Loading...
02-509-154IPAC No.2 ROOF C C C C E B C A D D H C D D 6TH FL. 3#1 & 1#6 (GND) C C C C E B C CU 1-1/2" A D D E C D D 5TH FL C C C C E B C A D D E C D D 4TH FL C C C C E B C A D D H C D D 3RD FL. 3#4/0 & C C C C E B C 1#3 2" A D D C1 C D D TO ELEV. 4#6 1-1 /4" 2ND FL. CONTROLLER D F EXACT LOCATION TO ® BE FIELD DETERMINED O ss 0 ss ® 888 ss0000 C C C C E B C C ® ■ O HB HP 0.0.0• •0.0.0.0 0.0.0.(M.0.0.0 .0 A D D H C D D MAIN 0.0.0• •0.0.0.0 0.0.0- •0.0.0.0 No.4 MAIN MAIN MAIN ELEV. No.3 O.O.O• No.2 '0.0.0.0 O.O.O• No.1 '0.0.0.0 MACH. 0.0.0• -0 0.0.0.0 ROOM 0.0.0• •0.0.0.0 .O.O• .0.0.0 (3)SETS OF 3#600 MCM TYPICAL CONNECTION O.O.O• •0.0. . O .O.O• •O.O.O.O3#4/0 & 1 #3 OO & 1#4/0 THHN ALUM FOR ALL UNITS GND CU 2" 4" PVC EACH SET 1ST FL. 1 00 0000 PAC No.1 ROOF 0Ir PARTIAL "B" ELECTRICAL RISER DIAGRAMN.T.S (ELECTRICAL ROOM No.2 C C B E C A D D C C A A 6TH FL. 3#1 & 1#6 (GND) C C B E cu 1-1/2" C A D D C C A A 5TH FL. C C B E C A D D C C A A 4TH FL. C C B E C A D D C C A A 3RD FL. 3#4/0 & 1 #3 (GND) CU 2" C C B E C A D D C C A A TO ELEV. 3#4/0 & 2ND FL. CONTROLLER 1#3 CU 2" ss GD 0 O 00000 00 0 000 ss ■ ■ ■ C C B E c 0.0.0.0.0.0• 0.O •0.0.0.0 C3 A D D C C A A ® MAIN O MAIN LNo. IN No.3 HA O. O. O. O.O. O• No.2 1 •O.O •0.0.0.0 OF4 0 0. 0.0.0.0.0.OF4 4.0.0 •0.0.0.0 ELEV. 02 MAIN O. O. O. O.O.O• •O.O •0.0.0.0 MACH. No.4 O.O.O.O.O.O• OO •O.O •0.0.0.0 ROOM 3#4/0 & OF 4 O. O. O. O. O. O • • O.O •0 •0.0 •O (3)SETS OF 3#600 MCM TYPICAL CONNECTION 1 #2 CU 3" & 1 #4/0 THHN ALUM FOR ALL UNITS ® 4" PVC EACH SET 1 ST FL. A2 PARTIAL "A" ELECTRICAL RISER DIAGRAMN.T.S (ELECTRICAL ROOM No.1 ELEC. CALCULATIONS FOR METER CENTER RM #1 36 APARTMENTS ELECTRICAL RISER DIAGRAM EQUIPMENT SCHEDULE ELEC. RM. No.2 (ALL EQUIPMENT TO BE SIEMENS OR EQUAL) LOAD DESCRIPTION DESCRIPTION L7 1 HOUSE METER, PROVIDE AUXILIARY LUGS NEUT 2 400A, 3P, 208V, SHUNT TRIP OPERATED, ELEVATOR MAIN BKR. 42KAIC CKT. 3 400A, 3P, 208V, DISC. SW., W/RK5 350A FUSES INSIDE MACH. RM. ELEV. 4 SURGE PROTECTION 193 5 200A, 208V, NEMA 3R, NF DISCONNECT SWITCH 370 6 3PST TIME SW. FOR CKT. HB37, HB18 & HB20 59 7 1200A, 3P, 120/208V, 65 KAIC CKT. BKR. MC104U NEC TABLE 220-32 8 METER CENTER WMM64U W/100A, 2P, 22 KAIC, BRANCH FOR TYPE A & E UNITS BKRS. 9 METER CENTER WMM64U W/125A, 2P, 22 KAIC, BRANCH BKRS. HOUSE METER CALCULATION LOAD DESCRIPTION LOAD AMPS L7 TL2 L3 NEUT 60HP HYDRAULIC ELEV. 177 177 177 0 PANEL HB 193 193 193 59 TOTAL LOAD AMPS 370 370 370 59 120/208, 3P PAD MOUNTED TRANSFORMER BY POWER COMPANY (2)SETS OF 3#350 MCM & 1#1/0 THHN ALUM 3-1/2" PVC EACH SET 120/208, 3P PAD MOUNTED TRANSFORMER BY POWER COMPANY (2)SETS OF 3#300 MCM & 1#1/0 THHN ALUM 3-1/2" PVC EACH SET NEUTRAL CALCULATIONS KW RANGES 288 AIR CONDITIONING 167 DRYERS 180 WATER HEATERS 144 DISHWASHERS 43 GARBAGE DISPOSALS 25 REFRIGERATORS 25 WASHERS 54 SMALL APPLIANCES 108 LIGHT & RECEPTACLES 87 TOTAL WITHOUT DEMAND 1121 NEC TABLE 220-32 DRYERS: 49.5 x 70% 1121x 30% x 1000 _ — 934 AMPS 360 240,000 + 360 = 667 AMPS 120/208, 3P PAD MOUNTED TRANSFORMER BY POWER COMPANY (2)SETS OF 3#300 MCM & 1#1/0 THHN ALUM 3-1/2" PVC EACH SET NEUTRAL CALCULATIONS KW ELEC. FOR METER CENTER 336 RM #1 36 APARTMENTS 240 DRYERS 210 LTS & RECEPT., SMALL APPL., WASHER (249KW) DISHWASHERS 50 KW 3 KW ® 100% 3 NEXT 117 KW ® 35% 41 NEXT 129 KW ® 25% 32 REFRIG.,DISHWASHER, LIGHT & RECEPTACLES GARB. DISP. ® 100% 93 RANGES: 15 + 36 x 70% 36 DRYERS: 49.5 x 70% 35 TOTAL KW 240 240,000 + 360 = 667 AMPS BKRS. FURTHER DEMAND NEC 220-22 1st 200 AMPS ® 100% 200 NEXT 467 ® 70% 327 TOTAL AMPS NEUTRAL 527 EC. CALCULATIONS FOR ELEC. #2 METER CENTER 42 APARTMENTS ELEC. NEUTRAL CALCULATIONS KW RANGES 336 AIR CONDITIONING 240 DRYERS 210 WATER HEATERS 216 DISHWASHERS 50 GARBAGE DISPOSALS 29 REFRIGERATORS 29 WASHERS 63 SMALL APPLIANCES 126 LIGHT & RECEPTACLES 128 TOTAL WITHOUT DEMAND 1427 NEC TABLE 220-32 DRYERS: 52.5 x 70% 1427 x28% x 1000 = 1110 AMPS 360 278,000 + 360 = 772 AMPS ELEC. NEUTRAL CALCULATIONS O RM #2 FOR METER CENTER L1 42 APARTMENTS HOUSE METER, PROVIDE AUXILIARY LUGS NEUT 2 LTS & RECEPT., SMALL APPL., WASHER (317KW) 3 400A, 3P, 208V, DISC. SW., W/RK5 350A FUSES INSIDE MACH. RM. JKW 3 KW ® 100% 3 NEXT 117 KW ® 35% 41 NEXT 197 KW ® 25% 49 REFRIG.,DISHWASHER, 3PST TIME SW. FOR CKT. HA25, HA24 & HA26 GARB. DISP. ® 100% 108 RANGES: 25 + 31.5 x 707. 40 DRYERS: 52.5 x 70% 37 TOTAL KW 278 278,000 + 360 = 772 AMPS BKRS. FURTHER DEMAND NEC 220-22 1st 200 AMPS ® 100% 200 NEXT 572 ® 70% 400 TOTAL AMPS NEUTRAL 600 ELECTRICAL RISER DIAGRAM EQUIPMENT SCHEDULE ELEC. RM. No.1 (ALL EQUIPMENT TO BE SIEMENS OR EQUAL) O DESCRIPTION L1 1 HOUSE METER, PROVIDE AUXILIARY LUGS NEUT 2 400A, 3P, 208V, SHUNT TRIP OPERATED, ELEVATOR MAIN BKR. 42KAIC CKT. 3 400A, 3P, 208V, DISC. SW., W/RK5 350A FUSES INSIDE MACH. RM. ELEV. 4 SURGE PROTECTION 185 5 200A, 208V, NEMA 3R, NF DISCONNECT SWITCH 362 6 3PST TIME SW. FOR CKT. HA25, HA24 & HA26 66 7 1000A, 3P, 120/208V, 65 KAIC CKT. BKR. MC104U 8 METER CENTER WMM64U W/100A, 2P, 22 KAIC, BRANCH FOR TYPE A & E UNITS BKRS. 9 METER CENTER WMM64U W/125A, 2P, 22 KAIC, BRANCH BKRS. HOUSE METER CALCULATION LOAD DESCRIPTION LOAD AMPS L1 L2 L3 NEUT 60HP HYDRAULIC ELEV. 177 177 177 0 PANEL HA 185 185 185 66 TOTAL LOAD AMPS 362 362 362 66 REVISIONS BY 02-28-02 ISSUE FOR PERMIT 07-29-02 2 BLDG. DEPT. CORD. VJ Z I..L [L-, 0 ----- ^�_ : 0 Q LL ---- 0WLL _W _ ---- w U Q w 00- Z cl) ♦O VJ D RAW N CHECKED DATE 02-28-02 ERNESTO R. TORRES SCALE PE# 0049958 E.E. JOB NO. 02013 EB0003862 SHEET FLORIDA ENGINEERING SERVICES MECHANICAL AND ELECTRICAL ENGINEERS w;17'�; .FES E-26 `34 N.W. 168TH STREET NORTH MIAMI BEACH, FL. 33169 TELEPHONE: (305) 653-0212 FAX: (305) 653-0232 OF SHEETS