02-509-169CW & HW SERVICE
RUN ABOVE CEILING
SEE FLOOR PLAN
FOR ROUTING
HEAT TRAP ----/
MINIMUM 3-1/2"
HEAT TRAP 1"
BELOW TOP
OF TANK
ASME RATED PRESSURE
TEMPERATURE (P & T)
RELIEF VALVE.
CW RISER.
T I
�-- RVD
RISER.
DP RISER
NON COMBUSTIBLE J
DRAIN PAN
3/4" RVD LINE DISCH._1___1_
11
TO OUTSIDE FINISH
6" ABOVE GRADE.
,&WATER HEATER PIPING DETAIL
N.T.S.
NOTES
WH -I LOCHINVAR MODEL ETJ030HH FF -1
30 GALLONS 3.0 KW 0 208 -1-60 VOLTS
DUAL ELEMENT NON -SIMULTANEOUS
ENERGY EFFICIENCY 0.89 OR EQUAL.
16.0 X 46 3/4" HEIGHT (UNITS A,B,C2 & E)
WH -2 LOCHINVAR MODEL ETJ052NN FF -1
50 GALLONS 5.5 KW O 208 -1-60 VOLTS
DUAL ELEMENT NON -SIMULTANEOUS
ENERGY EFFICIENCY 0.87 OR EQUAL.
20"0 X 46 3/4" HEIGHT (UNITS D,B1 & B2)
WH -3 LOCHINVAR MODEL ETJ040LL FF -1
40 GALLONS 4.5 KW 0 208 -1-60 VOLTS
DUAL ELEMENT NON -SIMULTANEOUS
ENERGY EFFICIENCY 0.88 OR EQUAL.
18"0 X 46 3/4" HEIGHT (UNITS C,C1 & C3)
WH -4 LOCHINVAR MODEL ETJ066NN FF -1
65 GALLONS 5.5 KW 0 208 -1-60 VOLTS
DUAL ELEMENT NON -SIMULTANEOUS
ENERGY EFFICIENCY 0.84 OR EQUAL.
20"0 X 58 3/4" HEIGHT (UNIT 131)
D
CONDENSATE
RISER A/c UNrr
HORIZONTAL RUN
INSULATED WITH
ARMAFLEX
2 -MIN. FOR 2-1/2 TONS OR LESS
3"MIN. FOR 3 TONS OR MORE
ACONDENSATE CONNECTION TO A/C
N.T.S.
A
D O
3735 Green Rd.
Beachwood, OH, 44122
Drawing not to scale
CD 2 -Hour Fire Rated gypsum wallboard/stud assembly.
Plastic Pipe - 1-1/2" dia. (or smaller) sch. 40 PVC pipe
for use in closed or vented pipin systems,
with a nom. annular space of 1%916 .
® A) TREMstop WS - wrap strips, tightly wrapped 3 times
around pipe.
B) TREMstop MCR - steel restricting collar.
C) FYRE-SIL - Min. 1/4" thick sealant applied to
wall/collar and collar/pipe interfaces.
PLUMBING LEGEND
�
G`0eatfjOUL
L
LAVATORY
W.H.
WATER HEATER
W.C.
WATER CLOSET
C.O.
CLEANOUT
T
TUB
V
VENT
SH
SHOWER
V.T.R.
VENT-THRU-ROOF
SK.
KITCHEN SINK
W
WASTE
WM
WASHING MACHINE
VS
VENT STACK
D.W.
DISHWASHER
SS
SOIL STACK
UR
URINAL
FCO
FLUSH CLEANOUT
BID
BIDET
ZURN
SOIL OR WASTE LINE
DF
DRINKING FOUNTAIN
ZURN
VENT LINE
S.SK
SERVICE SINK
-► -►
INDIRECT DRAIN
FD
FLOOR DRAIN W/ RESEAL
--
COLD WATER LINE
AC
AIR CONDITIONING
----
HOT WATER LINE
CB
CATCH BASIN
_CD -
CONDENSATE DRAIN LINE
RD
ROOF DRAIN
-RVD-
RELIEF VALVE DISCHARGE LINE
MH
MANHOLE
+
HOSE BIB W/BACK FLOW PREVENTER
CD
CONDENSATE DRAIN
CONSTRUCTION BRONZE FITTED
GATE VALVE
DP
DRAIN PAN-
SEAL MECHANICAL
GAGE LOCK
MECHANICAL
BWV
ST
STORM DRAIN
--
BACKFLOW PREVENTER
H.B.
HOSE BIB W/BACK-
G
GAS UNE
TANK:119GALLONS 0125 P.S.I.
FLOW PREVENTER
CIRCUIT BREAKER FOR EACH PUMP.
MOUNTING: 1st FLOOR
U
-�-
REDUCER
PRV
PRESSURE REDUCING VALVE
WITH STAINLESS STEEL MAIN SEATS.
ASM E: NO
L
�IIIF--
FLEXIBLE CONNECTION
RVD
RELIEF VALVE DISCHARGE
NO FLOW SYS. SHUT DOWN (NORMAL)
_DP-
DRAIN PAN LINE
GV
CATE VALVE
FLANGED ISOLATORS (RUBBER SPHERE)
- ST -
STORM DRAIN LINE
CV
CHECK VALVE
TEMP. PURGE FOR EACH PUMP
-�
PRESSURE GAGE
FU
FIXTURE UNITS
PROGRAMABLE PUMP SEQUENCE W/DIGITAL DISPLAY
24 HOUR EMERGENCY SERVICE FOR (1) YEAR ON SYSTEM
CHECK VALVE
HW
HOT WATER
PROGRAMABLE CONTROLLER
O
DP RISER
CW
COLD WATER
AUDIBLE ALARM (WITH SILENCER)
CD RISER
O
CW RISER
HIGH FLOW/PRESSURE SWITCH
OSANITARY
RISER
Q
RVD RISER
D O
3735 Green Rd.
Beachwood, OH, 44122
Drawing not to scale
CD 2 -Hour Fire Rated gypsum wallboard/stud assembly.
Plastic Pipe - 1-1/2" dia. (or smaller) sch. 40 PVC pipe
for use in closed or vented pipin systems,
with a nom. annular space of 1%916 .
® A) TREMstop WS - wrap strips, tightly wrapped 3 times
around pipe.
B) TREMstop MCR - steel restricting collar.
C) FYRE-SIL - Min. 1/4" thick sealant applied to
wall/collar and collar/pipe interfaces.
2 Hour Fire Rated Through
�
G`0eatfjOUL
Penetration Firestop for
Plastic Pipe through
DESCRIPTION
Gypsum Walls using
stems
m' tumescent devices
1&2065
F -rating = 2 Hr.
ZN415-P-NL-6B
T-ratinq = 1 Hr.
D O
3735 Green Rd.
Beachwood, OH, 44122
Drawing not to scale
CD 2 -Hour Fire Rated gypsum wallboard/stud assembly.
Plastic Pipe - 1-1/2" dia. (or smaller) sch. 40 PVC pipe
for use in closed or vented pipin systems,
with a nom. annular space of 1%916 .
® A) TREMstop WS - wrap strips, tightly wrapped 3 times
around pipe.
B) TREMstop MCR - steel restricting collar.
C) FYRE-SIL - Min. 1/4" thick sealant applied to
wall/collar and collar/pipe interfaces.
G�pe9 I f�
ep,
•
I" to
FA1005
(585)
F -rating = 2 Hr
T -rating = 1/4 Hr
D 0
e
3735 Green Rd.
Beachwood, OH, 44172
Drawing not to scale
Floor or wall assembly = 4 y: thick concrete
® Steel Pipe - 8" diam.(or smaller) Sch. 40 (or heavier)
steel. Annular space from Min 1/4" to Max 3 Ys
® A) Forming Material - Min 3 thickness ceramic fiber
insulation (Min 6 pcf), friction fitted.
fitted into annular space.
B) Min 132 " thickness FYRE-SIL S/L within annulus.
NOTE: For walls apply FYRE-SIL to both surfaces of wall.
DRAIN AND CLEANOUT SCHEDULE
ON 2" BITUMEN
SYMBOL
DESCRIPTION
MFG
MODEL
FD
TOILET ROOM -PUBLIC AREA
ZURN
ZN415-P-NL-6B
FD
PUMP RM.
ZURN
Z -645-41C
FD
TRASH ROOM
ZURN
Z541 -P
DO
GARAGE DRAIN
ZURN
Z150
DO
DECK DRAIN
ZURN
ZN415-8SH
PD
PLANTER DRAIN
ZURN
Z348
PD
PLANTER DRAIN -SUB SURFACE DRAINAGE
ZURN
Z348-PVCW/Z180-BS
RD
ROOF DRAIN
ZURN
ZC100-EA-C
FCO
FINISHED FLOOR CLEANOUT
ZURN
ZN1400-BP
CO
WALL CLEANOUT
ZURN
ZS1469
ECO
EXTERIOR CLEANOUT
ZURN
Z1400 -BP
G�pe9 I f�
ep,
•
I" to
FA1005
(585)
F -rating = 2 Hr
T -rating = 1/4 Hr
D 0
e
3735 Green Rd.
Beachwood, OH, 44172
Drawing not to scale
Floor or wall assembly = 4 y: thick concrete
® Steel Pipe - 8" diam.(or smaller) Sch. 40 (or heavier)
steel. Annular space from Min 1/4" to Max 3 Ys
® A) Forming Material - Min 3 thickness ceramic fiber
insulation (Min 6 pcf), friction fitted.
fitted into annular space.
B) Min 132 " thickness FYRE-SIL S/L within annulus.
NOTE: For walls apply FYRE-SIL to both surfaces of wall.
-SUPPORT FROM SLAB -
WITH GRINNEL CONCRETE
INSERTS
GALVANIZED STEEL RODS -
PROPERLY SIZED
STEEL CHANNEL
IRAPEEZE HANGER
N.T.S.
SUPPORT FROM SLABHANGING ROD
WITH GRINNEL CONCRETE
INSERTS
ADJUSTABLE
GALVANIZED STEEL CLEVIS PIPE
HANGER
0
PIPE --�
TYPICAL PPE HANCER DETAIL
N.T.S.
PLASTIC CEMENT
BUILDING
ON 2" BITUMEN
STRUCTURAL SLAB
MIN. 8
BITUMEN
CEMENT
POCKET
F.U.
COUNT
APPLICATION TRI PLEX DOMESTIC BOOSTER SYS.
TRI-PLEX DOMESTIC BOOSTER SYS.
TRI-PLEX DOMESTIC BOOSTER SYS.
P
LOCATION REMOTE
1
�
4.
1/2-
TIE HANGER ROD
INSULATION
TO NEAREST STEEL
GALVANIZED
STRUCTURAL BAR
STEEL ROD
NOTE:
SEAL WITH NON -HARDENING
THROUGHLY
GALVANIZED
PAINT STEEL
ADJUSTABLE
ROD & CLEVIS
CLEVIS
HANGER WITH TWO
R.P.M. 3500
HEAVY COATS OF
3500
BITUMASTIC PAINT,
MOUNTING 1 st FLOOR
AT TIME OF
1 st FLOOR
INSTALLATION.
PIPE
UNDEROROUM PPE SUPPORT
DETAL
N.T.S.
-SUPPORT FROM SLAB -
WITH GRINNEL CONCRETE
INSERTS
GALVANIZED STEEL RODS -
PROPERLY SIZED
STEEL CHANNEL
IRAPEEZE HANGER
N.T.S.
SUPPORT FROM SLABHANGING ROD
WITH GRINNEL CONCRETE
INSERTS
ADJUSTABLE
GALVANIZED STEEL CLEVIS PIPE
HANGER
0
PIPE --�
TYPICAL PPE HANCER DETAIL
N.T.S.
PLASTIC CEMENT
ROOFING
ON 2" BITUMEN
METAL
ON 1" PLASTIC
BITUMEN
CEMENT
POCKET
F.U.
COUNT
APPLICATION TRI PLEX DOMESTIC BOOSTER SYS.
TRI-PLEX DOMESTIC BOOSTER SYS.
TRI-PLEX DOMESTIC BOOSTER SYS.
P
LOCATION REMOTE
1
�
4.
1/2-
REMOTE
INSULATION
PIPE SLEEVE
SLAB
PIPE
WRAP
1/2-
SEAL WITH NON -HARDENING
97
FIRE PROOF MASTIC AROUND
M
PIPE SLAB OPENING
TYPICAL WATER
PPE
THROUGH ROOF DETA"
R.P.M. 3500
N.T.S.
3 H04r Fro R3ted ThroughLI WLSIJLI �D f-�
vws' fie Penetration Firestop for Single e
U ° Metal Pipe Through Concrete 3735 Green Rd.
floors or walls using Beachwood. OH, 44122
• FYRE-SIL or FYRE-SIL S/L
'r� s ter Drawing not to scale
CAa� F -rating = 3 Hr.
T -rating = 0 Hr.
2
2 3 1
3
Floor or Wall assembly = Min. 4-1/2" thick concrete
2 - Copper Pipe: 4" dia. (or smaller) copper
- Steel Pipe: 4" dia. (or smaller) sch.40 (or heavier) steel.
- Conduit: 4" dia. (or smaller) EMT or steel conduit.
- Copper Tubing: 4" dia. (or smaller) Type M
(or heavier) copper tubing
Applied within a Min. 1/2" annular space, Max. 3-3/8"
Q3 A) Packing Material - Min. 3-1/2" thick mineral wool
insulation, firmly packed into opening.
B) Min. 1/2" thick FYRE-SIL (floors or walls) or FYRE-
SIL S/L (floors only) applied within annulus. For
walls, apply to both surfaces of wall.
SPRING/RUBBER
ISOLATOR --�_
0
HANGING ROD
CLEVIS PIPE
HANGER
PIPRISER
RISER CLAMP�A
SLAB 0
SOUTH MIAMI APARTMENTS
�
SCHEDULE
ITEM
3" X 3" X 1" THICK
CORK RIB PADS
I O
I
I
I
P-3
F.U.
COUNT
APPLICATION TRI PLEX DOMESTIC BOOSTER SYS.
TRI-PLEX DOMESTIC BOOSTER SYS.
TRI-PLEX DOMESTIC BOOSTER SYS.
P
LOCATION REMOTE
1
�
..4 ., :. ...,.
1/2-
REMOTE
REMOTE
U
G.P.M. 68
PIPE SLEEVE
136
1/2-
T.D.H.(IN FT. WATER) 97
97
SEAL WITH NON -HARDENING
FIRE PROOF MASTIC AROUND
PIPE SLAB OPENING
TYPICAL VUMAL WATER PPE
SUPpm DETAL8
N.T.S.
1 2\
24" DIAMETER MANHOLE 90• DEGREE CLEAN
FRAME W/ SOLID LID- OUT/
HEAVY DUTY ��(TYP. 2) SAMPLING PORT
'TRAFFIC LID",,
DIA. VENT IN BAFFLE
-4 "CLEAN OUT 3"VENT CONN.
--4"CLEAN
OUT
6" .
MIN. M N. AX
WATER LINE 2'-0" TO VENT)
4"INLET BAFFLE MIN. 4"OUTLET LINE
NOTE: TOTAL CAPACITY SHALL
BE AS PER SECTION 4612.5
S.F.B.C.
15 MAX. OR VENTING
NEEDED AS PER S.F.B.C.
Q OIL INTERCEPTOR DETAIL
N.T.S
GENERAL PLUMBING NOTES
1. ALL WORK SHALL CONFORM WITH ALL LOCAL, STATE, FEDERAL ORDINANCES AND
BUILDING CODES GOVERNING THE INSTALLATION OF THE PLUMBING SYSTEM.
IF WORK AS LAID OUT, INDICATED OR SPECIFIED IS CONTRARY TO OR CONFLICTS
WITH LOCAL ORDINANCES, BUILDING CODES AND REGULATIONS, THE CONTRACTOR
SHALL REPORT IN WRITING TO THE ARCHITECT/ENGINEER BEFORE SUBMITTING A
BID. THE ARCHITECT/ENGINEER WILL THEN ISSUE INSTRUCTIONS AS HOW TO
PROCEED.
2. THE DRAWINGS ARE TO BE CONSIDERED DIAGRAMMATIC, NOT NECESSARILY
SHOWING IN DETAIL OR TO SCALE ALL OF THE MINOR ITEMS. UNLESS SPECIFIC
DIMENSIONS ARE SHOWN, THE STRUCTURAL, ARCHITECTURAL AND SITE CONDITIONS
SHALL GOVERN THE EXACT LOCATIONS. CONTRACTOR SHALL FOLLOW DRAWINGS IN
LAYING OUT WORK, CHECK DRAWINGS OF ALL TRADES TO VERIFY SPACES IN
WHICH WORK WILL BE INSTALLED AND MAINTAIN MAXIMUM HEAD ROOM, AND
SPACE CONDITIONS AT ALL POINTS. WHERE HEAD ROOM, OR SPACE CONDITIONS
APPEAR INADEQUATE, ARCHITECT/ENGINEER SHALL BE NOTIFIED BEFORE PROCEEDING
WITH INSTALLATION. THIS CONTRACTOR SHALL, WITHOUT EXTRA CHARGE, MAKE FIELD
MODIFICATIONS IN LAYOUT AS NEEDED TO PREVENT CONFLICT WITH WORK OF
VARIOUS TRADES OR FOR PROPER EXECUTION OF THE WORK.
3. EXAMINE ALL DRAWINGS CAREFULLY PRIOR TO SUBMITTING A BID. CONTRACTOR
WILL BE REQUIRED TO FURNISH, INSTALL AND/OR CONNECT WITH APPROPRIATE
SERVICES ALL PLUMBING ITEMS SHOWN ON ANY OF THE ARCHITECTURAL, AIR
CONDITIONING, ELECTRICAL AND SPRINKLER DRAWINGS WITHOUT ADDITIONAL EXPEN-
SE TO THE OWNER . IF DISCREPANCIES, CONFLICTS, INTERFERENCES OR OMISSIONS
OCCUR BETWEEN DRAWINGS, NOTIFY IN WRITING THE ARCHITECT/ENGINEER IN
AMPLE TIME TO PERMIT REVISIONS BEFORE THE BIDS ARE SUBMITTED.
4. INSTALL MATERIALS AND EQUIPMENT IN A NEAT AND FIRST CLASS WORKMANLIKE
MANNER. THE OWNER RESERVES THE RIGHT TO DIRECT REMOVAL AND
REPLACEMENT OF ITEMS OF WHICH, IN HIS OPINION, DO NOT PRESENT A
NEAT AND WORKMANLIKE APPEARANCE. REMOVAL AND REPLACEMENT IS TO BE
DONE IMMEDIATELY WHEN DIRECTED BY THE OWNER IN WRITING, AT THE SOLE
EXPENSE OF THE CONTRACTOR.
5. START OF WORK BY CONTRACTOR SHALL BE CONSIDERED AS ACCEPTANCE
BY HIM OF ALL CLAIMS OR QUESTIONS AS TO SUITABILITY OF THE WORK OF
OTHER TRADES OR OTHER CONTRACTORS TO RECEIVE HIS WORK. THIS CONTRACT -
TOR SHALL REMOVE AND REPLACE, AT HIS EXPENSE, ALL PLUMBING WORK WHICH
MAY HAVE TO BE REMOVED BECAUSE OF INTERFERENCES WITH OTHER TRADES.
6. THIS CONTRACTOR SHALL OBTAIN AND PAY ALL INSURANCE, FEES, PERMITS
ASSOCIATION DUES, ROYALTIES, AND TAXES OF WHATEVER NATURE SHALL APPLY
TO THIS WORK. HE SHALL ALSO PAY ALL INSPECTION FEES AS MAY BE REQUIRED
BY LAW OR ORDINANCE AND SHALL KEEP THE OWNER HARMLESS FROM ANY
DAMAGE AND EXPENSE ARISING FROM ANY VIOLATION OF THE LAWS, RULES OR
ORDINANCES.
7. PROVIDE MEANS "FURNISHED AND INSTALL".
8. DO A COMPLETE JOB, EVERYTHING CONNECTED, READY FOR USE.
9. SHOP DRAWINGS: THIS CONTRACTOR SHALL FURNISH THE ENGINEER WITH SHOP
DRAWINGS OF EQUIPMENT PRIOR TO PURCHASE FOR APPROVAL
10. AT COMPLETION OF JOB THE PLUMBING CONTRACTOR SHALL GIVE THE
OWNER AN AS -BUILT SET OF REPRODUCIBLE SEPIAS SHOWING THE EXACT
INSTALLATION.
11. PLUMBING CONTRACTOR SHALL PRESSURE TEST ALL PIPING AS REQUIRED BY
CODE. TEST SHALL BE WITNESSED AND APPROVED BY PROPER AUTHORITIES.
12. THE PLUMBING CONTRACTOR SHALL WARRANT ALL WORKMANSHIP AND MATERIALS
FOR ONE YEAR FROM THE DATE OF FINAL WORK ACCEPTANCE BY OWNER. ANY
BREAKDOWN OCCURRING IN FIRST YEAR SHALL BE REPAIRED AT NO EXPENSE TO
THE OWNER.
13. PLUMBING FIXTURES SHALL BE PROVIDED BY THE OWNER AND SHALL BE HANDLED /
INSTALLED BY THE PLUMBING CONTRACTOR. PLUMBING FIXTURE RELATED SUPPLIES (P -TRAPS,
ETC.) ARE NOT PART OF THE FIXTURE PLUMBING PACKAGE ALLOWANCE AND SHALL BE
PROVIDED BY THE PLUMBING CONTRACTOR. WATER HEATERS ARE NOT PART OF THE PLUMBING
FIXTURE PACKAGE AND SHALL BE PROVIDED BY THE PLUMBING CONTRACTOR.
14. PROVIDE SHUTOFF VALVE FOR EACH FIXTURE.
15. WHEREVER DISSIMILAR METALS ARE TO JOINED, A DIELECTRIC FITTING SHALL BE
PROVIDED TO CONNECT BOTH TYPES OF PIPES.
16. PLUMBING CONTRACTOR SHALL PROVIDE AIR CONDITIONING CONDENSATE DRAIN
AND TRAP, SEE AIR CONDITIONING PLANS FOR LOCATION OF UNITS AND DRAINS.
17. MATERIALS
A. DOMESTIC WATER PIPING
1. UNDERGROUND PIPING UPSTREAM OF WATER METER AND 47AND LARGER SHALL
BE PVC PLASTIC PIPE LISTED FOR UNDERGROUND DOMESTIC WATER USE.
UNDERGROUND PIPING 37AND SMALLER SHALL BE TYPE'L' HARD DRAWN
COPPER FINISHED WITH BITUMASTIC PAINT.
2. DOMESTIC WATER PIPING INSIDE OF BUILDING SHALL BE TYPE 'M'COPPER PIPE
AND FITTING.
3. AS AN ALTERNATE, THE PLUMBING CONTRACTOR MAY BID THIS PROJECT USING
BF GOODRICH CPVC PIPE FOR DOMESTIC HOT/COLD WATER WITHIN THE APARTMENTS AND
WHERE PERMITTED BY CODE.
B. SANITARY PIPING
1. SANITARY PIPING UNDERGROUND AND BEYOND FEET FROM THE BUILDING SHALL
BE SDR35 PVC PIPE.
2. SANITARY PIPING UNDER THE BUILDING SHALL BE SCHEDULE 40 PVC PIPE AND
FITTING.
3. SANITARY PIPING WITHIN THE BUILDING SHALL BE CENTRIFUGAL SPUN, HUBLESS,
SERVICE WEIGHT CAST IRON PIPE.
4. CONCEALED SANITARY PIPING ABOVE SLAB ( SINK AND LAVATORY TRAPS, ARMS)
SHALL BE DWV COPPER.
C. STORM WATER & SERVICE PIPING
1. STORM WATER PIPING UNDERGROUND AND UNDER THE BUILDING SHALL BE
SCHEDULE 40 PVC PIPE AND FITTING.
2. STORM WATER PIPING IN THE BUILDING SHALL BE CENTRIFUGAL SPUN, HUBLESS,
SERVICE WEIGHT CAST IRON PIPE.
3. CONDENSATE DRAIN PIPING SHALL BE INSULATED DWV COPPER ABOVE
GROUND (INCLUDING A/C CLOSETS) AND SCHEDULE 40 PVC UNDERGROUND.
4. WATER HEATER RELIEF VALVE AND DRAIN PAN PIPING SHALL BE TYPE'M'
COPPER.
U.S. FOUNDRY & MFG. CORP.
STEEL GERATE NO. 7100
I
AS REQUIRED
TRENCH DRAIN DETAIL
N.T.S.
SOUTH MIAMI APARTMENTS
DOMESTIC PUMP
SCHEDULE
ITEM
PUMP NUMBER P-1
P-2
P-3
F.U.
COUNT
APPLICATION TRI PLEX DOMESTIC BOOSTER SYS.
TRI-PLEX DOMESTIC BOOSTER SYS.
TRI-PLEX DOMESTIC BOOSTER SYS.
P
LOCATION REMOTE
1
�
BATHTUB
1/2-
REMOTE
REMOTE
U
G.P.M. 68
136
136
1/2-
T.D.H.(IN FT. WATER) 97
97
97
M
H.P. 3
5
5
4
R.P.M. 3500
3500
3500
P
MOUNTING 1 st FLOOR
1 st FLOOR
1 st FLOOR
DRINKING FOUNTAIN
VOLTAGE 208 VOLTS 0 60 CYCLES/3PH
208 VOLTS 0 60 CYCLES/3PH
208 VOLTS 0 60 CYCLES/3PH
1 2
MOTOR TYPE O.D.P
O.D.P
O.D.P
-
PUMP TYPE CLOSE COUPLED END SUCTION
CLOSE COUPLED END SUCTION
CLOSE COUPLED END SUCTION
DISHWASHER
MANUFACTURE GOULDS
GOULDS
GOULDS
S
MODEL
FLOOR DRAIN
-
-
3656
3656
3656
C
MANIFOLD SIZE 6 INCH
6 INCH
6 INCH
4
CONSTRUCTION BRONZE FITTED
BRONZE FITTED
BRONZE FITTED
H
SEAL MECHANICAL
MECHANICAL
MECHANICAL
OPERATING WEIGH - LBS
E
INERTIA BLOCK SIZE
D
ACESSORIES: U.L LISTED CONTROLLER WITH 100% 1 YEAR WARRANTY
TANK:119GALLONS 0125 P.S.I.
CIRCUIT BREAKER FOR EACH PUMP.
MOUNTING: 1st FLOOR
U
P.R VALVES (100% EPDXY COATED INSIDE AND OUTSIDE)
LOCATION: REMOTE
WITH STAINLESS STEEL MAIN SEATS.
ASM E: NO
L
LOW CITY PRESSURE
NO FLOW SYS. SHUT DOWN (NORMAL)
HYDRO -PNEUMATIC BLADDER TANK
E
FLANGED ISOLATORS (RUBBER SPHERE)
INERTIA BASE SPRINGS
TEMP. PURGE FOR EACH PUMP
HIGH SYS. PRESSURE CUT OUT
PROGRAMABLE PUMP SEQUENCE W/DIGITAL DISPLAY
24 HOUR EMERGENCY SERVICE FOR (1) YEAR ON SYSTEM
PROGRAMABLE CONTROLLER
ELAPSED TIME METER
AUDIBLE ALARM (WITH SILENCER)
DRY CONTACS-REMOTE ALARM
HIGH FLOW/PRESSURE SWITCH
1 2\
24" DIAMETER MANHOLE 90• DEGREE CLEAN
FRAME W/ SOLID LID- OUT/
HEAVY DUTY ��(TYP. 2) SAMPLING PORT
'TRAFFIC LID",,
DIA. VENT IN BAFFLE
-4 "CLEAN OUT 3"VENT CONN.
--4"CLEAN
OUT
6" .
MIN. M N. AX
WATER LINE 2'-0" TO VENT)
4"INLET BAFFLE MIN. 4"OUTLET LINE
NOTE: TOTAL CAPACITY SHALL
BE AS PER SECTION 4612.5
S.F.B.C.
15 MAX. OR VENTING
NEEDED AS PER S.F.B.C.
Q OIL INTERCEPTOR DETAIL
N.T.S
GENERAL PLUMBING NOTES
1. ALL WORK SHALL CONFORM WITH ALL LOCAL, STATE, FEDERAL ORDINANCES AND
BUILDING CODES GOVERNING THE INSTALLATION OF THE PLUMBING SYSTEM.
IF WORK AS LAID OUT, INDICATED OR SPECIFIED IS CONTRARY TO OR CONFLICTS
WITH LOCAL ORDINANCES, BUILDING CODES AND REGULATIONS, THE CONTRACTOR
SHALL REPORT IN WRITING TO THE ARCHITECT/ENGINEER BEFORE SUBMITTING A
BID. THE ARCHITECT/ENGINEER WILL THEN ISSUE INSTRUCTIONS AS HOW TO
PROCEED.
2. THE DRAWINGS ARE TO BE CONSIDERED DIAGRAMMATIC, NOT NECESSARILY
SHOWING IN DETAIL OR TO SCALE ALL OF THE MINOR ITEMS. UNLESS SPECIFIC
DIMENSIONS ARE SHOWN, THE STRUCTURAL, ARCHITECTURAL AND SITE CONDITIONS
SHALL GOVERN THE EXACT LOCATIONS. CONTRACTOR SHALL FOLLOW DRAWINGS IN
LAYING OUT WORK, CHECK DRAWINGS OF ALL TRADES TO VERIFY SPACES IN
WHICH WORK WILL BE INSTALLED AND MAINTAIN MAXIMUM HEAD ROOM, AND
SPACE CONDITIONS AT ALL POINTS. WHERE HEAD ROOM, OR SPACE CONDITIONS
APPEAR INADEQUATE, ARCHITECT/ENGINEER SHALL BE NOTIFIED BEFORE PROCEEDING
WITH INSTALLATION. THIS CONTRACTOR SHALL, WITHOUT EXTRA CHARGE, MAKE FIELD
MODIFICATIONS IN LAYOUT AS NEEDED TO PREVENT CONFLICT WITH WORK OF
VARIOUS TRADES OR FOR PROPER EXECUTION OF THE WORK.
3. EXAMINE ALL DRAWINGS CAREFULLY PRIOR TO SUBMITTING A BID. CONTRACTOR
WILL BE REQUIRED TO FURNISH, INSTALL AND/OR CONNECT WITH APPROPRIATE
SERVICES ALL PLUMBING ITEMS SHOWN ON ANY OF THE ARCHITECTURAL, AIR
CONDITIONING, ELECTRICAL AND SPRINKLER DRAWINGS WITHOUT ADDITIONAL EXPEN-
SE TO THE OWNER . IF DISCREPANCIES, CONFLICTS, INTERFERENCES OR OMISSIONS
OCCUR BETWEEN DRAWINGS, NOTIFY IN WRITING THE ARCHITECT/ENGINEER IN
AMPLE TIME TO PERMIT REVISIONS BEFORE THE BIDS ARE SUBMITTED.
4. INSTALL MATERIALS AND EQUIPMENT IN A NEAT AND FIRST CLASS WORKMANLIKE
MANNER. THE OWNER RESERVES THE RIGHT TO DIRECT REMOVAL AND
REPLACEMENT OF ITEMS OF WHICH, IN HIS OPINION, DO NOT PRESENT A
NEAT AND WORKMANLIKE APPEARANCE. REMOVAL AND REPLACEMENT IS TO BE
DONE IMMEDIATELY WHEN DIRECTED BY THE OWNER IN WRITING, AT THE SOLE
EXPENSE OF THE CONTRACTOR.
5. START OF WORK BY CONTRACTOR SHALL BE CONSIDERED AS ACCEPTANCE
BY HIM OF ALL CLAIMS OR QUESTIONS AS TO SUITABILITY OF THE WORK OF
OTHER TRADES OR OTHER CONTRACTORS TO RECEIVE HIS WORK. THIS CONTRACT -
TOR SHALL REMOVE AND REPLACE, AT HIS EXPENSE, ALL PLUMBING WORK WHICH
MAY HAVE TO BE REMOVED BECAUSE OF INTERFERENCES WITH OTHER TRADES.
6. THIS CONTRACTOR SHALL OBTAIN AND PAY ALL INSURANCE, FEES, PERMITS
ASSOCIATION DUES, ROYALTIES, AND TAXES OF WHATEVER NATURE SHALL APPLY
TO THIS WORK. HE SHALL ALSO PAY ALL INSPECTION FEES AS MAY BE REQUIRED
BY LAW OR ORDINANCE AND SHALL KEEP THE OWNER HARMLESS FROM ANY
DAMAGE AND EXPENSE ARISING FROM ANY VIOLATION OF THE LAWS, RULES OR
ORDINANCES.
7. PROVIDE MEANS "FURNISHED AND INSTALL".
8. DO A COMPLETE JOB, EVERYTHING CONNECTED, READY FOR USE.
9. SHOP DRAWINGS: THIS CONTRACTOR SHALL FURNISH THE ENGINEER WITH SHOP
DRAWINGS OF EQUIPMENT PRIOR TO PURCHASE FOR APPROVAL
10. AT COMPLETION OF JOB THE PLUMBING CONTRACTOR SHALL GIVE THE
OWNER AN AS -BUILT SET OF REPRODUCIBLE SEPIAS SHOWING THE EXACT
INSTALLATION.
11. PLUMBING CONTRACTOR SHALL PRESSURE TEST ALL PIPING AS REQUIRED BY
CODE. TEST SHALL BE WITNESSED AND APPROVED BY PROPER AUTHORITIES.
12. THE PLUMBING CONTRACTOR SHALL WARRANT ALL WORKMANSHIP AND MATERIALS
FOR ONE YEAR FROM THE DATE OF FINAL WORK ACCEPTANCE BY OWNER. ANY
BREAKDOWN OCCURRING IN FIRST YEAR SHALL BE REPAIRED AT NO EXPENSE TO
THE OWNER.
13. PLUMBING FIXTURES SHALL BE PROVIDED BY THE OWNER AND SHALL BE HANDLED /
INSTALLED BY THE PLUMBING CONTRACTOR. PLUMBING FIXTURE RELATED SUPPLIES (P -TRAPS,
ETC.) ARE NOT PART OF THE FIXTURE PLUMBING PACKAGE ALLOWANCE AND SHALL BE
PROVIDED BY THE PLUMBING CONTRACTOR. WATER HEATERS ARE NOT PART OF THE PLUMBING
FIXTURE PACKAGE AND SHALL BE PROVIDED BY THE PLUMBING CONTRACTOR.
14. PROVIDE SHUTOFF VALVE FOR EACH FIXTURE.
15. WHEREVER DISSIMILAR METALS ARE TO JOINED, A DIELECTRIC FITTING SHALL BE
PROVIDED TO CONNECT BOTH TYPES OF PIPES.
16. PLUMBING CONTRACTOR SHALL PROVIDE AIR CONDITIONING CONDENSATE DRAIN
AND TRAP, SEE AIR CONDITIONING PLANS FOR LOCATION OF UNITS AND DRAINS.
17. MATERIALS
A. DOMESTIC WATER PIPING
1. UNDERGROUND PIPING UPSTREAM OF WATER METER AND 47AND LARGER SHALL
BE PVC PLASTIC PIPE LISTED FOR UNDERGROUND DOMESTIC WATER USE.
UNDERGROUND PIPING 37AND SMALLER SHALL BE TYPE'L' HARD DRAWN
COPPER FINISHED WITH BITUMASTIC PAINT.
2. DOMESTIC WATER PIPING INSIDE OF BUILDING SHALL BE TYPE 'M'COPPER PIPE
AND FITTING.
3. AS AN ALTERNATE, THE PLUMBING CONTRACTOR MAY BID THIS PROJECT USING
BF GOODRICH CPVC PIPE FOR DOMESTIC HOT/COLD WATER WITHIN THE APARTMENTS AND
WHERE PERMITTED BY CODE.
B. SANITARY PIPING
1. SANITARY PIPING UNDERGROUND AND BEYOND FEET FROM THE BUILDING SHALL
BE SDR35 PVC PIPE.
2. SANITARY PIPING UNDER THE BUILDING SHALL BE SCHEDULE 40 PVC PIPE AND
FITTING.
3. SANITARY PIPING WITHIN THE BUILDING SHALL BE CENTRIFUGAL SPUN, HUBLESS,
SERVICE WEIGHT CAST IRON PIPE.
4. CONCEALED SANITARY PIPING ABOVE SLAB ( SINK AND LAVATORY TRAPS, ARMS)
SHALL BE DWV COPPER.
C. STORM WATER & SERVICE PIPING
1. STORM WATER PIPING UNDERGROUND AND UNDER THE BUILDING SHALL BE
SCHEDULE 40 PVC PIPE AND FITTING.
2. STORM WATER PIPING IN THE BUILDING SHALL BE CENTRIFUGAL SPUN, HUBLESS,
SERVICE WEIGHT CAST IRON PIPE.
3. CONDENSATE DRAIN PIPING SHALL BE INSULATED DWV COPPER ABOVE
GROUND (INCLUDING A/C CLOSETS) AND SCHEDULE 40 PVC UNDERGROUND.
4. WATER HEATER RELIEF VALVE AND DRAIN PAN PIPING SHALL BE TYPE'M'
COPPER.
U.S. FOUNDRY & MFG. CORP.
STEEL GERATE NO. 7100
I
AS REQUIRED
TRENCH DRAIN DETAIL
N.T.S.
U.S. FOUNDRY & MFG. CORP.
GRATE NO. 6145 -7
4"x4" 10/10 - 311
WIRE MESH THOUGHOUT
ALBERT SHUB
PE# 0043414 M.E.
EB0003862
FLORIDA ENGINEERING SERVICES
MECHANICAL AND ELECTRICAL
ENGINEERS
Fk b
�� 1` •
U 1 •�4 N.W. 168TH STREET
r'�L'' *,',-NORTH MIAMI BEACH, FL. 33169
"TELEPHONE: 305 653-0212
FAX: (305) 653-0232
REVISIONS
02-28-02
9-02
A BLIIJG. 2DEPT./CORD.
V J
FIXTURE
CONNECTION
SCHEDULE
ITEM
C.W.
CONN
H.W.
CONN
TRAP
SIZE
F.U.
COUNT
REMARKS
LAVATORY
1/2-
1/2-
1 1/4-
1
�
BATHTUB
1/2-
1/2-
1 1/2-
2
Q.
SHOWER
1/2"
1/2-
2"
2
WATER CLOSET TANK
1/2N
-
3"
4
Q
KITCHEN SINK
1/2"
1/2-
1 1 2"
2
DRINKING FOUNTAIN
1/2-
-
1 1,
1 2
SEE PLANS FOR LOCATIONS
HOSE BIB
1/2"
-
-
-
VACUUM BREAKER & VALVE
IN THE VERTICAL
DISHWASHER
-
1 2"
1 1/2-
2
�O
V )
FLOOR DRAIN
-
-
3"or 4"
3 1
PROVIDE TRAP RESEALER
WASHING MACHINE
3 4"
-
2"
4
U.S. FOUNDRY & MFG. CORP.
GRATE NO. 6145 -7
4"x4" 10/10 - 311
WIRE MESH THOUGHOUT
ALBERT SHUB
PE# 0043414 M.E.
EB0003862
FLORIDA ENGINEERING SERVICES
MECHANICAL AND ELECTRICAL
ENGINEERS
Fk b
�� 1` •
U 1 •�4 N.W. 168TH STREET
r'�L'' *,',-NORTH MIAMI BEACH, FL. 33169
"TELEPHONE: 305 653-0212
FAX: (305) 653-0232
REVISIONS
02-28-02
9-02
A BLIIJG. 2DEPT./CORD.
V J
z
W
�
W
�
Q.
0
O
Q IL
O>
LU
w�
S
LL
�
UQC
Q
L
I-
1
Q
LU
I
O
D
�O
V )
Im
DRAWN
CHECK D
DATE 02-28-02
SCALE
JOB NO. 02013
SHEET
P -14
OF SHEETS