02-509-125
2" THICK, R=8.0, f -INTERNAL DUCT INSULATION. ELECTRIC STRIP HEATER PAC -1,2 (3000 CFM) 1_6x_2_4(SEE DETAIL ON SHEET AC -17) -------------------- I ----------- LEVEL 6 ; ---------- 1" THICK EXTERNAL ---- DUCT INSULATION I IN CHASE. LEVEL 5 - - - - - - - - - - - - - - - - --, FINISHED ---------- CLG. (TYP) I Ir:l LEVEL 4 ---------- 16x24 SHEETMETAL DUCT ----- IN 2HR. FIRE RATED ' CHASE I �- L LEVEL 3 ---------- ', ---- - 8x14 FIBERGLASS DUCT (TYPICAL) FSD TYP, LEVEL 2 LEVEL 1 PRIMARY AIR #1 &2 RISER DIAGRAM N.T.S 2" THICK, R=8.0, INTERNAL DUCT INSULATION. ELECTRIC STRIP HEATER PAC -5 (2500 CFM) (SEE DETAIL ON SHEET AC -17) ROOF CURB 6x20 SUPPLY (TYPICAL) AIR DUCT BEYOND W/FSD 1" THICK EXTERNAL DUCT INSULATION IN CHASE. ---------------- FINISHED J7 CLG. (TYP) 1606 SHEETMETAL DUCT ---- IN 2HR. FIRE RATED CHASE 8x14 FIBERGLASSFSD DUCT (TYPICAL) two *% 1Ox30 LEVEL 6 Zpa PRIMARY AIR #4 RISER DIAGRAM N.T.S LEVEL 5 LEVEL 4 3 LEVEL 2 LEVEL 1 ROOF CURB (TYPICAL) ------------------- I I 1" THICK EXTERNAL:- - - , DUCT INSULATIONI IN CHASE. - - - - - - - - - - - - - - - - - FINISHED CLG. (TYP) 20x22 SHEETMETAL DUCT I IN 2HR. FIRE RATED CHASE , ------------------ ----- - ----- 10x10 FIBERGLASS DUCT (TYPICAL) FSD TYP. ' LEVEL 2 FSD AT SLAB 1000 FIBERGLASS DUCTIr PENETRATION LEVEL 1 2" THICK, R=8.0, INTERNAL DUCT INSULATION. ELECTRIC STRIP HEATER PAC -3 (3000 CFM) 1_6x_2_4__ '11(SEE DETAIL ON SHEET AC -17) �- ROOF CURB (TYPICAL) LEVEL 6 LEVEL 5 LEVEL 4 PRIMARY AIR #3 RISER DIAGRAM N.T.S 1" THICK EXTERNAL' -- DUCT INSULATION IN CHASE. ---------------- - FINISHED CLG. (TYP) 2" THICK, R=8.0, INTERNAL DUCT INSULATION. ELECTRIC STRIP HEATER 16x24 PAC -5 (1500 CFM) (SEE DETAIL ON SHEET AC -17) -"- ROOF CURB (TYPICAL) LEVEL 6 LEVEL 5 LEVEL 4 16x16 SHEETMETAL DUCT ----- ---------- IN 2HR. FIRE RATED CHASE LEVEL 3 ---------- 6x12 FIBERGLASS FSD ' DUCT (TYPICAL) (TYP.) LEVEL 2 -------------------- - -FSD AT SLAB --- 6x12 FIBERGLASS DUCT PENETRATION LEVEL 1 PRIMARY AIR #5 RISER DIAGRAM N.T.S REVISIONS BY 02-28-02 ISSUE FOR PERMIT QBLDG. DEPT. COORD 2 07-29-02 2 07-29-02 BLDG. DEPT. CORD. Ir:l �- z ^ LL -� -0 L � -Lfl--z Q � _ Q D w O �- L O W DRAWN PROJECT AC DESIGN REQUIREMENTS CHECKED DATE 02-28-02 DUCT SMOKE DETECTOR ALBERT SHUB SCALE FIRE DAMPERS)/ --- PE# 0043414 M.E. JOB NO. 02013 V EB0003862 SHEET SMOKE DAMPERS/ FLORIDA ENGINEERING SERVICES V MECHANICAL AND ELECTRICAL ENGINEERS FIRE RATED ENCLOSURE FIRE RATED ROOF/ CEILING ASSEMBLY ___ • • • • • • ' v'% o FIRE STOPPINGFES AC_l --_ SMOKE CONTROL �13�i N.W. �T T� C.= :NORTH MIAMI FL 33169 .=r ; TELEPHONE: 305 653-0212 HVAC SYSTEM REQUIREMENTS FAX: �305� 653-0232 OF SHEETS AS PER S.F.B.C. 4901.4(C)