Loading...
02-509-179FIRE SPRINKLER NOTES: 1. ALL FIRE SPRINKLER WORK SHALL BE DONE ACCORDING TO LATEST N.F.P.A. 13, STATE AND LOCAL CODES AND ORDINANCES. 2. CONTRACTOR SHALL PAY ALL FEES, INSPEC- TION AND CONNECTION CHARGES REQUIRED. 3. SPRINKLER CONTRACTOR SHALL VERIFY ALL SPACE CONDITIONS AND DIMENSIONS AT JOB SITE PRIOR TO FABRICATION AND INSTALL- ATION OF MATERIALS AND EQUIPMENT. 4. COORDINATE WORK WITH OTHER TRADES. 5. SUBMIT SHOP DRAWINGS TO ENGINEER FOR APPROVAL OF ALL EQUIPMENT, MATERIALS, LAYOUTS AND CALCULATIONS, PRIOR TO INSTALLATION. 6. SPRINKLER CONTRACTOR SHALL GUARANTEE ALL WORK FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM DATE OF ACCEPTANCE. 7. SPRINKLER LEGEND: SIDE WALL SPRINKLER HEAD • PENDANT SPRINKLER HEAD 9 FLOW SWITCH —►�— CHECK VALVE O.S. & Y VALVE —F— FIRE LINE F.D.V. FIRE DEPARTMENT VALVE SPK. SPRINKLER F.D.C. FIRE DEPARTMENT CONNECTION O FIRE EXTINGUISHER 8. FIRE LINES [INCLUDING FIRE SPRINKLER LINES 1. UNDERGROUND: J.M. BLUEPRINT CLASS 200 P.V.C. 2. ABOVE GROUND: SCHEDULE 10 ALLIOED XL -IN CONCEALED SPACE AND INSIDE APTS OR CPVC INSIDE APARTMENTS. 3. SPRINKLER STANDPIPE SHALL BE SCHEDULE 10 BLACK STEEL PIPE WITH GROOVED FITTINGS. REDUCING COUPLING 2" 3/8" MIN. 1 " MAX. 'CENTRAL' MODEL BVR RECESSED PENDENT 9. SPRINKLER HEAD SCHEDULE/LEGEND PUMP NUMBER HANGER DETAIL JP -1 ORIFICE APPLICATION DROP-IN ANCHOR JOCKEY PUMP PARKING LOCATION a d a 4 d • < d e PUMP ROOM K14ECOH P 4 . • .. n�r2'' a2d < " SLAB 300 6 C) X3 POWDER DRIVEN STUD0 45 91 3/8" ROD COUPLING/8" 2HILTI #W10 -27—P10) 60 1,5 O 3/8" ALL THREAD ROD 3500 3500 M SWIVEL --ADJUSTABLE HANGER RING (ITT GRINNELL #69) 208/60/3 208/60/3 BV -QR RING (ALUMN. OR GALVANIZED) ODP ODP P PIPE(SIZE VARIES) VERTICAL IN LINE VERTICAL O +. (SIZES 1" TO 4") FAIRBANKS MORSE FAIRBANKS MORSE 1557 TYPICAL HANGER DETAIL 4"1591 BF F391-50 N.T.S. 4"x4" PIPE SIZE ROD SIZE CONSTRUCTION TYPE OF MIN. 'C' MAX. 'C' SEAL PACKING MECHANICAL FASTENER DIM. DIM. 3/4" 3/8" 1-3/8" X 1-17/32" DROP-IN ANCHOR 1/2" 1-5/8- -5/8"1" 1. 5/8" 1-3/4" 1-1/4" 13/16" 1-7/8" 1-1/2„ 15/16” 2- 2- 1-3/16 2-3/8- -3/8"2-1/2" 2-1/2- 1/2- ' 1-1/2" X 2-1/32" DROP-IN ANCHOR 1-7/16" 2-3/4" 3" 1-3/4" 3-1/4" 3-1 /2" 2" 3-5/8- 4" 5/8- 1-5/8" X 2-15/32" DROP-IN ANCHOR 2-1/4" 3-7/8" 5" 2-3/4" 4-3/4" 6" 3/4- 1-3/4" X 3-1/4", DRP. -IN ANC. 3-5/16- 5-1/2- 8- N/A N/A N/A N/A FIRE SPRINKLER NOTES: 1. ALL FIRE SPRINKLER WORK SHALL BE DONE ACCORDING TO LATEST N.F.P.A. 13, STATE AND LOCAL CODES AND ORDINANCES. 2. CONTRACTOR SHALL PAY ALL FEES, INSPEC- TION AND CONNECTION CHARGES REQUIRED. 3. SPRINKLER CONTRACTOR SHALL VERIFY ALL SPACE CONDITIONS AND DIMENSIONS AT JOB SITE PRIOR TO FABRICATION AND INSTALL- ATION OF MATERIALS AND EQUIPMENT. 4. COORDINATE WORK WITH OTHER TRADES. 5. SUBMIT SHOP DRAWINGS TO ENGINEER FOR APPROVAL OF ALL EQUIPMENT, MATERIALS, LAYOUTS AND CALCULATIONS, PRIOR TO INSTALLATION. 6. SPRINKLER CONTRACTOR SHALL GUARANTEE ALL WORK FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM DATE OF ACCEPTANCE. 7. SPRINKLER LEGEND: SIDE WALL SPRINKLER HEAD • PENDANT SPRINKLER HEAD 9 FLOW SWITCH —►�— CHECK VALVE O.S. & Y VALVE —F— FIRE LINE F.D.V. FIRE DEPARTMENT VALVE SPK. SPRINKLER F.D.C. FIRE DEPARTMENT CONNECTION O FIRE EXTINGUISHER 8. FIRE LINES [INCLUDING FIRE SPRINKLER LINES 1. UNDERGROUND: J.M. BLUEPRINT CLASS 200 P.V.C. 2. ABOVE GROUND: SCHEDULE 10 ALLIOED XL -IN CONCEALED SPACE AND INSIDE APTS OR CPVC INSIDE APARTMENTS. 3. SPRINKLER STANDPIPE SHALL BE SCHEDULE 10 BLACK STEEL PIPE WITH GROOVED FITTINGS. REDUCING COUPLING 2" 3/8" MIN. 1 " MAX. 'CENTRAL' MODEL BVR RECESSED PENDENT 9. SPRINKLER HEAD SCHEDULE/LEGEND SYMBOL PUMP NUMBER FP -1 JP -1 ORIFICE APPLICATION FIRE PUMP JOCKEY PUMP PARKING LOCATION PUMP ROOM PUMP ROOM K14ECOH P G.P.M. 300 6 C) PSI 45 91 U MAXIMUM HP 60 1,5 O R.P.M. 3500 3500 M VOLTAGE 208/60/3 208/60/3 BV -QR MOTOR TYPE ODP ODP P PUMP TYPE VERTICAL IN LINE VERTICAL O MANUFACTURER FAIRBANKS MORSE FAIRBANKS MORSE 1557 MODEL 4"1591 BF F391-50 SIZE 4"x4" 11A"X1 k" CONSTRUCTION BF STAINLESS STEEL STOR RMS. SEAL PACKING MECHANICAL S OPERATING WEIGH - LBS 577 50 UPRIGHT C • APARTMENTS 4.3 155'F 7/16" BVR CENTRAL H E D U L E ACCESSORIES: CLASS 125 DISCARGE FLANGE CLASS 125 4" TEST HEADER, 1%" VALVES, CAPS,CHAINS CLASS 250 CIRCULATION VALVE SHALL BE KUNKLE MODEL 918 3/4" 0-300 PSI COMPOUND SUCTION AND 0-300 PSI DISCHARGE GAUGE SET OF CALSS 250 FLANGES FOR JOCKEY PUMP HUBBELL LX 1500 LIMITED SERVICE, 18000 AIC. HUBBELL LX 600 JOCKEY PUMP CONTROLLER WITH 3 FUSES. SYMBOL SERVICE K FACTOR TEMP. RATING ORIFICE MODEL MFG. X PARKING 14.0 1557 0.7" K14ECOH CENTRAL Q GARAGE W C) UPRIGHT <..0 L� O PAIINTED < • ON 5.6 155'F 1/2" BV -QR CENTRAL 1 AREA PENDANT O COMMON 5.6 1557 1/2" BV -QR CENTRAL AREA O SIDEWALL O STOR RMS. 5.6 155'F 1/2" BV -QR CENTRAL STAIRS UPRIGHT • APARTMENTS 4.3 155'F 7/16" BVR CENTRAL REC PEND ' APARTMENTS 5.4 1557 1/2- BVR SW CENTRAL 10. SIAMESE CONNECTIONS SHALL BE GUARDIAN MODEL 133 OR EQUAL. 11. ROOF MANIFOLD SHALL BE GUARDIAN MODEL 210 OR EQUAL. 12. FIRE PUMP TEST HEADERS SHALL BE GUARDIAN MODEL 516 OR EQUAL. 13. TESTS; WATER PIPING: TEST TO 50 PSI BEYOND THE HIGHEST ANTICIPATED PRESSURE. NOTE: ALL LOW POINTS TO BE EQUIPPED WITH AUXILIARY DRAINS PER NFPA 13 ROD COUPLINGS w POWDER DRIVEN STUD_ 6 ALL THREAD ROD �, PIPE RING POWDER DRIVEN STUD HANGER 3/4" MAX. 3/8" MIN. REDUCING COUPLING f 2 1/2" 'CENTRAL' MODEL BVR 1/2" RECESSED SIDEWALL ROOF "Y" CONNECTION W/ (2) CENTRAL 2 1/2" )7 HOSE VALVES W/ 1 1/2" `O RESTRICTOR COUPLING N ROOF FLASHING ROOF LEVEL 1 w CLQ - 0 z V ROOF MANIFOLD DETAIL NTS BRANCH LINE BRANCHLINE ` " 1 X ARMOVER 1"X 0'-2" NIPPLE LENGTH AS REQUIRED / 1" 90 EL. 1" X DROP `LENGTH AS REQUIRED 1 " X 1/2" R.C. SEMI -RECESSED PENDENT W/ ESCT. SUSPENDED CEILING TYP. SWING AND DROP ASSEMBLY 'CENTRAL' MODEL 'BV -OR' UPRIGHT PRESSURE REGULATING GR. X GR. BUTTERFLY VA. W/ TAMPER SWITCH POTTER 300 Ib. PRESSURE r FLOW SWITCH GAUGE TO SYSTEM w F-- az o V) UNION =[D\ -SECT. DRAIN VA. TEST VA. -SIGHT GLASS SPRINKLER CONTROL ASSY. DETAIL NTS CPVC PIPE STRAP CPUC PIPE HEX HEAD SELF /TAPPING SCREW f DOUBLE FASTENER CPVC PIPE STRAP HANGER APPLICATION 0 RESTRAINER APPLICATION CPUC PIPE/ 0 .F' HEX HEAD SELF TAPPING SCREW' T SINGLE FASTENER CPVC PIPE STRAP ;LAMP N./BOLT & NUT ASSMB. / ��lc RISER CLAMP CONCRETE ANCHOR BALL THREAD ROD PIPE RING DRILLED CONC. ANCHOR HANGER OS&Y WITH WATTS MODEL 709 TAMPER SWITCH BACK FLOW PREVENTOR DETAIL —SUPPORT FROM SLAB WITH GRINNEL CONCRETE INSERTS GALVANIZED STEEL RODS PROPERLY SIZED —� STEEL CHANNEL TRAPEEZE HANGER DETAIL N.T.S. PIPE RISER - C -CLAMP � C -CLAMP WITH LOCKNUT RISER CLAMP f SLAB co) de .e e a d `ALL THREAD ROD a. d. a ,•d . --- PIPE RING PIPE SLEEVE C -CLAMP HANGER J //—STANDPIPE STANDPIPE cr w CL M D 0 APPROVED FOR BUILDING PERMITTING PURPOSES BY MIAMI -DADS COUNTY FIRE DEPARTMENT FIRE PROTECTION CONTRACTOR'S WORKING PLAN AS PER NFPA 13 SHALL BE SUBMITTED FOR APPROVAL TO MIAMI-DADE FIRE DEPARTMENT BEFORE ANY FIRE PROTECTION SYSTEM IS INSTALLED OR REMODELED 3" X 3" X 1" THICK CORK RIB PADS 0 • d • e W • d. SEAL WITH NON - HARDENING FIRE PROOF MASTIC AROUND PIPE SLAB OPENING TYPICAL VERTICAL WATER PIPE SUPPORT DETAILS N.T.S. DATE1'.2 pZ PLASTIC CEMENT " BITUMEN ON 1" PLASTIC CEMENT U io U.L. LISTED 2 1/2- ANGLE �n HOSE VALVE PRV WHERE REQ'D +1 1 I I FLOOR LEVEL FIRE HOSE VALVE DETAIL NTS ROOFING METAL BITUMEN POCKET INSULATION PIPE SLEEVE SLAB PIPE WRAP �,t�►�tt;itr��rf. SEAL WITH;`LA ALBERT SHUB �•`m`a`• ' PE# 0043414 M.E. HARDENING.,./ G i!:»IL �••. ti P•E20�; �� 1 • (� .- E80003862 FIRE ORIDA ENGINEERING SERVICES MASTIC= ARdUNM ECHANICAL AND ELECTRICAL PIPE SLAB : • ENGINEERS OPENING'%,,► , TYPICAL WATER Pit THROUGH ROOF D`"'ILS 34 N.W. 168TH STREET N.T.S. NORTH MIAMI BEACH, FL. 33169 TELEPHONE: (305) 653-0212 FAX: (305) 653-0232 REVISIONS 07-29-02 2 BLDG. DEPT./CORD. m. DRAWN CHECKED DATE 02-28-02 SCALE JOB NO. 02013 SHEET SP -10 OF SHEETS z W I- Q W C) <..0 L� O < ULu u-WQQ C) -LU 02 I-- 1 O U) O m. DRAWN CHECKED DATE 02-28-02 SCALE JOB NO. 02013 SHEET SP -10 OF SHEETS