Loading...
02-509-118ENGINEER'S OFFICE -I �I I DUCT SMOKE DETECTOR �I FROM - L- i LOUVERED DOOR COMMERCIAL PARKING I STORAGE I I i I I' I I I I STAIR 3 N - RESIDENT PARKING --- GARAGE I I I YES NO DUCT SMOKE DETECTOR FROM - L- DEPT. _ ❑ Q2BLDG. 07-29-02 FIRE RATED ENCLOSURE r - FIRE RATED ROOF/ CEILING ASSEMBLY 2 BLDG. DEPT. CORD. --- FIRE STOPPING I: SMOKE CONTROL FD -ti- HVAC SYSTEM REQUIREMENTS AS PER S.F.B.C. 4901.4(C) 10x6k'ER 10x6 ER 175 CFM I I: FIRE SP. DOMESTIC PUMP RM. PUMP RM. i 2Q • Q 12x8 SR I I �J 0 QLL- FD X12x8 SR o — O>LL. H� LLj il2xlO12x8 C) U O I- -- SR Q Lu •'18X12 �r � _-- - - 8x12 OAL- V0 V J I I. W/FD I I. I I it j— — -- I I I I I I I I I' I I I I STAIR 3 N - RESIDENT PARKING --- GARAGE I I I PROJECT HVAC DESIGN REQUIREMENTS YES NO DUCT SMOKE DETECTOR FROM - L- DEPT. _ ABOV Q2BLDG. 07-29-02 FIRE RATED ENCLOSURE PROJECT HVAC DESIGN REQUIREMENTS YES NO DUCT SMOKE DETECTOR FROM FIRE DAMPER(S) DEPT. SMOKE DAMPERS ABOV Q2BLDG. 07-29-02 FIRE RATED ENCLOSURE r - FIRE RATED ROOF/ CEILING ASSEMBLY 2 BLDG. DEPT. CORD. --- FIRE STOPPING SMOKE CONTROL FD -ti- HVAC SYSTEM REQUIREMENTS AS PER S.F.B.C. 4901.4(C) I COMMERCIAL PARKING STAIR 6 DRAWING NOTES: 1- 12X10 0/A INTAKE LOUVER LEFT CAPPED FOR CONNECTION TO FUTURE VENTILATION DUCTWORK. 2- 5"0 SHEETMETAL TOILET DUCT LEFT CAPPED FOR FUTURE USE. 3- 3/8" LIQUID / 1-1/8" VAPOR LINES UP TO ROOF LEFT CAPPED FOR FUTURE USE. 4- 8"0 SHEETMETAL TOILET DUCT UP TO EXH. FAN AT ROOF 5- 2 HRS. FIRE RATED ENCLOSURE -1 Ll COMMERCIAL SPACES i i� r' FUTURE A/C C UNIT (TYPICAL) O 3 , 1 D I I I ' O C COMMERCIAL SPACES FUTURE A/C L — — — — UNIT (TYPICAL) 0 C O RESIDENT PARKING n EF -2 SUSPENDED BY 02-28-02 FROM STRUCTURE DEPT. COORD ABOV Q2BLDG. 07-29-02 r - 2 BLDG. DEPT. CORD. 10x8 8x6 © 08-12-02 FD -ti- 10x6k'ER 10x6 ER 175 CFM 175 CFM FIRE SP. DOMESTIC PUMP RM. PUMP RM. i 2Q Q 12x8 SR FD �J 0 QLL- FD X12x8 SR o — O>LL. H� LLj il2xlO12x8 C) U O -- SR Q Lu •'18X12 �r � _-- - - 8x12 OAL- V0 V J W/FD FUTURE A/C J UNIT (TYPICAL) y REFRIG. LINES CHASE ABOVE (TYPICAL) COMMERCIAL SPACES KEY PLAN 12x10 OAL MATCHLINE 1 REVISIONS BY 02-28-02 ISSUE FOR PERMIT DEPT. COORD Q2BLDG. 07-29-02 07-29-02 2 BLDG. DEPT. CORD. © 08-12-02 Q �J 0 QLL- Q0_ IJ o — O>LL. H� LLj C) U O Q Lu 0 Z � � V0 V J DRAWN CHECKED DATE 02-28-02 ALBERT SHUB SCALE n"( �•��j PE# 0043414 M.E. JOB NO. 02013 ?.'. • • • • • •. C „ EB0003862 SHEET *FLORIDA ENGINEERING SERVICES -",.-MECHANICAL AND ELECTRICAL �,.., ENGINEERS FIRST FLOOR PLAN - PAR ..I'," � - SCALE: 1/8" = 1'-0" , . C,: AC l� -9 i 1 •6\',. ES� 01 �" 34 N.W. 168TH STREET NORTH MIAMI BEACH, FL. 33169 TELEPHONE: (305) 653-0212 FAX: (305) 653-0232 OF SHEETS