Loading...
02-509-1222 WALL CAPS AC -1 -- (AC -5) TERRACE / BALC. ® _ 4"0 DRYER EXH. 2 WALL CAPS AIRTIGHT UNDER 4"0 DOOR r16 TLT EXH. — 8 AIRTIGHT T DOOR 14x6 SR (16x6 SR) 18x18 225 CFM (250 CFM) TERRACE / BALC. RAG BEDROOM #2 1x AC -2 AIR SCOOP 4"0 DRYER EXH. 10 (AC 7)- (TyP) UNDER 4"0 12 12 BEDROOM TLT EXH. x T 16x6 SR (20x6 SR) x 8 75 CFM (325 CFM) - LIVING ROOM 8 8xSR ( x6 18x18 SUPPLY REG. BEDROOM #1 1255 (1CF CFM (150 CFM) RAG ABOVE RAG. I AIR SCOOP 16x6 SR (18x6 SR) W.I.C. I _ (NP) 250 CFM (300 CFM) (� N 4"0 — _ 10x6 SR 12x6 4 150 CFM (175 CFM) - - --- _ - Ll 4.0 6I 0 6x4 SR 50 CFM 4"0 4"0 6"� LIVING ROOM W.I.C. BATH �-0 _ - KITCHEN EF -2 CIE] 8x6 SR 8x6 SR _ RECIRC 100 CFM 6x4 SR 75 CFM RESIDENTIAL 25 CFM RECIRC KITCHEN EXH. HOOD. 40 EF -1 BATH EXS!DENTIAHOOD• UNIT AUNITB SCALE: 1/4" = 1'-0" 2 SCALE: 1/4" = 1'-0" WALL CAP 2 WALL CAPS WALL CAP AIRTIGHT WALL CAP ® DOOR - O -- 10x8 I I 2 0 t AC_7 TERRACE / BALC. 4'0 1 TERRACE / EXH. DRYER BEDROOM #2 8 AC -8) — — I UNDER 4"0 BALC. C-1 I { EXH. TLT 16 x 8x6 SR I 14x8 10x8 i (TYPjC0071 P 8 I { T BEDROOM #3 100 CFM BEDROOM � 18x20 RAG 10x6 SR I) /l175 CFM I 16x8 T AIR SCOOP I — — I 20x6 SR 1 � 12 16x16 (�) 350 CFM BEDROOM #1 I 4" 0 EXH.TLT. 10x6 SR x /� RAG 10x6 SR 10x6 NJ 175 CFM 6 2756CSR SR 150 CFM LIVING ROOM { I I FM 4"0 EXH.TLT. Coe W.I.C. r UTIL D• � "8"� LIVING ROOM 4„0 4N N 4 L l \ NO - W.I.C.f — W.I.C. 6x4 SR 0 O — O I o— O — 25 CFM5� 8x6 SR BATH ����Ef 1 75 FM KITCHEN RECIRC KITCHEN - RESIDENTIAL 6x4 SR 8x6 SR BEXH. HOOD. ATH 25 CFM � 75 CFM RECIRC 6x4 SR - RESIDENTIAL 25 CFM EF -1 EXH. HOOD. BATH EF -1 n \ 1 14"0 2 UNIT D SCALE: 1/4" = 1'-0" NOTES: 1. ALL BATHROOM AND BEDROOMS DOORS ARE TO BE 1" UNDERCUT ABOVE FINISHED FLOOR OR CARPET. 2. MECHANICAL CONTRACTOR SHALL COORDINATE FINAL LOCATION OF ALL AIR DIFUSERS SO AS TO MANTAIN A MIN OF 3'-0" FROM ANY SMOKE DETECTOR. 3. MECHANICAL CONTRACTOR SHALL COORDINATE FINAL SIZE AND LOCATION OF R/A PLENUM W/ ALL TRADES PRIOR TO FABRICATION AND INSTALLATION OF ANY DUCTWORK. 4. THERMOSTATS SHALL BE INSTALLED AT 48 INCHES ABOVE FINISHED FLOOR. 5. ITEMS IN PARENTHESIS APPLY TO UNITS AT 6TH LEVEL ONLY. 2 UNIT T E SCALE: - ,'-D" REVISIONS BY 02-28-02 ISSUE FOR PERMIT QBLDG. DEPT. COORD 2 07-29-02 2 07-29-02 BLDG. DEPT. CORD. nQn O --LL =--�;_- C C z- o 0 < J' - w - Lu .. OJ � - q � L1�J 0 C/)Z F- 0 v! DRAWN CHECKED PROJECT HVAC DESIGN REQUIREMENTS YES NO DATE 02-28-02 DUCT SMOKE DETECTOR ALBERT SHUB SCALE FIRE DAMPER(S) PE# 0043414 M.E. JOB NO. 02013 E80003862 FLORIDA ENGINEERING SERVICES SHEET SMOKE DAMPERS / MECHANICAL AND ELECTRICAL y K, ENGINEERS FIRE RATED ENCLOSURE Joe.. FIRE RATED ROOF/ CEILING ASSEMBLY �� '1 • �J/ t i • ' J m FIRE STOPPING -CC --- : 9 AC�l 3 SMOKE CONTROL �. I ' X34 N.W. 168TH STREET NORTH MIAMI BEACH, FL TELEPHONE: (3 5) 653-021269 HVAC SYSTEM REQUIR / / E M E N TS FAX: (305) 653-0232 OF SHEETS AS PER S.F.B.C. 4901.4(C)