Loading...
12-1372-0671. 2 3. 4. 5. a I !!!d ENERAL NOTES: COMPLY WITH FLORIDA BUILDING EDITION 2010 ALL LOCAL ORDINANCES GOVERNING. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLIANCE WITH ALL SAFETY RELATED O.S.H.A. REQUIREMENTS DURING CONSTRUCTION. ALL WORK SHALL BE PERFORMED BY A LICENSED AND INSURED STATE CERTIFIED GENERAL CONTRACTOR OR BY THE OWNER IF APPROVED BY THE LOCAL BUILDING ,DEPARTMENT OFFICIAL. ALL WINDOWS USED SHALL HAVE DADE COUNTY PRODUCT APPROVAL. SECONDARY MEANS OF ESCAPE SHALL CONFORM TO NF_P.A. 22-2.12.C. WINDOWS USED AS SECOND MEANS OF ESCAPE MUST PROVIDE A CLEAR OPENING (WHEN FULLY OPENED) OF NOT LESS THAN TWENTY INCHES (20") IN WIDTH, TWENTY FOUR INCHES (24") IN HEIGHT AND 5.-1 SQUARE FEET IN AREA± AND THE BOTTOM OF THE OPENING SHALL NOT BE MORE THAN FORTY FOUR INCHES (36 ") OFF THE FLOOR. WOOD TRUSS MANUFACTURER SHALL SUBMIT SHOP DRAWINGS AND CALCULATIONS FOR ARCHITECT'S APPROVAL PRIOR TO TRUSS FABRICATION. WOOD TRUSSES SHALL BE DESIGNED BY A FLORIDA REGISTERED P.E. STRUCTURAL STEEL: 1 2 3. 4. a ALL CONSTRUCTION SHALL CONFORM TO THE FLORIDA BUILDING CODE,2010 EDITION. REINFORCING STELL SHALL CONFORM TO ASTM A615 GRADE 60 AND ASTM A155 FOR WELDED STEEL WIRE FABRIC FOR CONCRETE REINFORCEMENT. STRUCTURAL STEEL SHAPES TO CONFORM TO THE LATEST ASTM SPECIFICATION AND SHALL BE FABRICATED IN ACCORDANCE WITH THE LATEST AI5C SPECIFICATIONS. ALL CONNECTIONS SHALL BE DESIGNED FOR THE LOADS SHOWN ON STRUCTURAL DRAWINGS OR ACCORDING TO AISC REQUIREMENTS. ALL BOLTS SHALL BE ASTM A325 BOLTS NO LESS THAN 5/5' IN DIAMETER, OR AS OTHERWISE NOTED. WELDING SHALL BE IN ACCORDANCE WITH STRUCTURAL WELDING CODE STEEL, AW6-D1.1-a6. SOIL STATEMENT: 1. INSPECTION OF THE SITE INDICATES UNDISTURBED SAND AND ROCK WITH A BEARING VALUE OF 2000 PSF SHOULD OTHER CONDITIONS OR MATERIAL BE ENCOUNTERED, THE ARCHITECT SHALL BE NOTIFIED BEFORE PROCEEDING WITH THE WORK. MECHANICAL: 1, ALL MECHANICAL WORK SHALL BE DONE IN ACCORDANCE WITH THE FLORIDA MECHANICAL CODE AND ALL LOCAL CODES GOVERNING. PLUMBING: 1. ALL PLUMBING WORK SHALL BE DONE IN ACCORDANCE WITH THE FLORIDA PLUMBING CODE AND ALL LOCAL CODES GOVERNING. ELECTRICAL: 1. ALL ELECTRICAL WORK SHALL BE DONE IN ACCORDANCE WITH THE FLORIDA ELECTRICAL CODE. THE NATIONAL ELECTRICAL CODE AND ALL LOCAL CODES GOVERNING. SHOP DRAWING SUBMITTALS: 1. REVIEW SHOP DRAWING, CATALOG CUTS,PRODUCT DATA, AND SAMPLES BEFORE SUBMISSION. DETERMINE AND VERIFY: A. FIELD MEASUREMENTS. B. FIELD CONSTRUCTION CRITERIA C. CONFORMANCE WITH CONSTRUCTION DOCUMENTS D. COORDINATE EACH SUBMITTAL WITH REQUIREMENTS OF WORK AND OF CONSTRUCTION DOCUMENTS. 2. THE CONTRACTOR SHALL SUBMIT A MINIMUN OF FOUR (4) SETS OF SHOP DRAWINGS FOR REVIEW AND APROVAL. EACH SUBMITTAL SHALL BE INCLUSIVE OF. BUT NOT LIMITED TO, DADE COUNTY, PRODUCT: APPROVAL, MANUFACTURER'S SPECIFICATIONS, INSTALLATION, RECOMMENDATIONS, COLOR SAMPLES, AND WARRANTIES. 3. DO NOT ORDER OR FABRICATE MATERIALS,UNTIL SHOP DRAWINGS HAVE BEEN REVIEWED AND AND APPROVED BY A/E. ALWAYS MAINTAIN AND HAVE AVAILABLE FOR REFERENCE A FIELD COPY OF ACCEPTED SHOP DRAWINGS AT THE JOB SITE. 4. SHOP DRAWING REQUIERED. WINDOWS AND HURRICANE SHUTTERSDOOR5. CLEANING: IN ADDITION TO REMOVAL OF RUBBISH AND LEAVING BUILDINGS 'BROOM CLEAN" A. REPLACE BROKEN GLASS B. REMOVE PAINT SPOTS AND SMEARS,STAIN5,MARK5,AND DIRT TO PROVIDE CLEAN SURFACE. C. CLEAN GLASS, I-1ARDWARE, FIXTURES, CASEWORK, AND EQUIPMENT. D. WASH CONCRETE SURFACES,TILE FLOORS, TILE WALLS AND ANY OTHER IMPERVIOUS FLOOR AND WALL SURFACES. ENVIRONMENTAL PROTECTION: 1. CONTROL AMOUNT OF DUSK RESULTING FROM CONSTRUCTION OR DEMOLITION TO PREVENT SPREAD OF DUST TO OTHER BUILDINGS AND TO AVOID CREATION OF A NUISANCE IN SURROUNDINGAREAS.USE OF WATER TO CONTROL DUST WILL NOT BE ALLOWED WHEN IT WILL RESULT IN, OR CREATE HAZARDOUS OR OBJECTIONABLE CONDITIONS SUCH AS FLOODING. 2. TRAFFIC MAINTENANCE: CONDUCT REMOVAL OPERATIONS TO MAINTAIN TRAFFIC ALONG EXISTING STREETS AND WALKS. KEEP PAVED STREETS AND WALKWAYS FREE OF DEBRIS. REMOVE MATERIAL AND OTHER MATTER TRACKED OR FALLEN ONTO TRAFFIC SURFACES. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION MATERIALS INCLUIDING DEBRIS AND DUST, AND DISPOSE OF LEGALLY OFF SITE. USE METHODS APPROVED BY A/E BEFORE BEGINING CLEANUP OPERATIONS.U5E OF BLOWERS TO D15TR15UTE DUST IS NOT ALLOWED. SAFEGUARDS DURING CONSTRUCTION: 1. SAFETY PROVISIONS DURING CONSTRUCTION AND PROTECTION OF ADJACENT PUBLIC AND PRIVATE PROPERTIES. ACCORDING TO CHAPTER 13 OF THE EXISTING FLORIDA BUILDING 2010 EDITION_ 2. THE REWIRED EXIT DOORS SHALL BE A SIDE -HINGED DOOR NOT LF -55 THAN 3 FEET IN WITH AND 6 FEET S INCHES IN HEIGHT. OTHER DOORS SHALL NOT BE REQUIRED TO COMPLY WITH THESE MINIMUM DIMENSIONS. AS PER R311.42. OF F.B.G. RESIDENTIAL. 3. ALL LOCKS OR LATCH ON EGRESS DOOR SHALL- BE READILY OPERABLE FROM THE SIDE FROM WHICH EGRE55 15 TO BE MADE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT AS PER 8311.4.4 OF F.B.C. RESIDENTIAL. 2010 EDITION 4, ALL SINGLE EXTERIOR SWING DOORS SHALL HAVE A LOCK TO BE KEY OPERATED FROM THE EXTERIOR WITH A MINIMUM OF 6000 POSSIBLE KEY CHANGES OR LOCKING AUXILIARY SINGLE DEAD BOLT WITH HARDENED BOLT. 5. THE ACTIVE LEAF OF PAIRS OF EXTERIOR SWING DOORS SHALL NAVE SAME LOCKS AS REQUIRED FOR SINGLE EXTERIOR SWING DOORS. THE INACTIVE LEAF SHALL HAVE MULTIPLE POINTS OF LOCKS WITH 5/0' IN. THROW BOLTS WITH INSERTS. 6. JAMBS OF ALL EXTERIOR OFFSET TYPE IN SWING DOORS SHALL BE RABBET, OR OF SIMILAR FABRICATION, TO PREVENT DEFEATING THE PURPOSE OF THE STRIKE AND THE INTEGRITY OF THE LOCKS AND LATCHES, 7. HINGES ON EXTERIOR OUT SWINGING DOORS SHALL HAVE NON -REMOVABLE PINS AND NDN -EXPOSED SCREWS. 8. GLASS AND EXTERIOR DOORS SHALL COMPLY WITH THE AMERICAN NATIONAL STANDARDS INSTITUTES STANDARD 29-1.1. 9. VISION PANEL EXTERIOR DOORS OTHER THAN GLAZING WITHIN 40' OF THE INSIDE LOCKING ACTIVATION DEVICE OF LOOSE AND SWING DOORS SHALL COMPLY WITH THE ANSI STANDARD 297.1. 10. ALL WINDOW, DOORS, GLASS AND GLAZING SHALL BE AS SET OF F.B.C. BUILDING 2010 EDITION. 11. ALUMINUM WINDOWS SHALL COMPLY WITH F.S.G. BUILDING 2010 EDITION 12. FRONT MAIN ENTRANCE DOORS SHALL BE PROVIDED WITH A DOOR SCOPE OR VISION PANELS. 13. ALL EGRESS WINDOWS TO HAVE A CLEAR OPENING OF NOT LESS THAN 30' IN WIDTH AND 24" IN HEIGHT, MINIMUM 51 SF. IN AREA HEIGHT TO OPENING SHALL NOT EXCEED 36' ABOVE FINISH FLOOR. 14. CONTRACTOR TO VERIFY ALL AS -BUILT OPENINGS PRIOR TO FABRICATION. MUM d O U u_ IN � O Iv^j FLAME SPREAD AND SMOKE DENSITY: 8315.1 WALL AND CEILING FINISHES SHALL BE HAVE FLAME SPREAD CLASSIFICATION OF NOT GREATER THAN 200. EXCEPTION: FLAME -SPREAD REQUIREMENTS FOR FINISHES SHALL NOT APPLY TO TRIM DEFINED AS PICTURE MOLDS, CHAIR RAILS, 5A5E5OARDS AND HANDRAILS± TO DOORS AND WINDOWS OR THEIR FRAMES± OR TO MATERIALS THAT ARE LE55 THAN Yea INCH IN THICKNESS CEMENTED TO THE SURFACE OF WALLS OR CEILINGS IF THESE MATERIALS HAVE A FLAME -SPREAD CHARACTERISTIC NO GREATER THAN PAPER OF TH15 THICKNESS CEMENTED TO A NONCOMBUSTIBLE BACKING. 8315.2 SMOKE -DEVELOPED INDEX WALL AND CEILING FINISHES SHALL HAVE A SMOKE -DEVELOPED INDEX OF NOT GREATER THAN 450. 8315.3 TESTING TEST SHALL BE MADE IN ACCORDANCE WITH ASTM E B4. 8315.4 ALTERNATE TEST METHOD. AS AN ALTERNATE TO HAVING A FLAME -SPREAD GLASIFICATION OF NOT GREATER THAN 200 AND A SMOKE DEVELOPED INDEX OF NOT GREATER THAN 450 WHEN TESTED IN ACCORDANCE WITH ASTM E 54, WALL AND CEILING FINISHES, OTHER THAN TEXTILES, SHALL BE PERMITTED TO BE TESTED IN ACCORDANCE WITH NFPA 256.MATERIAL5 TESTED IN ACCORDANCE WITH NFPA 256 SHALL MEET THE FOLLOWING CRITERIA: DURING THE 40KW EXPOSURE, THE INTERIOR FINISH SHALL COMPLY WITH ITEM *1. DURING THE 160 KW EXPOSURE, THE INTERIOR FINISH SHALL COMPLY WITH ITEM *2. DURING THE ENTIRE TEST, THE INTERIOR FINISH SHALL COMPLY WITH ITEM 3. 1. -DURING THE 40 KW EXPOSURE, FLAMES SHALL NOT SPREAD TO THE CEILING. 2. -DURING THE 160 KW EXPOSURE, THE INTERIOR FINISH SHALL COMPLY WITH THE FOLLOWING: 2.1. FLAME SHALL NOT SPREAD TO THE OUTER EXTREMITY OF THE SAMPLE ON ANY WALL OR CEILING. 22. FLASHOVER, AS DEFINED IN NFPA 286, SHALL NOT OCCUR. 3.- THE TOTAL SMOKE RELEASED THROUGHOUT THE NFPA 256 TEST SHALL NOT EXCEED 1,000 m 8316.1 INSULATION INSULATION MATERIALS, INCLUDING FACINGS, SUCH AS VAPOR RETARDERS OR VAPOR PERMEABLE MEMBRANES INSTALLED WITHIN FLOOR -CEILING ASSEMBLIES, ROOF -CEILING ASSEMBLIES, WALL ASSEMBLIES, CRAWL SPACES AND ATTICS SHALL HAVE A FLAME -SPREAD INDEX NOT TO EXCEED 25 WITH AN ACCOMPANYING SMOKE -DEVELOPED INDEX NOT TO EXCEED 450 WHEN TESTED IN ACCORDANCE WITH A5TM E 54. EXCEPTIONS: 1. WHEN SUCH MATERIALS ARE INSTALLED IN CONCEALED SPACES, THE FLAME -SPREAD AND SMOKE -DEVELOPED LIMITATIONS DO NOT APPLY TO THE FACINGS, PROVIDED THAT THE FACING IS INSTALLED IN SUBSTANTIAL CONTACT WITH THE UNEXPOSED SURFACE OF THE CEILING, FLOOR OR WALL FINISH. 2_ CELLULOSE LOOSE -FILL INSULATION, WHICH IS NOT SPRAY APPLIED, COMPLYING WITH THE REQUIREMENTS OF SECTION 83163, SHALL ONLY BE REQUIRED TO MEET THE SMOKE -DEVELOPED INDEX OF NOT MORE THA . 50. 1JI#_,DiNG DE -p : LOT 3 O_ O rLn V E 0- 0 W Q L V E ^co LL d O U u_ z � O Iv^j U 2 m �.ij � E c) r V Op CO �- C LU co o C__ z _� r__� (\�-7 O � O � LL. 0 C) O U O O z v cy) lll�j/ L.I. � V C.O z .... _ O : AEAL , Ld Vl J N I j S O_ O rLn V E 0- 0 W Q L V E ^co LL DATE :8F=f-TEM5FR, 2012 SCALD SHOWN DRAWN. N.OASTEL.ON DERGN BY' JR wa Na Fis d O U u_ z � U 2 �.ij � E c) r V MM C LU W C__ J_ O O Q O LL. 0 C) O O O z v cy) L.I. � C.O to AEAL , DATE :8F=f-TEM5FR, 2012 SCALD SHOWN DRAWN. N.OASTEL.ON DERGN BY' JR wa Na Fis