02-509-148UNITS "81, B2 & D1"
No ' WIRE
150 AMPS, 120/208 VOLTS, 10,000 AIC
M.L.O., 16 CIRCUITS, LOAD CENTER
SIEMENS G2030ML1150 OR EQUAL
1
8 2 POLE RANGE
50 AMPS
3
5
10 2 POLE WTR HTR
30 AMPS
7
9A
12
1 POLE LTGS & RECEPT
20 AMPS
98
12
DISH WASHER
ss AIR
10
2 POLE
DRYER
COND. 2 POLE
10
30 AMPS
11A
VOLTS
GARB. DISP.
118
12
1 POLE BATHROOM
20 AMPS RECEPT
13A
12
1 POLE
15 AMPS REFRIGERATOR
13B
12
DISH WASHER
ss AIR
12
2 POLE
COND. 2 POLE
10
20 AMPS
15A
VOLTS
GARB. DISP.
15B
12
1 POLE
20 AMPS WASHER
17 SPACE
19 SPACE
WIRI EM -1
SPACE 6
SPACE e
SMALL APPL = 1 POLE
20 AMPS
12
10A
SMALL APPL =1 POLE
20 AMPS
12
2
ss AIR
COND. 2 POLE
10
MANUFACTURER
UNIT 30 AMPS
VOLTS
MOUNTING
REMARKS
4
SPACE 6
SPACE e
SMALL APPL = 1 POLE
20 AMPS
12
10A
SMALL APPL =1 POLE
20 AMPS
12
108
LTGS & RECEPT 1 POLE
15 AMPS
14
12A
LTGS & RECEPT 1 POLE
15 AMPS
14
128
1 POLE
LTGS & RECEPT = 15 AMPS
14
14
LTGS & RECEPT 1 POLE
0 15 AMPS
14
16
1 POLE
LTGS & RECEPT = 15 AMPS
14
18
LTGS & RECEPT 1 POLE
0 15 AMPS
14
20
* QT QUAL CIRCUIT BREAKER
PROVIDE LOCK OFF DEVICE FOR WATER HEATER CKT. BKR.
** BEFORE INSTALLATION THE ELECTRICAL CONTRACTOR SHALL VERIFY THE
SIZE OF CIRCUIT BREAKER AND FEEDER WITH NAME PLATE RATING OF THE
A/C EQUIPMENT.
2�+++ PROVIDE ARC FAULT PROTECTION AT BRANCH CIRCUIT BREAKERS SERVING
RECEPTACLE OUTLETS INSTALLED IN BEDROOM ONLY AS PER NEC
210.12(b)
**** TANDEM CIRCUIT BREAKER
+++++ FOR UNIT 81 ONLY
ss►s
ss..
sss
sss
s.s
ssss+
.NEC TABLE 220-30 (UNIT 81 & B2)
1040 SQ FT ® 3 WATTS/SQ FT
TWO 20 AMP SMALL APPL CKT ® 1500 WATTS EACH
RANGE
WATER HEATER
DRYER
REFRIGERATOR
DISHWASHER
GARB. DISPOSAL
WASHER
TOTAL WITHOUT DEMAND
FIRST 10.0 KW ® 100%
NEXT 17.7 KW ® 40%
AIR COND. ® 100%
TOTAL CONNECTED LOAD
WATTS TO AMPS (LINE): 22000 /208V = 106 AMPS
FEEDER : THWN AL. 3#110 & 1#6 CU GND. 1-1/2" PVC
NEC TABLE 220-30 (UNIT D1)
1387 SQ FT ® 3 WATTS/SQ FT
TWO 20 AMP SMALL APPL CKT ® 1500 WATTS EACH
RANr;F
WATER HEATER
nwFR
REFRIGERATOR
DISHWASHER
GARB. DISPOSAL
WASHER
TOTAL WITHOUT DEMAND
w
3.1
3.0
8.0
4.5
5.0
0.7
1.2
0.7
1.5
27.7
10.0
7.1
4.9
22.0
WIT4
4.1
3.0
8.0
4.5
5.0
0.7
1.2
0.7
1.5
4;7W
FIRST 10.0 KW ® 100% 10.0
NEXT 18.7 KW ® 40% 7.5
AIR COND. ® 100% 4.9
TOTAL CONNECTED LOAD 22.4
WATTS TO AMPS (LINE): 22400 /208V = 108 AMPS
FEEDER : THWN AL. 3#1/0 & 1#6 CU GND. 1-1/2" PVC
LIGHTING FIXTURE
SCHEDULE
(APARTMENTS ONLY)
ISSUE FOR PERMIT
LAMPS
O
MANUFACTURER
CATALOG No.
VOLTS
MOUNTING
REMARKS
No.
TYPE
vj
A
THOMAS
SL352-8
1
60W A19
120
SURFACE
HALL, FOYER
B
THOMAS
SL446-8
1
60W A19
120
SURFACE
CLOSET, UTILITY ROOM
C
THOMAS
SL7402-8
4
40WG25
120
SURFACE
2' VANITY STRIP SECOND
U_Q -
BATHROOM
D
THOMAS
TR4702-8
1
P75W
120
TRACK
KITCHEN
E
THOMAS
SL9435-8
1
6OW A19
120
WALL
EXT BALCONY
F
THOMAS
SL7418-8
6
40W G25
120
SURFACE
3' VANITY STRIP MASTER
BATHROOM
G
THOMAS
TR10-TRM30W
1
P75W
120
RECESS
HALLWAY
H
THOMAS
TR10-TSH12P
1
60W A19
120
RECESS
SHOWER LIGHT
UNIT 131
SCALE: 1/4" = 1'-0"
UNIT B2
SCALE: 1/4" = 1'-0"
No Smoke Detector within 3' of a kitchen or
bathFOUM door with a tub or shower.
APPROVED BY
M1AM1-DADS COUNTY FIRE DEPARTMENT
SPK BLDG. PZRNIIT ONSI7
WATER MAIN EXTENSION
DATE%l.2 YlZ BY- =CG, - �..��
ERNESTO R.TORRES
UNIT Dl PE# 0049958 E.E.
SCALE: 1/4" = 1'-0" EB0003862
FLORIDA ENGINEERING SERVICES
MECHANICAL AND ELECTRICAL
ENGINEERS
L '
•� +,,� J�
U v '734 N.W. 168TH STREET
rr G NORTH MIAMI BEACH, FL. 33169
V .TELEPHONE: (305) 653-0212
�'•, FAX: (305) 653-0232