02-509-15550 I PAC No.4 ROOF = C C C C 6TH FL, C C C C 5TH FL, C C C C 4TH FL. C C C C 3RD FL. C C C C 2ND FL. 1 ST FL ROOF TYPICAL CONNECTION FOR ALL UNITS 3#4 & 1#8 (GND) CU 1 -1/4 - PHOTOCELL 3#3/0 & 1#10 GND 2" (2)SETS OF 3#3/0 & 1#3/0 2" EACH SET TO MAIN CKT. BKR. No. 2 AT METER ROOM No.3 SERVICE ENTRANCE RATED FIRE PUMP CONTROLLER METER CENTER 4 TO MAIN CKT. BKR. No.6 AT METER ROOM No.3 A A C2 C2 A A E E C C 6TH FL. A 5TH FL. A 4TH FL. A 3RD FL. A 2ND FL. 1 ST FL A C2 C2 A A E E C C A C2 C2 A A E E C C A C2 C2 A A E E C C A C2 C2 A A E E C C TYPICAL CONNECTION FOR ALL UNITS A2PARTIAL "C" ELECTRICAL RISER DIAGRANkv.T.S - - (ELECTRICAL ROOM No.3 PAC 0 No.5 MAIN No. 6 OF 6 ■ 0 O TAP 'v' Box • O .n. DOM. WTR. PUMP FIRE PUMP TO MDP (3)SETS OF 3#600 MCM & 1#4/0 THWN ALUM & 1#2/0 CU GND 4" PVC EACH SET 3#6 & 1#10 THHN CU GND 1" PVC PAC 0 I No.3 3#6 & 1#8 (GND) CU 1" C/T CABINET CALCULATION LOAD DESCRIPTION LOAD AMPS L1 L2 L3 NEUT (2)60HP HYDRAULIC ELEV. 354 354 354 0 PANEL HC 440 440 440 133 PANEL HG 313 313 313 178 TOTAL LOAD AMPS 1107 1107 1107 311 MAIN No. 5 OF 6 ODI0 n C/T ■ ■ ■ ■ L HM HL HC MAIN MAIN MAIN No.4 No.3 No.2 ss OF 6 OF 6 OF 6 ® ss ss ss PHOTOCELL (2)SETS OF 3#500 MCM THWN ALUM. & 1 #350 MCM THWN CU 4" PVC EACH SET OR (2)SETS OF 4#350 MCM THWN CU 4" PVC EACH SET ELEC. CALCULATIONS FOR METER CENTER 4 RM #4 37 APARTMENTS ( 5-13,32—C UNITS) JOCKEY PUMP RETAIL STORE —TO PAD MTD. TRANSFORMER TfP. OF 7 3#400 MCM THWN ALUM. & 1#2 THWN CU 4" PVC OR 3#300 MCM THWN CU & 1#2 THWN CU 4" PVC 3#12 & 1#12 THHN CU GND 1/2" PVC 3#1 & 1#6 (GND) CU 1-1/2" MAIN No. 1 ■ OF 6 F ■ ■ MDP (2)SETS OF 3#3/0 & 1 #3/0 2" EACH SET TO PANEL "HG" AT ELECTRICAL ROOM No.4 ELEC. NEUTRAL CALCULATIONS FOR METER CENTER RM #4 37 APARTMENTS KW RANGES 296 AIR CONDITIONING 191 DRYERS 185 WATER HEATERS 167 DISHWASHERS 44 GARBAGE DISPOSALS 26 REFRIGERATORS 26 WASHERS 56 SMALL APPLIANCES 111 LIGHT & RECEPTACLES 105 TOTAL WITHOUT DEMAND 1207 NEC TABLE 220-32 FURTHER DEMAND NEC 220-22 1207 x 29% x 1000= 972 AMPS 360 NEXT 486 ® 70% JOCKEY PUMP RETAIL STORE —TO PAD MTD. TRANSFORMER TfP. OF 7 3#400 MCM THWN ALUM. & 1#2 THWN CU 4" PVC OR 3#300 MCM THWN CU & 1#2 THWN CU 4" PVC 3#12 & 1#12 THHN CU GND 1/2" PVC 3#1 & 1#6 (GND) CU 1-1/2" MAIN No. 1 ■ OF 6 F ■ ■ MDP (2)SETS OF 3#3/0 & 1 #3/0 2" EACH SET TO PANEL "HG" AT ELECTRICAL ROOM No.4 ELEC. NEUTRAL CALCULATIONS FOR METER CENTER RM #4 37 APARTMENTS BY LTS & RECEPT., SMALL APPL, WASHER (272 KW) RANGES 240 JKW 3 KW ® 100% 3 NEXT 117 KW ® 35% 41 NEXT 152 KW ® 25% 38 REFRIG.,DISHWASHER, GARBAGE DISPOSALS GARB. DISP. ® 100% 96 RANGES: 15 + 37 x 70% 36 DRYERS: 47.17 x 70% 33 TOTAL KW 247 247,000 +360 = 686 AMPS TOTAL WITHOUT DEMAND FURTHER DEMAND NEC 220-22 NEC TABLE 220-32 1st 200 AMPS ® 100% 200 NEXT 486 ® 70% 340 TOTAL AMPS NEUTRAL 540 ELEC. NEUTRAL CALCULATIONS RM #3 FOR METER CENTER 35 APARTMENTS BY LTS & RECEPT., SMALL APPL, WASHER (227KW) RANGES 240 xw 3 KW ® 100% 3 NEXT 117 KW ® 35% 41 NEXT 107 KW ® 25% 27 REFRIG.,DISHWASHER, GARBAGE DISPOSALS GARB. DISP. ® 100% 92 RANGES: 15 + 35 x 70% 35 DRYERS: 44.6 x 70% 31 TOTAL KW 229 229,000 +360 = 636 AMPS TOTAL WITHOUT DEMAND FURTHER DEMAND NEC 220-22 NEC TABLE 220-32 1st 200 AMPS ® 100% 200 NEXT 436 ® 70% 305 TOTAL AMPS NEUTRAL 540 ELEC. CALCULATIONS FOR RM #3 METER CENTER 1 30 APARTMENTS ( 5—A,5—B,15—C,5—E UNITS) BY RM #3 METER CENTER 3 KW RANGES 240 AIR CONDITIONING 141 DRYERS 150 WATER HEATERS 120 DISHWASHERS 36 GARBAGE DISPOSALS 21 REFRIGERATORS 21 WASHERS 45 SMALL APPLIANCES 90 LIGHT & RECEPTACLES 73 TOTAL WITHOUT DEMAND 937 NEC TABLE 220-32 108 937 x 33% x 1000 = 858 AMPS 360 TOTAL WITHOUT DEMAND ELEC. CALCULATIONS FOR BY RM #3 METER CENTER 3 1 36 APARTMENTS 2 ( 1—A,12—B,12—C,11—E UNITS) 400A, 3P, 208V, DISC. SW., W/RK5 350A FUSES INSIDE ELEV. MACH. RM. KW RANGES 288 AIR CONDITIONING 161 DRYERS 180 WATER HEATERS 144 DISHWASHERS 43 GARBAGE DISPOSALS 25 REFRIGERATORS 25 WASHERS 54 SMALL APPLIANCES 108 LIGHT & RECEPTACLES 82 TOTAL WITHOUT DEMAND 1110 NEC TABLE 220-32 O 1110 x 30% x 1000 = 925 AMPS 360 .O 2" EMPTY PVC Q PARTIAL "D" ELECTRICAL RISER DIAGRAK.T.S ELECTRICAL ROOM No.4 ELECTRICAL RISER DIAGRAM EQUIPMENT SCHEDULE (ALL EQUIPMENT TO BE SIEMENS OR EQUAL) BY DESCRIPTION 1 HOUSE METER, PROVIDE AUXILIARY LUGS 2 400A, 3P, 208V, SHUNT TRIP OPERATED. ELEVATOR MAIN CKT. BKR. 42KAIC 3 400A, 3P, 208V, DISC. SW., W/RK5 350A FUSES INSIDE ELEV. MACH. RM. 4 SURGE PROTECTION 5 200A, 208V, NEMA 3R, NF DISCONNECT SWITCH 6 SPST TIME SW. FOR CKT. HC2 7 1000A, 3P, 120/208V, TAP BOX 8 METER CENTER WMM64U W/100A, 2P, 22 KAIC, BRANCH BKRS. FOR TYPE A & E UNITS 9 METER CENTER WMM64U W/125A, 2P, 22 KAIC, BRANCH BKRS. 10 SPST TIME SW. CONNECTED TO LIGHTING CONTACTOR AND PHOTOCELL 11 6PST LIGHTING CONTACTOR CONNECTED TO TIME SWITCH AND PHOTOCELL FOR CKTS. HD5/7, HD9/11, HD13 & HD15 (3)SETS OF 3#600 MCM & 1 #4/0 THHN ALUM. 3-1/2" EACH SET (4)SETS OF 3#500 MCM THWN ALUM. & 1#4/0 THWN CU 4" PVC EACH SET OR (3)SETS OF 3#600 MCM THWN CU & 1#4/0 THWN CU 4" PVC EACH SET ELEV. MACH. ROOM ;;P Fa) ELEC. NEUTRAL CALCULATIONS FOR METER CENTER RM #3 30 APARTMENTS BY METER CENTER 2 (208KW) METER CENTER 1 0 JS17L 3 KW ® 100% 3 NEXT 117 KW ® 35% 41 0..0. 0. 0.0.O0 TAP TAP •0..0OO..0 •0.O • 0-0-0-0-0-0- •0.0.0.0• TAP METER 0.0.0.0.0.0• BOX BOX •O.O.O •0.O 0.0-6-0-0-0- BOX CENTER 3 0.0.0.0.0.0• WASHERS 0 . 0 . 0 •5.0 • 0.0.0.0.0.0- •0.0.0.0•O •• O.0 •O. O O.O. .O.O• 360 .O OO.O•O • - do"jo.•OO •O.O..• 00 -O 0 0. •O.O.•.O.O.100" :15 c -T - w - G cr � 088888 Z 88888 0 00 00000 TO METER CENTER AT ELECTRICAL ROOM No.4 (3)SETS OF 3#600 MCM & 1#4/0 THWN ALUM & 1#2/0 CU GND 4" PVC EACH SET (4)SETS OF 3#500 MCM THWN ALUM. & 1#4/0 THWN CU 4" PVC EACH SET OR (3)SETS OF 3#600 MCM THWN CU & 1#4/0 THWN CU 4" PVC EACH SET ELEV. MACH. ROOM ;;P Fa) ELEC. NEUTRAL CALCULATIONS FOR METER CENTER RM #3 30 APARTMENTS BY LTS & RECEPT., SMALL APPL, WASHER (208KW) 35 APARTMENTS JS17L 3 KW ® 100% 3 NEXT 117 KW ® 35% 41 NEXT 88 KW ® 25% 22 REFRIG.,DISHWASHER, DRYERS GARB. DISP. ® 100% 78 RANGES: 15 + 30 x 70% 31 DRYERS: 39 x 70% 27 TOTAL KW 202 202,000 + 360 = 561 AMPS WASHERS FURTHER DEMAND NEC 220-22 SMALL APPLIANCES 1st 200 AMPS ® 100% 200 NEXT 361 ® 70% 253 TOTAL AMPS NEUTRAL 453 ELEC. NEUTRAL CALCULATIONS FOR METER CENTER RM #3 36 APARTMENTS BY LTS & RECEPT., SMALL APPL., WASHER (244KW) 35 APARTMENTS xw 3 KW ® 100% 3 NEXT 117 KW ® 35% 41 NEXT 124 KW ® 25% 31 REFRIG.,DISHWASHER, DRYERS GARB. DISP. ® 100% 93 RANGES: 15 + 35 x 70% 35 DRYERS: 46 x 70% 32 TOTAL KW 235 235,000 + 360 = 653 AMPS WASHERS FURTHER DEMAND NEC 220-22 SMALL APPLIANCES 1 st 200 AMPS ® 100% 200 NEXT 453 ® 70% 317 TOTAL AMPS NEUTRAL 517 EC. CALCULATIONS FOR ELECRM . BY METER CENTER 2 35 APARTMENTS ( 22—A,1—C,11—C2,1—E UNITS) 07-29-02 KW RANGES 280 AIR CONDITIONING 150 DRYERS 175 WATER HEATERS 107 DISHWASHERS 42 GARBAGE DISPOSALS 25 REFRIGERATORS 25 WASHERS 53 SMALL APPLIANCES 105 LIGHT & RECEPTACLES 69 TOTAL WITHOUT DEMAND 1031 NEC TABLE 220-32 1031 x 30% x 1000 = 859 AMPS 360 B B C C A C B E B B C C A C B E B B C C A C B E B B C C A C B E B B C C A E 120/208, 3P PAD MOUNTED TRANSFORMER BY POWER COMPANY 3#4/0 & 1#3 GND CU 2" PVC (8)SETS OF 3#600 MCM THWN ALUM. & REVISIONS BY 02-28-02 ISSUE FOR PERMIT 07-29-02 2 BLDG. DEPT. CORD. VJ Z W Ld l '••� C 0 _ a. - L] 0W w= - �� _Q� Q - -O :15 c -T - w - G cr � - Z vJ 1 #4/0 THWN CU 4" PVC EACH SET OR DRAWN (6)SETS OF 3#600 MCM THWN CU & CHECKED 1 #4/0 THWN CU 4" PVC DATE 02-28-02 ERNESTO R. TORRES SCALE PE# 0049958 E.E. JOB NO. 02013 EB0003862 SHEET FLORIDA ENGINEERING SERVICES MECHANICAL AND ELECTRICAL (2)SETS OF 3#500 MCM THWN ALUM. & ENGINEERS 1 #350 MCM THWN CU 4" PVC EACH ,.SE'J,' .' OR (2)SETS OF 4#350 MCM PVC EACH SET • 'i' �' `� ; � '• 34 N.W. 168TH STREET =�', '• =NORTH MIAMI BEACH, FL 33169 • : TELEPHONE: (305) 653-0212 •'� ' FAX: (305) 653-0232 O F SHEETS