12-1372-0795TRUCTUR L NOTE5: GOORDINATION: -COORDINATE ALL, DIMENSIONS; ELEVATIONS 4 OPENINGS WITH ARCHITECTURAL DRAWINGS, REPORT ANY DISCREPANCIES TO OUR Ck-FICE. FOUNDAT ION5: -SOIL STATEMENT- VISUAL INSPECTION OF THE SITE SHOWS A SOIL OF LIMESTONE WITH SANDY POCKETS AND WITH A LAYER OF TOPSOIL, THIS LIMESTONE HAS A SAFE BEARING CAPACITY IN EXCESS OF 2000 psF. AT THE TIME OF CONSTRUCTION A LICENSED ARCHITECT OR POFESSIONAL ENGINEER SHALL SUBMIT TO THE BUILDING OFFICIAL A LETTER ATTESTING THAT THE 51TE HAS BEEN OBSERVED AND THE FOUNDATIONS CONDITION5 ARE SIMILAR TO THOSE UPON WHICH THE DESIGN IS BASED. III -DING PAD PREPARATION: -TREES, 5RU5H, ROOTS, TOPSOIL, RUBBLE, ORGANICALLY CONTAMINATED OR OTHERWISE OBJECTIONABLE MATERIALS ENCOUNTERED ARE TO BE REMOVED FROM STRUCTURAL AREA5 OF THE SITE. FOR A MINIMUM DISTANCE OF FIVE FEET OUTSIDE STRUCTURE PERIPHERY. -EXISTING GROUND BENEATH STRUCTURE FOUNDATION SHALL PROOF ROLLED. AREAS EXHIBITING INSTABILITY ARE TO BE UNDERCUT AND 5ACKFIELD AND GOMPACTED. -THE PROPOSED ENGINEERED FILL MATERIALS ARE TO BE PLACED IN LIFTS NOT EXCEEDING EIGHT (3) INCHES LOOSE MEASURED THICKNESS IN UNCONFINED LIFTS OR 6" IN CONFINED AREAS. EACH LIFT IS TO BE COMPACTED AS FOLLOWS: I,- SLAB ON GRADE: MINIMUM OF 1 5% MAXIMUM DENSITY BY ASTM D1557, 2.- FOOTING BEARING: MINIMUM OF 95% MAXIMUM DENSITY BY ASTM D1551. TE ITE PROTECTION: AS PER F.B.C. 105.11 BUILDING COMPONENTS AND BUILDING SURROUNDINGS REQUIRED TO BE -PROTECTED FROM TERMITE DAA/AGE IN ACCORDANCE WITH 1503.4.4, 1804.62,7, 1916.1.5, 2304 OR 2603.3, OR REQUIRED TO NAVE CHEMICAL SOIL TREATMENT IN ACCORDANCE WITH 1316 SHALL NOT 5E COVERED OR CONCEALED UNTIL THE RELEASE FROM THE BUILDING OFFICALHA5 BEEN RECEIVED. ALL BUILDINGS SHALL HAVE PRE -CONSTRUCTION TREATMENT PROTECTION AGAINST - SUBTERRANEAN TERMITES A5 PER F.B.G. 1816.1.7. A CERTIFICATE OF COMPLIANCE SHALL BE 165UED TO THE BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWING STATEMENT: "THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. TREATMENT 15 IN ACCORDANCE WITH THE RULES ANP LAWS ESTABLI&HED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER 11;ERVICE5" CONCRETE: MARK -COMPRF5SIVE STRENGTH AT 28 DAYS: RE INFORCEMENT SLAB ON FILL: 3000 PSI ALL OTHER POURED -IN-PLACE CONCRETE:-_ 3000 P51 GROUT: 3000 PSI TE5`1': "B" B14R5 A MIN, OF 5 CONCRETE SPECIMENS SHALL BE TAKEN FROM EACH 50 CU, YD, OR PORTION THEREOF SPECIMENS SHALL BE TESTED ACCORDING TO A.S.T.M, C-39, ONE AT 3, ONE AT 7, AND 3 AT 28 DAYS. #4 o24" -COVER: o- CONCRETE DEP051TED AGAINST THE GROUND: 3" FORM)=D CONCRETE IN CONTACT WITH THE GROUND- 2" BEAMS AND COLUMNS: 1-1/2" INTERIOR 5LA55: 3/4" EXTERIOR SLABS 1-1/2" SLAB ON FILL: (PLACED ACCORDING TO ACI 302) -JOINTS: ISOLATION JOINTS MUST PE USED AT JUNCTIONS WITH WALLS AND COLUMN5, USE 1/2" THICK PREMOLDED JOINTS FULL DEPTH OF SLAB. CONTROL JOINTS PLACED AT CENTERLINE OF COLUMN LINES PROVIDE INTERMEDIATE JOINTS IF COLUMN SPACING 15 GREATER THAN 30'. IN 51DEW4LK5 PROVIDE TOOLED JOINTS SPACED AT INTERVALS EQUAL TO THE WIDTH OF THE SLAB, 4" 3 5" SLABS: 1" DEEP TOOLED JOINTS MU57 BE SAWED BEFORE 24 HOURS AFTER CONCRETING. CONSTRUCTION JOINTS MUST BE PLACED IN THE SLAB WHERE BUILDING EXPANSION JOINTS ARE SHOWN AND WHERE CONTROL JOINTS ARE SHOWN. WHEN CONCRETING AND OPERATING ARE CONCLUDED FOR THE DAY, CONSTRUCTION JOINTS SHALL BE FORMED WITH BURKE KEYED KOLD METAL JOINT FORM OR APPROVED EQUAL. -VAPOR BARRIERS: WATERPROOF MEMBRANES (OVERLAPPED 6" AT JOINTS) WITH A PERMEANCE OF LESS THAN 0.3 PERMS IN ACCORDANCE WITH A.5.T.M. E-93 SHALL BE PROVIDED UNDER INTERIOR SLAB, WHERE NO VAPOR BARRIER IS USED THE 5u5GRADE MUST BE DAMPENED WITH WATER IN ADVANCE OF CONCRETING NO FREE WATER STANDING ON THE SUBGRADE NOR ANY MUDDY OR SOFT SPOT I5 PERMITTED. -ANY STRUCTURAL MEMBER PENETRATING SLAB ON FILL 15 70 BE 1/2" PRE -MOLDED JOINT FILLER COMPLYING WITH A.S.T.M, D-1152, TYPE I. -FINISHING: NO PREMATURE FINISHING SHALL BE ALLOWED. IMMEDIATE FOLLOWING FLOATING TROWELING WITH STEEL TROWELS SHOULD BE COMMENCED IF REQUIRED BROOMING SHALL BE .AFTER THE 5TEEL T TROWELING OPERATION. -SLAB FINISHE5: (UNLESS OTHERWISE NOTED BY THE ARCHITECT) BUILDING: --- STEEL TROWELED U OUTSIDE SLAB: _ BROOMFD REINFORCING STEEL: -REINFORCING BARS CONFORMING TO A.S.T.M. A-615 GRADE 60, INCLUDING COLUMN AND BEAM TIES. -WELDED FIRE FABRIC CONFORMING TO A_53M. A-185 AND SUPPORTED ON SLAB BOLSTERS p SPACED AT 3'-0" O/C. -FABRICATION AND DETAILING ACCORDING TO I -ALL ACC=SSORIES TO HAVE UPTURNED LEGS AND E3E PLASTIC DIPPED AFTER FABRICATION. -* STRUCTURAL STEEL: cN -ALL 5TRUCTURAL 5TEEL PLATES, ANGI_ES, M, S, C MC 5HAP1=S SHALL CONFORM TO 4.5,T,M. A-3(,. 10 W -ALL STRUCTURAL STEEL WELDING SHALL BE PERFORM WITH A,W.5. D.I.I. -ALL ANCHOR L3CLT5 SHALL CONFORM TO 4.5.T.M. A-301. -ALL BOLTS SHALL GONFORt-I TOcl (LI) -ALL SQUARE/RECTANGULAR COLUMNS SHALL CONFORM TO A.5.T.M. A-500, GRADE C My = 46 KSI). q -PROVIDE ONE SHOP COAT OF RUST INHIBITING PAINT MIN. 3 ML, DRY FILM THICKNESS). -FABRICATIONS AND ERECTIONS SHALL BE DONE IN ACCORDANCE WITH THE LATEST A.I.S.C, SPECIFICATIONS, 0 WELDING: -ALL WELDING SHOULD BE PERFORMED IN ACCORDANCE WITH THE REQUIREMENTS SET FORTH BY N A.W.S. BY CERTIFIED WELDERS. -CONTRACTORS TO USE E-10 SERIES LOW HYDROGEN ELECTRODES. C3' TIMBER: o ALL JOIST5 AND RAFTERS SHALL HAVE A MIN. 5TRE55 GRADE OF I -b = 1260 F51, E=1,700000 F'S1 (SOUTHERN YELLOW FINE). -TRUSS MANUFACTURER TO SUBMIT SIGNED AND SEALED SHOP DRAWINGS AND CALCULATIONS FOR APPROVAL INDICATING ALL REACTIONS TO THE SUPPORTING STRUCTURE. PRE -FABRICATED WOOD1&66E5 : -SHALL BE DE5IGNED AND FABRICATED IN ACCORDANCE WITH THE TRUSS PLATE INSTITUTE (T.P.I.), LAI -EST EDITION. TRUSSES TO BE ERECTED FOLLOWING THE GUIDELINES OF THE T.P.I. PUBLICATION BWT-16, 513M1T LAYOUT PLAN AND INDIVIDUAL DRAWINGS FOR EACH DIFFERENT TRUSS, 51GNED AND i SEALED BY A FLORIDA REGISTERED PROFESSIONAL ENGINEER, FOR APPROVAL BY STRUCTURAL ENGINEER PRIOR TO FABRICATION. -GENERAL CONTRACTOR TO PROVIDE PERMANENT LATERAL BRACING OF THE BOTTOM CHORD AND THE WEB MFMBERS IN ACCORDANCE WITH RI=COMMENDATIONS OF T.P.I. BWT-16 AND THE REaUIREMENTS OF THE INDIVIDUAL TRUSS DESIGNS, SUBMIT PERMANENT BRACING PLAN FOR APPROVAL BY ENGINEER CL PRIOR TO ERECTION, GIRDER TRUSSES TO BE BOLTED TOGETHER WITH 1/2" DIA. 5OLT5 AT 24" C/C AT ri TOP CHORD, BOTTOM CHORD, AND WEB MEMBERS. -CONTRACTOR TO 5UBMIT SIGNED AND SEALED SHOP DRAWINGS BY A DELEGATED SPECIALTY L ENGINEER FOR ALL TRU55 TO TRU55 CONNECTIONS. TRU55 MANUFACTURER TO VERIFY UPLIFT AND GRAVITY TRU55 REACTIONS 51-IOUN ON FRAMING PLANS. -ALL TRUSSES AND/OR J015T SHALL BE SFCURFD 70 THE BEARING PARTITIONS OR THE BEAMS WITH HURRICANE STRAPS A5 INDICATED ON PLANS. STAGGER TRUSSED 45 REQUIRED TO ACHIEVE PROPER BEARING (4" MIND. `11 -PROVIDE AN 13 GAGE METAL STRAP TO TIE DOWN ALL THE "PIGGY BACK" TRU55E5 TO THE MAIN TRUSSES AT ALL THE BEARING POINTS. ELECTRICAL CONDUITS V' -WHERE REINFORCING STEEL CONGESTION PERMITS, CONDUIT AND PIPES UP TO 1" DIAMETER MAY BE EMBEDDED IN CONCRETE PER ACI 310, SECTION 6.3. SPACE AT 3 DIAMETERS O.C. PLACE BETWEEN OUTER LAYERS OF REINFORCING IF CONDUITS ARE SIGNIFICANTLY CONGESTED, ADDITIONAL G REINFORCING PERPENDICULAR TO PIPING MAY BE REQUIRED. REQUESTS TO EMBED LARGER PIPES cD SHOULD BE ACCOMPANIED BY A DETAILED DESCRIPTION AND BE SUBMITTED TO THE ARCHITECT L FOR EVALUATION. LLJ Ld 51-40P DRAWING SU13MITT45: -SUBMIT FIVE PRINTS OF .ALL SHOP DRAWINGS LISTED 5FLOW, IF SIGNED AND LIJ SEALED SHOP DRAWINGS ARE REQUIRED, THEN SUBMIT TWO ADDITIONAL SIGNED AND SEALED z PRINTS FOR APPROVAL. J -SHOP DRAWINGS: o REINFORCING 5TEEL. STRUCTURAL 5TEEL. -� CONCRETE MIX DESIGN. ROOF TRUSSES MA50NRY WALLS: -BEARING MASONRY SHOWN THUS IN PLAN SHALL BE ERECTED PRIOR TO THE 5TRUCTURE ABOVE HAS BEEN POUR D. -NON-BEARING MASONRY SHOWN THUS +1Kz=!-4l IN PLAN SHALL BF ERECTED AFTER THE STRUCTURE ABOVE HAS BEEN POURED. -MORTAR CONFORMING TO A.S.TM, C-210 TYPE "M" (2500 PSI). -PROVIDE 9 GAGE LADDER TYPE HORIZONTAL REINFORCEMENT AT 16" O/C (FOR REINFORCED WALLS). -PROVIDE 9 GAGE TRUSS TYPE HORIZONTAL REINFORCEMENT AT 16" O/C (FOR NON -REINFORCED WALLS) -WHENEVER ANCHORS BOLTS ARE TO BE SET IN MASONRY, TWO CELLS AT THE SETTING LOCATION SHALL BE FILLED WITH CONCRETE. -GROUT FOR MA50NRY UNITS SHALL CONFORM TO 45TM C410 -PRIM5 STRENGTH OF MASONRY UNITS SHALL BE MINIMUM OF F'm = 1500 Pal. (F'c = 1900 PSI) -MAXIMUM POUR LIFT FOR MASONRY UNITS AND GROUT POUR HEIGHT SHALL BE 4'-0" -GROUT FOR FILLED CELLS SHALL HAVE A MIN, COI"IPRE551VE STRENGTH OF 3000 PSI WITH A SLUMP OF 9" TO 11 -CONCRETE BLOCKS SHALL BE C-90 TYPE, PLACED IN RUNNING BONDS. DESIGN CRITERIA: (SUPERIMPOSED LOADS) -LIVE LOAD: 30 Pap (ROOF) -DEAD LOAD: 20 PSF (ROOF) 30 P5F (LIVING AREAS) -WIND LOAD: PER A.S.C.E. 7-10 RISK CATI=GORY: _U EXPOSURE - IICII IMPORTANCE: 1,00 WIND VELOCITY: 115 MPH MEAN ROOF HEIGHT: 24.1' GcF!: 0.13 (ENCLOSED) 0.55 (PARTIALY ENCLOSED) OWNER, ARCHITECT, ANp CONTRACTOR NOTE: -CHECK FOR SHOP DRAWINGS AND INSPECTIONS OF REINFORCEMENT IN THE FIELD ARE REQUIRED IF THIS OFFICE 15 TO BE HELD RE5PON51B9LE FOR THE STRUCTURAL ADEQUACY OF THE CONSTRUCTED BUILDING. 5HORING, RE-514ORING. AND TEMPORARY BRACING: -ALL SNORING, RE=SNORING AND TEMPORARY BRACING REQUIRED IN THI5 PROJECT IS To BE DESIGNED BY FLORIDA PROFE55IONAL ENGINEER WHO SPECIALIZES IN FORM WORK/TEMPORARY BRACING DESIGN. AND WHO H45 BEEN HIRED BY THE GENERAL CONTRACTOR. THE GENERAL CONTRACTOR 15 THE ULTIMATE RE5PON51BLE PARTY FOR SHORING, RE -SNORING, AND TEMPORARY BRACING REQUIRED ON TH15 PROJECT AND MUST SATISFY NIM5ELF WITH THE ADEQUACY OF THE INSTALLATION OF THESE ITEMS AT ALL TIMES. IN THE SPECIFIC CASE OF POURED SL,456 IT 1,5 HIC:PLY RECOMMENDED THAT THE GENERAL CONTRACTOR SECURE FROM THE SHORING DESIGNER A CERTIFICATION Op THE INSTALLED SHORING PRIOR TO THE PLACEMENT OF CONCRETE. SAFETY OSHA AND LABOR LAWS. -THE STRUCTURE 15 DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER THE BUILDING IS FULLY COMPLETED. IT IS THE GONTRACTOR'5 SOLE RESPONSIBILITY TO DETERMINE ERECTION PROCEDURE AND SEQUENCE AND INSURE THE SAFETY OF THE BUILDING AND ITS COMPONENT PARTS DURING ERECTION. THIS INCLUDES THE ADDITION OF WHATEVER SHORING, TEMPORARY BRACING, ETC. THAT MAY BE NECCE5ARY. SUCH MATERIAL SHALL REMAIN THE CONTRACTOR'S PROPERTY AFTER COMPLETION OF THE PROJECT. -THE STRUCTURAL ENGINEER OF RECORD DOES NOT POSSES, NOR PRESUMES TO P056ES ANY KNOWLEDGE OR EXPERTISE IN MATTERS TO JOB SITE EMPLOYEE SAFETY, OSHA OR LABOR LAW REQUIREMENTS FORA CON5TRUCTION PROJECT, SAFETY AND COMPLIANCE WITH OSHA AND LABOR LAWS ARE THE ABSOLUTE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND TH05E CONSULTANTS HE HIRES TO ADDRESS THESE MATTERS. THE STRUCTURAL ENGINEER OF RECORD SPECIALIZES IN STRUCTURAL DE51GN ONLY, AND THE BOARD OF PROFESSIONAL REGULATION FORBIDS HIM FROM A55UMIN6 RESPONSIBILITY OUTSIDE HIS AREA OF EXPERTISE A�ICA���COPEB: IN MY PROFEa51ONAL JUDGEMENT AND THE PEST OF MY KNOWLEDGE AND BELEIF, THESE PLANS AND SPECIFICATIONS COMPLY WITH THE FLORIDA BUILDING CODE. -ALTHOUGH THE ENCxIN1=ER OF RECORD HAS STRIVED TO MEET ALL APPLICABLE CODES AND LOCAL ORDINANCE REaUIREMENT5, THE CONTRACTOR 15 STILL RESPONSIBLE FOR COMPLYING WITH ALL APPLICABLE COE5 AND ORDINANCES IN THE EVENT OF CONFLICT OR OVER51CxHT IN THE DRAWINGS THE CONTRACTOR MUST IMMEDIATELY NOTIFY THE ARCHITECT OR ENGINEER OF ANY CONFLICT OR DISCREPANC'1' ENCOUNTERED 50 THAT AP'f ROPRIATF REMEDIES MAY BE UNDERTAKEN. -THF APPLICABLE CODES ARE: FLORIDA BUILDING CODE, LATEST EDITION.(2001 W/2009 SUPLEMENTS) A.G.I. 318 BUILDING CODE REQUIRFMENTS FOR 5TRUCTURAL CONCRETE. A.G.I. 530 BUILDING CODE REQUIREMENTS FOR MA5ONiRY STRUCTURES. (2008 EDITION) NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION. (2005 EDITION) A.1.5.C. MANUAL, 13th. ED1710N, P.G.I. DESIGN HANDBOOK STANDARD HOOK ROOF OR COLUMN TERMINATION PT DOU15LE TIES (3" C,G,) OFFSET #g AND LARGER BARS ONLY FIN15H FLOOR OR INTERMEDIATE TIE BEAM 5EE PL AN DOUBLE TIES (3" G.C. AT BEND POINT) - JOINT J-2 EL. SEE PLAN VAPOR BARRIER SEE SPECS. r WELL COMPACTED FILL = my 3 TIES �@31I �, OF COLUMN AND FOOTING (U.O.N. IN PLAN) N lK q a m 1 3 TIES @3" u, (- CONCRETE SLAB, SEE PLAN FOR THICKNESS AND REINFORCING FK m� p EL. SEE PLAN DOWELS SAME SIZE 4 NUMBER AS VERT. RE INF. (SET TO CLEAR BARS 3" STANDARD ABOVE) CL R. HOOK FOR FOOTING SIZE AND REINFORCING, 5EE SCHEDULE I.- USE 03 TIES FOR #10 VERTICAL REINFORCING OR SMALL R. 2.- TIE SPACING SHALL BE: A - LEAST DIMENSION OF COLUMN B - 16 TIMES MAIN BAR DIAMETER G - 03 AT 18" OR #4 AT 24" WHICHEVER 15 SMALLER T` PICAL CONCiPETE COLUMN 5FLICE DETAIL FOOTING 5CHEDULE MARK SIZE W x L x D RE INFORCEMENT REMARKS LONG, TRANS. WF -16 16 "xCONT.xl2" 2 #5 - "B" B14R5 WF -24 24"xCONT.xl2" 3 05 #4 o24" No. 4 SPACING EACH END o- I I x 21'' - — O #5 #3 1 1 - - CF -20 2'-0" x 2'-0" x 12" 3 #5 3 #5 # 3 CF -30 3'-0" x 3'-0" x 12" 4 #5 4 *✓ 8" CF -36 3'-6" x 3'-&" x 16" 4 #5 4S 2 #5 NOTE : I. CONTRACTOR TO PROVIDE #5 CORNER 5AR5 LAPPED MIN, 30" EACH WAY, POR EACH BAR IN FOOTING, COLUMN 5C>4E1DULE MARK SIZE REINFORCEMENT REMARKS VERTICALS OR BASE E TIES OR CAP fR Oall x 12" 4 #5 #3N �gll "B" B14R5 "G" B14R5 12" x 12" 4 #6 #368" No. 4 SPACING EACH END o- I I x 21'' - — O #5 #3 1 1 - - ® Haa 3 1/2"x3 1/2"x5/16" SEE DETAIL SEE DETAIL # 3 �Q al, x 21" TB -2 22'-3" 8" ® 3" x 13" 4 45 Y. 2 #5 # 3 4,a12" E34L X48" RT5-1 NOTE Q DENoTE5 GoLUMN START DENOTES COLUMN END CCL. 1D ,TC -1 COL. RETS, 14 a d #3 HAIRPIN 8"O/C (3 L . 1D E T, LII-,�II -'h #2 HAIRPIN 8"O/C CCL. � DU. ACL. ET. E3EAM 5CHEDULE MARK TOP ELEV. SIZE (INCHES) BOTTOM. REINS. TOP REINFORCING STIRRUPS REMARKS W D "A" 5AR5 "B" B14R5 "G" B14R5 "T" BAR5 "E" BARS SIZE No. 4 SPACING EACH END TB -1 VARIES 8" 12" 2 4'5 2 #E, L # 3 4M2'' BAL '248" TB -2 22'-3" 8" 40" 2 #5 AK- Y. 2 #5 # 3 4,a12" E34L X48" RT5-1 VARIFS g" 12" 2 #5 2 #5 Z # 3 4-a12" BAL X48" RAKED PEAM <t �[ T R5-1 22'-3" 8" 32" 2 #e, LLI 2 #6 # .3 13 a5" O/C. 0' � / (n B -I 12'-0 3 2011 2 2 #I # 3 03 SIS✓" O/G, 5-2 9'-0" 8" 24" 2 #e, LO 2 06 # 3 #3 010" O/C, 5-3 II' -1" 8" 30" 2 #6 2 #6 # 3 43 010" O/C. 5=4 II' -I" all 24" 2 11 2 4'1 # 3 113 g3" O/C. PROVIDE 3#7 EF INTERMIDIATE BARS EQ SPA 5-5 10'-3" 8" 26" 2 1'& 2 #O # 3 #3 010" O/C. I1'u E A C�IREATER OF 03 LI OR 0.3 L2 EMPEp 12 f�A�� PIAM NOTE L "L I' 15 THE LONCtER OF A�)-JACENT STAN, 2. 0" WIDE 5FAM5 TA ,E A 1­I4XII'�l.,lM OF- 2 BAR5 FEFQ� LAYER, 3. STIRFDIJfi-S TO F3E CLOSEID T'i-FE WITH 13E° NOOK, 4. MID PARS TO BE #5 012" E_F, WHENEVER SEAM % FFTH 15 LARGER THAN 2'=0 a. CONTFACTOR TO PROVIDE 2 05 CORNER PAWS LAFDFEL�) MIN. 30" EACH UJAi, illi r::>,CDC, I t:;\1/-�tLl I /Q, LASS I'A'' LAR &FLICE IIT" PARS RUN CONTINUOU5 OR LAID AS REQV_ AT MID 5RAN. 0.3 L STP. HOOKS 6, TOP AND 5070M REINFORCEMENT 51-IALL PE CONTINUOUS FOR ALL TIE 5EAM5. i. A5 FEF, ACI 31�aa2, SECTION 1.13.2.2 IN EXTERIOR PERIMETER PI�.AM5 FROVIDE A7-1DITIONAL BOTTOM REINFORCEMENT OVER THE 5UPFORT5 EQUAL TO AT LEAST 25% OF THE LARGER TOTAL POTTCM REINFORCEMENT AREA CALLED OUT FOR THE Nip-SFAN OF AE)JACENT 5EAM5, ANE) IN AUDITION, AT LEAST 20% OF THE TO- RE INFORCEI­1FNT, i3UT NO LESS THAN TWO BARS SHALL PE CONTINUOUS OVER ALL TNI5 ADDITIONAL REINFORCEMENT 15 TO PE SfiDLICED WITH A TENSION "CLASS AI' 51 -LICE PEGINNING AT THE FACE OF THE SUFFORT. TNT'FICAL SEAM E34R FLACING� D IAGGFAM N.T.S. "C" BAR5 FOR 12" OR WIDER BEAMS TOP BARS L <1 IIC" 5AR5 (FOR 0" Bi"ISJ "MID" BARS (SEE NOTE 4) esNx "MID" BAR5 (SEE NOTE 4) BOTTOM BARS NOTE :: QUANTITY OF "MID" F 4R5 VARIES W/ F3EAMS DEPTH. SEE BEAMS SEE NOTE -4 ON BAR PLACING DIAGRAM TYPICAL EAR PLACEMENT DETAIL LOT 3 m CONSULTING Pm EERS STRUCTURAL EN�1 F 11'NG;, UU , 62628 d.RD, KS' °�� MIAMI; F 3155 6 3 F, f A E OF A., PAULA MARTINEZ. l :�,��'� a FLORIDA REG. No 6,50.p, PMMCE JOB # 11019 I Q 0 1 U Vill ITITO 21 i, 11I Er"Pil cz l 0 0 z C� W (� L__ W V E m U] Z ;�: 'ji mr J Z3 UL V J Q N SEAL REVISIONS I.- 2 3.- 4,- 5.- DATE :SEP IEMBF172, 2012 SCALE: AS NOTED DRAWN: Y. SOSA DESIGN BY: P AM JOB NO: S-1.0 �l 112r `10 1 I < L a o L J L AK- Y. o A Z <t �[ T `--' LLI Q 0' � / (n LLI D� LO � s � I Q 0 1 U Vill ITITO 21 i, 11I Er"Pil cz l 0 0 z C� W (� L__ W V E m U] Z ;�: 'ji mr J Z3 UL V J Q N SEAL REVISIONS I.- 2 3.- 4,- 5.- DATE :SEP IEMBF172, 2012 SCALE: AS NOTED DRAWN: Y. SOSA DESIGN BY: P AM JOB NO: S-1.0