPRAY
5
In 8H
570S -8H
TORO
ADJ.
SHRUB
SPRAY
9
TO INSURE PROPER OPERATION, SOURCE SIZE, VALVE SIZES, ZONE
p 100
570S-100
TORO
ADJ,
SHRUB
SPRAY
5
CAPACITIES, SPRINKLER SPACING, PIPE AND WIRE SIZES, INSTALLATION
p 107
570S-1
TORO
ADJ.
SHRUB
SPRAY
2
NOTES AND DETAILS, AND SPECIFICATIONS SHALL BE FOLLOWED AS SHOWN.
M 10H
570S -10H
TORO
ADJ.
SHRUB
SPRAY
9
S lora
570S-10TO
TORO
ADJ.
SHRUB
SPRAY
1
F19 120
570S -12Q
TORO
ADJ.
SHRUB
SPRAY
7
PIPING
Cl 12T
570S -12T
• TORO
ADJ.
SHRUB
SPRAY
2
PIPE ROUTING IS SCHEMATIC ONLY AND SHALL BE ADJUSTED FOR ON SITE
In 12H
570S -12H
TOR❑
ADJ.
SHRUB
SPRAY
18
CONDITIONS.
S 12TO
570S-12TO
TORO
ADJ.
SHRUB
SPRAY
2
GEST
570S-4EST
TORO
ADJ.
SHRUB
SPRAY
6
PIPE SHALL BE INSTALLED IN ACCORDANCE WITH LOCAL CODES AND PIPE
0 ssr
570S-4SST
TORO
ADJ,
SHRUB
SPRAY
9
MANUFACTURER'S INSTRUCTIONS.
BST
570S-4SSST
TORO
ADJ.
SHRUB
SPRAY
7
E]15T
570S -15T
TORO
ADJ.
SHRUB
SPRAY
2
PIPE ROUTED UNDER HARDSCAPED AREAS SHALL BE SLEEVED IN SCH 40 PVC.
B 15H
570 -
TORO
ADJ.
SHRUB
SPRAY
1
EACH SLEEVE SHALLI (1) BE BURIED TO A MINIMUM DEPTH OF 18', (2) BE TWO
O 8H
570Z -6P -8H
TORO
ADJ
POP-UP
SPRAY
(6')
9
PIPE SIZES LARGER THAN CARRIER PIPE, AND <3> EXTEND 3' BEYOND
3 l0
5702 -6P -10V
TORO
ADJ
POP-UP
SPRAY
(6')
4
HARDSCAPED AREA,
0100
570Z -6P -10Q
TORO
ADJ
POP-UP
SPRAY
(6')
12
e 10H
• IOF
570Z -6P -10H
570Z -6P -10F
TORO
TORO
ADJ
ADJ
POP-UP
POP-UP
SPRAY
SPRAY
(6')
(6')
6
5
PIPE INSTALLED ABOVE GRADE FOR THE BACKFLOW PREVENTER SHALL BE
012v
570Z -6P -12V
TORO
ADJ
POP-UP
SPRAY
(6')
1
SCH 40 GALVANIZED STEEL, ALL OTHER PIPING SHALL BE TYPE 1120 PVC, THE
(3120
570Z -6P -12Q
TORO
ADJ
POP-UP
SPRAY
(6')
3
MAIN LINE AND WIRE CONDUIT SHALL BE SCH 40. LATERALS SIZED 1' AND
C 12H
570Z -6P -12H
TORO
ADJ
POP-UP
SPRAY
<6')
33
LARGER SHALL BE SDR 26, CLASS 160. LATERALS SIZED 3/4' SHALL BE SDR 21,
0 12T
570Z-6P-12TO
TORO
ADJ
POP-UP
SPRAY
(6')
1
CLASS 200.
•12F570Z-6P-12F
TORO
ADJ
POP-UP
SPRAY
(6')
5
p sr
EST
4E
5702-6P-4EST
TORO
ADJ
POP-UP
SPRAY
C6')
3
PIPE SIZED TO LIMIT FLOW VELOCITIES TO 5 FEET/SECOND AND TO LIMIT
0 SST
570Z-6P-4SST
TORO
ADJ
POP-UP
SPRAY
(6')
19
FRICTION LOSS IN THE PIPING NETWORK.
®ST
570Z-61P-4SSST
TORO
ADJ
POP-UP
SPRAY
(6')
8
0150
570Z -6P-150
TORO
ADJ
POP-UP
SPRAY
(6')
3
PIPE SHALL BE INSTALLED SO BACKFILL DEPTHS ARE MAINTAINED AT 18'
615H
570Z -6P -15H
TORO
ADJ
POP-UP
SPRAY
(6')
22
FOR THE MAIN LINE AND LATERALS ROUTED UNDER PAVEMENT, AND AT 12'
(3 80
570Z -12P -8Q
TORO
ADJ.
POP-UP
SPRAY
(12')
2
FOR ALL OTHER LATERALS,
C 8H
570Z -12P -8H
TORO
ADJ.
PDP -UP
SPRAY
(12')
9
01ov
570Z -12P -10V
TORO
ADJ,
POP-UP
SPRAY
(12')
3
BACKFILL SHALL BE OF SUITABLE MATERIAL, FREE OF ROCKS, STONES, AND
0100
570Z-12P-IOQ
TORO
ADJ,
POP-UP
SPRAY
(12')
4
OTHER DEBRIS THAT WOULD DAMAGE IRRIGATION SYSTEM COMPONENTS,
p 10T
570Z-12P-IOT
TORO
ADJ.
POP-UP
SPRAY
(12')
5
�5 IGH
570Z -12P -10H
TORO
ADJ,
POP-UP
SPRAY
(12')
4
THE BACKFLOW PREVENTER SHALL BE INSTALLED IN ACCORDANCE WITH
0120
570Z -12P -12Q
TORO
ADJ.
POP-UP
SPRAY
(12')
10
LOCAL CODES AND SHALL BE LOCATED TO BE CONCEALED FROM VIEW.
(5 12T
570Z -12P -12T
TORO
ADJ.
POP-UP
SPRAY
(12')
1
H
•
4= 12 5702 -12P -12H TORO ADJ. POP-UP SPRAY <12) 7
GEST 570Z-12P-4EST TORO ADJ, POP-UP SPRAY (12') 8
E5 SST 570Z-12P-4SST TORO ADJ. POP-UP SPRAY (12') 14
®ST 570Z-12P-4SSST TORO ADJ, POP-UP SPRAY (12') 21
• P220-26-06 TORO 1 1/2' SOLENOID VALVE 9
q 'A' ESP-12LX RAIN BIRD AUTO CONTROLLER 1
NOT SHOWN 502C HILTON RAIN SENSOR 1
v 825Y (2') FEBCO REDUCED PRESSURE ASSEMBLY 1
NOT SHOWN #14 AWG PAIGE OF WIRE AS REQUIRED
#14 AWG VALVE CONTROL
#12 AWG VALVE COMMON
NOT SHOWN SCH 40 GALVANIZED STEEL AS REQUIRED
SCH 40 PVC AS REQUIRED
—"' — MAIN
_ — — SLEEVES
❑ SHRUB RISERS
NOT SHOWN PVC FITTINGS
X — WIRE CONDUIT
TYPE 1120 PVC LATERALS AS REQUIRED
SDR 26, CLASS 160 (1' & LARGER)
SDR 21, CLASS 200 <3/4')
-►�- GATE VALVES (TO LINE SIZE) 3
•►� VALVE BOX/COVER 12
NOT SHOWN GROUNDING LOCATION 1
® CITY WATER METER 1
NOTE+ ABOVE QUANTITIES ARE FOR COMPARISON ONLY.
CONTRACTOR SHALL VERIFY PRIOR TO SUBMITTING BID.
ZONE SUMMARY CHART
STA SPRINKLER VALVE WATER RUN WEEKLY
NO. TYPE SIZE DEMAND W TIME USAGE
CONTROLLER 'A'
1 SPRAY - 1 1/2' 47 GPM 60 MIN/WK 2,820 GAL/WK
2 SPRAY 1 1/2' 49 GPM 60 MIN/WK 2,940 GAL/WK
3 SPRAY 1 1/2' 61 GPM 60 MIN/WK 3,660 GAL/WK
4 SPRAY 1 1/2' 65 GPM 60 MIN/WK 3,900 GAL/WK
5 SPRAY 1 1/2' 61 GPM 60 MIN/WK 3,660 GAL/WK
6 SPRAY 1 1/2' 62 GPM 60 MIN/WK 3,720 GAL/WK
7 SPRAY 1 1/2' 59 GPM 60 MIN/WK 3,540 GAL/WK
8 SPRAY 1 1/2' 46 GPM 60 MIN/WK 2,760 GAL/WK
9 SPRAY 1 1/2' 51 GPM 60 MIN/WK 3,060 GAL/WK
10-12 SPARE
30,060 GAL/WK
W TO APPLY 1.5 IN/WK
IRRIGATI❑N NOTES & SPECIFICATI❑NS
AUTOMATIC IRRIGATION SYSTEM
WATER DEMAND / ZONE REFER TO PLAN
WATER SOURCE 2' CITY WATER METER
PRESSURE REQUIRED 60 PSI
GENERAL
IRRIGATION SHALL BE INSTALLED IN ACCORDANCE WITH LOCAL CODES,
CONTRACT DRAWINGS, AND CONTRACT SPECIFICATIONS.
IRRIGATION DESIGN BASED ON FUSTER 'LANDSCAPING PLAN' DATED
MAY 16, 2002. CONTRACTOR SHALL REFER TO THIS PLAN TO COORDINATE
SPRINKLER LOCATIONS AND PIPE ROUTING WITH NEW AND EXISTING PLANT
L❑CATIONS.
THIS IRRIGATION PLAN SHALL BE USED AS A GUIDE ONLY. CONTRACTOR
SHALL INSTALL IRRIGATION TO MATCH ON SITE CONDITIONS AND TO
OVERCOME THE INHERENT INACCURACIES THAT RESULT WHEN DESIGNING
FROM BASE PLANS SCALED AT 1' = 8' AND 1' = 16'.
THIS IRRIGATION HAS BEEN DESIGNED AS A TYPICAL BLOCK VALVE TYPE USING
TORO SPRINKLERS AND IN-LINE VALVES AND A RAIN BIRD CONTROL SYSTEM. A
RAIN SENSOR SHALL BE INCLUDED TO CONSERVE WATER.
GATE VALVES SHALL BE INSTALLED FOR ISOLATION. EACH VALVE SHALL
BE TO LINE SIZE AND INSTALLED IN A VALVE BOX, POROUS MATERIAL SHALL
BE INSTALLED PER BOX TO PROMOTE DRAINAGE.
SPRINKLERS
SPRINKLER LOCATIONS ARE SCHEMATIC ONLY AND SHALL BE ADJUSTED
FOR LANDSCAPING, SITE LIGHTING, PREVAILING WIND, MOUNDING, ETC. TO
INSURE PROPER COVERAGE WITH MINIMAL UNDESIRABLE OVERTHROW,
SPRAY HEADS SHALL BE TORO 570 SERIES, SIX INCH POP-UP TYPE SHALL BE
INSTALLED IN AREAS LANDSCAPED WITH SOD AND MULCH, TWELVE INCH
POP-UP TYPE SHALL BE INSTALLED IN AREAS LANDSCAPED WITH GROUND
COVER AND LOW SHRUBS, AND SHRUB HEADS AND BUBBLERS SHALL BE
INSTALLED IN AREAS LANDSCAPED WITH TALL SHRUBS AND PALMS.
POP-UP TYPE SHALL BE INSTALLED ON FLEXIBLE SWING JOINTS CONSISTING OF
THICK WALLED POLY PIPE AND 1/2' INSERT ELBOWS.
SHRUB TYPE AND BUBBLERS SHALL BE INSTALLED ON 1/2' SCH 40 PVC RISERS.
SHRUB HEADS SHALL BE INSTALLED A STANDARD HEIGHT OF 6' ABOVE PLANTS
AND SHALL BE INSTALLED WITHIN PLANTS TO BE CONCEALED FROM VIEW.
BUBBLERS SHALL BE INSTALLED AT THE BASE OF TALL SHRUBS FOR LOW LEVEL
WATERING. RISERS SHALL BE PAINTED FLAT BLACK TO BE LESS VISIBLE.
EACH SPRAY HEAD SHALL BE EQUIPPED WITH THE APPROPRIATE MPR NOZZLE .
ADJUSTMENT FEATURES OF SPRINKLERS SPECIFIED SHALL BE UTILIZED TO
INSURE PROPER COVERAGE WITH MINIMAL UNDESIRABLE OVERTHROW. LOW
ANGLE, FLAT SPRAY, AND ADJUSTABLE ARC NOZZLES SHALL BE USED TO
MINIMIZE OVERTHROW;
SPRINKLERS LOCATED ADJACENT TO HARDSCAPED AREAS SHALL BE INSTALLED
AWAY FROM HARDSCAPED AREAS TO MINIMIZE OVERTHROW AND THE CHANCE
OF DAMAGE BY VEHICLES, PEDESTRIANS, AND LAWN MAINTENANCE
PERSONNEL. AS A GENERAL RULE, 6- POP—UP SPRAY HEADS SHALL BE
INSTALLED IN 4', SHRUB HEADS AND 12' POP—UP SPRAY HEADS SHALL BE
INSTALLED IN 12'.
CONTROL SYSTEM
A RAIN BIRD ESP SERIES ELECTRIC CONTROL SYSTEM SHALL BE INSTALLED•
ONE 12 STATION CONTROLLER SHALL ACTIVATE 9 IN-LINE VALVES. ONE
VALVE SHALL BE CONTROLLED PER STATION EXCEPT AS NOTED. A RAIN
SENSOR SHALL BE INSTALLED TO CONSERVE WATER.
CONTROLLER SHALL BE INSTALLED IN ACCORDANCE WITH LOCAL CODES
AND MANUFACTURER'S INSTRUCTIONS. PROPER GROUNDING EQUIPMENT
SHALL BE PROVIDED.
CONTROLLER LOCATION SHALL BE APPROVED BY THE OWNER'S
REPRESENTATIVE. A 110 VAC ELECTRIC SOURCE IS REQUIRED PER
LOCATION.
CONTROL LINES FROM AUTOMATIC CONTROLLER TO IN-LINE AUTOMATIC
VALVES SHALL BE #14 AWG UNDERGROUND FEED TYPE WHICH SHALL BEI (1)
INSTALLED IN ACCORDANCE WITH LOCAL CODES, (2) ROUTED IN V WIRE
CONDUIT THROUGHOUT, (3) BURIED TO A MINIMUM DEPTH OF 15', (4) COLOR
CODED TO FACILITATE TROUBLESHO❑TING, AND (5) SPLICED MOSTLY AT VALVE
LOCATIONS, SPLICES SHALL BE MADE WATERPROOF USING APPROVED
METHODS. SPARE WIRES SHALL BE ROUTED FROM THE CONTROLLER IN ALL
DIRECTI❑NS TO THE FARTHEST VALVES CONTROLLED.
AN INDIVIDUAL CONTROL WIRE SHALL BE ROUTED TO EACH VALVE AND
VALVES WHICH OPERATE SIMULTANEOUSLY SHALL BE TEED TOGETHER AT,
THE CONTROLLER.
AUTOMATIC VALVE LOCATIONS ARE SCHEMATIC ONLY AND SHALL BE
ADJUSTED FOR ON SITE CONDITIONS. EACH VALVE SHALL BE INSTALLED IN
A VALVE BOX. A MINIMUM OF ONE CUBIC FOOT OF GRAVEL SHALL BE
PROVIDED PER BOX TO PROMOTE DRAINAGE.
WATER CONSERVATION EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE
WITH MANUFACTURER'S INSTRUCTIONS, EACH RAIN SENSOR SHALL BE PLACED
ON A STATIONARY STRUCTURE, MINIMUM OF 5' CLEARANCE FROM OTHER
OUTDOOR EQUIPMENT, FREE AND CLEAR OF ANY TREE CANOPY OR OTHER
OVERHEAD OBSTRUCTION, AND ABOVE THE HEIGHT OF SPRINKLER COVERAGE.
TIMING AND PRECIPITATION
TIMING OF EACH STATION SHALL BE SET IN THE FIELD TO MATCH LOCAL
REQUIREMENTS. REFER TO ZONE SUMMARY CHART FOR RECOMMENDED RUN
TIMES TO APPLY 1,5 INCHES/WEEK,
MPR PLUS NOZZLES
(SIZE PER PLAN)
SHRUB ADAPTER
�t� W
0
APPROVED BACKFILL
APPROVED RISER
LATERAL TEE
LATERAL PIPE
SHRUB/BUBBLER SPRINKLER
NOT TO SCALE
WALK OR ROA
••
�p.new
LATERAL —�
SHRUB HEAD.
SHRUB MASS.
SHRUB RISER.
21/ POP-UP
/ \ \ HEAD.—�
iu POLV. PIPE
'" SWING RISER
4' or8'
SPRINKLER L❑CATI❑N DETAIL
NOT TO SCALE
COVER
5/8- DIAMETER
COPPER CLAD ROD.
' RESISTANCE TO EARTH
'"--• SHALL BE WITHIN LIMITS
t• SET BY CONTROLLER
MANUFACTURER.
GROUNDING ROD INSTALLATION
NOT TO SCALE
4" MAX.—,
PLASTIC VALVE BOX
WITH COVER MARKED
"IRRIGATION"
112- IN TURF AND
2 IN GROUND
COVER AREAS
FINISH GRADE
MPR PLUS NOZZLES
(SIZE PER PLAN)
NOTE: INSTALL SPRINKLER
AT FINISHED GRADE
=T71� I� I I U►— APPROVED BACKFILL
SPRAY SPRINKLER
BARBED MALE ELL
FUNNY PIPE
LATERAL PIPE
LATERAL TEE
POP-UP SPRINKLER ON
POLY PIPE SWING J❑INT
NOT TO SCALE
MPR PLUS NOZZLES
(SIZE PER PLAN)
-J1�i1-jL- I i I NOTE: INSTALL SPRINKLER
AT FINISHED GRADE
I I -III -III -III -I I L- I I I -I I I I I f
STI=�J I f-1 fL=1 I I I APPROVED BACKFILL
NOTE: CONTRACTOR MAY
INSTALL PIPE TO SIDE
INLET
SPRAY SPRINKLER
BARBED MALE ELL
FUNNY PIPE
LATERAL PIPE
LATERAL TEE
12" POP-UP SPRINKLER ON
POLY PIPE SWING J❑INT
NOT TO SCALE
FINISH GRADE.
�—
REMOTE CONTROL VALVE
TOP SOIL
BLACK
VALVES AND TWO GALV.
AOVIDE
W
3 , 13
NIPPLES
4.14
TO -
BUNDLE IRRIGATION
ORANGE
NIPPLE
MAINLINE(COVER AS
'LEGEND
CONTROL WIRES AT
BROWN
NOTED IN
COMMON AND COBOL
10' INTERVALS AND
WIRES (PROVIDE 24 OF
10 . 20
o
PROVIDE 1' EXPANSION
WHITE
SCH 80 PVC NIPPLE
Z
LOOP AT 50' INTERVALS.
NIPPLE
'
c
SCH 40 GALV. ELL
W
PVC MALE ADAPTER
C3
BACKFILL WITH PREVIOUSLY
SCH 40 GAL. NIPPLE
EXCAVATED MATERIAL.
.;✓
0`
SOW
PIPE
SAND OR FINE MATERIAL
1 CU.FT. CONC. THRUST BLOCKS
PVC MAIN (COVER AS NOTED IN LEGEND)
•. PASSING 1/4' SIEVE.
:'• ;.
• • PIPE OR CONDUIT (TYP.)
N 6' FOR PIPE 2' AND SMALLER
AND 12' FOR PIPE 2 1/2' AND
LARGER WHERE CONTROL WIRE
IS IN SAME TRENCH - IF ONLY
ONE PIPE IN TRENCH, PROVIDE
5' TO TRENCH WALL.
4' FOR PIPE OR CONDUIT 2'
AND SMALLER AND 12'
FOR
PIPE 2 1/2' AND LARGER.
OUTSIDE WALL
TRENCHING DETAIL
NOT TO SCALE
HYBRID CONTROLLER:
RAIN BIRD ESP SERIES
OUTDOOR WALL MOUNT
1.5 -INCH PVC SCH 40 CONDUIT
AND FITTINGS
JUNCTION BOX
1 -INCH PVC SCH 40 CONDUIT
TO POWER SUPPLY
WIRES TO REMOTE CONTROL
VALVES
ESP WALL MOUNT CONTROLLER
NOT TO SCALE
EPDXY FILLED
CONNECTORS
LATERAL UNE (COVER
AS NOTED IN LEGEND)
SOLENOID ACTUATED
�—
REMOTE CONTROL VALVE
WIRE
COMQF
REIN
BLACK
VALVES AND TWO GALV.
AOVIDE
W
3 , 13
NIPPLES
4.14
IN 2 PVC CONDUIT.
4" x 2-1/4" x 8" SOLID
ORANGE
NIPPLE
MAINLINE(COVER AS
'LEGEND
BRICK AT EACH CORNER
BROWN
NOTED IN
COMMON AND COBOL
0 . 19
WIRES (PROVIDE 24 OF
10 . 20
WRE IN A COIL, EA.)
COMMON
WHITE
SCH 80 PVC NIPPLE
MAINLINE (COVER AS
NOTED IN LEGEND)
NOTE:
USE 45 ELLS IMMEDIATELY OUTSIDE OF VALVE BOX, AS
NECESSARY, FOR TRANSITION M REQUIRED LATERAL UNE DEPTH.
REMOTE CONTROL VALVE DETAIL
NOT TO SCALE
LU CONCRETE VALVE BOX
CL
Z ME V .MARKED
.. GROUND U&2" IN
FINISH GRADE
NOMINAL 4" x 2 1 4' x 8"
SOLID BRICK AT EACH CORNER
NOTE:
USE 45 ELLS IMMEDIATELY OUTSIDE OF VALVE BOX, AS
NECESSARY, FOR TRANSITION TO REQUIRED MAINLINE DEPTH.
GATE VALVE DETAIL
NOT TO SCALE
SCH 40 GALV. ELL
SCH 40
yr/HV"0 MESH MONEL SCREEN
OSE BIB FOR FLUSHING
�—
BACKFLOW PREVENTION
UNIT INCLUDES TWO GATE
1 . 11
BLACK
VALVES AND TWO GALV.
RED
3 , 13
NIPPLES
4.14
SCH 40 GALV.
5 , 15
ORANGE
NIPPLE
BLUE
7 , 17
BROWN
ELL 40 GALV.
PURPLE
0 . 19
SCH 40 GALV. NIPPLE
10 . 20
GREY
COMMON
WHITE
SCH 40 GALV.
PINK
SCH 40 GALV. NIPPLE
NIPPLE
'
FINISH GRADE
SCH 40 GALV. ELL
PVC MALE ADAPTER
SCH 40 GALV.
NIPPLE
(24- MIN COVER)
SCH 40 GAL. NIPPLE
,.
SCH 40 GALV. ELL
SOW
PVC MALE ADAPTER
1 CU.FT. CONC. THRUST BLOCKS
PVC MAIN (COVER AS NOTED IN LEGEND)
REDUCED PRESSURE_ BACKFLOW PREVENTER
MINI–CLIK HOUSING
MADE FROM U.V. STABILIZED
VALOX. THERMOPLASTIC
CLICK STOP SETTINGS— MEASURE
RAINFALL IN QUANTITIES OF 1/8- TO 1"
71- ADJUSTABLE VENTILATION HOLES
ALUMINUM MOUNTING BRACKET --� 0
TOTALLY SEALED & LEAD WIRES
WEATHERPROOF CH
MECHANISM (U.L.TSTED) 0
MINI-CLIK II RAIN SENSOR
NOT TO SCALE
PIPE SLEEVE DETAIL
NOT TO SCALE
WIRE COLOR CODING CHART
STATION A
WIRE COLOR
1 . 11
BLACK
2 , 12
RED
3 , 13
GREEN
4.14
YELLOW
5 , 15
ORANGE
8 , 18
BLUE
7 , 17
BROWN
8.18
PURPLE
0 . 19
TAN
10 . 20
GREY
COMMON
WHITE
SPARE
PINK
NOT TO SCALE
GATE VALVE
PVC MALE ADAPTER
PVC MAINLINECO
AS NOTED IN Gl D
1 CU. FT. PEA GRAVEL
(4" LAYER MINIMUM)
E
z
a
0
a
w
a
w
a�
ca
P%4
z
Z Emm,
PQ �
c�
x
E
O
ssvm®
JULY -11-02
U Z
PN/ KDD
Dulm 194
E.FUSTER
This drawing is the property
of Fuster Design Associates P.A.
It is an instrument of service
that cannot be reproduced in
any way without written consent.
SHEET
14
1.4
OF FOUR