12-1372-071PRINCIPAL FRONT SETBACK
REAR SETBACK
SIDE SETBACK
REQUIRED A5 PER RESOLUTION
PROPOSED
+' 49-81-3985-A
11'-0'
20'-011
101-011
251 -ON
♦
4
101-011 16'-0'
101-011 4 101-011
ZONING LEGEND P.U.D.
NET LOT AREA: 5,100 SQFT.
REQUIRED TIDO STORY MAX HEIGHT 25'
PROPOSED HEIGHT OF THE BUILDING = 25'-0'
TOTAL SQFT. PER RESOLUTION * 49-81-3985-A: 3,440 SQFT.
TOTAL SQFT PROPOSED: 3,348.29 SQFT.
FIRST FLOOR SQ.FT. PER RESOLUTION * 49-81-3985''-A: 1,915 SQFT.
FIRST FLOOR SQFT. PROPOSED: 1,821.41 SQFT.
FLOOR AREA RATIO A5 PER RESOLUTION * 49-81-3985-A: (0035 9
FLOOR AREA RATIO PROPOSED : 58.14 9.
FLOOR AREA RATIO AS PER RESOLUTION 49-81-3985-A:.60
FLOOR AREA RATIO PROPOSED: 0.58
SITE DATA
AREAS TABULATION:
A/C AREA FIRST FLOOR:------------------------'--- 1,194.31 SQFT,
GARAGE AREA: - - - - - _ _ _ _ T - 402.88 SQFT.
ENTRY AREA------------- -------------------- - 93.95 SQFT,
COVERED TERRACE T C --------------------------- - 13033 5QFT.
TOTAL:---------------------------------------- 1021AI5QFT.
A/C AREA SECOND FLOOR: --------------------- I' ---- 1,114.00 SQFT.
SECOND FLOOR AREA OPEN TO BELOW --------- - - - - 312.81 SQ.FT,
OPEN TERRACE ------------------------------------ 99.95 SQFT,
TOTAL RESIDENCE ---------------------------- 3,34829 SQFT.
I
I
TRACT '13'
(
EXISTING 6' H. C55
WALL TO REMAIN
CONCRETE PAD WITH A/C
COMPS. MOUNTING: tv 10.00
N.G.V.D.
5HRUE35 15'H. MIN.
PLANTING AROUND A/C
COND. UNIT, SEE
LANDSCAPING PLAN
NEW ELECTRICAL METER --
CONNECTED TO COMMUNIT'
ELECTRICAL SERVICE
CONTRACTOR TO FIELD
VERIFY LOCATION
m
TRACT 'A'
LOT 4
NEW DRIVEWAY
CONFIGURATION OLD
MIAMI PAVERS FINISH IAC
UNDER SEPARATE PERMIT
WIM FULL
OPEN
VALVE
GREEN AREA
LOT 3
TRACT 'G'
NEW TWO STORY
C55 RE51DENCE
MIN. FIN FL. ELEV.
+10.00'lN.G.V.D )_
wo
j10'-0'
PROPOSED1
51DE
F I I SETBACK
101.0'
_ QUIRE
IDE
eco Y I SETBACK FO
MODEL A
LOT 2
LID
EXISTING 6' H. C55
WALL TO REMAIN
CONNECTED 4' SANITARY
PIPE m 1/8' SLOPE/F.T. TO
EXISTING LATERAL SEWER
LINE
.ANTRACTOR TO PROVIDE
SLOPE TO CONTAIN
RAINWATER INTO THE
PROPERTY LINE
LEGAL DESCRIPTION
LOT 3, OF DAVIS GARDENS, ACCORDING TO THE PLAT THEREOF, AS
RECORDED IN PLAT BOOK 126, AT PAGE 45, OF THE PUBLIC RECORDS
OF MIAMI DADE COUNTY, FLORIDA.
N SITE PLAN
1
SCALE: 10 1
�mA
�
u� � O
D
a
o
/ E
TRACT 'G'
NEW TWO STORY
C55 RE51DENCE
MIN. FIN FL. ELEV.
+10.00'lN.G.V.D )_
wo
j10'-0'
PROPOSED1
51DE
F I I SETBACK
101.0'
_ QUIRE
IDE
eco Y I SETBACK FO
MODEL A
LOT 2
LID
EXISTING 6' H. C55
WALL TO REMAIN
CONNECTED 4' SANITARY
PIPE m 1/8' SLOPE/F.T. TO
EXISTING LATERAL SEWER
LINE
.ANTRACTOR TO PROVIDE
SLOPE TO CONTAIN
RAINWATER INTO THE
PROPERTY LINE
LEGAL DESCRIPTION
LOT 3, OF DAVIS GARDENS, ACCORDING TO THE PLAT THEREOF, AS
RECORDED IN PLAT BOOK 126, AT PAGE 45, OF THE PUBLIC RECORDS
OF MIAMI DADE COUNTY, FLORIDA.
N SITE PLAN
1
SCALE: 10 1
REVMNS
BuILDING DEPT, 3.-
6. -
qt
DAM :SEPTEMBER, 2012
SCAI.B SHOWN
DRAWN: M. CASTELLON
DESIGN BX- JR
JOB Nfx
LOT 3
r_aa
a
C M
/ E
n
rry
cu
00
d��' N
C C�
00
c�
E
1
<
ll
fl
LL
Z
M
LIJ
CL
c)
=)
L.L
r
w�
0
V
co
�
z
C
YKIZ
W
..�
0
Cn
0
J
O
Q
0
LL.
®
U
W
(10
.O
J
z
LJ
�
O4
U
�
iLJ:
W
ti
U
cv
cc
U
REVMNS
BuILDING DEPT, 3.-
6. -
qt
DAM :SEPTEMBER, 2012
SCAI.B SHOWN
DRAWN: M. CASTELLON
DESIGN BX- JR
JOB Nfx
LOT 3
r_aa
a
/ E
0
cu
c�
E
cci
LL
Z
M
LIJ
CL
c)
=)
L.L
r
w�
0
V
co
�
z
C
W
W
..�
0
Cn
0
J
�
Q
0
LL.
®
U
W
(10
.O
J
z
U
�
C
�
W
ti
REVMNS
BuILDING DEPT, 3.-
6. -
qt
DAM :SEPTEMBER, 2012
SCAI.B SHOWN
DRAWN: M. CASTELLON
DESIGN BX- JR
JOB Nfx
LOT 3
r_aa