02-509-151GENERAL ELECTRICAL NOTES 1. ALL WORK SHALL CONFORM WITH ALL LOCAL, STATE, FEDERAL ORDINANCES AND BUILDING CODES GOVERNING THE INSTALLATION OF THE ELECTRICAL SYSTEM. IF WORK AS LAID OUT, INDICATED OR SPECIFIED IS CONTRARY TO OR CONFLICTS WITH LOCAL ORDINANCES, BUILDING CODES AND REGULA- TIONS, THE CONTRACTOR SHALL REPORT IN WRITING TO THE ARCHITECT/ ENGINEER BEFORE SUBMITTING A BID. THE ARCHITECT/ENGINEER WILL THEN ISSUE INSTRUCTIONS AS HOW TO PROCEED. 2. THE DRAWING ARE TO BE CONSIDERED DIAGRAMMATIC, NOT NECESSARILY SHOWING IN DETAIL OR TO SCALE ALL OF THE MINOR ITEMS. UNLESS SPECIFIC DIMENSIONS ARE SHOWN, THE STRUCTURAL, ARCHITECTURAL AND SITE CONDITIONS SHALL GOVERN THE EXACT LOCATIONS. CONTRACTOR SHALL FOLLOW DRAWINGS IN LAYING OUT WORK, CHECK DRAWINGS OF ALL TRADES TO VERIFY SPACES IN WHICH WORK WILL BE INSTALLED AND MAINTAIN MAXIMUM HEAD ROOM, OR SPACE CONDITIONS AT ALL POINTS. WHERE HEAD ROOM, OR SPACE CONDITIONS APPEAR INADEQUATE, ARCHITECT/ENGINEER SHALL BE NOTIFIED BEFORE PROCEEDING WITH INSTALLATION. THIS CONTRAC- TOR SHALL, WITHOUT EXTRA CHARGE, MAKE FIELD MODIFICATION IN LAYOUT AS NEEDED TO PREVENT CONFLICT WITH WORK OF VARIOUS TRADES OR FOR PROPER EXECUTION OF THE WORK. 3. EXAMINE ALL DRAWINGS CAREFULLY PRIOR TO SUBMITTING A BID. CONTRACTOR WILL BE REQUIRED TO FURNISH, INSTALL AND/OR CONNECT WITH APPROPRIATE SERVICES ALL ELECTRICAL ITEMS SHOWN ON ANY OF THE ARCHITECTURAL, PLUMBING, AIR CONDITIONING, SPRINKLER, DRAWINGS WITHOUT ADDITIONAL EXPENSE TO THE OWNER. IF DISCREPANCIES, CONFLICTS, INTERFERENCES OR OMISSIONS OCCUR BETWEEN DRAWINGS, NOTIFY IN WRITING THE ARCHITECT/ ENGINEER IN AMPLE TIME TO PERMIT REVISIONS BEFORE THE BIDS ARE SUBMITTED. 4. VERIFY SERVICE CHARACTERISTICS, LOCATION AND CONNECTION WITH TELEPHONE AND ELECTRIC UTILITY COMPANIES PERFORM ALL WORK RELATED TO SERVICE IN STRICT ACCORDANCE WITH UTILITY Co. STANDARDS AND REQUIREMENTS. 5. INSTALL MATERIALS AND EQUIPMENT IN A NEAT AND FIRST CLASS WORKMANLIKE MANNER. THE OWNER RESERVES THE RIGHT TO DIRECT REMOVAL AND REPLACE- MENT OF ITEM WHICH, IN HIS OPINION, DO NOT PRESENT A NEAT AND WORKMAN- LIKE APPEARANCE. REMOVAL AND REPLACEMENT IS TO BE DONE IMMEDIATELY WHEN DIRECTED BY THE OWNER IN WRITING, AT THE SOLE EXPENSE OF CONTRAC- TOR. ROOF 6. START OF WORK BY CONTRACTOR SHALL BE CONSIDERED AS ACCEPTANCE BY HIM OF ALL CLAIMS OR QUESTIONS AS TO SUITABILITY OF THE WORK OF OTHER TRADES OR OTHER CONTRACTORS TO RECEIVE HIS WORK. THIS CONTRACTOR SHALL REMOVE AND REPLACE, AT HIS EXPENSE, ALL ELECTRICAL WORK WHICH MAY HAVE TO BE REMOVED BECAUSE OF INTERFERENCE WITH OTHER TRADES. 7. THIS CONTRACTOR SHALL OBTAIN AND PAY ALL INSURANCE, FEES, PERMITS ASSO- CIATION DUES, ROYALTIES, AND TAXES OF WHATEVER NATURE SHALL APPLY TO THIS WORK. HE SHALL ALSO PAY ALL INSPECTION FEES AS MAY BE REQUIRED BY LAW OR ORDINANCE AND SHALL KEEP THE OWNER HARMLESS FROM ANY DAMAGE AND EXPENSE ARISING FROM ANY VIOLATION OF THE LAWS, RULES OR ORDINANCES. 8. ALL WIRE SHALL BE COPPER, IN RACEWAY UNLESS OTHERWISE SPECIFIED. 9. WIRE UP COMPLETE ALL THE A/C EQUIPMENT AND CONTROLS AS DIRECTED BY A/C CONTRACTOR. CONTROL WIRING SHALL BE SEPARATE RACEWAY FROM POWER WIRING. 10. PREWIRE TELEPHONE SYSTEM INSIDE APARTMENT. 11. PREWIRE CABLE TV SYSTEM INSIDE APARTMENT. 12. PROVIDE MEANS "FURNISH AND INSTALL". 13. COORDINATE WORK WITH WORK OF OTHER TRADES TO AVOID ALL CONFLICTS. 14. DO A COMPLETE JOB, EVERYTHING CONNECTED, READY FOR USE. 15. PROVIDE TEMPORARY WIRING SYSTEM FOR USE OF ALL TRADES, ADEQUATE FOR ENTIRE NEEDS OF THIS PROJECTS. 16. CONNECT ALL MOTORS, STARTERS, CONTROLS, DISC. SWITCHES, CKT. BKR. ETC., WHETHER FURNISHED UNDER THIS CONTRACT BY THE GENERAL CONTRACTOR. OTHER SUBCONTRACTORS, OR THE OWNER. 17. PROVIDE PULL WIRES WHEN EMPTY CONDUITS ARE SHOWN ON THE PLANS. 18. PROVIDE LIGHT FIXTURES AS PER LIGHTING FIXTURE SCHEDULE. 19. PROVIDE EMPTY PVC RACEWAYS (SERVICE ENTRANCE) FOR TELEPHONE Co., CABLE TV Co. & POWER CO. AS PER THEIR REQUIREMENT. 20. PROVIDE ALL WIRING DEVICES AND DIRECTIONS. 21. IDENTIFY CLEARLY ON A TYPE WRITTEN FORM ALL CIRCUITS AND EQUIPMENT TO CORRESPOND WITH THE PLANS AND PANELS SCHEDULE AND ATTACH INSIDE THE PERTAINING PANEL 22. PROVIDE FIRE ALARM SYSTEM AS PER LOCAL AUTHORITIES REQUIREMENTS. 23. RACEWAYS: ALL UNDERGROUND RACEWAYS TO BE PVC, INSIDE CONCRETE SLAB EMT WITH APPROVED SET SCREW FITTING, OR PVC, INSIDE PARTITIONS OR CEILINGS USE EMT OR ARMORED FLEXIBLE CABLE(AC) IF ALLOWED BY LOCAL AUTHORITIES. 24. SHOP DRAWINGS: THIS CONTRACTOR SHALL FURNISH THE ENGINEER WITH SHOP DRAWINGS OF EQUIPMENT PRIOR TO PURCHASE FOR APPROVAL 25. TESTING; THE CONTRACTOR SHALL TEST ALL WORK AND EQUIPMENT AS DIRECTED BY THE ARCHITECT AND BY AUTHORITIES HAVING JURISDICTION, FURNISHING ALL EQUIPMENT AND NECESSARY PERSONNEL AND ELECTRIC POWER. THE ENTIRE INSTALLATION SHALL BE TESTED FOR SHORTS, GROUNDS AND OPEN CIRCUITS, AND ALL DEFECTS SHALL BE DEMONSTRATED TO BE IN PROPER WORKING AND OPERATING CONDITION TO THE COMPLETE SATISFACTION OF THE ENGINEER. 26. GUARANTEES: ALL EQUIPMENT AND MATERIALS SHALL BE GUARANTEED FOR ONE YEAR AFTER THE DATE OF ACCEPTANCE BY OWNER. 27. AT COMPLETION OF JOB THE ELECTRICAL CONTRACTOR SHALL GIVE THE OWNER AN AS -BUILT SET OF REPRODUCIBLE SEPIAS SHOWING THE EXACT ELECTRICAL INSTALLATION. 28. BEFORE BIDDING THE JOB THE ELECTRICAL CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH ALL EXISTING CONDITIONS. 29. EXTEND WIRING AND MAKE ALL FINAL CONNECTIONS TO AIR COND. UNITS, SWIMMING POOL PUMPS, EXH. FANS, ETC. PROVIDE ALL DISCONNECT SWITCHES AND PUMPS, EXH. FANS, ETC. PROVIDE ALL DISCONNECT SWITCHES AND MOTOR STARTERS AS REQUIRED. 30. PROVIDE EMPTY VERTICAL RACEWAYS (RISERS) FOR TELEPHONE & CABLE. TV. 31. SEE ARCHITECTURAL PLANS FOR U/L ASSEMBLY FOR SEALING FIRE PENETRATIONS 32, POWER CO. SERVICE: BEFORE COMMENCING WORK, THE ELECTRICAL CONTRACTOR SHALL CONTACT THE POWER CO. FIELD REPRESENTATIVE AND VERIFY THE EXACT LOCATION OF THE PAD MOUNTED TRANSFORMERS. IF ANY DISCREPANCIES OCCUR BETWEEN THE DRAWINGS AND THE INFORMATION GIVEN BY THE FPL FIELD REPRESENTATIVE TO THE ELECTRICAL CONTRACTOR, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ENGINEER OF RECORD. FPL FIELD REPRESENTATIVES FOR THIS PROJECT: JIM BILLINGS - 305-387-6694 AND JOSE GARCIA 33. TELEPHONE CO. SERVICE: a. RACEWAY FROM THE STREET TO THE TELEPHONE BOARD BY THE ELECTRICAL CONTRACTOR, WIRING BY OTHERS b. RACEWAY FROM THE TELEPHONE BOARD BY THE ELECTRICAL CONTRACTOR, WIRING BY OTHERS. c. WIRING FROM EACH TELEPHONE OUTLET TO THE APARTMENT CLOSET USING FOUR PAIR CAT 5 WIRE, BY THE ELECTRICAL CONTRACTOR 34. CABLE TV CO. SERVICE: a. RACEWAY FROM THE STREET TO THE CABLE TV BOARD BY THE ELECTRICAL CONTRACTOR, WIRING BY OTHERS b. RACEWAY FROM THE CABLE TV BOARD BY THE ELECTRICAL CONTRACTOR, WIRING BY OTHERS. c. WIRING FROM EACH CABLE TV OUTLET TO THE APARTMENT CLOSET USING RG6 WIRE, BY THE ELECTRICAL CONTRACTOR 35. ALL CLEARANCE IN FRONT OF PANELS, DISCONNECT SWITCHES, TRANSFER SWITCH, STEP DOWN TRANSFORMERS, METER CENTERS, ETC. SHALL BE AS PER NEC LIGHTING FIXTURE SCHEDULE 02-28-02 O MANUFACTURER CATALOG No. LAMPS VOLTS MOUNTING REMARKS No. TYPE 1 DAYBRITE TDWAE-232-1/4EB-GLR 4 F32T8 120 SURFACE 8' VAPORLUME 2 DAYBRITE TD AE5232-1/4EB- 4 F32TB 120 SURFACE 8' VAPORLUME W/EM. BATT. 3 DAYBRITE GBR23E7 CP-1/2EB- 2 F32T8 120 WALL SURFACE STAIRWELL FIXTURE W/EM. BATTERY 4 DAYBRITE WB232-CP-232-1/2EB- GLR 2 F32T8 120 SURFACE 4' VAPORLUME 5 DAYBRITE TTT232-1/4EB-GLR 4 F32T8 120 SURFACE 8' STRIP 6 DAYBRITE T232-1/2EB-GLR 2 F32T8 120 SURFACE 4' STRIP 7 LITON LFH213E-LR661 C 2 13W DTT 120 RECESS FLOUR. DOWNLIGHT OVER APT. ENTRY DOOR 8 ASL 3210 2 13W PL 120 SURFACE WALL SCONCE FOR INSIDE CORRIDOR 9 CHLORIDE SLN-U-R-W-DL -- LED 120 UNIVERSAL INTERIOR AND DAMP LOCATION EXIT SIGN 10 CHLORIDE RLN-1/2R--W-WLVRS -- LED 120 SURFACE WET LOCATION EXIT SIGN 11 CHLORIDE GM -1 2 5.4W INCL 120 SURFACE TWO HEAD EMERG. LIGHT 12 CHANDELIER TO BE SELECTED BY OWNER 120 SURFACEELECTRICAL CONTRACTOR TO ALLOW $200.00 13 ASL FG/26/HPF 2 13W PL 120 WALL SURFACE WALL MOUNT GLOBE EXTERIOR 14 PHOENIX VPOO-2-1 -1 -1 -0 1 150W A21 120 SURFACE ELEVATOR PIT LIGHT 15 ASL HOR/26 2 13W PL 120 SURFACE 2"--.-- ROOF CABLE TV RISER DIAGRAM N.T.S 2" TO PROPERTY UNE COORDINATE WITH CABLE TV COMPANY FIELD REPRESENTATIVE ppr pr 02-28-02 pr ISSUE FOR PERMIT 14 qq 07-29-02 Iq 2 BLDG. DEPT. CORD. Iq pr pr rp pp pp pp pp pp q q W q p PO PO w 00 PO PO Q 00 44 44 5TH FL. 7 7 7 7 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 7 - 7 VJ 7 0 0 0 0 0 0 0 0 0 0 0 0 1101 00 < cTv> 0 cTv > 1 6> 1 0 , I cTv> 0 < OTV 0 6> 4TH FL. <�> o 0 o o o o 0 0 OTV OTV 60 0 0 Ma, 3RD FL. 60 0 0 0 0 0 0 0000000000000 5TH FL. 000000000000 0 <& 0000 MB20000 0 �000 MB3 - 2"--.-- ROOF CABLE TV RISER DIAGRAM N.T.S 2" TO PROPERTY UNE COORDINATE WITH CABLE TV COMPANY FIELD REPRESENTATIVE ppr pr 02-28-02 pr ISSUE FOR PERMIT 14 qq 07-29-02 Iq 2 BLDG. DEPT. CORD. Iq pr pr rp pp pp pp pp pp q q W q p PO PO w 00 PO PO Q 00 44 44 6TH FL. 7 7 7 7 7 7 7 7 7 7 7 - 7 VJ 7 7 1101 00 5TH FL. 4TH FL. I PON. 000 44 44 44 010. 00 00 100 00 00 00 00 00 3RD FL. 44 44 10. 2ND FL. N11111. Poo polo 44 44 44 44 44 44 44 44 010. 111110 110 1110 010 110 110 110 00 010 00 0 110 44 44 44 44 1010 pool pool 00, Poo pol Poo pol TTB2 44 4 44 4 4 4 44 POL 0110, 010. 000 010. 0. 00 00 101 00 0 00 TTB 1 Poo 100 111110 00. 11101 oil. TTB3 (2)4=/ TELEPHONE RISER DIAGRAM N.T.S (2)4" TO PROPERTY LINE COORDINATE WITH TELEPHONE COMPANY FIELD REPRESENTATIVE STO R. TORRES PE# 0049958 E.E. EB0003862 FLORIDA ENGINEERING SERVICES MECHANICAL AND ELECTRICAL ENGINEERS 34 N.W. 168TH STREET FES i r NORTH MIAMI BEACH, FL. 33169 TELEPHONE: 305 653-0212 • FAX: (305) 653-0232 REVISIONS BY 02-28-02 ISSUE FOR PERMIT 07-29-02 2 BLDG. DEPT. CORD. V J Z W � w I..L F- Q Q L O - VJ D RAW N CHECKED DATE 02-28-02 SCALE JOB NO. 02013 SHEET E-23 OF SHEETS