12-1372-090FLUIuI5IN(:� FIXTUFRE SCHEDULE
SYMBOL
FIXTURE TYPE
SIZE
C.W.
H.W.
DESCRIPTION
SHOWER HEAD
WATER CLOSET
3'
'/2
DISHWASHER
6.5 gallons per cycle or less
(Energy Star/Water Sense Certified)
0
LAVATORY
11/2'
1/2"
1/2'
V
®
BATH TUB
2'
1/2"
1/21
w/ ANTI -SCALD VALVE
SHOWER
2'
1/2"
1/2'
w/ ANTI -SCALD VALVE
KITCHEN SINK
11/21
1/2"
1/2'
w/ GARBAGE DISP05AL
ULJ
DISHWASHER
-
i/21
DISCHARGE INTO GARBAGE
DISPOSAL UNIT.
FD
WASHING MACHI.
2"
11/2
1/2"
O
W
O
NOTE: ALL DRRAIN PIPING UNDER SLAB SHALL BE 2' MIN
2" 4 LESS DIA DRAIN e 1/4' DROP
3" 8 4' DIA DRAIN 6 1/8" DROP
WALL
FACE OF WALL.'
STAINLESS STEEL COVER
SCREWED TO THREADED
C.O. PLUG.
"ZURN" *Z -1446 -15P -VP
FOR EXPOSED BLOCK
AND GYPSUM BOARD
WALLS. 'ZURN'
*ZN-144-1-BP-VP FPR TILE
WALLS. 'ZURN'
*ZN-1448-5P-VP FOR
PLASTER WALLS.
"ZURN"
*ZN-1400-15P-T-VP CONCRETE PAD 'ZURN' *Z-1404-VPIRON
FLOOR CLEANOUT. 2'x2'x8' W/ 4* 3EW. BOX W/ COVER MARKED
'G O
FIN. FLR FIN. GRADE
Lj
jF 9
FILL VOIDS W/
SECTION VIa\\,
COMPACTED OILED SAND.
FORFILL
CLARITY.ELEVATION VIE LEANOUT
TTING W/
F\",5`RA55 PLUG.
FLOOR /
TWO-WAY CLEANOUT TEE
OR LONG SWEEP QUARTER
BEND.
NOTE: REFER TO SPECIFICATIONS FOR
MATERIALS
AND REQUIREMENTS FOR INSTALLATION.
CLEANOUT DETAILS N.T.S.
k
SOIL_ /WATER TA5L_ E 5 I TE
EVALUATION CRITERIA NT5
'GUY GRAY" MODEL T-200 DRAIN
BOX. MOUNT 42" A.F.F. OR AS
DIRECTED BY ARCHI
NOTE: DRAIN PIPING
SLOPE NO LE55
1/4' PER FOOT.
3'
REMOVEAf5LE
TO TRAP
GRADE
WASHING MACHINE DRAIN BOX
NOTES
GENERAL
PROVIDE ( FURNISH AND INSTALL ) ALL NECESSARY
MATERIALS AND LABOR FOR A COMPLETELY OPERATIONAL
PLUMBING SYSTEM AS SHOWN ON THE DRAWINGS AND
HEREIN SPECIFIED. INSTALL IN ACCORDANCE WITH THE
FLORIDA BUILDING CODE AND LOCAL ORDINANCES.
SCOPE OF WORK
PROVIDE THE FOLLOWING COMPLETE SYSTEMS
A. SANITARY COLLECTION.
B. DOMESTIGOT ANL -.;C -OLD WATER.
C. AIR CONDITIONING CONDENSATE.
PAY FOR ALL FEES, INSPECTIONS AND CONNECTION
CHARGES REQUIRED
VERIFY AT JOB SITE ALL SPACE CONDITIONS, DIMENSIONS
WITH PIPE, FIXTURES, AND EQUIPMENT SIZES PRIOR TO
FABRICAT IONORINSTALL ATION.COORDINATE REQUIREMENTS
TO AVOID INTERFERENCE WITH OTHER TRADES.
SUBMIT SHOP DRAWINGS FOR ARCHITECT / ENGINEER
APPROVAL BEFORE PROCEEDING WITH THE PURCHASE OR
INSTALLATION OF EQUIPMENT AND MATERIALS.
GUARANTEE ALL WORK FREE OF DEFECTS IN MATERIALS
AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM
DATE OF ACCEPTANCE.
RL W-15INC LEGEND
SANITARY SEWER LINE
----------- VENT LINE
CD CONDENSATE DRAINAGE LINE
CTG-- CLEANOUT TO GRADE
WCOII WALL CLEANOUT
FD FLOOR DRAIN
- COLD WATER (C.W.) LINE
- - HOT WATER (H.W.) LINE
PT PRESS. 4 TEMP. RELIEF L INE
><I GATE VALVE
I
CHECK VALVE
I
I
I
I
I
I
I
I
I
I
I
N.T.S.
UJATFzR CON51J1„IFT I O 'N IN
FL_ U-15 ING FIXTURE
FITTINGS
MAXIMUM FLOW RATE
WATER CLOSETS
1.28 << gallons per flushing cycle
LAVATORY
1.0 << gpm at 60 psi
SHOWER HEAD
1.5 << gpm at 80 psi
SINK FAUCET
1.0 << gpm at 60 psi
DISHWASHER
6.5 gallons per cycle or less
(Energy Star/Water Sense Certified)
WASHING MACHINE
Water factor of 8 or lower
(Energy Star/Water Sense Certified)
a
0
O O O O O 0.11
MATERIALS
PROVIDE SHUT-OFF VALVES FOR EACH FIXTURE AND AIR
CHAMBERS WHERE SHOWN AND WHERE REQUIRED FOR
PROPER PERFORMANCE OF THE SYSTEM.
PROVIDE DIELECTRIC FITTINGS TO CONNECT PIPING TO
EQUIPMENT OF DISSIMILAR METALS. USE L::i_/,MF'S AND
FASTENERS OF SIMILAR METALS OR ISOLA i E THE1"' FRO` I
PIPING AND SLABS TO PREVENT CORROS:Ch-
PIPING
DOMESTIC HOT ANDCOLD WATER: PVC TUBING TYPE
SANITARY WASTE AND VENT= PVC PIPING
A/C CONDENSATE, PVC SGEDULE, 40 PIPE AND FITTINGS.
P.V.C. DRAIN PIPE AND FITTINGS MAY BE USED WHEN
ALLOWED BY THE LOCAL JURISDICTION.
VB
VIV
VTR
AFF
• FE
-� FEC
FCO
TO FIXTURES
TITAN
SCR -3 IN 120
TANKLES5
WATER HEATER
FROM SERV.
COLD WATER
5TANDARD...--..... ``"....................... ANZIZ, 10.03
DIMENSIONS ............................... ........ 10'X -1 "X2.15"
WEIGHT ........ ........ __
............... .....-..._.....8 POUNDS
MATERIALS......................................_BRASS CASING
PIPE FITTING
...................3/4' STANDARD PIPE
PRESSURE REQUIREMENTS E, PSI-MIN./150 PSI -MAX.
VOLTAGE......
..... _ ... ......220 VAC STD, (208/211 AVAIL.)
55°
INCOLOY/NICHROME
ENERGY EFFICIENCY... -..._.._...._....EF .:31
MAX_
MODEL KW at 220 V
VOLTS
MAX.
AMPS at 220 V
5GR-3 12 KW
220 V
120
TEMPERATURE CHART °F
MODEL
1 GPM
1.5 GPM
2 GPM
3 GPM
4 GPM
SCR -3
109°
-13°
55°
36°
27°
WATER HEATER DETAIL
N.T.S.
UNION
HOSE BIBS
VACUUM BREAKER
VALVE IN VERTICAL
VENT THRU ROOF
ABOVE FINISHED FLOOR LEVEL
FIRE EXTINGUISHER ON WALL BRACKET (2A-I05C)
FIRE EXTINGUISHER IN CABINET (2A -105C)
FLOOR CLEAN OUT
PRESS. 4 TEMP. RELIEF VALVE
�r { a!
�3 A
LOT 3
DATE :SEPTEMBER, 2012
SCALD 5HOWN
DRAWN: M. GASTELLON
DESIGN BY JR
JOB NO=
P-2.
C3
O
U
3.-
N
U_
z
CY)
3
W
CL
V
::D
LL-
LO
m€
0
.�
W
-o�
0
"E
ULJ
ED
DATE :SEPTEMBER, 2012
SCALD 5HOWN
DRAWN: M. GASTELLON
DESIGN BY JR
JOB NO=
P-2.
REVL4ION3
L-
O
U
3.-
U_
z
CY)
3
W
CL
V
::D
LL-
LO
0
.�
W
0
"E
ULJ
ED
Of
.J
O
W
O
O
LL
®
"�
LU
CU
:.;
W
C�
DATE :SEPTEMBER, 2012
SCALD 5HOWN
DRAWN: M. GASTELLON
DESIGN BY JR
JOB NO=
P-2.
REVL4ION3
L-
2-
3.-
4. -
DATE :SEPTEMBER, 2012
SCALD 5HOWN
DRAWN: M. GASTELLON
DESIGN BY JR
JOB NO=
P-2.