Loading...
02-509-149NOTE: TELEPHONE IN KITCHEN USE SINGLE PHONE JACK PLATES. IN BEDROOMS AND LIVING ROOMS USE DUAL PHONE JACK PLATES. USE 6 PAIR CAT5 WIRE. (UNIT C TOP FL.) 994 SQ FT ® 3 WATTS/SQ FT TWO 20 AMP SMALL APPL CKT ® 1500 WATTS EACH RANGE WATER HEATER DRYER REFRIGERATOR DISHWASHER GARB. DISPOSAL WA_SHFR TOTAL WITHOUT DEMAND * * UNITS "C2" 100 AMPS, 120/208 VOLTS, 10,000 AIC M.L.O., 12 CIRCUITS, LOAD CENTER SIEMENS E1224ML1100FG OR EQUAL fiE' WIRE 1A 12 « 1 POLE 15 AMPS REFRIGERATOR 1B TWO 20 AMP SMALL APPL CKT ® 1500 WATTS EACH 2 POLE 2 POLE 6 2 POLE RANGE 7A 10 50 AMPS 3A 12 1 POLE S 20 AMPS 0 ADPLMALL 3B 12 1 POLE 20 AMPS D WASHER 5A 12 1 POLE SMALL 20 AMPS APPL 5B TWO 20 AMP SMALL APPL CKT ® 1500 WATTS EACH 2 POLE 2 POLE 12 20 AMPS WTR HTR 7A 10 30 AMPS 78 12 1 POLE S 20 AMPS 0 ADPLMALL 9A 12 1 POLE 20 AMPS DISHWASHER 0 9B TWO 20 AMP SMALL APPL CKT ® 1500 WATTS EACH 28 2 POLE t0 2 POLE DRYER UNIT 30 AMPS 10 30 AMPS 11A 12 4B 11B 12 1 POLE GARB.DISPOSAL 20 AMPS WIRE Ido ' LTGS & RECEPT 1 POLE 20 AMPS 12 2A **AIR TWO 20 AMP SMALL APPL CKT ® 1500 WATTS EACH 28 2 POLE t0 8.0 UNIT 30 AMPS WATER HEATER 4A BATHROOM 1 POLE RECEPT 0 20 AMPS 12 4B LTGS & RECEPT 1 POLE 15 AMPS 14 6 LTGS & RECEPT 1 POLE 0 15 AMPS 14 8 SPACE 14 10 SPACE 12 * QT QUAL CIRCUIT BREAKER PROVIDE LOCK OFF DEVICE FOR WATER HEATER CKT. BKR. ** BEFORE INSTALLATION THE ELECTRICAL CONTRACTOR SHALL VERIFY THE SIZE OF CIRCUIT BREAKER AND FEEDER WITH NAME PLATE RATING OF THE A/C EQUIPMENT. *** PROVIDE ARC FAULT PROTECTION AT BRANCH CIRCUIT BREAKERS SERVING RECEPTACLE OUTLETS INSTALLED IN BEDROOM ONLY AS PER NEC 210.12(b) FIRST 10.0 KW ® 100% NEXT 17.5 KW ® 40% AIR COND. ® 100% TOTAL CONNECTED LOAD WATTS TO AMPS (LINE): 23400 /208V = 112 AMPS FEEDER THWN AL. 3#1/0 & 1#6 CU GND 1-1/2" PVC s * « UNIT "C, Cl & C3" Ro ' WIRE KIN NEC TABLE 220-30 (UNIT C 2nd & TYP.) KW 2.9 994 SQ FT ® 3 WATTS/SQ FT 2.9 3.0 TWO 20 AMP SMALL APPL CKT ® 1500 WATTS EACH 3.0 8.0 RANGE 8.0 4.5 WATER HEATER 4.5 5.0 DRYER 5.0 0.7 REFRIGERATOR 0.7 1.2 DISHWASHER 1.2 0.7 GARB. DISPOSAL 0.7 1.5 WASHER 1.5 27.5 TOTAL WITHOUT DEMAND 27.5 10.0 FIRST 10.0 KW ® 100% 10.0 7.0 NEXT 17.5 KW ® 40% 7.0 6.4 AIR COND. ® 100% 4.9 23.4 TOTAL CONNECTED LOAD 21.9 WATTS TO AMPS (LINE): 21900 /208V = 105 AMPS FEEDER : THWN AL. 3#1/0 & 1#6 CU GND. 1-1/2" PVC 125 AMPS, 120/208 VOLTS, 10,000 AIC M.L.O., 16 CIRCUITS, LOAD CENTER SIEMENS G1624ML1125 OR EQUAL 1 6 2 POLE RANGE 50 AMPS 3 5 10 2 POLE WTR HTR 30 AMPS 7 9A 12 1 POLE LTGS & RECEPT 20 AMPS 9B 12 DISH WASHER «• AIR 12 2 POLE DRYER COND. 2 POLE 10 30 AMPS 11A SL352-8 GARB. DISP. 11B 12 1 POLE BATHROOM 20 AMPS D RECEPT 13A 12 1 POLE REFRIGERATOR 15 AMPS 138 12 DISH WASHER «• AIR 12 2 POLE COND. 2 POLE 8 20 AMPS 15A SL352-8 GARB. DISP. 15B 12 1 POLE 20 AMPS D WASHER WIRE Re SPACE g SPACE g SMALL APPL 1 POLE 0 20 AMPS 12 10A SMALL APPL 1 POLE 20 AMPS 12 2 «• AIR MOUNTING 6 BR COND. 2 POLE 8 28/4A UNIT 40 AMPS SL352-8 6 - - SOW A19 120 4 SPACE g SPACE g SMALL APPL 1 POLE 0 20 AMPS 12 10A SMALL APPL 1 POLE 20 AMPS 12 108 LTGS & RECEPT 1 POLE 15 AMPS 14 12 LTGS & RECEPT 1 POLE 15 AMPS 14 14 LTGS & RECEPT 1 POLE 15 AMPS 14 16 * QT QUAL CIRCUIT BREAKER PROVIDE LOCK OFF DEVICE FOR WATER HEATER CKT. BKR. ** BEFORE INSTALLATION THE ELECTRICAL CONTRACTOR SHALL VERIFY THE SIZE OF CIRCUIT BREAKER AND FEEDER WITH NAME PLATE RATING OF THE A/C EQUIPMENT. *** PROVIDE ARC FAULT PROTECTION AT BRANCH CIRCUIT BREAKERS SERVING RECEPTACLE OUTLETS INSTALLED IN BEDROOM ONLY AS PER NEC 210.12(b) **** TANDEM CIRCUIT BREAKER *ss * s** (UNIT Cl) none i►in 983 SQ FT ® 3 WATTS/SQ FT TWO 20 AMP SMALL APPL CKT ® 1500 WATTS EACH RANGE WATER HEATER DRYER REFRIGERATOR DISHWASHER GARB. DISPOSAL WASHER TOTAL WITHOUT DEMAND FIRST 10.0 KW ® 100% NEXT 17.5 KW ® 40% AIR COND. ® 100% TOTAL CONNECTED LOAD WATTS TO AMPS (LINE): 21900 /208V = 105 AMPS FEEDER : THWN AL 3#1/0 & 1#6 CU GND. 1-1/2" PVC NEC TABLE 220-30 (UNIT C2) 705 SQ FT ® 3 WATTS/SQ FT TWO 20 AMP SMALL APPL CKT ® 1500 WATTS EACH RANrF WATER HEATER nRYFR REFRIGERATOR DISHWASHER GARB. DISPOSAL WASHER TOTAL WITHOUT DEMAND FIRST 10.0 KW ® 100% NEXT 15.2 KW ® 40% AIR COND. ® 100% TOTAL CONNECTED LOAD WATTS TO AMPS (LINE): 20400 /208V = 98 AMPS FEEDER : THWN AL. 3#1 & 1#8 CU GND. 1-1/4" PVC NEC TABLE 220-30 (UNIT C3) 958 SQ FT ® 3 WATTS/SQ FT TWO 20 AMP SMALL APPL CKT ® 1500 WATTS EACH RANGF WATER HEATER nRYFR REFRIGERATOR DISHWASHER GARB. DISPOSAL WASHER TOTAL WITHOUT DEMAND FIRST 10.0 KW ® 100% NEXT 17.4 KW ® 40% AIR COND. ® 100% TOTAL CONNECTED LOAD WATTS TO AMPS (LINE): 21200 /208V = 102 AMPS FEEDER THWN AL 3#1/0 & 1#6 CU GND. 1-1/2" PVC 2.9 3.0 8.0 4.5 5.0 0.7 1.2 0.7 1.5 10.0 7.0 4.9 21.9 2.1 3.0 8.0 3.0 5.0 0.7 1.2 0.7 1.5 LJ.L 10.0 6.1 4.3 20.4 I35'I 2.8 3.0 8.0 4.5 5.0 0.7 1.2 0.7 1.5 27.4 10.0 6.9 4.3 21.2 UNIT C SCALE: 1/4" = 1'-0" GROUND FLOOR ONLY No Smoke Detector within 3' of a kitchen or bathrcom door with a tub or shower. UNIT C2 SCALE: 1/4" = 1'-0" none uin NOTE: SMOKE DETECTORS TO BE CONNECTED TO KITCHEN LIGHT CIRCUIT AHEAD OF SWITCH. UNIT Cl SCALE: 1/40 = 1'-0" LIGHTING FIXTURE 6 O MANUFACTURER CATALOG No. 6 VOLTS MOUNTING 6 BR No. TYPE 28/4A THOMAS SL352-8 6 - - SOW A19 120 LIVING ROOM 8 HALL, FOYER B 6 8 ®BEDROOM SL446-8 1 60W A19 120 SURFACE 9'-O" �8 C THOMAS 6 SI 4 40WG25 5A 2A SURFACE 2' VANITY STRIP SECOND BATHROOM DINING ROOM 3'-7" THOMAS TR4702-8 76 8 P75W 120 9A --- 8 KITCHEN E _ G G �� I 12A - 78 - 5A�� 8 l U SL9435-8 1 G 5A D J, 120 WALL 4'-2 1/2" ,5B/7�1 2A 2A G SLB J F THOMAS SL7418-8 6 I 40W G25 1B 3A 2A G �5A 9- � ,\ SURFACE 3' VANITY STRIP MASTER BATHROOM G 38J 2A TR10-TRM30W 1 �1A 120 RECESS � / w 4 -0 3 4 -- G ( 2A H THOMAS PA TRY 4B ,2A �✓ 1 No Smoke Detector within 3' of a kitchen or bathrcom door with a tub or shower. UNIT C2 SCALE: 1/4" = 1'-0" none uin NOTE: SMOKE DETECTORS TO BE CONNECTED TO KITCHEN LIGHT CIRCUIT AHEAD OF SWITCH. UNIT Cl SCALE: 1/40 = 1'-0" LIGHTING FIXTURE SCHEDULE (APARTMENTS ONLY) O MANUFACTURER CATALOG No. LAMPS VOLTS MOUNTING REMARKS No. TYPE A THOMAS SL352-8 1 SOW A19 120 SURFACE HALL, FOYER B THOMAS SL446-8 1 60W A19 120 SURFACE CLOSET, UTILITY ROOM C THOMAS SL7402-8 4 40WG25 120 SURFACE 2' VANITY STRIP SECOND BATHROOM D THOMAS TR4702-8 1 P75W 120 TRACK KITCHEN E THOMAS SL9435-8 1 60W A19 120 WALL EXT BALCONY F THOMAS SL7418-8 6 I 40W G25 120 SURFACE 3' VANITY STRIP MASTER BATHROOM G THOMAS TR10-TRM30W 1 75W PAR30 120 RECESS HALLWAY H THOMAS TR10-TSH12P 1 60W A19 120 RECESS SHOWER LIGHT APPROVED BY MIAMI-DADE COUNTY FIRE DEPARTMENT SPK BLDG, PERhNT ONSITE WATER MAIN EXTENSION ----71 DATE UNIT C3 SCALE: 1/4" = 1'-0" ERNESTO R. TORRES PE# 0049958 E.E. E80003862 FLORIDA ENGINEERING SERVICES MECHANICAL AND ELECTRICAL ENGINEERS - : r 3t, N.W. 168TH STREET NORTH MIAMI BEACH, FL. 33169 TELEPHONE: (305) 653-0212 -V' ' FAX: (305) 653-0232 REVISIONS BY 02-28-02 ISSUE FOR PERMIT 1 04-12-02 FIRE DEPT. COM. 2 07-29-02 BLDG. DEPT. CORD. VJ Z 5W G c Q - LL- - Z Q W O Q� 0C) LJJ i Q - W -�_ _-- W '-' U) - .0--; - 'O VJ DRAWN CHECKED DATE 02-28-02 SCALE JOB NO. 02013 SHEET E-2 1 OF SHEETS